Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
17 result(s) for "Hyakutake, Toru"
Sort by:
Effect of non-Newtonian fluid properties on bovine sperm motility
The swimming process by which mammal spermatozoa progress towards an egg within the reproductive organs is important in achieving successful internal fertilization. The viscosity of oviductal mucus is more than two orders of magnitude greater than that of water, and oviductal mucus also has non-Newtonian properties. In this study, we experimentally observed sperm motion in fluids with various fluid rheological properties and investigated the influence of varying the viscosity and whether the fluid was Newtonian or non-Newtonian on the sperm motility. We selected polyvinylpyrrolidone and methylcellulose as solutes to create solutions with different rheological properties. We used the semen of Japanese cattle and investigated the following parameters: the sperm velocity, the straight-line velocity and the amplitude from the trajectory, and the beat frequency from the fragellar movement. In a Newtonian fluid environment, as the viscosity increased, the motility of the sperm decreased. However, in a non-Newtonian fluid, the straight-line velocity and beat frequency were significantly higher than in a Newtonian fluid with comparable viscosity. As a result, the linearity of the sperm movement increased. Additionally, increasing the viscosity brought about large changes in the sperm flagellar shape. At low viscosities, the entire flagellum moved in a curved flapping motion, whereas in the high-viscosity, only the tip of the flagellum flapped. These results suggest that the bovine sperm has evolved to swim toward the egg as quickly as possible in the actual oviduct fluid, which is a high-viscosity non-Newtonian fluid.
Experimental study on the effect of flow in microfluidic channel on bovine sperm navigation
The navigation mechanism of mammalian sperm in the female reproductive tract is unclear owing to its complex process. This study performed an in vitro experiment using the microfluidic channel with two reservoirs to investigate the effect of fluid flow on the swimming properties of the bovine sperm. The width and height of the manufactured channel were 200 and 20 μm, respectively. The flow in the microchannel occurs because of the hydraulic head difference between the two reservoirs. Sperm with positive rheotaxis proceed in the opposite direction of the flow in the channel after swimming up the downstream reservoir. This study focused on the effect of the flow in the microfluidic channel on sperm motility. It was observed that sperm mostly moved along the channel wall and accumulated near the wall away from the downstream reservoir. The existence of fluid flow in the channel brought about an increase in the ratio of the sperm with positive rheotaxis. Furthermore, the experimental results indicated that the motility of sperm swimming against the flow along the wall increased away from the downstream reservoir. These results will provide useful information to understand the mechanism of sperm navigation for in vivo fertilization.
Numerical simulations of blood cell flow in non-Newtonian fluid
We investigated how non-Newtonian viscosity behavior affects the flow characteristics of blood cells. Our findings offer insight about how shear thinning affects the dispersion of liposome-encapsulated hemoglobin and red blood cells in blood. The lattice Boltzmann method was used for fluid calculations, and the rheological properties of the non-Newtonian fluid were modeled with power-law relationships. The deformable three-dimensional red blood cell model was applied. First, we investigated the effects of shear thinning on the flow behavior of single blood cell. Simulation results indicate that shear thinning promotes the axial concentration of red blood cells. Next, varied the hematocrit to see how mutual interference between blood cells affects flow. At low hematocrit, shear thinning clearly promotes the axial concentration of red blood cells. As the hematocrit increases, in contrast, mutual interference has a greater effect, which counteracts shear thinning so the red blood cell distribution resembles the distribution within a Newtonian fluid.
Study of the Partitioning of Red Blood Cells Through Asymmetric Bifurcating Microchannels
Purpose The heterogeneous distribution of red blood cells (RBCs) in the microcirculatory system is a complicated phenomenon because many factors influence how they are partitioned at microvascular bifurcations. In this study, we investigated the RBC partitioning mechanism by fabricating an in vitro experimental apparatus. Methods The apparatus comprised a bifurcating, microfluidic channel, and the flow rate through the channels can be controlled readily over a wide range. The division turning point at which an RBC trajectory changes from one bifurcation to the other was identified via particle-tracking velocimetry on individual RBCs. Results The experimental results were close to the theoretical predictions and numerical simulations. The hematocrit variation before and after bifurcation was quantitatively estimated by image analysis and compared to the prediction based on Pries’ empirical model. The Zweifach–Fung effect was enhanced in the smaller fractional flow, increasing the RBC flux bias. Moreover, a cell-free layer with axial symmetry was formed in the parent channel, and an asymmetric cell-free layer was formed immediately after bifurcation. Conclusions These obtained results will help clarify the RBC partitioning mechanism at microvascular bifurcations.
Numerical investigation of oxygen transport by hemoglobin-based carriers through microvessels
The small size of hemoglobin-based oxygen carriers (HBOCs) may expand the realm of new treatment possibilities for various circulatory diseases. The parametric evaluation of HBOC performance for oxygen transport within tissue is essential for effectively characterizing its performance for each circulatory disease assessed. Thus, the overarching objective of this present study was to numerically investigate the reaction–diffusion phenomenon of oxygenated HBOCs and oxygen on tissues through microvessels. We considered dissociation rate coefficients, oxygen affinity, and diffusion coefficients due to Brownian motion as the biophysical parameters for estimating HBOC performance for oxygen transport. A two-dimensional computational domain, including vessel and tissue regions, was, therefore, accordingly assumed. It was observed that HBOC flows in a microvessel with a diameter of 25 μm and a length of 1 mm, and that the dissociated oxygen diffuses to the tissue region. The results indicated that oxyhemoglobin saturation and partial oxygen tension in a downstream region changed according to each biophysical parameter of HBOC. Moreover, the change in oxygen consumption rate in the tissue region had considerable influence on the oxyhemoglobin saturation level within the vessel. Comparison between simulation results and existing in vitro experimental data of actual HBOCs and RBC showed qualitatively good agreement. These results provide important information for the effective design of robust HBOCs in future.
Red Blood Cell Partitioning Using a Microfluidic Channel with Ladder Structure
This study investigated the partitioning characteristics of red blood cells (RBCs) within capillaries, with a specific focus on ladder structures observed near the end of the capillaries. In vitro experiments were conducted using microfluidic channels with a ladder structure model comprising six bifurcating channels that exhibited an anti-parallel flow configuration. The effects of various factors, such as the parent channel width, distance between branches, and hematocrit, on RBC partitioning in bifurcating channels were evaluated. A decrease in the parent channel width resulted in an increase in the heterogeneity in the hematocrit distribution and a bias in the fractional RBC flux. Additionally, variations in the distance between branches affected the RBC distribution, with smaller distances resulting in greater heterogeneity. The bias of the RBC distribution in the microchannel cross section had a major effect on the RBC partitioning characteristics. The influence of hematocrit variations on the RBC distribution was also investigated, with lower hematocrit values leading to a more pronounced bias in the RBC distribution. Overall, this study provides valuable insights into RBC distribution characteristics in capillary networks, contributing to our understanding of the physiological mechanisms of RBC phase separation in the microcirculatory system. These findings have implications for predicting oxygen heterogeneity in tissues and could aid in the study of diseases associated with impaired microcirculation.
Prediction of sperm motion behavior in microfluidic channel using sperm swimming model
Several investigations have recently been conducted using microfluidic channels to sort highly motile sperm and thereby increase the probability of fertilization. To further enhance the efficiency of sperm sorting, predicting sperm movement in microfluidic channels through simulation techniques could be beneficial. In this study, we constructed a sperm swimming model based on the concept of an agent-based model. This model allows analysis at the same spatio–temporal scale similar to microfluidic channels. Sperm movement was simplistically modeled as a random walk, utilizing the distribution of sperm velocity and deflection angle obtained from experimental data. We have developed a thigmotaxis model to describe the phenomenon where sperm near the wall exhibit a reduced tendency to move away from it. Additionally, we created a rheotaxis model, in which sperm reorient in the direction opposite to the flow depending on the shear rate. Using these models, we investigated sperm behaviors within a microchannel featuring a tapered area. The results reveal that sperm accumulate within the tapered area, leading to a significant increase in sperm concentration for specific flow velocity ranges in the microchannel. This model provides valuable information for predicting the effects of sperm sorting in various microfluidic channels.
Study of bovine sperm motility in shear-thinning viscoelastic fluids
To elucidate the process whereby sperm arrive at an egg in the female reproductive organs, it is essential to investigate how rheological properties of the fluid around mammalian spermatozoa affect their motility. We examined the motility and flagellar waveform of bovine sperm swimming in a fluid with similar rheological properties as mammalian cervical mucus. The results indicated that the surrounding rheological properties largely affected the flagellar waveform of mammalian spermatozoa; in particular, shear-thinning viscoelastic fluid increased the progressive motility of the sperm. To investigate the influence of flagellar waveform on sperm motility in more detail, the waveform was expressed as a function and the progressive thrust of the sperm was calculated based on the empirical resistive force theory. The results of this study showed that the progressive thrust increased with the curvature of the flagellar tip. Moreover, we calculated the thrust efficiency of motile sperm. Results showed that the thrust efficiency in shear-thinning viscoelastic fluids was larger than that in Newtonian fluids, regardless of viscosity. This suggests that motile sperm in cervical mucus move efficiently by means of a motion mechanism that is suited to their surrounding environment.
Properties of a monopivot centrifugal blood pump manufactured by 3D printing
An impeller the same geometry as the impeller of a commercial monopivot cardiopulmonary bypass pump was manufactured using 3D printing. The 3D-printed impeller was integrated into the pump casing of the commercially available pump to form a 3D-printed pump model. The surface roughness of the impeller, the hydraulic performance, the axial displacement of the rotating impeller, and the hemolytic properties of the 3D-printed model were measured and compared with those of the commercially available model. Although the surface roughness of the 3D-printed model was significantly larger than that of the commercially available model, the hydraulic performance of the two models almost coincided. The hemolysis level of the 3D-printed model roughly coincided with that of the commercially available model under low-pressure head conditions, but increased greatly under high-pressure head conditions, as a result of the narrow gap between the rotating impeller and the pump casing. The gap became narrow under high-pressure head conditions, because the axial thrust applied to the impeller increased with increasing impeller rotational speed. Moreover, the axial displacement of the rotating impeller was twice that of the commercially available model, confirming that the elastic deformation of the 3D-printed impeller was larger than that of the commercially available impeller. These results suggest that trial models manufactured by 3D printing can reproduce the hydraulic performance of the commercial product. However, both the surface roughness and the deformation of the trial models must be considered to precisely evaluate the hemolytic properties of the model.
Theoretical consideration of the flow behavior in oscillating vocal fold
Self-excited oscillation of the vocal folds produces a source sound of the human voiced speech. The mechanism of the self-excitation remains elusive partly because characteristics of the flow in rapidly oscillating vocal folds are unclear. This paper deals with theoretical considerations of the flow behavior in oscillating constriction based on general flow equations. The cause-and-effect relationships between time-varying glottal width and physical variables such as glottal pressure, velocity, and volume flow are analytically derived as functions of oscillatory frequency through perturbation analysis. The result shows that the unsteady effect due to convective acceleration of vocal fold wall-induced flow becomes comparable in magnitude to the Bernoulli effect at a high but physiological frequency of phonation. Consequently, a phase difference between the vocal fold motion and glottal pressure appears, enabling self-excited oscillation. The phase-lead of the pressure compared to wall motion is described as a monotonically increasing function of the Strouhal number. The above two effects essentially play the dominant role in the glottal flow. These explicit descriptions containing flow-related variables are useful for understanding of the glottal aerodynamics particularly at high frequency range of the falsetto voice register.