Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
75 result(s) for "Heo, Jae-Won"
Sort by:
Clinical and Radiological Outcomes of Meniscal Repair Versus Partial Meniscectomy for Medial Meniscus Root Tears: A Systematic Review and Meta-analysis
Background: Given the superiority of meniscal repair over partial meniscectomy according to biomechanical data, the clinical outcomes of meniscal repair are likely to be better than those of partial meniscectomy for a medial meniscus root tear (MMRT). Purpose/Hypothesis: This review was designed to compare the clinical and radiological results between meniscal repair and partial meniscectomy for MMRTs. It was hypothesized that meniscal repair would result in better clinical and radiological results compared with partial meniscectomy. Study Design: Systematic review; Level of evidence, 4. Methods: Studies were included in the review if they (1) included patients with MMRTs who underwent primary arthroscopic meniscal repair or partial meniscectomy and (2) analyzed validated patient-reported outcomes and/or radiological evaluations. Summary odds ratios (ORs) with 95% CIs were calculated to compare partial meniscectomy with meniscal repair for each outcome. Results: A total of 13 studies were included. The mean duration of follow-up was 33.5 and 47.2 months in the meniscal repair group and partial meniscectomy group, respectively. The change in the Lysholm score from preoperatively to postoperatively was statistically significantly in favor of meniscal repair (OR, 2.20 [95% CI, 1.55-3.12]), while no difference was found with respect to the change in the Tegner score between the 2 surgical approaches (OR, 1.21 [95% CI, 0.65-2.24]). The prevalence of postoperative severe knee osteoarthritis (OR, 0.31 [95% CI, 0.17-0.54]) as well as that of reoperations (OR, 0.05 [95% CI, 0.01-0.19]) were significantly in favor of meniscal repair. Conclusion Better outcomes were seen after meniscal repair compared with partial meniscectomy for MMRTs, with greater improvements in Lysholm scores, and lower rates of progression to knee osteoarthritis, and lower reoperation rate.
Transcriptome Analysis of Platelet‐Rich Plasma–Treated Osteoarthritic Chondrocyte
As a blood‐derived biomaterial, platelet‐rich plasma (PRP) has been considered a potential therapy and tried in knee and hip osteoarthritis with beneficial effects as an anti‐inflammatory and potent regenerative agent. To better understand the substantial effect of PRP on chondrocytes in an inflammatory environment, we analyzed the transcriptome profile by RNA sequencing (RNA‐seq) after PRP administration in IL‐1 β ‐treated osteoarthritic chondrocytes which were isolated from human knee articular cartilage tissue. A total of 24,424 genes were analyzed, and significant changes in expression were observed for 226 genes in the control (CTL) versus IL‐1 β group and 300 genes in the IL‐1 β versus IL‐1 β +PRP group. The Top 20 significantly upregulated and downregulated genes and the major altered genes in nine categories that are closely related to chondrocyte physiology were analyzed, and the expression of several important genes in each category was evaluated by qRT‐PCR and western blot analysis. Our study revealed that the PRP, at the gene expression level, has apparent anti‐inflammatory, cell proliferative, and regenerative activities in chondrocytes in the presence of IL‐1 β , which mimic an osteoarthritic environment. Identifying potent molecules that regulate cartilage physiology represents a promising therapeutic approach for suppressing cartilage degeneration, especially that caused by inflammation‐induced osteoarthritis.
Clinical and Radiological Outcomes After Autologous Matrix-Induced Chondrogenesis Versus Microfracture of the Knee: A Systematic Review and Meta-analysis With a Minimum 2-Year Follow-up
Background: Microfracture (MFx) is the most common procedure for treating chondral lesions in the knee; however, initial improvements decline after 2 years. Autologous matrix-induced chondrogenesis (AMIC) may overcome this shortcoming by combining MFx with collagen scaffolds. However, the outcomes of AMIC and MFx in the knee have not been compared. Purpose: To compare the clinical and radiological outcomes of AMIC and MFx over a minimum 2-year follow-up. Study Design: Systematic review; Level of evidence, 4. Methods: A systematic search of the MEDLINE, Embase, and Cochrane Library databases identified studies of patients who underwent AMIC or MFx and that reported validated clinical outcome measure and/or radiological evaluation findings at a follow-up of ≥2 years. There were 2 reviewers who performed study selection, a risk of bias assessment, and data extraction. Results: Overall, 29 studies were included in this systematic review. The mean improvement on the Lysholm score, Tegner activity scale, and visual analog scale for pain did not differ significantly between the 2 procedures. The mean improvement on the International Knee Documentation Committee (IKDC) subjective score was significantly greater in the AMIC (45.9 [95% CI, 36.2-55.5]) than in the MFx (27.2 [95% CI, 23.3-31.1]) group (P < .001). In addition, the mean magnetic resonance observation of cartilage repair tissue score was significantly higher in the AMIC (69.3 [95% CI, 55.1-83.5]) versus MFx (41.0 [95% CI, 27.3-54.7]) group (P = .005), and the mean adequate defect filling rate on magnetic resonance imaging scans was significantly better in the AMIC (77.3% [95% CI, 66.7%-87.9%]) versus MFx (47.9% [95% CI, 29.2%-66.6%]) group (P = .008) (odds ratio, 1.58 [95% CI, 1.07-2.33]). Conclusion: No significant differences in clinical outcomes, except for the IKDC subjective score, were found between the AMIC and MFx groups. Greater improvement in IKDC subjective scores and magnetic resonance imaging findings were seen in patients treated with AMIC compared with MFx at a minimum 2-year follow-up.
Synthesis of functional chalcogenide materials for memory/sensing devices and their integration into artificial sensory systems
With distinctive phase-change and switching properties, chalcogenide materials have emerged as critical components in various cutting-edge technologies. This review attempts to provide an overview of chalcogenide materials, from their fundamental properties to their diverse applications with focus on memory and sensing technologies, which are indispensable components in human-like electronic artificial sensory systems. After reviewing the synthesis and application of chalcogenide materials with respect to dimensionality, we focus on the key advances in (1) memory devices, including phase-change memory (PCM), ovonic threshold switching (OTS) selectors, and selector-only memory (SOM), and (2) sensing devices, including optical sensors, gas sensors, and neuromorphic sensors. Emphasis will be given on how chalcogenide materials can be integrated into next-generation systems, such as wearable platforms, artificial intelligence, and neuromorphic/quantum computing systems, to meet the growing demands for high-performance memory and multi-functional sensing. We also provide an overview of emerging research trends as well as a comprehensive perspective on the current status of research on chalcogenides. Finally, we attempt to provide insights into how chalcogenides can continue to drive technological breakthroughs in both memory and sensing applications while shaping the future landscape of intelligent systems, smart sensing platforms, and sustainable technology development.
Comparison of Clinical and Radiographic Outcomes According to the Presence or Absence of a Posterior Draw Force during Graft Fixation in Anterior Cruciate Ligament Reconstruction
Background and Objectives: A reduction forced toward the posterior side during graft fixation may help to lessen anterior tibial translation after ACL reconstruction. The purpose was to compare the clinical and radiological outcomes of graft fixation when a posterior draw was used and when it was not used during anterior cruciate ligament (ACL) reconstruction surgery. Materials and Methods: Of 110 patients who had undergone primary arthroscopic ACL reconstruction between January 2017 and August 2020, in all, 76 patients had been operated on without a posterior draw (non-draw group), and 34 patients had received surgery with a posterior draw (draw group). The results of the Lachman test and the pivot-shift test, the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) indexes, the Lysholm scores, the International Knee Documentation Committee (IKDC) subjective scores, and side-to-side difference (STSD) on stress radiography were compared between the two groups. Results: The postoperative WOMAC indexes, Lysholm scores, and IKDC subjective scores were similar across both groups. Postoperative STSD (2.4 ± 2.2 for the non-draw group vs. 2.0 ± 2.2 for the draw group; p = 0.319) and change in STSD (3.5 ± 3.5 for preoperative STSD vs. 4.3 ± 4.4 for postoperative STSD; p = 0.295) were not superior in the draw group. Conclusions: The take-home message is that graft fixation with a posterior draw during ACL reconstruction did not result in significantly better postoperative stability. The postoperative clinical outcomes were similar between both groups.
Effect of Polydeoxyribonucleotide on Chondrocutaneous Composite Grafts Survival
BackgroundA composite graft is considered the best choice for facial reconstruction because of proper texture, color, and simple surgical techniques. However, due to revascularization by the bridging phenomenon, it has limitations with unpredictable survival rates and can be applied only to small defects. Polydeoxyribonucleotide (PDRN) plays an important role in multiple vascular processes such as angiogenesis via production of a vascular endothelial growth factor and by providing an anti-inflammatory effect by reducing pro-inflammatory cytokines through the adenosine A2 receptor stimulation. Thus, here, we investigated PDRN as a supportive method to improve survival of composite grafts.MethodsChondrocutaneous composite grafts were applied to both ears of 20 New Zealand White rabbits. The grafts were then rotated and returned to their positions to prevent the original blood flow from the base of the grafts. On postoperative days 1, 3, 6, 9, and 12, PDRN was injected intradermally into the experimental group (20 ears) and normal saline was injected into the control group (20 ears) to exclude bias of pressure effect. After 12 days, graft survival and cutaneous blood flow were examined under laser speckle contrast imaging.ResultsGross observation indicated that the graft viability in the PDRN group was significantly higher than that in the control group (p < 0.05). Through laser speckle contrast imaging, signal intensity increased from the periphery and progressed centrally with treatment.ConclusionOur findings suggest that PDRN may increase blood flow around at the base of the graft, restore the perfusion, and improve the survival of the composite grafts.No Level AssignedThis journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.
Microsecond triplet emission from organic chromophore-transition metal dichalcogenide hybrids via through-space spin orbit proximity effect
Efficient light generation from triplet states of organic molecules has been a hot yet demanding topic in academia and the display industry. Herein, we propose a strategy for developing triplet emitter by creating heterostructures of organic chromophores and transition metal dichalcogenides (TMDs). These heterostructures emit microsecond phosphorescence at room temperature, while their organic chromophores intrinsically exhibit millisecond phosphorescence under vibration dissipation-free conditions. This enhancement in phosphorescence is indicative of significantly enhanced spin-orbit coupling efficiency through coupling with TMDs. Through detailed studies on these hybrids from various perspectives, we elucidate key features of each component essential for generating microsecond triplet emission, including 2H-TMDs with heavy transition metals and aromatic carbonyl with an ortho-hydroxy group. Our intriguing findings open avenues for exploring the universal applicability of fast and stable hybrid triplet emitters. Metal-organic charge transfer has been the inevitable core of microsecond triplet emitters. Here the authors hybridize organic chromophores with transition-metal dichalcogenides to realize microsecond phosphorescence without metal-organic ligand bonding.
ZnO composite nanolayer with mobility edge quantization for multi-value logic transistors
A quantum confined transport based on a zinc oxide composite nanolayer that has conducting states with mobility edge quantization is proposed and was applied to develop multi-value logic transistors with stable intermediate states. A composite nanolayer with zinc oxide quantum dots embedded in amorphous zinc oxide domains generated quantized conducting states at the mobility edge, which we refer to as “mobility edge quantization”. The unique quantized conducting state effectively restricted the occupied number of carriers due to its low density of states, which enable current saturation. Multi-value logic transistors were realized by applying a hybrid superlattice consisting of zinc oxide composite nanolayers and organic barriers as channels in the transistor. The superlattice channels produced multiple states due to current saturation of the quantized conducting state in the composite nanolayers. Our multi-value transistors exhibited excellent performance characteristics, stable and reliable operation with no current fluctuation, and adjustable multi-level states. Designing multi-value logic transistors with stable and reliable intermediate states remains a challenge. Here, the authors report the mobility edge quantization phenomenon via resonant hybridization of ZnO QDs embedded in amorphous ZnO domains to enable adjustable multi-value intermediate states.
Deep learning–radiomics integrated noninvasive detection of epidermal growth factor receptor mutations in non-small cell lung cancer patients
This study focused on a novel strategy that combines deep learning and radiomics to predict epidermal growth factor receptor (EGFR) mutations in patients with non-small cell lung cancer (NSCLC) using computed tomography (CT). A total of 1280 patients with NSCLC who underwent contrast-enhanced CT scans and EGFR mutation testing before treatment were selected for the final study. Regions of interest were segmented from the CT images to extract radiomics features and obtain tumor images. These tumor images were input into a convolutional neural network model to extract 512 image features, which were combined with radiographic features and clinical data to predict the EGFR mutation. The generalization performance of the model was evaluated using external institutional data. The internal and external datasets contained 324 and 130 EGFR mutants, respectively. Sex, height, weight, smoking history, and clinical stage were significantly different between the EGFR-mutant patient groups. The EGFR mutations were predicted by combining the radiomics and clinical features, and an external validation dataset yielded an area under the curve (AUC) value of 0.7038. The model utilized 1280 tumor images, radiomics features, and clinical characteristics as input data and exhibited an AUC of approximately 0.81 and 0.78 during the primary cohort and external validation, respectively. These results indicate the feasibility of integrating radiomics analysis with deep learning for predicting EGFR mutations. CT-image-based genetic testing is a simple EGFR mutation prediction method, which can improve the prognosis of NSCLC patients and help establish personalized treatment strategies.
Synthesis of α,ω-Primary Hydroxyl-Terminated Polyether Polyols Using Prussian Blue Analogs as Catalysts
Polyalkylene oxides and polyether polyols are the most frequently used raw materials in polyurethane production, and are commonly produced via the ring-opening polymerization of epoxides, particularly propylene oxide. However, the resulting polyols predominantly contain predominantly secondary hydroxyl groups (up to 95%) that are less reactive than those capped with primary hydroxyl groups, thereby limiting the applications of the former in polyurethane synthesis. In this study, a viable procedure for producing α,ω-primary hydroxyl-terminated polyols using various Prussian blue analogs as heterogeneous catalysts was developed. The reaction kinetics were first investigated to gain insight into the reactivity of primary and secondary alcohols in the ring-opening of ε-caprolactone. Subsequently, ε-caprolactone-capped polyols with predominantly primary hydroxyl groups were successfully synthesized via the ring-opening reaction of ε-caprolactone using polypropylene glycol as the macroinitiator. The reactivities of the resultant ε-caprolactone-capped polyols for polyurethane synthesis were greatly enhanced compared to those of conventional polyols.