Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
5
result(s) for
"Hesse, Ronny"
Sort by:
Procedures for the GMP-Compliant Production and Quality Control of 18FPSMA-1007: A Next Generation Radiofluorinated Tracer for the Detection of Prostate Cancer
2017
Radiolabeled tracers targeting the prostate-specific membrane antigen (PSMA) have become important radiopharmaceuticals for the PET-imaging of prostate cancer. In this connection, we recently developed the fluorine-18-labelled PSMA-ligand [18F]PSMA-1007 as the next generation radiofluorinated Glu-ureido PSMA inhibitor after [18F]DCFPyL and [18F]DCFBC. Since radiosynthesis so far has been suffering from rather poor yields, novel procedures for the automated radiosyntheses of [18F]PSMA-1007 have been developed. We herein report on both the two-step and the novel one-step procedures, which have been performed on different commonly-used radiosynthesisers. Using the novel one-step procedure, the [18F]PSMA-1007 was produced in good radiochemical yields ranging from 25 to 80% and synthesis times of less than 55 min. Furthermore, upscaling to product activities up to 50 GBq per batch was successfully conducted. All batches passed quality control according to European Pharmacopoeia standards. Therefore, we were able to disclose a new, simple and, at the same time, high yielding production pathway for the next generation PSMA radioligand [18F]PSMA-1007. Actually, it turned out that the radiosynthesis is as easily realised as the well-known [18F]FDG synthesis and, thus, transferable to all currently-available radiosynthesisers. Using the new procedures, the clinical daily routine can be sustainably supported in-house even in larger hospitals by a single production batch.
Journal Article
Retained primary teeth in STAT3 hyper-IgE syndrome: early intervention in childhood is essential
2020
Background
STAT3 hyper-IgE syndrome (STAT3-HIES) is a rare primary immunodeficiency that clinically overlaps with atopic dermatitis. In addition to eczema, elevated serum-IgE, and recurrent infections, STAT3-HIES patients suffer from characteristic facies, midline defects, and retained primary teeth. To optimize dental management we assessed the development of dentition and the long-term outcomes of dental treatment in 13 molecularly defined STAT3-HIES patients using questionnaires, radiographs, and dental investigations.
Results
Primary tooth eruption was unremarkable in all STAT3-HIES patients evaluated. Primary tooth exfoliation and permanent tooth eruption was delayed in 83% of patients due to unresorbed tooth roots. A complex orthodontic treatment was needed for one patient receiving delayed extraction of primary molars and canines. Permanent teeth erupted spontaneously in all patients receiving primary teeth extraction of retained primary teeth during average physiologic exfoliation time.
Conclusions
The association of STAT3-HIES with retained primary teeth is important knowledge for dentists and physicians as timely extraction of retained primary teeth prevents dental complications. To enable spontaneous eruption of permanent teeth in children with STAT3-HIES, we recommend extracting retained primary incisors when the patient is not older than 9 years of age and retained primary canines and molars when the patient is not older than 13 years of age, after having confirmed the presence of the permanent successor teeth by radiograph.
Journal Article
Procedures for the GMP-Compliant Production and Quality Control of 18FPSMA-1007: A Next Generation Radiofluorinated Tracer for the Detection of Prostate Cancer
2017
Radiolabeled tracers targeting the prostate-specific membrane antigen (PSMA) have become important radiopharmaceuticals for the PET-imaging of prostate cancer. In this connection, we recently developed the fluorine-18-labelled PSMA-ligand [18F]PSMA-1007 as the next generation radiofluorinated Glu-ureido PSMA inhibitor after [18F]DCFPyL and [18F]DCFBC. Since radiosynthesis so far has been suffering from rather poor yields, novel procedures for the automated radiosyntheses of [18F]PSMA-1007 have been developed. We herein report on both the two-step and the novel one-step procedures, which have been performed on different commonly-used radiosynthesisers. Using the novel one-step procedure, the [18F]PSMA-1007 was produced in good radiochemical yields ranging from 25 to 80% and synthesis times of less than 55 min. Furthermore, upscaling to product activities up to 50 GBq per batch was successfully conducted. All batches passed quality control according to European Pharmacopoeia standards. Therefore, we were able to disclose a new, simple and, at the same time, high yielding production pathway for the next generation PSMA radioligand [18F]PSMA-1007. Actually, it turned out that the radiosynthesis is as easily realised as the well-known [18F]FDG synthesis and, thus, transferable to all currently-available radiosynthesisers. Using the new procedures, the clinical daily routine can be sustainably supported in-house even in larger hospitals by a single production batch.Radiolabeled tracers targeting the prostate-specific membrane antigen (PSMA) have become important radiopharmaceuticals for the PET-imaging of prostate cancer. In this connection, we recently developed the fluorine-18-labelled PSMA-ligand [18F]PSMA-1007 as the next generation radiofluorinated Glu-ureido PSMA inhibitor after [18F]DCFPyL and [18F]DCFBC. Since radiosynthesis so far has been suffering from rather poor yields, novel procedures for the automated radiosyntheses of [18F]PSMA-1007 have been developed. We herein report on both the two-step and the novel one-step procedures, which have been performed on different commonly-used radiosynthesisers. Using the novel one-step procedure, the [18F]PSMA-1007 was produced in good radiochemical yields ranging from 25 to 80% and synthesis times of less than 55 min. Furthermore, upscaling to product activities up to 50 GBq per batch was successfully conducted. All batches passed quality control according to European Pharmacopoeia standards. Therefore, we were able to disclose a new, simple and, at the same time, high yielding production pathway for the next generation PSMA radioligand [18F]PSMA-1007. Actually, it turned out that the radiosynthesis is as easily realised as the well-known [18F]FDG synthesis and, thus, transferable to all currently-available radiosynthesisers. Using the new procedures, the clinical daily routine can be sustainably supported in-house even in larger hospitals by a single production batch.
Journal Article
EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision
by
Slart, Riemer H. J. A.
,
Buechel, Ronny R.
,
Acampa, Wanda
in
Adult
,
Angiography
,
Bioengineering
2015
Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 2015 procedural guidelines are highlighted, focusing on the important changes related to new instrumentation with improved image information and the possibility to reduce radiation exposure, which is further discussed in relation to the recent developments of new International Commission on Radiological Protection (ICRP) models. Introduction of the selective coronary vasodilator regadenoson and the use of coronary CT-contrast agents for hybrid imaging with SPECT/CT angiography are other important areas for nuclear cardiology that were not included in the previous guidelines. A large number of minor changes have been described in more detail in the fully revised version available at the EANM home page:
https://eanm.org/wp-content/uploads/2025/04/2015_myocardial_perfusion.pdf
.
Journal Article
Die Erreichbarkeit deutscher Großstädte durch den Schienenpersonenverkehr
by
Püschel, Ronny
,
Evangelinos, Christos
,
Hesse, Claudia
in
International comparisons
,
Multivariate analysis
,
Railway networks
2011
In this paper, the accessibility of major German cities for rail passenger transport is empirically examined. Using multivariate procedures, 3 partial indicators will be combined into a synthesized index. This procedure is applied for the assessment of German transport infrastructure for the first time. It was found that the accessibility of rail-bound cities in eastern Germany are clearly inferior to the old federal states. [PUB ABSTRACT]
Journal Article