Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
28 result(s) for "Grauf, B"
Sort by:
The Imaging Magnetograph eXperiment (IMaX) for the Sunrise Balloon-Borne Solar Observatory
The Imaging Magnetograph eXperiment (IMaX) is a spectropolarimeter built by four institutions in Spain that flew on board the Sunrise balloon-borne solar observatory in June 2009 for almost six days over the Arctic Circle. As a polarimeter, IMaX uses fast polarization modulation (based on the use of two liquid crystal retarders), real-time image accumulation, and dual-beam polarimetry to reach polarization sensitivities of 0.1%. As a spectrograph, the instrument uses a LiNbO 3 etalon in double pass and a narrow band pre-filter to achieve a spectral resolution of 85 mÅ. IMaX uses the high-Zeeman-sensitive line of Fe i at 5250.2 Å and observes all four Stokes parameters at various points inside the spectral line. This allows vector magnetograms, Dopplergrams, and intensity frames to be produced that, after reconstruction, reach spatial resolutions in the 0.15 – 0.18 arcsec range over a 50×50 arcsec field of view. Time cadences vary between 10 and 33 s, although the shortest one only includes longitudinal polarimetry. The spectral line is sampled in various ways depending on the applied observing mode, from just two points inside the line to 11 of them. All observing modes include one extra wavelength point in the nearby continuum. Gauss equivalent sensitivities are 4 G for longitudinal fields and 80 G for transverse fields per wavelength sample. The line-of-sight velocities are estimated with statistical errors of the order of 5 – 40 m s −1 . The design, calibration, and integration phases of the instrument, together with the implemented data reduction scheme, are described in some detail.
The Wave-Front Correction System for the Sunrise Balloon-Borne Solar Observatory
This paper describes the wave-front correction system developed for the Sunrise balloon telescope, and it provides information about its in-flight performance. For the correction of low-order aberrations, a Correlating Wave-Front Sensor (CWS) was used. It consisted of a six-element Shack – Hartmann wave-front sensor (WFS), a fast tip-tilt mirror for the compensation of image motion, and an active telescope secondary mirror for focus correction. The CWS delivered a stabilized image with a precision of 0.04 arcsec (rms), whenever the coarse pointing was better than ± 45 arcsec peak-to-peak. The automatic focus adjustment maintained a focus stability of 0.01 waves in the focal plane of the CWS. During the 5.5 day flight, good image quality and stability were achieved during 33 hours, containing 45 sequences, which lasted between 10 and 45 min.
The Sunrise Mission
The first science flight of the balloon-borne Sunrise telescope took place in June 2009 from ESRANGE (near Kiruna/Sweden) to Somerset Island in northern Canada. We describe the scientific aims and mission concept of the project and give an overview and a description of the various hardware components: the 1-m main telescope with its postfocus science instruments (the UV filter imager SuFI and the imaging vector magnetograph IMaX) and support instruments (image stabilizing and light distribution system ISLiD and correlating wavefront sensor CWS), the optomechanical support structure and the instrument mounting concept, the gondola structure and the power, pointing, and telemetry systems, and the general electronics architecture. We also explain the optimization of the structural and thermal design of the complete payload. The preparations for the science flight are described, including AIV and ground calibration of the instruments. The course of events during the science flight is outlined, up to the recovery activities. Finally, the in-flight performance of the instrumentation is discussed.
The Filter Imager SuFI and the Image Stabilization and Light Distribution System ISLiD of the Sunrise Balloon-Borne Observatory: Instrument Description
We describe the design of the Sunrise Filter Imager (SuFI) and the Image Stabilization and Light Distribution (ISLiD) unit onboard the Sunrise balloon borne solar observatory. This contribution provides the necessary information which is relevant to understand the instruments’ working principles, the relevant technical data, and the necessary information about calibration issues directly related to the science data.
Three-dimensional Analysis of a C-class Flare Observed with Sunrise III/SCIP
Deciphering the physical properties of flares is crucial for understanding the nature of one of the most energetic events on the Sun. We analyze high spatial and spectral resolution observations of a C-class flare, focusing on a complex light bridge in the active region. The observations show Stokes profiles with opposite Doppler shifts and asymmetries between photospheric and chromospheric spectral lines, and Ca ii infrared spectral lines in emission, tracing areas of extreme atmospheric heating. Inversion results are consistent with these spectral features, showing regions of opposite-sign plasma flows between the photosphere and chromosphere, adjacent to areas with extreme chromospheric temperatures. The latter areas show relatively weak line-of-sight velocities despite the intense heating. The magnetic field configuration shows abrupt changes with height in the regions with opposite-sign flows, while remaining nearly constant with height in the areas of extreme heating. These findings point to a scenario of small-scale magnetic reconnection in the photosphere, suggesting a flare triggering mechanism based on an avalanche of many small reconnection events.
The Filter Imager SuFI and the Image Stabilization andLight Distribution System ISLiD of the Sunrise Balloon-Borne Observatory: Instrument Description
We describe the design of the Sunrise Filter Imager (SuFI) and the Image Stabilization and Light Distribution (ISLiD) unit onboard the Sunrise balloon borne solar observatory. This contribution provides the necessary information which is relevant to understand the instruments' working principles, the relevant technical data, and the necessary information about calibration issues directly related to the science data.
The Imaging Magnetograph eXperiment (IMaX) fortheSunrise Balloon-Borne Solar Observatory
The Imaging Magnetograph eXperiment (IMaX) is a spectropolarimeter built by four institutions in Spain that flew on board the Sunrise balloon-borne solar observatory in June 2009 for almost six days over the Arctic Circle. As a polarimeter, IMaX uses fast polarization modulation (based on the use of two liquid crystal retarders), real-time image accumulation, and dual-beam polarimetry to reach polarization sensitivities of 0.1%. As a spectrograph, the instrument uses a LiNbO sub(3) etalon in double pass and a narrow band pre-filter to achieve a spectral resolution of 85mAa. IMaX uses the high-Zeeman-sensitive line of Fe i at 5250.2Sand observes all four Stokes parameters at various points inside the spectral line. This allows vector magnetograms, Dopplergrams, and intensity frames to be produced that, after reconstruction, reach spatial resolutions in the 0.15-0.18arcsec range over a 5050arcsec field of view. Time cadences vary between 10 and 33s, although the shortest one only includes longitudinal polarimetry. The spectral line is sampled in various ways depending on the applied observing mode, from just two points inside the line to 11 of them. All observing modes include one extra wavelength point in the nearby continuum. Gauss equivalent sensitivities are 4G for longitudinal fields and 80G for transverse fields per wavelength sample. The line-of-sight velocities are estimated with statistical errors of the order of 5-40ms super(-1). The design, calibration, and integration phases of the instrument, together with the implemented data reduction scheme, are described in some detail.
The Sunrise Chromospheric Infrared Spectro-Polarimeter SCIP: an instrument for SUNRISE III
The Sunrise balloon-borne solar observatory is equipped with a one-meter aperture optical telescope, offering a unique platform for uninterrupted seeing-free observations across ultraviolet, visible, and infrared wavelengths from altitudes higher than 33 km. For the third flight of the upgraded Sunrise observatory conducted in 2024, now called Sunrise III, a new spectro-polarimeter called the Sunrise Chromospheric Infrared spectroPolarimeter (SCIP) was developed for observing near-infrared wavelength ranges around 770 nm and 850 nm. These wavelength ranges contain many spectral lines, including two of the Ca II infrared triplet, K I D1 and D2 lines, and multiple Fe I lines, that are sensitive to solar magnetic fields and velocities in the photosphere and chromosphere. SCIP consists of a grating spectrograph in which polarimetric measurements are conducted using a rotating waveplate as a modulator and polarizing beam splitters placed in front of the cameras. The spatial and spectral resolutions are 0.21\" and 1x10^5, respectively, and a polarimetric sensitivity of 0.03% (1sigma) of the continuum intensity is achieved with a 10 s integration time per a resolution element. To achieve high-precision detection of small polarization signals, we carefully designed the optical and mechanical systems, polarization components, control electronics, and onboard data processing. Together with the other post-focus instrumentation developed for Sunrise III, the Sunrise Ultraviolet Spectropolarimeter and Imager (SUSI) and the visible imaging spectro-polarimeter Tunable Magnetograph (TuMag), SCIP provides novel observations that help elucidate energy transfer and time-dependent phenomena across the solar photosphere and chromosphere.
Reconstruction of total solar irradiance variability as simultaneously apparent from Solar Orbiter and Solar Dynamics Observatory
Solar irradiance variability has been monitored almost exclusively from the Earth's perspective. We present a method to combine the unprecedented observations of the photospheric magnetic field and continuum intensity from outside the Sun-Earth line, which is being recorded by the Polarimetric and Helioseismic Imager on board the Solar Orbiter mission (SO/PHI), with solar observations recorded from the Earth's perspective to examine the solar irradiance variability from both perspectives simultaneously. Taking SO/PHI magnetograms and continuum intensity images from the cruise phase of the Solar Orbiter mission and concurrent observations from the Helioseismic and Magnetic Imager onboard the Solar Dynamics Observatory (SDO/HMI) as input into the SATIRE-S model, we successfully reconstructed the total solar irradiance variability as apparent from both perspectives. In later stages of the SO mission, the orbital plane will tilt in such a way as to bring the spacecraft away from the ecliptic to heliographic latitudes of up to \\(33^\\). The current study sets the template for the reconstruction of solar irradiance variability as seen from outside the ecliptic from data that SO/PHI is expected to collect from such positions. Such a reconstruction will be beneficial to factoring inclination into how the brightness variations of the Sun compare to those of other cool stars, whose rotation axes are randomly inclined.
Intensity contrast of solar network and faculae close to the solar limb, observed from two vantage points
The brightness of faculae and network depends on the angle at which they are observed and the magnetic flux density. Close to the limb, assessment of this relationship has until now been hindered by the increasingly lower signal in magnetograms. This preliminary study aims at highlighting the potential of using simultaneous observations from different vantage points to better determine the properties of faculae close to the limb. We use data from the Solar Orbiter/Polarimetric and Helioseismic Imager (SO/PHI), and the Solar Dynamics Observatory/Helioseismic and Magnetic Imager (SDO/HMI), recorded at \\(60^\\) angular separation of their lines of sight at the Sun. We use continuum intensity observed close to the limb by SO/PHI and complement it with the co-observed \\(B_ LOS\\) from SDO/HMI, originating closer to disc centre (as seen by SDO/HMI), thus avoiding the degradation of the magnetic field signal near the limb. We derived the dependence of facular brightness in the continuum on disc position and magnetic flux density from the combined observations of SO/PHI and SDO/HMI. Compared with a single point of view, we were able to obtain contrast values reaching closer to the limb and to lower field strengths. We find the general dependence of the limb distance at which the contrast is maximum on the flux density to be at large in line with single viewpoint observations, in that the higher the flux density is, the closer the turning point lies to the limb. There is a tendency, however, for the maximum to be reached closer to the limb when determined from two vantage points. We note that due to the preliminary nature of this study, these results must be taken with caution. Our analysis shows that studies involving two viewpoints can significantly improve the detection of faculae near the solar limb and the determination of their brightness contrast relative to the quiet Sun.