Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
7
result(s) for
"Heckova, Eva"
Sort by:
Hippocampal GABA levels correlate with retrieval performance in an associative learning paradigm
by
Basaran, Alim
,
Michenthaler, Paul
,
Seiger, Rene
in
Adult
,
Association Learning - physiology
,
Associative learning
2020
Neural plasticity is a complex process dependent on neurochemical underpinnings. Next to the glutamatergic system which contributes to memory formation via long-term potentiation (LTP) and long-term depression (LTD), the main inhibitory neurotransmitter, GABA is crucially involved in neuroplastic processes. Hence, we investigated changes in glutamate and GABA levels in the brain in healthy participants performing an associative learning paradigm.
Twenty healthy participants (10 female, 25 ± 5 years) underwent paired multi-voxel magnetic resonance spectroscopy imaging before and after completing 21 days of a facial associative learning paradigm in a longitudinal study design. Changes of GABA and glutamate were compared to retrieval success in the hippocampus, insula and thalamus.
No changes in GABA and glutamate concentration were found after 21 days of associative learning. However, baseline hippocampal GABA levels were significantly correlated with initial retrieval success (pcor = 0.013, r = 0.690). In contrast to the thalamus and insula (pcor>0.1), higher baseline GABA levels in the hippocampus were associated with better retrieval performance in an associative learning paradigm.
Therefore, our findings support the importance of hippocampal GABA levels in memory formation in the human brain in vivo.
∙Hippocampal GABA levels correlate with retrieval performance.∙No changes of GABA and glutamate levels after three weeks of associative learning.∙Baseline glutamate levels show no correlations with retrieval success.∙High GABA levels in the hippocampus show positive effects on retrieval performance.
Journal Article
Automated ROI-Based Labeling for Multi-Voxel Magnetic Resonance Spectroscopy Data Using FreeSurfer
2019
: Advanced analysis methods for multi-voxel magnetic resonance spectroscopy (MRS) are crucial for neurotransmitter quantification, especially for neurotransmitters showing different distributions across tissue types. So far, only a handful of studies have used region of interest (ROI)-based labeling approaches for multi-voxel MRS data. Hence, this study aims to provide an automated ROI-based labeling tool for 3D-multi-voxel MRS data.
: MRS data, for automated ROI-based labeling, was acquired in two different spatial resolutions using a spiral-encoded, LASER-localized 3D-MRS imaging sequence with and without MEGA-editing. To calculate the mean metabolite distribution within selected ROIs, masks of individual brain regions were extracted from structural T
-weighted images using FreeSurfer. For reliability testing of automated labeling a comparison to manual labeling and single voxel selection approaches was performed for six different subcortical regions.
: Automated ROI-based labeling showed high consistency [intra-class correlation coefficient (ICC) > 0.8] for all regions compared to manual labeling. Higher variation was shown when selected voxels, chosen from a multi-voxel grid, uncorrected for voxel composition, were compared to labeling methods using spatial averaging based on anatomical features within gray matter (GM) volumes.
: We provide an automated ROI-based analysis approach for various types of 3D-multi-voxel MRS data, which dramatically reduces hands-on time compared to manual labeling without any possible inter-rater bias.
Journal Article
Cardiac autonomic function in patients with early multiple sclerosis
by
Vlcek, Miroslav
,
Havranova, Andrea
,
Siarnik, Pavel
in
Autonomic nervous system
,
Baroreceptors
,
Blood pressure
2021
PurposeCardiac autonomic dysfunction has been reported in patients with long-standing multiple sclerosis (MS); however, data in early disease are limited. The present study was aimed at evaluating cardiac autonomic function in patients with early MS in the context of white matter metabolic status, which could potentially affect functions of the autonomic brain centers.MethodsCardiac sympathetic and baroreflex cardiovagal responses to the Valsalva maneuver, orthostatic test, and the Stroop test were evaluated in 16 early, treatment-naïve patients with relapsing–remitting MS, and in 14 healthy participants. Proton magnetic resonance spectroscopic imaging (MRSI) of the brain was performed in eight of these MS patients and in eight controls.ResultsValsalva maneuver outcomes were comparable between patients and controls. At baseline, norepinephrine levels were lower (p = 0.027) in MS patients compared to controls. The patients had higher heart rate (p = 0.034) and lower stroke volume (p = 0.008), but similar blood pressure, cardiac output and norepinephrine increments from baseline to 2 min of the orthostatic test compared to controls. MS patients and controls did not differ in responses to the Stroop test. MRSI showed lower total N-acetylaspartate/total creatine (p = 0.038) and higher myo-inositol/total creatine (p = 0.013) in MS lesions compared to non-lesional white matter.ConclusionOur results show normal cardiac sympathetic and baroreflex cardiovagal function in MS patients with relapsing–remitting MS with lesions at the post-acute/early resolving stage.Trial registrationThe study was registered at ClinicalTrials.gov under the Identifier: NCT 03052595 and complies with the STROBE checklist for cohort, case–control, and cross-sectional studies.
Journal Article
High-resolution metabolic mapping of gliomas via patch-based super-resolution magnetic resonance spectroscopic imaging at 7T
by
Roetzer, Thomas
,
Springer, Elisabeth
,
Strasser, Bernhard
in
Adult
,
Brain cancer
,
Brain Neoplasms - diagnostic imaging
2019
To demonstrate the feasibility of 7 T magnetic resonance spectroscopic imaging (MRSI), combined with patch-based super-resolution (PBSR) reconstruction, for high-resolution multi-metabolite mapping of gliomas.
Ten patients with WHO grade II, III and IV gliomas (6/4, male/female; 45 ± 9 years old) were prospectively measured between 2014 and 2018 on a 7 T whole-body MR imager after routine 3 T magnetic resonance imaging (MRI) and positron emission tomography (PET). Free induction decay MRSI with a 64 × 64-matrix and a nominal voxel size of 3.4 × 3.4 × 8 mm³ was acquired in six minutes, along with standard T1/T2-weighted MRI. Metabolic maps were obtained via spectral LCmodel processing and reconstructed to 0.9 × 0.9 × 8 mm³ resolutions via PBSR.
Metabolite maps obtained from combined 7 T MRSI and PBSR resolved the density of metabolic activity in the gliomas in unprecedented detail. Particularly in the more heterogeneous cases (e.g. post resection), metabolite maps enabled the identification of complex metabolic activities, which were in topographic agreement with PET enhancement.
PBSR-MRSI combines the benefits of ultra-high-field MR systems, cutting-edge MRSI, and advanced postprocessing to allow millimetric resolution molecular imaging of glioma tissue beyond standard methods. An ideal example is the accurate imaging of glutamine, which is a prime target of modern therapeutic approaches, made possible due to the higher spectral resolution of 7 T systems.
[Display omitted]
•Millimetric MRSI maps resolved the metabolic activity of gliomas in unprecedented detail.•We found complex metabolic alterations outside morphologically visible deviations.•Gln, of recent attention in tumor metabolism, could be reliably separated from Glu.
Journal Article
Ultra-high resolution brain metabolite mapping at 7 T by short-TR Hadamard-encoded FID-MRSI
by
Trattnig, Siegfried
,
Heckova, Eva
,
Strasser, Bernhard
in
Adult
,
Brain
,
Brain - diagnostic imaging
2018
MRSI in the brain at ≥7 T is a technique of great promise, but has been limited mainly by low B0/B1+-homogeneity, specific absorption rate restrictions, long measurement times, and low spatial resolution. To overcome these limitations, we propose an ultra-high resolution (UHR) MRSI sequence that provides a 128×128 matrix with a nominal voxel volume of 1.7×1.7×8mm3 in a comparatively short measurement time. A clinically feasible scan time of 10–20min is reached via a short TR of 200 ms due to an optimised free induction decay-based acquisition with shortened water suppression as well as parallel imaging (PI) using Controlled Aliasing In Parallel Imaging Results IN Higher Acceleration (CAIPIRINHA). This approach is not limited to a rectangular region of interest in the centre of the brain, but also covers cortical brain regions. Transversal pulse-cascaded Hadamard encoding was able to further extend the coverage to 3D-UHR-MRSI of four slices (100×100×4 matrix size), with a measurement time of 17min. Lipid contamination was removed during post-processing using L2-regularisation. Simulations, phantom and volunteer measurements were performed. The obtained single-slice and 3D-metabolite maps show the brain in unprecedented detail (e.g., hemispheres, ventricles, gyri, and the contrast between grey and white matter). This facilitates the use of UHR-MRSI for clinical applications, such as measurements of the small structures and metabolic pathologic deviations found in small Multiple Sclerosis lesions.
[Display omitted]
•Ultra-high resolution MRSI (128×128 in-plane matrix) at 7 T.•Parallel imaging and short TR of 200ms make UHR-MRSI clinically feasible (10–20min).•Pulse-cascaded Hadamard encoding provides 3D-MRSI coverage.
Journal Article
Frequency drift in MR spectroscopy at 3T
by
Dydak, Ulrike
,
Yeung, David K.W.
,
Swinnen, Stephan P.
in
Bandwidths
,
Brain - diagnostic imaging
,
Brain - metabolism
2021
Heating of gradient coils and passive shim components is a common cause of instability in the B0 field, especially when gradient intensive sequences are used. The aim of the study was to set a benchmark for typical drift encountered during MR spectroscopy (MRS) to assess the need for real-time field-frequency locking on MRI scanners by comparing field drift data from a large number of sites.
A standardized protocol was developed for 80 participating sites using 99 3T MR scanners from 3 major vendors. Phantom water signals were acquired before and after an EPI sequence. The protocol consisted of: minimal preparatory imaging; a short pre-fMRI PRESS; a ten-minute fMRI acquisition; and a long post-fMRI PRESS acquisition. Both pre- and post-fMRI PRESS were non-water suppressed. Real-time frequency stabilization/adjustment was switched off when appropriate. Sixty scanners repeated the protocol for a second dataset. In addition, a three-hour post-fMRI MRS acquisition was performed at one site to observe change of gradient temperature and drift rate. Spectral analysis was performed using MATLAB. Frequency drift in pre-fMRI PRESS data were compared with the first 5:20 minutes and the full 30:00 minutes of data after fMRI. Median (interquartile range) drifts were measured and showed in violin plot. Paired t-tests were performed to compare frequency drift pre- and post-fMRI. A simulated in vivo spectrum was generated using FID-A to visualize the effect of the observed frequency drifts. The simulated spectrum was convolved with the frequency trace for the most extreme cases. Impacts of frequency drifts on NAA and GABA were also simulated as a function of linear drift. Data from the repeated protocol were compared with the corresponding first dataset using Pearson's and intraclass correlation coefficients (ICC).
Of the data collected from 99 scanners, 4 were excluded due to various reasons. Thus, data from 95 scanners were ultimately analyzed. For the first 5:20 min (64 transients), median (interquartile range) drift was 0.44 (1.29) Hz before fMRI and 0.83 (1.29) Hz after. This increased to 3.15 (4.02) Hz for the full 30 min (360 transients) run. Average drift rates were 0.29 Hz/min before fMRI and 0.43 Hz/min after. Paired t-tests indicated that drift increased after fMRI, as expected (p < 0.05). Simulated spectra convolved with the frequency drift showed that the intensity of the NAA singlet was reduced by up to 26%, 44 % and 18% for GE, Philips and Siemens scanners after fMRI, respectively. ICCs indicated good agreement between datasets acquired on separate days. The single site long acquisition showed drift rate was reduced to 0.03 Hz/min approximately three hours after fMRI.
This study analyzed frequency drift data from 95 3T MRI scanners. Median levels of drift were relatively low (5-min average under 1 Hz), but the most extreme cases suffered from higher levels of drift. The extent of drift varied across scanners which both linear and nonlinear drifts were observed.
Journal Article
CROSS-BORDER MERGERS AND ACQUISITIONS AS EFFICIENT MANAGENT TOOL OF CAPITAL ALLOCATION WITHIN EUROPEAN AREA
Liberalization of international capital movements, new investment incentives and economic integration has promoted the rapid increase and spread of cross-border mergers and acquisitions in recent years. The aim of contribution is to analyze the relationships between volume of M&As in selected countries of the European area and in Turkey and their three determinants using linear quantile regression model. We identify some of the main forces driving M&As, using a unique database on bilateral cross-border M&As at sectoral level in manufacturing and services over the period 1998-2012. Our empirical results suggest that stock market developments, profitability and trade integration are important drivers of M&As (as efficient cross-country allocation of capital) regardless of their nature.
Journal Article