Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
29 result(s) for "Huisman, Johan Alexander"
Sort by:
Recent Developments in Wireless Soil Moisture Sensing to Support Scientific Research and Agricultural Management
In recent years, wireless sensor network (WSN) technology has emerged as an important technique for wireless sensing of soil moisture from the field to the catchment scale. This review paper presents the current status of wireless sensor network (WSN) technology for distributed, near real-time sensing of soil moisture to investigate seasonal and event dynamics of soil moisture patterns. It is also discussed how WSN measurements of soil measurements contribute to the validation and downscaling of satellite data and non-invasive geophysical instruments as well as the validation of distributed hydrological models. Finally, future perspectives for WSN measurements of soil moisture are highlighted, which includes the improved integration of real-time WSN measurements with other information sources using the latest wireless communication techniques and cyberinfrastructures.
Effective Calibration of Low-Cost Soil Water Content Sensors
Soil water content is a key variable for understanding and modelling ecohydrological processes. Low-cost electromagnetic sensors are increasingly being used to characterize the spatio-temporal dynamics of soil water content, despite the reduced accuracy of such sensors as compared to reference electromagnetic soil water content sensing methods such as time domain reflectometry. Here, we present an effective calibration method to improve the measurement accuracy of low-cost soil water content sensors taking the recently developed SMT100 sensor (Truebner GmbH, Neustadt, Germany) as an example. We calibrated the sensor output of more than 700 SMT100 sensors to permittivity using a standard procedure based on five reference media with a known apparent dielectric permittivity (1 < Ka < 34.8). Our results showed that a sensor-specific calibration improved the accuracy of the calibration compared to single “universal” calibration. The associated additional effort in calibrating each sensor individually is relaxed by a dedicated calibration setup that enables the calibration of large numbers of sensors in limited time while minimizing errors in the calibration process.
Comparing the Accuracy of Soil Moisture Estimates Derived from Bulk and Energy-Resolved Gamma Radiation Measurements
Monitoring soil moisture (SM) using permanently installed gamma radiation (GR) detectors is a promising non-invasive method based on the inverse relationship between SM and soil-emitted GR. In a previous study, we successfully estimated SM from environmental gamma radiation (EGR) measured by a low-cost counter-tube detector. Since this detector type provides a bulk GR response across a wide energy range, EGR signals are influenced by several confounding factors, e.g., soil radon emanation, biomass. To what extent these confounding factors deteriorate the accuracy of SM estimates obtained from EGR is not fully understood. Therefore, the aim of this study was to compare the accuracy of SM estimates from EGR with those from reference 40K GR (1460 keV) measurements which are much less influenced by these factors. For this, a Geiger–Mueller counter (G–M), which is commonly used for EGR monitoring, and a gamma spectrometer were installed side by side in an agricultural field equipped with in situ sensors to measure reference SM and a meteorological station. The EGRG–M and spectrometry-based 40K measurements were related to reference SM using a functional relationship derived from theory. We found that daily SM can be predicted with an RMSE of 3.39 vol. % from 40K using the theoretical value of α = 1.11 obtained from the effective ratio of GR mass attenuation coefficients for the water and solid phase. A lower accuracy was achieved for the EGRG–M measurements (RMSE = 6.90 vol. %). Wavelet coherence analysis revealed that the EGRG–M measurements were influenced by radon-induced noise in winter. Additionally, biomass shielding had a stronger impact on EGRG–M than on 40K GR estimates of SM during summer. In summary, our study provides a better understanding on the lower prediction accuracy of EGRG–M and suggests that correcting for biomass can improve SM estimation from the bulk EGR data of operational radioactivity monitoring networks.
Characterization of Preferential Flow Occurrence During Freeze‐Thaw Cycles
Preferential flow (PF) critically influences water and energy dynamics in frozen soils, yet its quantification and mechanisms remain poorly understood due to observational challenges. This study proposes a novel method to identify PF by analyzing soil temperature response times across depths. The method detects thermal anomalies—such as earlier or synchronized temperature peaks across depths—indicate rapid, advective heat transfer driven by PF and phase‐change latent heat. We conducted our investigation in the Qilian Mountain areas using a network of soil temperature stations. Our findings reveal that PF significantly enhances magnitude and speed of energy transfer to deeper soil. Furthermore, the frequency of PF varies significantly across the partially frozen, frozen and partially thawing phases, as well as across different sites and depths, driven by shifts soil properties and meteorological forcing. Using random forest analysis, we identified key spatial drivers related to soil pore structure: soil organic carbon (partially frozen phase), residual soil moisture (frozen phase), and wilting point (partially thawed phase). Furthermore, classification and regression tree analysis revealed that the snowmelt rates and maximum near‐surface (5 cm) soil temperatures are the primary temporal drivers of PF. Our study demonstrates that PF can be effectively identified by analyzing soil temperatures at various depths. By utilizing temperature‐based detection during the frozen phase and moisture monitoring in the unfrozen phase, we can better correlate PF with soil hydrothermal conditions, ultimately elucidating the complex mechanisms governing water and energy dynamics during the freeze‐thaw cycle.
Evaluation of Three Soil Moisture Profile Sensors Using Laboratory and Field Experiments
Soil moisture profile sensors (SMPSs) have a high potential for climate-smart agriculture due to their easy handling and ability to perform simultaneous measurements at different depths. To date, an accurate and easy-to-use method for the evaluation of long SMPSs is not available. In this study, we developed laboratory and field experiments to evaluate three different SMPSs (SoilVUE10, Drill&Drop, and SMT500) in terms of measurement accuracy, sensor-to-sensor variability, and temperature stability. The laboratory experiment features a temperature-controlled lysimeter to evaluate intra-sensor variability and temperature stability of SMPSs. The field experiment features a water level-controlled sandbox and reference TDR measurements to evaluate the soil water measurement accuracy of the SMPS. In both experiments, a well-characterized fine sand was used as measurement medium to ensure homogeneous dielectric properties in the measurement domain of the sensors. The laboratory experiments with the lysimeter showed that the Drill&Drop sensor has the highest temperature sensitivity with a decrease of 0.014 m3 m−3 per 10 °C, but at the same time showed the lowest intra- and inter-sensor variability. The field experiment with the sandbox showed that all three SMPSs have a similar performance (average RMSE ≈ 0.023 m3 m−3) with higher uncertainties at intermediate soil moisture contents. The presented combination of laboratory and field tests were found to be well suited to evaluate the performance of SMPSs and will be used to test additional SMPSs in the future.
On the Accuracy of Factory-Calibrated Low-Cost Soil Water Content Sensors
Soil water content (SWC) monitoring is often used to optimize agricultural irrigation. Commonly, capacitance sensors are used for this task. However, the factory calibrations have been often criticized for their limited accuracy. The aim of this paper is to test the degree of improvement of various sensor- and soil-specific calibration options compared to factory calibrations by taking the 10HS sensor as an example. To this end, a two-step sensor calibration was carried out. In the first step, the sensor response was related to dielectric permittivity using calibration in media with well-defined permittivity. The second step involved the establishment of a site-specific relationship between permittivity and soil water content using undisturbed soil samples and time domain reflectometry (TDR) measurements. Our results showed that a model, which considered the mean porosity and a fitted dielectric permittivity of the solid phase for each soil and depth, provided the best fit between bulk permittivity and SWC. Most importantly, it was found that the two-step calibration approach (RMSE: 1.03 vol.%) provided more accurate SWC estimates compared to the factory calibration (RMSE: 5.33 vol.%). Finally, we used these calibrations on data from drip-irrigated almond and apple orchards and compared the factory calibration with our two-step calibration approach.
Three‐Dimensional Characterization of Lateral Subsurface Flow in an Alpine Forested Hillslope on the Tibetan Plateau Using Time‐Lapse Electrical Resistivity Tomography
Lateral subsurface flow (LSF) is a key component of rainfall‐runoff generation on alpine forested slopes, but the influence of weathered bedrock on LSF remains poorly understood due to methodological constraints in monitoring three‐dimensional flow dynamics. This study addresses this gap by proposing a standardized morphological interpretation framework for time‐lapse 3D electrical resistivity tomography (3D‐ERT) inspired by dye‐tracing studies, and applying this framework to investigate LSF mechanisms in soil‐weathered bedrock systems on an alpine forested slope (NE Tibetan Plateau). During a controlled infiltration experiment, we conducted seven 3D‐ERT measurements. The inverted resistivity distributions were temperature‐corrected and converted to moisture content. The developed framework was then applied to quantify LSF patterns observed with ERT. Results show that the weathered bedrock layer acts as a permeable conduit, promoting downward leakage of water and limiting storage at the soil‐bedrock interface. LSF penetrated vertically into deeper weathered bedrock but remained laterally constrained within the monitoring range, with greater flow distances observed in deeper layers. The soil and weathered‐bedrock horizons exhibited contrasting moisture retention and drainage behavior during the initiation and development of LSF events. The emergence of two discrete flow pathways and the different maximum flow distance indicates the heterogeneity of LSF in weathered bedrock layers. Collectively, findings underscore the hydrological role of weathered bedrock in runoff generation on alpine slopes. The proposed ERT interpretation framework complements existing hydrogeophysical approaches by providing standardized morphological descriptors of ERT‐inferred wetting patterns, offering a transferable way to characterize the spatiotemporal organization of subsurface flow in data‐scarce mountain regions.
Low-Pass Filters for a Temperature Drift Correction Method for Electromagnetic Induction Systems
Electromagnetic induction (EMI) systems are used for mapping the soil’s electrical conductivity in near-surface applications. EMI measurements are commonly affected by time-varying external environmental factors, with temperature fluctuations being a big contributing factor. This makes it challenging to obtain stable and reliable data from EMI measurements. To mitigate these temperature drift effects, it is customary to perform a temperature drift calibration of the instrument in a temperature-controlled environment. This involves recording the apparent electrical conductivity (ECa) values at specific temperatures to obtain a look-up table that can subsequently be used for static ECa drift correction. However, static drift correction does not account for the delayed thermal variations of the system components, which affects the accuracy of drift correction. Here, a drift correction approach is presented that accounts for delayed thermal variations of EMI system components using two low-pass filters (LPF). Scenarios with uniform and non-uniform temperature distributions in the measurement device are both considered. The approach is developed using a total of 15 measurements with a custom-made EMI device in a wide range of temperature conditions ranging from 10 °C to 50 °C. The EMI device is equipped with eight temperature sensors spread across the device that simultaneously measure the internal ambient temperature during measurements. To parameterize the proposed correction approach, a global optimization algorithm called Shuffled Complex Evolution (SCE-UA) was used for efficient estimation of the calibration parameters. Using the presented drift model to perform corrections for each individual measurement resulted in a root mean square error (RMSE) of <1 mSm−1 for all 15 measurements. This shows that the drift model can properly describe the drift of the measurement device. Performing a drift correction simultaneously for all datasets resulted in a RMSE <1.2 mSm−1, which is considerably lower than the RMSE values of up to 4.5 mSm−1 obtained when using only a single LPF to perform drift corrections. This shows that the presented drift correction method based on two LPFs is more appropriate and effective for mitigating temperature drift effects.
Comparing Different Coupling and Modeling Strategies in Hydromechanical Models for Slope Stability Assessment
The dynamic interaction between subsurface flow and soil mechanics is often simplified in the stability assessment of variably saturated landslide-prone hillslopes. The aim of this study is to analyze the impact of conventional simplifications in coupling and modeling strategies on stability assessment of such hillslopes in response to precipitation using the local factor of safety (LFS) concept. More specifically, it investigates (1) the impact of neglecting poroelasticity, (2) transitioning from full coupling between hydrological and mechanical models to sequential coupling, and (3) reducing the two-phase flow system to a one-phase flow system (Richards’ equation). Two rainfall scenarios, with the same total amount of rainfall but two different relatively high (4 mm h−1) and low (1 mm h−1) intensities are considered. The simulation results of the simplified approaches are compared to a comprehensive, fully coupled poroelastic hydromechanical model with a two-phase flow system. It was found that the most significant difference from the comprehensive model occurs in areas experiencing the most transient changes due to rainfall infiltration in all three simplified models. Among these simplifications, the transformation of the two-phase flow system to a one-phase flow system showed the most pronounced impact on the simulated local factor of safety (LFS), with a maximum increase of +21.5% observed at the end of the high-intensity rainfall event. Conversely, using a rigid soil without poroelasticity or employing a sequential coupling approach with no iteration between hydromechanical parameters has a relatively minor effect on the simulated LFS, resulting in maximum increases of +2.0% and +1.9%, respectively. In summary, all three simplified models yield LFS results that are reasonably consistent with the comprehensive poroelastic fully coupled model with two-phase flow, but simulations are more computationally efficient when utilizing a rigid porous media and one-phase flow based on Richards’ equation.
Model-Based Correction of Temperature-Dependent Measurement Errors in Frequency Domain Electromagnetic Induction (FDEMI) Systems
Data measured using electromagnetic induction (EMI) systems are known to be susceptible to measurement influences associated with time-varying external ambient factors. Temperature variation is one of the most prominent factors causing drift in EMI data, leading to non-reproducible measurement results. Typical approaches to mitigate drift effects in EMI instruments rely on a temperature drift calibration, where the instrument is heated up to specific temperatures in a controlled environment and the observed drift is determined to derive a static thermal apparent electrical conductivity (ECa) drift correction. In this study, a novel correction method is presented that models the dynamic characteristics of drift using a low-pass filter (LPF) and uses it for correction. The method is developed and tested using a customized EMI device with an intercoil spacing of 1.2 m, optimized for low drift and equipped with ten temperature sensors that simultaneously measure the internal ambient temperature across the device. The device is used to perform outdoor calibration measurements over a period of 16 days for a wide range of temperatures. The measured temperature-dependent ECa drift of the system without corrections is approximately 2.27 mSm−1K−1, with a standard deviation (std) of only 30 μSm−1K−1 for a temperature variation of around 30 K. The use of the novel correction method reduces the overall root mean square error (RMSE) for all datasets from 15.7 mSm−1 to a value of only 0.48 mSm−1. In comparison, a method using a purely static characterization of drift could only reduce the error to an RMSE of 1.97 mSm−1. The results show that modeling the dynamic thermal characteristics of the drift helps to improve the accuracy by a factor of four compared to a purely static characterization. It is concluded that the modeling of the dynamic thermal characteristics of EMI systems is relevant for improved drift correction.