Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
874
result(s) for
"Greco, Francesco"
Sort by:
Dual-Frequency Linear-to-Circular Polarization Converter for Ka-Band Applications
2022
A dual-band linear-to-circular planar polarization converter based on a multilayer printed circuit board (PCB) is proposed and demonstrated. Each cell of the periodic surface is formed by six substrate layers separated by five foam spacers. The three top layers are identical and contain an ‘I’-type strip, while the three layers on the bottom side are realized with three identical Jerusalem crosses (JC). A linearly polarized (LP) wave tilted 45° relative to the x- and y-axis of the converter is used to illuminate the polarizer. In this configuration, right-handed circularly polarized (RHCP) waves are generated at the Ka-band while left-handed circularly polarized (LHCP) waves are generated at the K-band. An equivalent circuit model based on transmission lines is proposed and used to design the polarizer together with full-wave simulations. The simulated/measured axial ratio (AR) remains below 3 dB in the bands 19.4–21.8 GHz (12.5%) and 27.9–30.5 GHz (8.7%) with an insertion loss better than 0.5 dB.
Journal Article
Not so biodegradable: Polylactic acid and cellulose/plastic blend textiles lack fast biodegradation in marine waters
by
Greco, Francesco
,
Kogler, Michaela
,
Deheyn, Dimitri D.
in
Biodegradability
,
Biodegradable materials
,
Biodegradable Plastics
2023
The resistance of plastic textiles to environmental degradation is of major concern as large portions of these materials reach the ocean. There, they persist for undefined amounts of time, possibly causing harm and toxicity to marine ecosystems. As a solution to this problem, many compostable and so-called biodegradable materials have been developed. However, to undergo rapid biodegradation, most compostable plastics require specific conditions that are achieved only in industrial settings. Thus, industrially compostable plastics might persist as pollutants under natural conditions. In this work, we tested the biodegradability in marine waters of textiles made of polylactic acid, a diffused industrially compostable plastic. The test was extended also to cellulose-based and conventional non-biodegradable oil-based plastic textiles. The analyses were complemented by bio-reactor tests for an innovative combined approach. Results show that polylactic acid, a so-called biodegradable plastic, does not degrade in the marine environment for over 428 days. This was also observed for the oil-based polypropylene and polyethylene terephthalate, including their portions in cellulose/oil-based plastic blend textiles. In contrast, natural and regenerated cellulose fibers undergo complete biodegradation within approximately 35 days. Our results indicate that polylactic acid resists marine degradation for at least a year, and suggest that oil-based plastic/cellulose blends are a poor solution to mitigate plastic pollution. The results on polylactic acid further stress that compostability does not imply environmental degradation and that appropriate disposal management is crucial also for compostable plastics. Referring to compostable plastics as biodegradable plastics is misleading as it may convey the perception of a material that degrades in the environment. Conclusively, advances in disposable textiles should consider the environmental impact during their full life cycle, and the existence of environmentally degradable disposal should not represent an alibi for perpetuating destructive throw-away behaviors.
Journal Article
Mechanical compartmentalization of the intestinal organoid enables crypt folding and collective cell migration
2021
Intestinal organoids capture essential features of the intestinal epithelium such as crypt folding, cellular compartmentalization and collective movements. Each of these processes and their coordination require patterned forces that are at present unknown. Here we map three-dimensional cellular forces in mouse intestinal organoids grown on soft hydrogels. We show that these organoids exhibit a non-monotonic stress distribution that defines mechanical and functional compartments. The stem cell compartment pushes the extracellular matrix and folds through apical constriction, whereas the transit amplifying zone pulls the extracellular matrix and elongates through basal constriction. The size of the stem cell compartment depends on the extracellular-matrix stiffness and endogenous cellular forces. Computational modelling reveals that crypt shape and force distribution rely on cell surface tensions following cortical actomyosin density. Finally, cells are pulled out of the crypt along a gradient of increasing tension. Our study unveils how patterned forces enable compartmentalization, folding and collective migration in the intestinal epithelium.
Pérez-González et al. explore the mechanical properties of intestinal organoids, and report the existence of distinct mechanical domains and that cells are pulled out of the central crypt along a gradient of increasing tension.
Journal Article
Ultraconformable Temporary Tattoo Electrodes for Electrophysiology
by
Mattoli, Virgilio
,
Greco, Francesco
,
Esposti, Roberto
in
conformable materials
,
Electrocardiography
,
Electrodes
2018
Electrically interfacing the skin for monitoring personal health condition is the basis of skin‐contact electrophysiology. In the clinical practice the use of stiff and bulky pregelled or dry electrodes, in contrast to the soft body tissues, imposes severe restrictions to user comfort and mobility while limiting clinical applications. Here, in this work dry, unperceivable temporary tattoo electrodes are presented. Customized single or multielectrode arrays are readily fabricated by inkjet printing of conducting polymer onto commercial decal transfer paper, which allows for easy transfer on the user's skin. Conformal adhesion to the skin is provided thanks to their ultralow thickness (<1 µm). Tattoo electrode–skin contact impedance is characterized on short‐ (1 h) and long‐term (48 h) and compared with standard pregelled and dry electrodes. The viability in electrophysiology is validated by surface electromyography and electrocardiography recordings on various locations on limbs and face. A novel concept of tattoo as perforable skin‐contact electrode, through which hairs can grow, is demonstrated, thus permitting to envision very long‐term recordings on areas with high hair density. The proposed materials and patterning strategy make this technology amenable for large‐scale production of low‐cost sensing devices. Temporary tattoo electrodes are fabricated by inkjet printing and tested as unperceivable skin‐contact electrodes in various electrophysiology applications. Ultralow thickness (<1 µm) endows tattoos with conformable adhesion to skin and capability to be perforated by growing hairs. Custom multielectrodes arrays can be designed in view of specific applications in diagnostics, human machine interfacing, and personal health monitoring.
Journal Article
Low-melting point agarose as embedding medium for MALDI mass spectrometry imaging and laser-capture microdissection-based proteomics
by
Greco, Francesco
,
McDonnell, Liam Andrew
,
Botto, Asia
in
631/1647/2067
,
631/1647/245
,
631/1647/296
2023
The combination of MALDI mass spectrometry imaging, laser-capture microdissection, and quantitative proteomics allows the identification and characterization of molecularly distinct tissue compartments. Such workflows are typically performed using consecutive tissue sections, and so reliable sectioning and mounting of high-quality tissue sections is a prerequisite of such investigations. Embedding media facilitate the sectioning process but can introduce contaminants which may adversely affect either the mass spectrometry imaging or proteomics analyses. Seven low-temperature embedding media were tested in terms of embedding temperature and cutting performance. The two media that provided the best results (5% gelatin and 2% low-melting point agarose) were compared with non-embedded tissue by both MALDI mass spectrometry imaging of lipids and laser-capture microdissection followed by bottom-up proteomics. Two out of the seven tested media (5% gelatin and 2% low-melting point agarose) provided the best performances on terms of mechanical properties. These media allowed for low-temperature embedding and for the collection of high-quality consecutive sections. Comparisons with non-embedded tissues revealed that both embedding media had no discernable effect on proteomics analysis; 5% gelatin showed a light ion suppression effect in the MALDI mass spectrometry imaging experiments, 2% agarose performed similarly to the non-embedded tissue. 2% low-melting point agarose is proposed for tissue embedding in experiments involving MALDI mass spectrometry imaging of lipids and laser-capture microdissection, proteomics of consecutive tissue sections.
Journal Article
Fickian yet non-Gaussian diffusion of a quasi-2D colloidal system in an optical speckle field: experiment and simulations
by
Greco, Francesco
,
Pesce, Giuseppe
,
Pastore, Raffaele
in
639/624/1107
,
639/766/530
,
Brownian motion
2023
We investigate a quasi-2D suspension of Brownian particles in an optical speckle field produced by holographic manipulation of a laser wavefront. This system was developed to study, in a systematic and controllable way, a distinctive instance of diffusion, called Fickian yet Non Gaussian diffusion (FnGD), observed, during the last decade, for colloidal particles in a variety of complex and biological fluids. Our setup generates an optical speckle field that behaves like a disordered set of optical traps. First, we describe the experimental setup and the dynamics of the particles, focusing on mean square displacements, displacement distributions and kurtosis. Then, we present Brownian Dynamics simulations of point-like particles in a complex energy landscape, mimicking that generated by the optical speckle field. We show that our simulations can capture the salient features of the experimental results, including the emergence of FnGD, also covering times longer than the ones so far achieved in experiments. Some deviations are observed at long time only, with the Gaussian restoring being slower in simulations than in experiments. Overall, the introduced numerical model might be exploited to guide the design of upcoming experiments targeted, for example, to fully monitor the recovery of Gaussianity.
Journal Article
Preimplantation Genetic Testing: Where We Are Today
by
Minasi, Maria Giulia
,
Litwicka, Katarzyna
,
Cursio, Elisabetta
in
Biopsy
,
Chromosomes
,
Clinical outcomes
2020
Background: Preimplantation genetic testing (PGT) is widely used today in in-vitro fertilization (IVF) centers over the world for selecting euploid embryos for transfer and to improve clinical outcomes in terms of embryo implantation, clinical pregnancy, and live birth rates. Methods: We report the current knowledge concerning these procedures and the results from different clinical indications in which PGT is commonly applied. Results: This paper illustrates different molecular techniques used for this purpose and the clinical significance of the different oocyte and embryo stage (polar bodies, cleavage embryo, and blastocyst) at which it is possible to perform sampling biopsies for PGT. Finally, genetic origin and clinical significance of embryo mosaicism are illustrated. Conclusions: The preimplantation genetic testing is a valid technique to evaluated embryo euploidy and mosaicism before transfer.
Journal Article
Toward the Use of Temporary Tattoo Electrodes for Impedancemetric Respiration Monitoring and Other Electrophysiological Recordings on Skin
by
Greco, Francesco
,
Mattoli, Virgilio
,
Taccola, Silvia
in
conformable electronics
,
Electrodes
,
Epidermis
2021
The development of dry, ultra-conformable and unperceivable temporary tattoo electrodes (TTEs), based on the ink-jet printing of poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) on top of commercially available temporary tattoo paper, has gained increasing attention as a new and promising technology for electrophysiological recordings on skin. In this work, we present a TTEs epidermal sensor for real time monitoring of respiration through transthoracic impedance measurements, exploiting a new design, based on the application of soft screen printed Ag ink and magnetic interlink, that guarantees a repositionable, long-term stable and robust interconnection of TTEs with external “docking” devices. The efficiency of the TTE and the proposed interconnection strategy under stretching (up to 10%) and over time (up to 96 h) has been verified on a dedicated experimental setup and on humans, fulfilling the proposed specific application of transthoracic impedance measurements. The proposed approach makes this technology suitable for large-scale production and suitable not only for the specific use case presented, but also for real time monitoring of different bio-electric signals, as demonstrated through specific proof of concept demonstrators.
Journal Article
Conducting polymer tattoo electrodes in clinical electro- and magneto-encephalography
2020
Temporary tattoo electrodes are the most recent development in the field of cutaneous sensors. They have successfully demonstrated their performances in the monitoring of various electrophysiological signals on the skin. These epidermal electronic devices offer a conformal and imperceptible contact with the wearer while enabling good quality recordings over time. Evaluations of brain activity in clinical practice face multiple limitations, where such electrodes can provide realistic technological solutions and increase diagnostics efficiency. Here we present the performance of inkjet-printed conducting polymer tattoo electrodes in clinical electroencephalography and their compatibility with magnetoencephalography. The working mechanism of these dry sensors is investigated through the modeling of the skin/electrode impedance for better understanding of the biosignals transduction at this interface. Furthermore, a custom-made skin phantom platform demonstrates the feasibility of high-density recordings, which are essential in localizing neuropathological activities. These evaluations provide valuable input for the successful application of these ultrathin electronic tattoos sensors in multimodal brain monitoring and diagnosis.
Journal Article
Longitudinal Bottom-Up Proteomics of Serum, Serum Extracellular Vesicles, and Cerebrospinal Fluid Reveals Candidate Biomarkers for Early Detection of Glioblastoma in a Murine Model
2021
Glioblastoma Multiforme (GBM) is a brain tumor with a poor prognosis and low survival rates. GBM is diagnosed at an advanced stage, so little information is available on the early stage of the disease and few improvements have been made for earlier diagnosis. Longitudinal murine models are a promising platform for biomarker discovery as they allow access to the early stages of the disease. Nevertheless, their use in proteomics has been limited owing to the low sample amount that can be collected at each longitudinal time point. Here we used optimized microproteomics workflows to investigate longitudinal changes in the protein profile of serum, serum small extracellular vesicles (sEVs), and cerebrospinal fluid (CSF) in a GBM murine model. Baseline, pre-symptomatic, and symptomatic tumor stages were determined using non-invasive motor tests. Forty-four proteins displayed significant differences in signal intensities during GBM progression. Dysregulated proteins are involved in cell motility, cell growth, and angiogenesis. Most of the dysregulated proteins already exhibited a difference from baseline at the pre-symptomatic stage of the disease, suggesting that early effects of GBM might be detectable before symptom onset.
Journal Article