Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
9 result(s) for "Igawa, Gene"
Sort by:
Antibody response and seroprevalence in healthcare workers after the BNT162b2 vaccination in a University Hospital at Tokyo
In 2020, we reported a low seroprevalence of N-specific antibodies in 4147 health care workers (HCWs) at a frontline hospital in Tokyo, Japan. In Japan, a vaccine campaign was launched in early 2021. We re-evaluated seroprevalences of N- and S-specific antibodies in 2202 HCWs who took two doses of the BNT162b2 vaccine. In 2021, N-specific seroprevalence remains as low as 1.59%. The seroprevalences were comparable among all HCWs regardless of exposure levels. Almost all of the HCWs elicited S-specific antibodies after vaccination. However, the HCWs who had COVID-19 elicited higher S-specific antibody titers than those who did not have COVID-19. In the HCWs without a history of COVID-19, 1.1% (23 out of 2185) were seropositive with N-specific antibodies, indicating the existence of asymptomatic infections. Also, S-specific antibody titers were higher in females and younger HCWs, and in those who had severe side effects. However, S-specific antibody titers were lower depending on the number of days after the second dose of vaccination specifically in elderly individuals. In conclusion, this study indicates N-specific seroprevalence remains low in HCWs at a frontline hospital in Tokyo. The mRNA vaccine elicited S-specific antibody in HCWs, however, the titers decreased as the days proceeded.
Performance evaluation of the Roche Elecsys® Anti-SARS-CoV-2 immunoassays by comparison with neutralizing antibodies and clinical assessment
Quantitative measurement of SARS-CoV-2 neutralizing antibodies is highly expected to evaluate immune status, vaccine response, and antiviral therapy. The Elecsys® Anti-SARS-CoV-2 S (Elecsys® anti-S) was developed to measure anti-SARS-CoV-2 S proteins. We sought to investigate whether Elecsys® anti-S can be used to predict neutralizing activities in patients’ serums using an authentic virus neutralization assay. One hundred forty-six serum samples were obtained from 59 patients with COVID-19 at multiple time points. Of the 59 patients, 44 cases were included in Group M (mild 23, moderate 21) and produced 84 samples (mild 35, moderate 49), while 15 cases were included in Group S (severe 11, critical 4) and produced 62 samples (severe 43, critical 19). The neutralization assay detected 73% positive cases, and Elecsys® anti-S and Elecsys® Anti-SARS-CoV-2 (Elecsys® anti-N) showed 72% and 66% positive cases, respectively. A linear correlation between the Elecsys® anti-S assay and the neutralization assay were highly correlated ( r = 0.7253, r 2 = 0.5261) than a linear correlation between the Elecsys® anti-N and neutralization assay ( r = 0.5824, r 2 = 0.3392). The levels of Elecsys® anti-S antibody and neutralizing activities were significantly higher in Group S than in Group M after 6 weeks from onset of symptoms ( p < 0.05). Conversely, the levels of Elecsys® anti-N were comparable in both groups. Three immunosuppressed patients, including cancer patients, showed low levels of anti-S and anti-N antibodies and neutralizing activities throughout the measurement period, indicating the need for careful follow-up. Our data indicate that Elecsys® anti-S can predict the neutralization antibodies in COVID-19.
Increased SARS-CoV-2 seroprevalence and spread of infection without awareness among healthcare workers through 2020–2022 in a Japanese medical center
Despite Japan’s high vaccination coverage, daily numbers of new COVID-19 cases have been high. However, studies on the seroprevalence among Japanese people and the causative factors for rapid spread have remained limited. In this study, we aimed to examine the seroprevalence and associated factors in healthcare workers (HCWs) of a medical center in Tokyo using blood samples drawn at annual check-ups from 2020 to 2022. We found that of the 3,788 HCWs in 2022 (by mid-June), 669 were seropositive for N-specific antibodies (tested by Roche Elecsys Anti-SARS-CoV-2 assay); the seroprevalence surged from 0.3% in 2020 and 1.6% in 2021 to 17.7% in 2022. Notably, our study found 325 (48.6%; 325/669) cases were infected without awareness. Among those with a previously PCR-confirmed SARS-CoV-2 infection during the past three years, 79.0% (282/357) were found after January 2022, after the Omicron variant was first detected in Tokyo at the end of 2021. This study indicates the fast spread of the SARS-CoV-2 among HCWs during the Omicron surge in Japan. The high percentage of infection without awareness may be a key driving factor causing rapid person-to-person transmission, as shown in this medical center with high vaccination coverage and strict infection control measures.
Assessment of antibody dynamics and neutralizing activity using serological assay after SARS-CoV-2 infection and vaccination
The COVID-19 antibody test was developed to investigate the humoral immune response to SARS-CoV-2 infection. In this study, we examined whether S antibody titers measured using the anti-SARS-CoV-2 IgG II Quant assay (S-IgG), a high-throughput test method, reflects the neutralizing capacity acquired after SARS-CoV-2 infection or vaccination. To assess the antibody dynamics and neutralizing potency, we utilized a total of 457 serum samples from 253 individuals: 325 samples from 128 COVID-19 patients including 136 samples from 29 severe/critical cases (Group S), 155 samples from 71 mild/moderate cases (Group M), and 132 samples from 132 health care workers (HCWs) who have received 2 doses of the BNT162b2 vaccinations. The authentic virus neutralization assay, the surrogate virus neutralizing antibody test (sVNT), and the Anti-N SARS-CoV-2 IgG assay (N-IgG) have been performed along with the S-IgG. The S-IgG correlated well with the neutralizing activity detected by the authentic virus neutralization assay (0.8904. of Spearman’s rho value, p < 0.0001) and sVNT (0.9206. of Spearman’s rho value, p < 0.0001). However, 4 samples (2.3%) of S-IgG and 8 samples (4.5%) of sVNT were inconsistent with negative results for neutralizing activity of the authentic virus neutralization assay. The kinetics of the SARS-CoV-2 neutralizing antibodies and anti-S IgG in severe cases were faster than the mild cases. All the HCWs elicited anti-S IgG titer after the second vaccination. However, the HCWs with history of COVID-19 or positive N-IgG elicited higher anti-S IgG titers than those who did not have it previously. Furthermore, it is difficult to predict the risk of breakthrough infection from anti-S IgG or sVNT antibody titers in HCWs after the second vaccination. Our data shows that the use of anti-S IgG titers as direct quantitative markers of neutralizing capacity is limited. Thus, antibody tests should be carefully interpreted when used as serological markers for diagnosis, treatment, and prophylaxis of COVID-19.
Comparison of the clinical performance and usefulness of five SARS-CoV-2 antibody tests
We examined the usefulness of five COVID-19 antibody detection tests using 114 serum samples at various time points from 34 Japanese COVID-19 patients. We examined Elecsys Anti-SARS-CoV-2 from Roche, and four immunochromatography tests from Hangzhou Laihe Biotech, Artron Laboratories, Chil, and Nadal. In the first week after onset, Elecsys had 40% positivity in Group S (severe cases) but was negative in Group M (mild-moderate cases). The immunochromatography kits showed 40–60% and 0–8% positivity in Groups S and M, respectively. In the second week, Elecsys showed 75% and 50% positivity, and the immunochromatography tests showed 5–80% and 50–75% positivity in Groups S and M, respectively. After the third week, Elecsys showed 100% positivity in both groups. The immunochromatography kits showed 100% positivity in Group S. In Group M, positivity decreased to 50% for Chil and 75–89% for Artron and Lyher. Elecsys and immunochromatography kits had 91–100% specificity. Elecsys had comparable chronological change of cut-off index values in the two groups from the second week to the sixth week. The current SARS-CoV-2 antibody detection tests do not provide meaningful interpretation of severity and infection status. Its use might be limited to short-term epidemiological studies.
Activation of SARS-CoV-2 neutralizing antibody is slower than elevation of spike-specific IgG, IgM, and nucleocapsid-specific IgG antibodies
COVID-19 antibody testing has been developed to investigate humoral immune response in SARS-CoV-2 infection. To assess the serological dynamics and neutralizing potency following SARS-CoV-2 infection, we investigated the neutralizing (NT) antibody, anti-spike, and anti-nucleocapsid antibodies responses using a total of 168 samples obtained from 68 SARS-CoV-2 infected patients. Antibodies were measured using an authentic virus neutralization assay, the high-throughput laboratory measurements of the Abbott Alinity quantitative anti-spike receptor-binding domain IgG (S-IgG), semiquantitative anti-spike IgM (S-IgM), and anti-nucleocapsid IgG (N-IgG) assays. The quantitative measurement of S-IgG antibodies was well correlated with the neutralizing activity detected by the neutralization assay (r = 0.8943, p < 0.0001). However, the kinetics of the SARS-CoV-2 NT antibody in severe cases were slower than that of anti-S and anti-N specific antibodies. These findings indicate a limitation of using the S-IgG antibody titer, detected by the chemiluminescent immunoassay, as a direct quantitative marker of neutralizing activity capacity. Antibody testing should be carefully interpreted when utilized as a marker for serological responses to facilitate diagnostic, therapeutic, and prophylactic interventions.
Performance evaluation of the Roche Elecsys® Anti-SARS-CoV-2 immunoassays by comparison with neutralizing antibodies and clinical assessment
Quantitative measurement of SARS-CoV-2 neutralizing antibodies is highly expected to evaluate immune status, vaccine response, and antiviral therapy. The Elecsys® Anti-SARS-CoV-2 S (Elecsys® anti-S) was developed to measure anti-SARS-CoV-2 S proteins. We sought to investigate whether Elecsys® anti-S can be used to predict neutralizing activities in patients' serums using an authentic virus neutralization assay. One hundred forty-six serum samples were obtained from 59 patients with COVID-19 at multiple time points. Of the 59 patients, 44 cases were included in Group M (mild 23, moderate 21) and produced 84 samples (mild 35, moderate 49), while 15 cases were included in Group S (severe 11, critical 4) and produced 62 samples (severe 43, critical 19). The neutralization assay detected 73% positive cases, and Elecsys® anti-S and Elecsys® Anti-SARS-CoV-2 (Elecsys® anti-N) showed 72% and 66% positive cases, respectively. A linear correlation between the Elecsys® anti-S assay and the neutralization assay were highly correlated (r = 0.7253, r2 = 0.5261) than a linear correlation between the Elecsys® anti-N and neutralization assay (r = 0.5824, r2 = 0.3392). The levels of Elecsys® anti-S antibody and neutralizing activities were significantly higher in Group S than in Group M after 6 weeks from onset of symptoms (p < 0.05). Conversely, the levels of Elecsys® anti-N were comparable in both groups. Three immunosuppressed patients, including cancer patients, showed low levels of anti-S and anti-N antibodies and neutralizing activities throughout the measurement period, indicating the need for careful follow-up. Our data indicate that Elecsys® anti-S can predict the neutralization antibodies in COVID-19.
P1.34 Donor of mosaic pena gene of ceftriaxone resistant neisseria gonorrhoeae fc428 and gu140106
IntroductionGonorrhoea is a global health concern because N. gonorrhoeae has now acquired resistance to antibiotics including the 3rd generation cephalosporin, ceftriaxone. Mosaic structure in penicillin-binding protein 2 gene (penA) is the main cause of ceftriaxone resistance which is formed by natural transformation of DNA of ceftriaxone-resistant (CROR) commensal Neisseria spp. However, none of the previous studies has fully elucidated the source of transformed DNA. In this study, we show that genetic comparison between CROR-N. gonorrhoeae strains (GU140106 and FC428) and CROR –Neisseria commensals.MethodsCROR-Neisseria commensals were isolated from pharyngeal swabs. Genome sequence was obtained by MiSeq, Illumina, and the sequence of penA flanking region (mraW-NGO1540-penA-murE-dcaA) was obtained using the N. gonorrhoeae FA1090 as a reference sequence. Alignment of the compared sequences were prepared by CLUSTALW. Species identification of Neisseria commensals was performed using phylogeny constructed by 53 ribosomal proteins (rps) sequences.ResultsBased on the sequence similarity of penA gene, two CROR-Neisseria commensals were speculated to be the origin of each mosaic penA of GU140106 and FC428. Both of the candidates were N. cinerea according to the rps phylogeny. The DNA region including penA originated from N. cinerea which consist the part of mosaic penA in the CROR-N. gonorrhoeae was about 1.3 kb including of parts of penA and murE. Further analysis revealed that mosaic penA of GU140106 occurred by recombination between CROR-N. cinerea and CROS -N. gonorrhoeae which the NG-MAST type was same with GU140106. The mosaic penA of FC428 was also thought to emerged in the same way with GU140106. However, there was a limitation because of the lack of CROS-N. gonorrhoeae that has the same NG-MAST type with FC428.ConclusionThe two CROR-N. gonorrhoeae, GU140106 and FC428, might acquire resistance by homologous recombination with Neisseria commensals, and N. cinerea might be the donor of mosaic penA which causes resistance to ceftriaxone in N. gonorrhoeae.