Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
21 result(s) for "Højberg, Søren"
Sort by:
Implantable loop recorder detection of atrial fibrillation to prevent stroke (The LOOP Study): a randomised controlled trial
It is unknown whether screening for atrial fibrillation and subsequent treatment with anticoagulants if atrial fibrillation is detected can prevent stroke. Continuous electrocardiographic monitoring using an implantable loop recorder (ILR) can facilitate detection of asymptomatic atrial fibrillation episodes. We aimed to investigate whether atrial fibrillation screening and use of anticoagulants can prevent stroke in individuals at high risk. We did a randomised controlled trial in four centres in Denmark. We included individuals without atrial fibrillation, aged 70–90 years, with at least one additional stroke risk factor (ie, hypertension, diabetes, previous stroke, or heart failure). Participants were randomly assigned in a 1:3 ratio to ILR monitoring or usual care (control) via an online system in permuted blocks with block sizes of four or eight participants stratified according to centre. In the ILR group, anticoagulation was recommended if atrial fibrillation episodes lasted 6 min or longer. The primary outcome was time to first stroke or systemic arterial embolism. This study is registered with ClinicalTrials.gov, NCT02036450. From Jan 31, 2014, to May 17, 2016, 6205 individuals were screened for inclusion, of whom 6004 were included and randomly assigned: 1501 (25·0%) to ILR monitoring and 4503 (75·0%) to usual care. Mean age was 74·7 years (SD 4·1), 2837 (47·3%) were women, and 5444 (90·7%) had hypertension. No participants were lost to follow-up. During a median follow-up of 64·5 months (IQR 59·3–69·8), atrial fibrillation was diagnosed in 1027 participants: 477 (31·8%) of 1501 in the ILR group versus 550 (12·2%) of 4503 in the control group (hazard ratio [HR] 3·17 [95% CI 2·81–3·59]; p<0·0001). Oral anticoagulation was initiated in 1036 participants: 445 (29·7%) in the ILR group versus 591 (13·1%) in the control group (HR 2·72 [95% CI 2·41–3·08]; p<0·0001), and the primary outcome occurred in 318 participants (315 stroke, three systemic arterial embolism): 67 (4·5%) in the ILR group versus 251 (5·6%) in the control group (HR 0·80 [95% CI 0·61–1·05]; p=0·11). Major bleeding occurred in 221 participants: 65 (4·3%) in the ILR group versus 156 (3·5%) in the control group (HR 1·26 [95% CI 0·95–1·69]; p=0·11). In individuals with stroke risk factors, ILR screening resulted in a three-times increase in atrial fibrillation detection and anticoagulation initiation but no significant reduction in the risk of stroke or systemic arterial embolism. These findings might imply that not all atrial fibrillation is worth screening for, and not all screen-detected atrial fibrillation merits anticoagulation. Innovation Fund Denmark, The Research Foundation for the Capital Region of Denmark, The Danish Heart Foundation, Aalborg University Talent Management Program, Arvid Nilssons Fond, Skibsreder Per Henriksen, R og Hustrus Fond, The AFFECT-EU Consortium (EU Horizon 2020), Læge Sophus Carl Emil Friis og hustru Olga Doris Friis' Legat, and Medtronic.
Comparison of the three-level and the five-level versions of the EQ-5D
EQ-5D is a generic instrument to measure health-related quality of life. In 2009, a new version, EQ-5D-5L, was introduced as an attempt to reduce ceiling effects and improve sensitivity to small changes over time. The objective of this study was to assess the measurement properties of the EQ-5D-5L instrument compared to the EQ-5D-3L instrument in an elderly general population with a moderate to a high degree of comorbidity. A subgroup of participants in a large clinical trial completed the EQ-5D-3L and the EQ-5D-5L questionnaires. Based on the collected data, we tested for feasibility and ceiling and floor effects. Furthermore, we assessed the redistribution properties of the responses and examined the level of inconsistency, informativity, and convergent validity. A total of 1002 persons diagnosed with hypertension, diabetes, heart failure, and/or previous stroke completed both the EQ-5D-3L and the EQ-5D-5L questionnaires. The overall ceiling effect decreased from 46% with the EQ-5D-3L to 30% with the EQ-5D-5L and absolute and relative informativity were higher for EQ-5D-5L, and there was a stronger correlation between EQ-5D-5L and EQ VAS. The EQ-5D-5L seemed to perform better than the EQ-5D-3L in terms of feasibility, ceiling effect, discriminatory power, and convergent validity. The overall ceiling effect was higher than that found in patient samples in previous studies but lower than the one found in population studies.
Potential role of conventional and speckle-tracking echocardiography in the screening of structural and functional cardiac abnormalities in elderly individuals: Baseline echocardiographic findings from the LOOP study
Elderly individuals occupy an increasing part of the general population. Conventional and speckle-tracking transthoracic echocardiography may help guide risk stratification in these individuals. The purpose of this study was to evaluate the potential utility of conventional and speckle-tracking echocardiography in the screening of cardiac abnormalities in the elderly population. Two cohorts of elderly individuals (sample size: 1441 and 944) were analyzed, who were part of a randomized controlled clinical trial (LOOP study) and of an observational study (Copenhagen City Heart Study), recruiting participants from the general population >70 years of age with cardiovascular risk factors (arterial hypertension, diabetes mellitus, heart failure, or prior stroke) and sinus rhythm. Participants underwent a comprehensive transthoracic echocardiographic examination, including myocardial speckle tracking. Cardiac abnormalities were defined according to the ASE/EACVI guidelines. Structural cardiac abnormalities such as left ventricular (LV) remodeling, mitral annular calcification (MAC), and aortic valve sclerosis (with or without stenosis) were highly prevalent in the LOOP study (40%, 39%, and 27%, respectively). Moreover, a high prevalence of functional cardiac alterations such as LV diastolic dysfunction (LVDD), abnormal LV longitudinal systolic strain (GLS), and abnormal left atrial (LA) reservoir strain was present in the LOOP study (27%, 18%, and 9%, respectively). Likewise, the rate of LVDD, abnormal GLS, and abnormal LA reservoir strain was comparable in the validation sample from the Copenhagen City Heart Study. In line with these findings, subjects with LV remodeling, MAC, and aortic valve changes had a higher prevalence of LVDD, abnormal GLS, and abnormal LA reservoir strain than those without structural cardiac alterations. The findings of this study highlight the potential clinical utility of conventional and speckle-tracking echocardiography in the screening of structural and functional cardiac abnormalities in the elderly population. Further studies are warranted to determine the prognostic relevance of these findings.
Atrial fibrillation detected by continuous electrocardiographic monitoring using implantable loop recorder to prevent stroke in individuals at risk (the LOOP study): Rationale and design of a large randomized controlled trial
Atrial fibrillation (AF) increases the rate of stroke 5-fold, and AF-related strokes have a poorer prognosis compared with non–AF-related strokes. Atrial fibrillation and stroke constitute an intensifying challenge, and health care organizations are calling for awareness on the topic. Previous studies have demonstrated that AF is often asymptomatic and consequently undiagnosed. The implantable loop recorder (ILR) allows for continuous, long-term electrocardiographic monitoring with daily transmission of arrhythmia information, potentially leading to improvement in AF detection and stroke prevention. The LOOP study is an investigator-initiated, randomized controlled trial with 6,000 participants randomized 3:1 to a control group or to receive an ILR with continuous electrocardiographic monitoring. Participants are identified from Danish registries and are eligible for inclusion if 70years or older and previously diagnosed as having at least one of the following conditions: hypertension, diabetes mellitus, heart failure, or previous stroke. Exclusion criteria include history of AF and current oral anticoagulation treatment. When an AF episode lasting ≥6minutes is detected, oral anticoagulation will be initiated according to guidelines. Expected follow-up is 4years. The primary end point is time to stroke or systemic embolism, whereas secondary end points include time to AF diagnosis and death. The LOOP study will evaluate health benefits and cost-effectiveness of ILR as a screening tool for AF to prevent stroke in patients at risk. Secondary objectives include identification of risk factors for the development of AF and characterization of arrhythmias in the population. The trial holds the potential to influence the future of stroke prevention.
Incidence and predictors of atrial fibrillation episodes as detected by implantable loop recorder in patients at risk: From the LOOP study
Recent studies have suggested a high prevalence of subclinical atrial fibrillation (AF) in various patient populations, and interest in AF screening has increased. However, knowledge about episode duration is scarce, and risk factors for short or long subclinical AF episodes have yet to be recognized. The aim of the study was to assess AF by long-term continuous screening and to investigate predictors of episodes lasting ≥6 minutes, ≥5.5 hours, or ≥24 hours, respectively. A total of 597 patients aged ≥70 years and diagnosed with ≥1 of hypertension, diabetes, previous stroke, or heart failure were recruited from the general population to receive implantable loop recorder with remote monitoring. Exclusion criteria included history of AF or cardiac implantable electronic device. AF episodes were adjudicated by senior cardiologists. During 40 (37; 42) months of continuous monitoring, AF was detected in 209 (35%) of the patients. The cumulative incidences at 3 years were 33.8% (30.2%-37.8%), 16.1% (13.4%-19.4%), and 5.7% (4.1%-7.9%) for AF episodes lasting ≥6 minutes, ≥5.5 hours, and ≥24 hours, respectively. Slower resting sinus rate and higher body mass index, N-terminal prohormone of brain natriuretic peptide, and troponin T at baseline were independently associated with AF detection. Addition of these markers to a model of sex, age, and comorbidities improved prediction of AF episodes ≥24 hours (time-dependent area under the receiver operating characteristic curve 79% vs 65%, P = .037). A considerable burden of previously unknown AF was detected when long-term monitoring was applied in at-risk patients. Biomarkers were associated with AF incidence and improved prediction of long AF episodes.
Effects of Atrial Fibrillation Screening According to Thyroid Function: Post Hoc Analysis of the Randomized LOOP Study
Subclinical thyroid dysfunction is a marker for atrial fibrillation (AF) and stroke risk. This study explored the effects of AF screening according to thyroid-stimulating hormone (TSH) levels. An AF screening trial (the LOOP study) was analyzed post hoc according to baseline TSH. The primary outcome was stroke or systemic embolism (SE). Secondary outcomes included major bleeding, all-cause death, and the combination of stroke, SE, and cardiovascular death. TSH measurements were available in 6003 of 6004 trial participants, 1500 randomized to implantable loop recorder (ILR) screening for AF and anticoagulation upon detection vs 4503 to usual care; mean age was 74.7 ± 4.1 years and 2836 (47%) were women. AF detection was approximately triple for ILR vs usual care across TSH tertiles (adjusted P interaction = 0.44). In the first tertile, screening was associated with decreased risk of the primary outcome (hazard ratio [HR] 0.52, 95% CI 0.30-0.90; P = .02) and stroke, SE, or cardiovascular death (HR 0.54, 95% CI 0.34-0.84; P = .006) compared with usual care, while no effect was observed among participants with higher TSH (adjusted P interaction .03 and .01, respectively). There was no effect on other outcomes. Analyses of continuous TSH or excluding those with abnormal TSH or thyroid medication showed similar results. AF screening and subsequent treatment was associated with decreased stroke risk among participants with low TSH, though the yield of screening was similar across TSH levels. TSH may be useful as a marker to indicate benefit from AF screening vs overdiagnosis and overtreatment. These findings should be considered exploratory and warrant further study.
Electrocardiographic Morphology-Voltage-P-Wave-Duration (MVP) Score to Select Patients for Continuous Atrial Fibrillation Screening to Prevent Stroke
Morphology-voltage-P-wave-duration (MVP) score combining P-wave duration (PWD), P-wave voltage in lead I (PWVI), and interatrial block (IAB) has been demonstrated to predict atrial fibrillation (AF). Therefore, this study aimed to examine MVP score and its P-wave components as potential predictors of AF screening effects on stroke prevention. This was a secondary analysis of the LOOP Study (Atrial Fibrillation detected by Continuous ECG Monitoring using Implantable Loop Recorder to prevent Stroke in High-risk Individuals) which randomized older persons (aged 70 to 90 years) with additional stroke risk factors to either continuous monitoring with implantable loop recorder and anticoagulation upon detection of AF episodes ≥6 minutes (the intervention group), or usual care. A total of 5,759 participants were included in the present analysis, where PWD, PWVI, and IAB were determined through a computerized analysis of 12-lead electrocardiogram and further employed to calculate baseline MVP score (0 to 6) for each participant. In total, 305 (5.3%) had stroke or systemic embolism during follow-up, with a higher risk in the group with MVP score 5 to 6 than those having score 0 to 2 (hazard ratio (HR) 1.54 [95% confidence interval (CI) 1.01 to 2.35]). This risk increase was mainly upheld by participants with IAB (HR 1.62 [95% CI 1.11 to 2.36] for IAB vs no IAB) and with longer PWD (HR 1.37 [95% CI 1.07 to 1.75] for >110 vs ≤110 ms). Compared with usual care, implantable loop recorder screening did not significantly reduce the risk of stroke or systemic embolism in any MVP risk categories (HR 0.80 [95% CI 0.60 to 1.08] for MVP score 0 to 2, 0.54 [95% CI 0.16 to 1.85] for MVP score 3 to 4, and 0.89 [95% CI 0.35 to 2.25] for MVP score 5 to 6; pinteraction = 0.78). In conclusion, a higher MVP score was associated with an increased stroke risk, but it did not demonstrate an association with effects of AF screening on stroke prevention. These findings should be considered hypothesis-generating and warrant further study.
Atrial fibrillation burden and cognitive decline in elderly patients undergoing continuous monitoring
To study the relationship between subclinical atrial fibrillation (AF) and changes in cognitive function in a large cohort of individuals with stroke risk factors. : Individuals with no prior AF diagnosis but with risk factors for stroke were recruited to undergo annual cognitive assessment with the Montreal Cognitive Assessment (MoCA) along with implantable loop recorder (ILR) monitoring for AF for 3 years. If AF episodes lasting ≥6 minutes were detected, oral anticoagulation (OAC) treatment was initiated. : A total of 1194 participants (55.2 % men, mean age 74.5 (±3.9)) had a combined duration of heart rhythm monitoring of ≈1.3 million days. Among these, 339 participants (28.3%) had adjudicated AF, with a median AF burden of 0.072% (0.02, 0.39), and 324 (96%) initiated OAC. When stratifying the participants into AF burden groups (No AF, AFlow (AF burden <0.25%), and AFhigh, (AF burden >0.25%)), only participants in the AFlow group had a decrease in MoCA score over time (P = .03), although this was not significant after adjustment for stroke risk factors. A subgroup analysis of 175 participants (14.6%) with a MoCA <26 at 3 years found no association to AF diagnosis or burden. : In a high-risk population, subclinical AF detected by continuous monitoring and subsequently treated with OAC was not associated with a significant change in MoCA score over a 3-year period.
Epicardial adipose tissue and subclinical incident atrial fibrillation as detected by continuous monitoring: a cardiac magnetic resonance imaging study
Epicardial adipose tissue (EAT) has endocrine and paracrine functions and has been associated with metabolic and cardiovascular disease. This study aimed to investigate the association between EAT, determined by cardiac magnetic resonance imaging (CMR), and incident atrial fibrillation (AF) following long-term continuous heart rhythm monitoring by implantable loop recorder (ILR). This study is a sub-study of the LOOP study. In total, 203 participants without a history of AF received an ILR and underwent advanced CMR. All participants were at least 70 years of age at inclusion and had at least one of the following conditions: hypertension, diabetes, previous stroke, or heart failure. Volumetric measurements of atrial- and ventricular EAT were derived from CMR and the time to incident AF was subsequently determined. A total of 78 participants (38%) were diagnosed with subclinical AF during a median of 40 (37–42) months of continuous monitoring. In multivariable Cox regression analyses adjusted for age, sex, and various comorbidities, we found EAT indexed to body surface area to be independently associated with the time to AF with hazard ratios (95% confidence intervals) up to 2.93 (1.36–6.34); p = 0.01 when analyzing the risk of new-onset AF episodes lasting ≥ 24 h. Atrial EAT assessed by volumetric measurements on CMR images was significantly associated with the incident AF episodes as detected by ILR.
Relationship between left atrial strain, diastolic dysfunction and subclinical atrial fibrillation in patients with cryptogenic stroke: the SURPRISE echo substudy
Paroxysmal atrial fibrillation (PAF) may be the cause of a substantial part of cryptogenic strokes (CS). Echocardiography could assist risk stratification for PAF to select patients in need of prolonged rhythm monitoring. We aimed to assess the value of left atrial (LA) strain and a revised diastolic dysfunction (DDF) model with LA strain for predicting PAF. This was a prospective study of 56 CS patients who had a cardiac monitor implanted for 3 year monitoring for PAF, and an echocardiogram performed prior to monitoring. Conventional echocardiography, global longitudinal strain (GLS) and LA strain were performed. LA speckle tracking provided the LA reservoir strain (LAs). Patients were stratified into high versus low LAs by ROC curves (28.2%), and this cut-off was used to refine DDF grading. During follow-up of median 20 months, 13 (23%) patients were diagnosed with PAF. No conventional echocardiographic parameters differed between patients who developed PAF and those without PAF. However, LAs was significantly impaired in PAF patients (LAs: 30 vs. 27% for non-PAF and PAF, p = 0.046). Low LAs significantly predicted PAF independent of LA volume and GLS [OR 5.88 (1.30; 26.55), p = 0.021]. Revised DDF grading significantly predicted PAF, even when adjusted for the CHADS2 risk-score (OR 1.88 [1.01;3.50], per increase in DDF grade, p for trend = 0.047), which was not the case for conventional DDF grading. In conclusion, LAs associates with PAF independent of GLS and LA size, and may be used to improve the performance of DDF grading for identifying PAF in CS patients.