Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
235 result(s) for "Horn, Michael P"
Sort by:
PR3-ANCA and panel diagnostics in pediatric inflammatory bowel disease to distinguish ulcerative colitis from Crohn's disease
Accurate classification of patients with inflammatory bowel disease into the subtypes ulcerative colitis (UC) and Crohn's disease (CD) is still a challenge, but important for therapy and prognosis. To evaluate the diagnostic utility of anti-neutrophil cytoplasmic antibodies specific for proteinase-3 (PR3-ANCA) for ulcerative colitis (UC) and the value of an antibody panel incorporating PR3-ANCA to differentiate between Crohn's disease (CD) and UC. In this cohort study, 122 pediatric and adolescent individuals were retrospectively included (61 IBD patients of two clinical centers, 61 non-IBD controls). All subjects had a comprehensive antibody profile done from stored sera taken close to time of diagnosis. By employing quasi-exhaustive logistic regression the best discriminative model for UC and CD,subjects was determined in a training cohort and confirmed in a validation cohort. PR3-ANCA was specifically associated with UC (odds ratio (OR), 17.6; 95% confidence interval (CI); 3.6, 87); P < .001). A four antibody-panel including PR3-ANCA had an AUC of 90.81% (95%CI; 81.93, 99.69) to distinguish between UC and CD in the training cohort. In a smaller external validation cohort, the AUC was 84.13% (95%CI; 64.21, 100) for accurate diagnosis of CD and UC. PR3-ANCA is highly specific for UC. The differentiating capability of a panel, which contains PR3-ANCA and weighs broadly available antibodies, is superior and utilization of the panel can support accurate classification in the work-up of pediatric and adolescent patients with IBD patients.
Humoral response to mRNA vaccines against SARS-CoV-2 in patients with humoral immunodeficiency disease
Although mRNA-based vaccines against SARS-CoV-2 induce a robust immune response and prevent infections and hospitalizations, there are limited data on the antibody response in individuals with humoral immunodeficiency. The aim of this study was to evaluate the humoral immune response after two vaccine doses with BNT162b2 or mRNA-1273 in patients with humoral immunodeficiency disease. This cross-sectional study assessed 39 individuals with hypogammaglobulinemia under immunoglobulin replacement therapy. IgG anti-SARS-CoV-2 spike protein antibodies (anti-S) were measured 4 weeks to 4 months after two doses of an mRNA vaccine against SARS-CoV-2. The proportion of patients, who developed a humoral immune response to the spike protein were evaluated and compared to 19 healthy controls. After vaccination with two vaccine doses, 26/39 patients (66.7%) with humoral immunodeficiency disease and all healthy controls developed anti-S. In subjects with baseline IgG <3 g/l, only 1/5 (20%) showed a humoral immune response. 10 out of 26 with CVID (38.5%) and 7/9 under immunosuppressive drugs (77.8%) developed no immune response (13 subjects with no response) compared to 0/19 in healthy controls. Subgroup analysis in patients without immunosuppressive drugs revealed lower anti-S in patients with moderate to severe humoral immunodeficiency disease: baseline IgG <3 g/l: 12.0 AU/ml (95%CI 12.0-125.0), baseline IgG 3-5 g/l: 99.9 AU/ml (95%CI 14.4-400.0), baseline IgG >5 g/l: 151.5 AU/ml (95%CI 109.0-400.0), healthy controls 250.0 AU/ml (95%CI 209.0-358.0), p = 0.007. In most patients with mild to moderate humoral immunodeficiency we found only slightly lower anti-S antibodies compared with healthy controls after two vaccine doses with BNT162b2 and mRNA-1273. However, in patients with a decreased baseline IgG below 3 g/l and/or under immunosuppressive drugs, we found severely impaired humoral immune responses.
Rapid immunoassays for diagnosis of heparin-induced thrombocytopenia: Comparison of diagnostic accuracy, reproducibility, and costs in clinical practice
Immunoassays are crucial in the work-up of patients with suspected heparin-induced thrombocytopenia (HIT) and rapid tests have been recently developed. However, comparative data on diagnostic accuracy, reproducibility, and analytical costs of different immunoassays in clinical practice are limited. Samples of 179 consecutive patients evaluated for suspected HIT in clinical practice using a polyspecific enzyme-linked immunoabsorbent assay (GTI diagnostics; ELISA) and a rapid particle gel immunoassay (PaGIA), were additionally analysed with a IgG-specific chemiluminescent immunoassay (AcuStar HIT-IgG). Presence of HIT was defined as a positive functional heparin-induced platelet aggregation test. Diagnostic accuracy was determined for low, intermediate and high thresholds as previously established (ELISA: optical density 0.4, 1.3, and 2.0 respectively; PaGIA: positive/negative, titre of 4, titre of 32; AcuStar HIT-IgG: 1.0 U/ml, 2.8, 9.4) and reproducibility was assessed by repeated measurements. Costs of test determination were calculated taking reagents, controls, and working time of technicians according to Swiss health care system into account. Data on PaGIA results were available for 171 patients (95.5%), ELISA for 144 patients (80.4%), and AcuStar HIT-IgG for 179 patients (100%). Sensitivity was above 95% for all assays at low and intermediate thresholds. Specificity increased with higher thresholds and was above 90% for all assays with intermediate and high thresholds. Specificity of AcuStar HIT-IgG (92.8%; 95% CI 87.7, 96.2) was significantly higher than PaGIA (83.0%; 95% CI 76.3, 88.5) and higher than ELISA (81.8%, 95% CI 74.2, 88.0) at low threshold (p<0.05). Reproducibility was adequate for all assays. Total costs per test were CHF 51.02 for ELISA, 117.70 for AcuStar HIT-IgG, and 83.13 for PaGIA. We observed favourable diagnostic accuracy measures and a high reproducibility for PaGIA and AcuStar HIT-IgG. Implementation into 24-hours-service might improve patient care but the results must be confirmed in other settings and larger populations as well.
Humoral and cellular immune responses on SARS-CoV-2 vaccines in patients with anti-CD20 therapies: a systematic review and meta-analysis of 1342 patients
BackgroundImmune responses on SARS-CoV-2 vaccination in patients receiving anti-CD20 therapies are impaired but vary considerably. We conducted a systematic review and meta-analysis of the literature on SARS-CoV-2 vaccine induced humoral and cell-mediated immune response in patients previously treated with anti-CD20 antibodies.MethodsWe searched PubMed, Embase, Medrxiv and SSRN using variations of search terms ‘anti-CD20’, ‘vaccine’ and ‘COVID’ and included original studies up to 21 August 2021. We excluded studies with missing data on humoral or cell-mediated immune response, unspecified methodology of response testing, unspecified timeframes between vaccination and blood sampling or low number of participants (≤3). We excluded individual patients with prior COVID-19 or incomplete vaccine courses. Primary endpoints were humoral and cell-mediated immune response rates. Subgroup analyses included time since anti-CD20 therapy, B cell depletion and indication for anti-CD20 therapy. We used random-effects models of proportions.FindingsNinety studies were assessed. Inclusion criteria were met by 23 studies comprising 1342 patients. Overall rate of humoral response was 0.40 (95% CI 0.35 to 0.47). Overall rate of cell-mediated immune responses was 0.71 (95% CI 0.57 to 0.87). A time interval >6 months since last anti-CD20 therapy was associated with higher humoral response rates with 0.63 (95% CI 0.53 to 0.72) versus <6 months 0.2 (95% CI 0.03 to 0.43); p=0<01. Similarly, patients with circulating B cells more frequently showed humoral responses. Anti-CD20-treated kidney transplant recipients showed lower humoral response rates than patients with haematological malignancies or autoimmune disease.InterpretationPatients on anti-CD20 therapies can develop humoral and cell-mediated immune responses after SARS-CoV-2 vaccination, but subgroups such as kidney transplant recipients or those with very recent therapy and depleted B cell are at high risk for non-seroconversion and should be individually assessed for personalised SARS-CoV-2 vaccination strategies. Potential limitations are small patient numbers and heterogeneity of studies included.FundingThis study was funded by Bern University Hospital.
Machine Learning in Antibody Diagnostics for Inflammatory Bowel Disease Subtype Classification
Antibody testing in inflammatory bowel disease (IBD) can add to diagnostic accuracy of the main subtypes Crohn’s disease (CD) and ulcerative colitis (UC). Whether modern modeling techniques such as supervised and unsupervised machine learning are of value for finer distinction of subtypes such as IBD-unclassified (IBD-U) is not known. We determined the antibody profile of 100 adult IBD patients from the Swiss IBD cohort study with known subtype (50 CD, 50 UC) as well as of 76 IBD-U patients. We included ASCA IgG and IgA, p-ANCA, MPO- and PR3-ANCA, and xANCA measurements for computing different antibody panels as well as machine learning models. The AUC of an optimized antibody panel was 85% (95%CI, 78–92%) to distinguish CD from UC patients. The antibody profile of IBD-U patients was closely related to UC. No specific antibody profile was predictive for IBD-U nor for re-classification. The panel diagnostic was in favor of UC reclassification prediction with a correct assignment rate of 69.2–73.1% depending on the cut-off applied. Supervised machine learning could not distinguish between CD, UC, and IBD-U. More so, unsupervised machine learning suggested only two distinct clusters as a likely number of IBD subtypes. Antibodies in IBD are supportive in confirming clinical determined subtypes CD and UC but have limited capacity to predict IBD-U and reclassification during follow-up. In terms of antibody profiles, IBD-U is not a distinct subtype of IBD.
Clinical Validity of Anti-Proteinase 3 Antibodies in Patients with Inflammatory Bowel Disease: A Short Meta-Analysis
Anti-neutrophil cytoplasmic antibodies (ANCA) directed to proteinase 3 (PR3) represent highly established markers for patients with ANCA-associated vasculitis (AAV). PR3-ANCA have also demonstrated utility in the management of inflammatory bowel disease (IBD). More specifically, PR3-ANCA discriminate individuals with ulcerative colitis (UC) from Crohn’s disease (CD) patients and are associated with disease severity, activity, and treatment non-response. Here, we aim to summarize the current data on the diagnostic utility of PR3-ANCA in IBD. A structured, systematic literature review, including three electronic databases, was conducted on June 6th, 2023, to identify studies assessing the diagnostic accuracy of the QUANTA Flash® PR3 assay in UC vs. CD patients. Electronic searches were supplemented by hand searching. A hierarchical, bivariate, mixed-effect meta-analysis was conducted using the metandi function, as per the Cochrane collaboration recommendations. Study quality was assessed using the QUADAS-2 tool, which considers the risk of bias and applicability. Six out of a hundred and eleven citations met the inclusion criteria and reported QUANTA Flash® PR3 diagnostic accuracy in UC vs. CD (UC, n = 667, CD, n = 682 patients). The sensitivity/specificity point estimate for UC was 34.9%/95.9%. This resulted in a Diagnostic Odds Ratio (DOR) of 12.6. The risk of bias was low in the index test and reference standard domains. Four of the six studies (67%) showed an unclear risk of bias in patient selection and in flow and timing domains. All studies had low concerns about applicability in all the domains. PR3-ANCA measured with the QUANTA Flash® PR3 assay represent novel diagnostic markers in IBD and enables discrimination between UC and CD.
Serum calprotectin as new biomarker for disease severity in idiopathic pulmonary fibrosis: a cross-sectional study in two independent cohorts
BackgroundNon-invasive biomarkers for the assessment of disease severity in idiopathic pulmonary fibrosis (IPF) are urgently needed. Calprotectin belongs to the S-100 proteins produced by neutrophils, which likely contribute to IPF pathogenesis. Calprotectin is a well-established biomarker in inflammatory bowel diseases. In this cross-sectional study, we aimed to establish the potential role of calprotectin as a biomarker in IPF. Specifically, we hypothesised that patients with IPF have higher serum calprotectin levels compared with healthy controls, and that calprotectin levels are associated with disease severity.MethodsBlood samples were obtained from healthy volunteers (n=26) and from two independent IPF cohorts (derivation cohort n=26, validation cohort n=66). Serum calprotectin levels were measured with a commercial kit adapted for that purpose and compared between healthy controls and patients with IPF. Clinical parameters, including forced vital capacity, diffusing capacity for carbon monoxide (DLCO) and the Composite Physiologic Index (CPI), were correlated with calprotectin serum levels.ResultsThe IPF derivation cohort showed increased serum calprotectin levels compared with healthy controls (2.47±1.67 vs 0.97±0.53 µg/mL, p<0.001). In addition, serum calprotectin levels correlated with DLCO% predicted (r=−0.53, p=0.007) and with CPI (r=0.66, p=0.007). These findings were confirmed in an independent IPF validation cohort.ConclusionSerum calprotectin levels are significantly increased in patients with IPF compared with healthy controls and correlate with DLCO and CPI. Calprotectin might be a potential new biomarker for disease severity in IPF.
The Release Kinetics of Eosinophil Peroxidase and Mitochondrial DNA Is Different in Association with Eosinophil Extracellular Trap Formation
Eosinophils are a subset of granulocytes characterized by a high abundance of specific granules in their cytoplasm. To act as effector cells, eosinophils degranulate and form eosinophil extracellular traps (EETs), which contain double-stranded DNA (dsDNA) co-localized with granule proteins. The exact molecular mechanism of EET formation remains unknown. Although the term “EET release” has been used in scientific reports, it is unclear whether EETs are pre-formed in eosinophils and subsequently released. Moreover, although eosinophil degranulation has been extensively studied, a precise time-course of granule protein release has not been reported until now. In this study, we investigated the time-dependent release of eosinophil peroxidase (EPX) and mitochondrial DNA (mtDNA) following activation of both human and mouse eosinophils. Unexpectedly, maximal degranulation was already observed within 1 min with no further change upon complement factor 5 (C5a) stimulation of interleukin-5 (IL-5) or granulocyte/macrophage colony-stimulating factor (GM-CSF)-primed eosinophils. In contrast, bulk mtDNA release in the same eosinophil populations occurred much slower and reached maximal levels between 30 and 60 min. Although no single-cell analyses have been performed, these data suggest that the molecular pathways leading to degranulation and mtDNA release are at least partially different. Moreover, based on these data, it is likely that the association between the mtDNA scaffold and granule proteins in the process of EET formation occurs in the extracellular space.
Trajectories of humoral and cellular immunity and responses to a third dose of mRNA vaccines against SARS-CoV-2 in patients with a history of anti-CD20 therapy
BackgroundThe majority of patients with B-cell-depleting therapies show compromised vaccination-induced immune responses. Herein, we report on the trajectories of anti-SARS-CoV-2 immune responses in patients of the RituxiVac study compared with healthy volunteers and investigate the immunogenicity of a third vaccination in previously humoral non-responding patients.MethodsWe investigated the humoral and cell-mediated immune response after SARS-CoV-2 messanger RNA vaccination in patients with a history with anti-CD20 therapies. Coprimary outcomes were antispike and SARS-CoV-2-stimulated interferon-γ concentrations in vaccine responders 4.3 months (median; IQR: 3.6–4.8 months) after first evaluation, and humoral and cell-mediated immunity (CMI) after a third vaccine dose in previous humoral non-responders. Immunity decay rates were compared using analysis of covariance in linear regression.Results5.6 months (IQR: 5.1–6.7) after the second vaccination, we detected antispike IgG in 88% (29/33) and CMI in 44% (14/32) of patients with a humoral response after two-dose vaccination compared with 92% (24/26) healthy volunteers with antispike IgG and 69% (11/16) with CMI 6.8 months after the second vaccination (IQR: 6.0–7.1). Decay rates of antibody concentrations were comparable between patients and controls (p=0.70). In two-dose non-responders, a third SARS-CoV-2 vaccine elicited humoral responses in 19% (6/32) and CMI in 32% (10/31) participants.ConclusionThis study reveals comparable immunity decay rates between patients with anti-CD20 treatments and healthy volunteers, but inefficient humoral or CMI after a third SARS-CoV-2 vaccine in most two-dose humoral non-responders calling for individually tailored vaccination strategies in this population.Trial registration numberNCT04877496; ClinicalTrials.gov number.
Designed Ankyrin Repeat Proteins: A New Approach to Mimic Complex Antigens for Diagnostic Purposes?
Inhibitory antibodies directed against coagulation factor VIII (FVIII) can be found in patients with acquired and congenital hemophilia A. Such FVIII-inhibiting antibodies are routinely detected by the functional Bethesda Assay. However, this assay has a low sensitivity and shows a high inter-laboratory variability. Another method to detect antibodies recognizing FVIII is ELISA, but this test does not allow the distinction between inhibitory and non-inhibitory antibodies. Therefore, we aimed at replacing the intricate antigen FVIII by Designed Ankyrin Repeat Proteins (DARPins) mimicking the epitopes of FVIII inhibitors. As a model we used the well-described inhibitory human monoclonal anti-FVIII antibody, Bo2C11, for the selection on DARPin libraries. Two DARPins were selected binding to the antigen-binding site of Bo2C11, which mimic thus a functional epitope on FVIII. These DARPins inhibited the binding of the antibody to its antigen and restored FVIII activity as determined in the Bethesda assay. Furthermore, the specific DARPins were able to recognize the target antibody in human plasma and could therefore be used to test for the presence of Bo2C11-like antibodies in a large set of hemophilia A patients. These data suggest, that our approach might be used to isolate epitopes from different sets of anti-FVIII antibodies in order to develop an ELISA-based screening assay allowing the distinction of inhibitory and non-inhibitory anti-FVIII antibodies according to their antibody signatures.