Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
933 result(s) for "Haney, C."
Sort by:
European Association for Endoscopic Surgery (EAES) consensus on Indocyanine Green (ICG) fluorescence-guided surgery
BackgroundIn recent years, the use of Indocyanine Green (ICG) fluorescence-guided surgery during open and laparoscopic procedures has exponentially expanded across various clinical settings. The European Association of Endoscopic Surgery (EAES) initiated a consensus development conference on this topic with the aim of creating evidence-based statements and recommendations for the surgical community.MethodsAn expert panel of surgeons has been selected and invited to participate to this project. Systematic reviews of the PubMed, Embase and Cochrane libraries were performed to identify evidence on potential benefits of ICG fluorescence-guided surgery on clinical practice and patient outcomes. Statements and recommendations were prepared and unanimously agreed by the panel; they were then submitted to all EAES members through a two-rounds online survey and results presented at the EAES annual congress, Barcelona, November 2021.ResultsA total of 18,273 abstracts were screened with 117 articles included. 22 statements and 16 recommendations were generated and approved. In some areas, such as the use of ICG fluorescence-guided surgery during laparoscopic cholecystectomy, the perfusion assessment in colorectal surgery and the search for the sentinel lymph nodes in gynaecological malignancies, the large number of evidences in literature has allowed us to strongly recommend the use of ICG for a better anatomical definition and a reduction in post-operative complications.ConclusionsOverall, from the systematic literature review performed by the experts panel and the survey extended to all EAES members, ICG fluorescence-guided surgery could be considered a safe and effective technology. Future robust clinical research is required to specifically validate multiple organ-specific applications and the potential benefits of this technique on clinical outcomes.
Functional outcomes after laparoscopic versus robotic-assisted rectal resection: a systematic review and meta-analysis
Surgical resection is crucial for curative treatment of rectal cancer. Through multidisciplinary treatment, including radiochemotherapy and total mesorectal excision, survival has improved substantially. Consequently, more patients have to deal with side effects of treatment. The most recently introduced surgical technique is robotic-assisted surgery (RAS) which seems equally effective in terms of oncological control compared to laparoscopy. However, RAS enables further advantages which maximize the precision of surgery, thus providing better functional outcomes such as sexual function or contience without compromising oncological results. This review was done according to the PRISMA and AMSTAR-II guidelines and registered with PROSPERO (CRD42018104519). The search was planned with PICO criteria and conducted on Medline, Web of Science and CENTRAL. All screening steps were performed by two independent reviewers. Inclusion criteria were original, comparative studies for laparoscopy vs. RAS for rectal cancer and reporting of functional outcomes. Quality was assessed with the Newcastle–Ottawa scale. The search retrieved 9703 hits, of which 51 studies with 24,319 patients were included. There was a lower rate of urinary retention (non-RCTs: Odds ratio (OR) [95% Confidence Interval (CI)] 0.65 [0.46, 0.92]; RCTs: OR[CI] 1.29[0.08, 21.47]), ileus (non-RCTs: OR[CI] 0.86[0.75, 0.98]; RCTs: OR[CI] 0.80[0.33, 1.93]), less urinary symptoms (non-RCTs mean difference (MD) [CI] − 0.60 [− 1.17, − 0.03]; RCTs: − 1.37 [− 4.18, 1.44]), and higher quality of life for RAS (only non-RCTs: MD[CI]: 2.99 [2.02, 3.95]). No significant differences were found for sexual function (non-RCTs: standardized MD[CI]: 0.46[− 0.13, 1.04]; RCTs: SMD[CI]: 0.09[− 0.14, 0.31]). The current meta-analysis suggests potential benefits for RAS over laparoscopy in terms of functional outcomes after rectal cancer resection. The current evidence is limited due to non-randomized controlled trials and reporting of functional outcomes as secondary endpoints.
Spectral characterization of intraoperative renal perfusion using hyperspectral imaging and artificial intelligence
Accurate intraoperative assessment of organ perfusion is a pivotal determinant in preserving organ function e.g. during kidney surgery including partial nephrectomy or kidney transplantation. Hyperspectral imaging (HSI) has great potential to objectively describe and quantify this perfusion as opposed to conventional surrogate techniques such as ultrasound flowmeter, indocyanine green or the subjective eye of the surgeon. An established live porcine model under general anesthesia received median laparotomy and renal mobilization. Different scenarios that were measured using HSI were (1) complete, (2) gradual and (3) partial malperfusion. The differences in spectral reflectance as well as HSI oxygenation (StO 2 ) between different perfusion states were compelling and as high as 56.9% with 70.3% (± 11.0%) for “physiological” vs. 13.4% (± 3.1%) for “venous congestion”. A machine learning (ML) algorithm was able to distinguish between these perfusion states with a balanced prediction accuracy of 97.8%. Data from this porcine study including 1300 recordings across 57 individuals was compared to a human dataset of 104 recordings across 17 individuals suggesting clinical transferability. Therefore, HSI is a highly promising tool for intraoperative microvascular evaluation of perfusion states with great advantages over existing surrogate techniques. Clinical trials are required to prove patient benefit.
Serious gaming and virtual reality in the multimodal training of laparoscopic inguinal hernia repair: a randomized crossover study
BackgroundThe aim of this study was to assess the transferability of surgical skills for the laparoscopic hernia module between the serious game Touch Surgery™ (TS) and the virtual reality (VR) trainer Lap Mentor™. Furthermore, this study aimed to collect validity evidence and to discuss “sources of validity evidence” for the findings using the laparoscopic inguinal hernia module on TS.MethodsIn a randomized crossover study, medical students (n = 40) in their clinical years performed laparoscopic inguinal hernia modules on TS and the VR trainer. TS group started with “Laparoscopic Inguinal Hernia Module” on TS (phase 1: Preparation, phase 2: Port Placement and Hernia Repair), performed the module first in training, then in test mode until proficiency was reached. VR group started with “Inguinal Hernia Module” on the VR trainer (task 1: Anatomy Identification, task 2: Incision and Dissection) and also performed the module until proficiency. Once proficiency reached in the first modality, the groups performed the other training modality until reaching proficiency. Primary endpoint was the number of attempts needed to achieve proficiency for each group for each task/phase.ResultsStudents starting with TS needed significantly less attempts to reach proficiency for task 1 on the VR trainer than students who started with the VR trainer (TS = 2.7 ± 0.6 vs. VR = 3.2 ± 0.7; p = 0.028). No significant differences for task 2 were observed between groups (TS = 2.3 ± 1.1 vs. VR = 2.1 ± 0.8; p = 0.524). For both phases on TS, no significant skill transfer from the VR trainer to TS was observed. Aspects of validity evidence for the module on TS were collected.ConclusionThe results show that TS brought additional benefit to improve performances on the VR trainer for task 1 but not for task 2. Skill transfer from the VR trainer to TS could not be shown. VR and TS should thus be used in combination with TS first in multimodal training to ensure optimal training conditions.
Robotic-assisted cholecystectomy is superior to laparoscopic cholecystectomy in the initial training for surgical novices in an ex vivo porcine model: a randomized crossover study
BackgroundRobotic-assisted surgery (RAS) potentially reduces workload and shortens the surgical learning curve compared to conventional laparoscopy (CL). The present study aimed to compare robotic-assisted cholecystectomy (RAC) to laparoscopic cholecystectomy (LC) in the initial learning phase for novices.MethodsIn a randomized crossover study, medical students (n = 40) in their clinical years performed both LC and RAC on a cadaveric porcine model. After standardized instructions and basic skill training, group 1 started with RAC and then performed LC, while group 2 started with LC and then performed RAC. The primary endpoint was surgical performance measured with Objective Structured Assessment of Technical Skills (OSATS) score, secondary endpoints included operating time, complications (liver damage, gallbladder perforations, vessel damage), force applied to tissue, and subjective workload assessment.ResultsSurgical performance was better for RAC than for LC for total OSATS (RAC = 77.4 ± 7.9 vs. LC = 73.8 ± 9.4; p = 0.025, global OSATS (RAC = 27.2 ± 1.0 vs. LC = 26.5 ± 1.6; p = 0.012, and task specific OSATS score (RAC = 50.5 ± 7.5 vs. LC = 47.1 ± 8.5; p = 0.037). There were less complications with RAC than with LC (10 (25.6%) vs. 26 (65.0%), p = 0.006) but no difference in operating times (RAC = 77.0 ± 15.3 vs. LC = 75.5 ± 15.3 min; p = 0.517). Force applied to tissue was similar. Students found RAC less physical demanding and less frustrating than LC.ConclusionsNovices performed their first cholecystectomies with better performance and less complications with RAS than with CL, while operating time showed no differences. Students perceived less subjective workload for RAS than for CL. Unlike our expectations, the lack of haptic feedback on the robotic system did not lead to higher force application during RAC than LC and did not increase tissue damage. These results show potential advantages for RAS over CL for surgical novices while performing their first RAC and LC using an ex vivo cadaveric porcine model.Registration numberresearchregistry6029Graphic abstract
Endoscopic versus surgical treatment for infected necrotizing pancreatitis: a systematic review and meta-analysis of randomized controlled trials
ObjectiveTo compare outcomes of endoscopic and surgical treatment for infected necrotizing pancreatitis (INP) based on results of randomized controlled trials (RCT).BackgroundTreatment of INP has changed in the last two decades with adoption of interventional, endoscopic and minimally invasive surgical procedures for drainage and necrosectomy. However, this relies mostly on observational studies.MethodsWe performed a systematic review following Cochrane and PRISMA guidelines and AMSTAR-2 criteria and searched CENTRAL, Medline and Web of Science. Randomized controlled trails that compared an endoscopic treatment to a surgical treatment for patients with infected walled-off necrosis and included one of the main outcomes were eligible for inclusion. The main outcomes were mortality and new onset multiple organ failure. Prospero registration ID: CRD42019126033ResultsThree RCTs with 190 patients were included. Intention to treat analysis showed no difference in mortality. However, patients in the endoscopic group had statistically significant lower odds of experiencing new onset multiple organ failure (odds ratio (OR) confidence interval [CI] 0.31 [0.10, 0.98]) and were statistically less likely to suffer from perforations of visceral organs or enterocutaneous fistulae (OR [CI] 0.31 [0.10, 0.93]), and pancreatic fistulae (OR [CI] 0.09 [0.03, 0.28]). Patients with endoscopic treatment had a statistically significant lower mean hospital stay (Mean difference [CI] − 7.86 days [− 14.49, − 1.22]). No differences in bleeding requiring intervention, incisional hernia, exocrine or endocrine insufficiency or ICU stay were apparent. Overall certainty of evidence was moderate.ConclusionThere seem to be possible benefits of endoscopic treatment procedure. Given the heterogenous procedures in the surgical group as well as the low amount of randomized evidence, further studies are needed to evaluate the combination of different approaches and appropriate timepoints for interventions.
In-Flight Calibration and Performance of the OSIRIS-REx Touch And Go Camera System (TAGCAMS)
The Touch And Go Camera System (TAGCAMS) is a three-camera-head instrument onboard NASA’s OSIRIS-REx asteroid sample return mission spacecraft. The purpose of TAGCAMS is to facilitate navigation to the target asteroid, (101955) Bennu; confirm acquisition of the asteroid sample; document asteroid sample stowage; and provide supplementary imaging for OSIRIS-REx science investigations. During the almost two-year OSIRIS-REx outbound cruise phase we pursued nine TAGCAMS imaging campaigns to check, calibrate and characterize the camera system’s performance before asteroid arrival and proximity operations began in late 2018. The TAGCAMS in-flight calibration dataset provides the relevant information to enable the three cameras to complete their primary observation goals during asteroid operations. The key performance parameters that we investigated in flight included: linearity, responsivity (both point source and extended body), dark current, hot pixels, pointing, image geometry transformation, image quality and stray light. Analyses of the in-flight performance either confirmed the continued applicability of the TAGCAMS ground test results or substantially improved upon the ground test knowledge. In addition, the TAGCAMS calibration observations identified the source of a spacecraft outgassing feature that guided successful remediation efforts prior to asteroid arrival.
Safety of dobutamine or adenosine stress cardiac magnetic resonance imaging in patients with left ventricular thrombus
BackgroundLeft ventricular (LV) thrombus formation is a common but potentially serious complication, typically occurring after myocardial infarction. Due to perceived high thromboembolic risk and lack of safety data, stress cardiac magnetic resonance (CMR) imaging especially with dobutamine is usually avoided despite its high diagnostic yield. This study aimed to investigate the characteristics, safety and outcome of patients with LV thrombus undergoing dobutamine or vasodilator stress CMR.MethodsPatients undergoing stress CMR with concomitant LV thrombus were retrospectively included. Risk factors, comorbidities, and previous embolic events were recorded. Periprocedural safety was assessed for up to 48 h following the examination. Major adverse cardiac events (MACE) 12 months before the diagnosis were compared to 12 months after the exam and between patients and a matched control group. Additionally, patients were followed up for all-cause mortality.Results95 patients (78 male, 65 ± 10.7 years) were included. Among them, 43 patients underwent dobutamine (36 high-dose, 7 low-dose) and 52 vasodilator stress CMR. Periprocedural safety was excellent with no adverse events. During a period of 24 months, 27 MACE (14.7%) occurred in patients and controls with no statistical difference between groups. During a median follow-up of 33.7 months (IQR 37.6 months), 6 deaths (6.3%) occurred. Type of stress agent, thrombus mobility, or protrusion were not correlated to embolic events or death.ConclusionThe addition of a stress test to a CMR exam is safe and does increase the generally high cardioembolic event rate in LV thrombus patients. Therefore, it is useful to support reperfusion decision-making.
Machine learning enables automated screening for systematic reviews and meta-analysis in urology
Purpose To investigate and implement semiautomated screening for meta-analyses (MA) in urology under consideration of class imbalance. Methods Machine learning algorithms were trained on data from three MA with detailed information of the screening process. Different methods to account for class imbalance (Sampling (up- and downsampling, weighting and cost-sensitive learning), thresholding) were implemented in different machine learning (ML) algorithms (Random Forest, Logistic Regression with Elastic Net Regularization, Support Vector Machines). Models were optimized for sensitivity. Besides metrics such as specificity, receiver operating curves, total missed studies, and work saved over sampling were calculated. Results During training, models trained after downsampling achieved the best results consistently among all algorithms. Computing time ranged between 251 and 5834 s. However, when evaluated on the final test data set, the weighting approach performed best. In addition, thresholding helped to improve results as compared to the standard of 0.5. However, due to heterogeneity of results no clear recommendation can be made for a universal sample size. Misses of relevant studies were 0 for the optimized models except for one review. Conclusion It will be necessary to design a holistic methodology that implements the presented methods in a practical manner, but also takes into account other algorithms and the most sophisticated methods for text preprocessing. In addition, the different methods of a cost-sensitive learning approach can be the subject of further investigations.
Pelagic seabird density and vulnerability in the Gulf of Mexico to oiling from the Deepwater Horizon/MC-252 spill
Using ship-based surveys, the Natural Resource Damage Assessment (NRDA) Trustees assessed the external oiling of offshore and pelagic marine birds inhabiting the northern Gulf of Mexico (Gulf) in the year following the Deepwater Horizon oil spill (DWH spill). Study objectives were to (1) collect data on pelagic seabirds that were visibly oiled, (2) collect data to estimate abundance of seabirds in offshore and pelagic waters, and 3) document the location and condition of any bird carcasses encountered. Methods employed included strip line transects and station point counts. Surveys were conducted within a study area bound by the Texas-Mexico border and the Dry Tortugas of Florida to the south, and the nearshore coastal waters of the northern Gulf of Mexico. A total of 5665 strip line transects and 386 station point-counts of variable duration were collected during the study. More than 23,000 individual seabirds comprising 45 estuarine, coastal, offshore, and pelagic species were tallied. Average daily abundance of seabirds detected varied from a low of approximately 7 birds/day in November 2010 along regions of the mid- and outer continental shelf to a high of more than 580 birds/day in June 2011 within the near-shore, coastal waters of the northern Gulf.