Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
70 result(s) for "Ielasi, Alfonso"
Sort by:
Management and Long-Term Prognosis of Spontaneous Coronary Artery Dissection
The optimal management and short- and long-term prognoses of spontaneous coronary artery dissection (SCAD) remain not well defined. The aim of this observational multicenter study was to assess long-term clinical outcomes in patients with SCAD. In-hospital and long-term outcomes were assessed in 134 patients with documented SCAD, as well as the clinical impact and predictors of a conservative rather than a revascularization strategy of treatment. The mean age was 52 ± 11, years and 81% of patients were female. SCAD presented as an acute coronary syndromes in 93% of patients. A conservative strategy was performed in 58% of patients and revascularization in 42%. On multivariate analysis, distal versus proximal or mid location of dissection (odds ratio 9.27) and basal Thrombolysis In Myocardial Infarction (TIMI) flow grade 2 or 3 versus 0 or 1 (odds ratio 0.20) were independent predictors of conservative versus revascularization strategy. A conservative strategy was associated with better in-hospital outcomes compared with revascularization (rates of major adverse cardiac events 3.8% and 16.1%, respectively, p = 0.028); however, no significant differences were observed in the long-term outcomes. In conclusion, in this large observational study of patients with SCAD, angiographic features significantly influenced the treatment strategy, providing an excellent short- and long-term prognosis.
Advancements in Pulmonary Embolism Management: Current Approaches and Future Directions
Pulmonary embolism (PE) is one of the leading causes of cardiovascular mortality, with a high 30-day mortality rate. Despite clear treatment guidelines based on patient risk profiles, evidence suggests a discrepancy between clinical practice worldwide and the recommendations outlined in these guidelines. This deviation is often due to the comorbidities present in patients with PE, which complicate management decisions. As a result, alongside traditional standard-of-care treatments, novel emerging therapies are being explored to address these challenges. This review aims to provide an overview of the current epidemiology, initial assessment strategies, conventional treatment options, and emerging therapeutic approaches for PE.
Back to the future: the role of DCB for the treatment of coronary bifurcation
Coronary bifurcation lesion (CBL) is a common but challenging scenario in percutaneous coronary interventions. Drug-coated balloons (DCBs) are modern devices with attractive perspective in CBL treatment. In-stent restenosis, small vessel and diffuse de-novo coronary artery disease have been, so far, considered the ideal scenario for DCBs application. Studies assessing DCBs in de-novo CBL demonstrated the safety and efficacy of this strategy. However, the heterogeneity of the study populations and the presence of methodological limitations prevent from drawing definite recommendations. Considering that the best treatment of bifurcations has not yet been defined, the “leaving nothing behind” philosophy will be the topic of future studies.
Incidence, Management, Immediate and Long-Term Outcome of Guidewire and Device Related Grade III Coronary Perforations (from G3CAP - Cardiogroup VI Registry)
Ellis grade III coronary artery perforations (G3-CAP) remain a life-threatening complication of percutaneous coronary intervention (PCI), with high morbidity and mortality and lack of consensus regarding optimal treatment strategies. We reviewed all PCIs performed in 10 European centers from 1993 to 2019 recording all G3-CAP along with management strategies, in-hospital and long-term outcome according to Device-related perforations (DP) and Guidewire-related perforations (WP). Among 106,592 PCI (including 7,773 chronic total occlusions), G3-CAP occurred in 311 patients (0.29%). DP occurred in 194 cases (62.4%), more commonly in proximal segments (73.2%) and frequently secondary to balloon dilatation (66.0%). WP arose in 117 patients (37.6%) with chronic total occlusions guidewires involved in 61.3% of cases. Overall sealing success rate was 90.7% and usually required multiple maneuvers (80.4%). The most commonly adopted strategies to obtain hemostasis were prolonged balloon inflation (73.2%) with covered stent implantation (64.4%) in the DP group, and prolonged balloon inflation (53.8%) with coil embolization (41%) in the WP group.  Procedural or in-hospital events arose in 38.2% of cases: mortality was higher after DP (7.2% vs 2.6%, p = 0.05) and acute stent thrombosis 3-fold higher (3.1% vs 0.9%, p = 0.19). At clinical follow-up, median 2 years, a major cardiovascular event occurred in one-third of cases (all-cause mortality 8.2% and 7.1% respectively, without differences between groups). In conclusion, although rare and despite improved rates of adequate perforation sealing G3-CAP cause significant adverse events. DP and WP result in different patterns of G3-CAP and management strategies should be based on this classification.
Transcatheter vs surgical aortic valve replacement in intermediate-surgical-risk patients with aortic stenosis: A propensity score–matched case-control study
Limited real-world data comparing outcomes after transcatheter (TAVR) and surgical aortic valve replacement (SAVR) in intermediate-surgical-risk patients with aortic stenosis are available. We identified 182 consecutive patients who underwent TAVR via the transfemoral (TF) route (November 2007–February 2011) and 111 moderate-to-high-risk historical case controls undergoing SAVR (August 2003–July 2008). Using propensity score matching based on clinical characteristics and surgical risk scores, we compared clinical outcomes in 111 matched patients. Valve Academic Research Consortium definitions were applied for end point adjudication. Baseline clinical characteristics, in particular Logistic European System for Cardiac Operative Risk Evaluation (23.2 ± 15.1 vs 24.4 ± 13.4) and Society of Thoracic Surgeons score (4.6 ± 2.3 vs 4.6 ± 2.6), were well matched between groups. Transfemoral TAVR was associated with more vascular complications (33.3% vs 0.9%, P < .001). On the other hand, acute kidney injury was more frequent after SAVR (8.1% vs 26.1%, P < .001). The rates of all-cause mortality in both TF-TAVR and SAVR groups was1.8% at 30 days (P = 1.00) and 6.4% and 8.1%, respectively, at 1 year (P = .80). At 1 year, the rate of cerebrovascular events was similar in the 2 groups (4.6% vs 9.1%, P = .19). In this real-world cohort of intermediate-surgical-risk patients with aortic stenosis, TF-TAVR and SAVR were associated with similar mortality rates during follow-up but with a different spectrum of periprocedural complications. Furthermore, the survival rate after TF-TAVR in this group of elderly patients with intermediate Society of Thoracic Surgeons score was encouraging.
Clinical Comparison With Short-Term Follow-Up of Bioresorbable Vascular Scaffold Versus Everolimus-Eluting Stent in Primary Percutaneous Coronary Interventions
Objective of this study was to assess the clinical performance of bioresorbable vascular scaffold (BVS) compared to everolimus-eluting stent (EES) in subjects with ST-segment elevation myocardial infarction (STEMI). We included all consecutive patients with STEMI who underwent percutaneous coronary intervention (PCI) with BVS implantation in centers participating to the Italian ABSORB Prospective Registry (BVS-RAI) and PCI with EES in the same centers during the same period. The 2 groups were compared. The primary end point was patient-oriented composite end point (POCE) including cardiac death, myocardial infarction, and target lesion revascularization (TLR) at the longest available follow-up. BVS or EES thrombosis at follow-up was also evaluated. Of the 563 patients with STEMI included, 122 received BVS and 441 EES. Procedural success was obtained in 549 (97.5%) cases without significant differences between the 2 groups (BVS 99.3% vs EES 97.0%, p = 0.2). At a median of 220-day (interquartile range 178 to 369) follow-up, no significant differences were observed in terms of POCE (BVS 4.9% vs EES 7.0%, p = 0.4); death (BVS 0.8%, EES 2.0%, p = 0.4), MI (BVS 4.1%, EES 2.0%, p = 0.2), TLR (BVS 4.1%, EES 4.5%, p = 0.8), device thrombosis (BVS 2.5%, EES 1.4%, p = 0.4). All TLR cases were successfully managed with re-PCI in both groups. A propensity matching of the study populations showed no significant differences regarding POCE at the longest available follow-up (odds ratio 0.53, 0.1 to 4.3). In conclusion, in this direct prospective comparison, BVS was associated with similar clinical results compared to EES in the STEMI setting. Larger and adequately powered randomized trials are needed to fully assess the potential clinical benefit of BVS versus the current standard of care in patients with STEMI.
Clinical outcomes of the Myval transcatheter heart valve system in patients with severe aortic valve stenosis: a two-year follow-up observational study
Limited data exist on long-term follow-up of severe aortic stenosis (SAS) patients who have undergone transcatheter aortic valve implantation (TAVI) with a new generation, balloon expandable Myval transcatheter heart valve (THV). Thus, we sought to investigate the performance and 2-year clinical outcome of the Myval THV system based on Valve Academic Research Consortium-3 (VARC-3) criteria. A multi-centre, registry-based, observational study was conducted, which included 207 consecutive degenerative SAS patients, from Turkey ( = 128), Italy ( = 58), and Greece ( = 21) (mean [standard deviation] 81 (7) years, 94 [45%] men; 73% NYHA III or IV; EuroSCORE II 5.2% [2.4%]); all patients underwent TAVI with Myval. Patients were followed up at 1 year and 2 years after implantation. Clinical and procedural outcomes were defined according to VARC-3 criteria. Technical success was observed in 204 (99%), device success was observed in 189 (91%), early safety was observed in 161 (78%), and clinical efficacy was observed in 163 (79%) patients. The 30-day death rate was 7.7%; of these, 3.4% were due to cardiovascular reasons. All-cause and cardiovascular mortality rates were 9.7% and 4.3% at 1-year follow-up, and 17.4% and 9.7% at 2-year follow-up, respectively. Incidence of ≥ moderate paravalvular leak (PVL) at 30 days, 1 year and 2 years of follow-up were 3.4%, 4.3% and 4.8%. A total of 11.1% of patients required a permanent pacemaker implantation (PPI) at 30 days after implantation, while the cumulative rate of PPI at 2 years was 12.1%. In this cohort of patients with SAS, the Myval was found to be safe and effective in up to 2 years of follow-up.
In-Hospital and 1-Year Outcomes of Rotational Atherectomy and Stent Implantation in Patients With Severely Calcified Unprotected Left Main Narrowings (from the Multicenter ROTATE Registry)
Heavily calcified unprotected left main (ULM) disease continues to be a challenging situation and represent a high-risk subset for interventional cardiologist. To date, there are limited data investigating the results after rotational atherectomy (RA) in this setting. The aim of this study was to investigate the in-hospital and 1-year outcomes after RA of heavily calcified ULM lesions. A retrospective cohort analysis was performed on all calcified patients with ULM (n = 86) enrolled in the multicenter international ROTATE registry (overall patients, n = 962). End points of the study were the in-hospital and 1-year incidence of major adverse cardiovascular events (MACE): a composite of death, myocardial infarction, and target-vessel revascularization in the ULM versus non-ULM group. Patients in the ULM group were older (p = 0.01) and more frequently with diabetes (p = 0.001) compared with the non-ULM group, whereas intravascular ultrasound guidance was higher, even if not systematic, in the ULM group (p <0.001). No difference was reported between ULM versus non-ULM groups in terms of in-hospital MACE (5.8% vs 8%). At 1 year, MACE rate was higher in ULM versus non-ULM (26.4% vs 14.9%, p = 0.002) mostly driven by target-vessel revascularization (20.3% vs 12.7%, p = 0.05). Even definite/probable stent thrombosis rate was higher in the ULM group (3.9% vs 0.8%). All these events were subacute and 2/3 (75%) were fatal. In conclusion, our multicenter experience shows that RA followed by stent implantation in patients with heavily calcified ULM narrowing is feasible and associated with good in-hospital results. Patient (age and diabetes) and procedural aspects (relatively low intravascular ultrasound guidance) may affect the worse subacute mid-term prognosis in the more complex ULM group.
Quantitative Angiographic Assessment of Aortic Regurgitation after Transcatheter Aortic Valve Implantation among Three Balloon-Expandable Valves
The aim of the present analysis is to compare the quantitative angiographic aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) among three balloon-expandable valves. Quantitative videodensitometric aortography is an objective, accurate, and reproducible tool for adjudication of AR following TAVI. This is a retrospective corelab analysis, independent from industry, of aortograms from patients treated with TAVI using the balloon-expandable Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd., India), Sapien 3, and XT THVs (Edwards Lifesciences, Irvine, CA, USA). The study comprised of 108 analyzable aortograms from consecutive patients in a multicenter European registry who underwent Myval THV implantation. The results of quantitative assessment of AR in the Sapien 3 THV (n = 397) and Sapien XT THV (n = 239) were retrieved from a published pooled database. The Myval THV had the lowest proportion of patients with moderate or severe angiographic quantitative AR (2.8%) compared to the Sapien 3 THV (8.3%; p = 0.049) and Sapien XT THV (10.9%; p = 0.012). Furthermore, the Myval THV had the lowest mean angiographic quantitative AR (6.3 ± 6.3%), followed by Sapien 3 THV (7.6 ± 7.1%) and Sapien XT THV (8.8 ± 7.5%), and it was significantly lower than that of the Sapien XT THV (p = 0.006), but not significantly different from Sapien 3 THV (p = 0.246). The Myval THV, in comparison with other BEV's analyzed in our database, showed a lower occurrence of moderate or severe AR after TAVI. These results should be confirmed in prospective cohorts of randomized patients with head-to-head THV comparisons.
Complications Following Percutaneous Mitral Valve Repair
Mitral valve disease affects more than 4 million people in the United States and it is the second most prevalent valvulopathy in Europe. The gold standard of treatment in these patients is surgical repair or mitral valve replacement. In the last decade, numerous transcatheter therapies have been developed to overcome the increased number of subjects with symptomatic severe mitral regurgitation and high surgical risk. The Mitraclip (Abbott Vascular, Menlo Park, CA), PASCAL (Edwards Lifesciences, Irvine, CA, USA), the Carillon™ Mitral Contour System™ (Cardiac Dimension Inc., Kirkland, WA, USA), the Mitralign™ (Mitralign, Tewksbury, Massachusetts), and the Cardioband (Edwards Lifesciences, Irvine, CA) are the principal percutaneous devices for mitral valve repair. We present an evidence-based clinical update that provides an overview of these technologies and their potential complications.