Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
33 result(s) for "Jeon, Seong-Ran"
Sort by:
Rebleeding Rate and Risk Factors for Rebleeding after Device-Assisted Enteroscopy in Patients with Obscure Gastrointestinal Bleeding: A KASID Multicenter Study
Introduction: The impact of device-assisted enteroscopy (DAE) on long-term rebleeding in patients with obscure gastrointestinal bleeding (OGIB) exhibiting detectable small-bowel lesions remains unclear. We investigated the long-term rebleeding rate and predictive factors for DAE in patients with OGIB. Method: Patients with OGIB with small bowel lesions detected through DAE were enrolled at three Korean tertiary hospitals. Predictive risk factors associated with rebleeding were analyzed using the Cox regression analysis. Results: From April 2008 to April 2021, 141 patients were enrolled, including 38 patients (27.0%) with rebleeding. The rebleeding rates at 1, 2, and 3 years were 25.0%, 29.6%, and 31.1%, respectively. The Cox regression analysis revealed that multiple small-bowel lesions (hazard ratio [HR]: 2.551, 95% confidence interval [CI]: 1.157–5.627, p = 0.020), the need for more than five packed red blood cells (RBC) transfusions (HR: 2.704, 95% CI: 1.412–5.181, p = 0.003), and ulcerative lesions (HR: 1.992, 95% CI: 1.037–3.826, p = 0.039) were positively associated with rebleeding. Therapeutic interventions for patients with detectable lesions, overt bleeding (vs. occult bleeding), comorbidities, and medications were not associated with rebleeding. Conclusion: More than 25% of patients with OGIB having detectable small-bowel lesions had rebleeding. Patients with multiple lesions, a requirement of more than five packed RBC transfusions, and ulcerative lesions were associated with a higher risk of rebleeding.
Comparison of a novel mini-oral sulfate tablet and the conventional oral sulfate tablet in bowel preparation for colonoscopy: a prospective, randomized, investigator-blinded, multicenter, non-inferior, phase 3 trial
Background and aimsThe use of conventional oral sulfate tablets (OSTs) has gained popularity; nonetheless, they may be not only inconvenient to swallow but also difficult to dissolve. A novel mini-OST has recently been developed to enhance compliance with conventional OST use. This study aimed to compare the efficacy, tolerability, and safety between mini-OST and conventional OST.MethodsThis was a prospective, randomized, investigator-blinded, multicenter, and non-inferior phase 3 trial conducted between September 2022 and December 2022. The efficacy, safety, and tolerability were compared between mini-OST and conventional OST.ResultsExactly 83 patients were evaluated based on a full analysis set (FAS), whereas 82 patients were evaluated as a per-protocol set (PPS). With respect to the efficacy of preparation, successful and high-quality preparation was excellent in the mini-OST and conventional OST groups on both FAS and PPS analyses, without significant differences between the two groups. On the FAS analysis, the satisfaction and tolerability scores were high in both groups, without significant differences. The first bowel movement after taking the investigational product occurred 30 min earlier in the mini-OST group than in the OST group. Mild, moderate, and severe adverse events (AEs) were comparable between the two groups; however, any AEs were more common in the mini-OST group than in the conventional OST group overall.ConclusionsCompared with conventional OST, the novel mini-OST preparation showed similar efficacy, tolerability, and safety, including mild eight solicited AEs and moderate-to-severe AEs.Clinical trial registration NCT05670470.
Current Evidence for the Management of Inflammatory Bowel Diseases Using Fecal Microbiota Transplantation
Purpose of ReviewFecal microbiota transplantation (FMT) has been investigated as a potential treatment for inflammatory bowel disease (IBD). This review examines current evidence around the efficacy and safety of FMT for patients with IBD.Recent FindingsRandomized controlled trials (RCTs) and meta-analyses have suggested that FMT may facilitate clinical and endoscopic remission in patients with active ulcerative colitis (UC). Although the evidence for FMT in Crohn’s disease (CD) is more limited, positive outcomes have been observed in small cohort studies. Most adverse events (AEs) were mild and included transient gastrointestinal symptoms. Serious adverse events (SAEs) did not differ significantly between the FMT and control groups, and a marginal increased rate of IBD flares following FMT was observed. Microbiota analysis following FMT showed increased intestinal bacterial diversity and a shift towards the donor microbial profile in recipients’ stools.SummaryFMT for patients with IBD is promising as RCTs have shown the benefit of FMT for UC, although the efficacy of FMT for CD is less clear. Further large and well-designed trials are necessary to resolve critical issues such as the donor selection, the ideal route of administration, duration, frequency of FMT, and the long-term sustained efficacy and safety.
Clinical Characteristics and Treatment Outcomes of Cryptogenic Multifocal Ulcerous Stenosing Enteritis in Korea
Background Cryptogenic multifocal ulcerous stenosing enteritis (CMUSE) is a rare disease that is characterized by multiple, recurring small intestinal ulcers with stenosis of unknown causes. The aim of this study was to investigate the clinical characteristics and the treatment outcomes of patients with CMUSE in Korea. Methods We performed a multicenter study to retrospectively analyze clinical data from 20 patients who suffered from CMUSE between 1984 and 2012. Their clinical characteristics and long-term disease courses were investigated. Results The most common initial symptom of CMUSE was abdominal pain (14/20, 70 %). Small bowel series (13/20, 65 %), double-balloon enteroscopy (12/20, 60 %), CT enterography (12/20, 60 %), and capsule endoscopy (10/20, 50 %) were used to diagnose CMUSE. The strictures of the patients were located in the jejunum (5/20, 25 %), ileum (7/20, 35 %), and both jejunum and ileum (6/20, 30 %). The number of patients in a state of remission, persistent disease, and relapse at the end of follow-up were 13/20 (65 %), 2/20 (10 %), and 5/20 (25 %), respectively. The median relapse-free survival was of 67.1 months. Seventy-five percent relapse-free survivals for female and male patients were 93 and 9 months, respectively ( P  = 0.031). Conclusion CMUSE is difficult to diagnose and is an easily relapsing disease. Female patients might have a better prognosis than male patients in terms of the relapse-free time.
Reduced detection rate of artificial intelligence in images obtained from untrained endoscope models and improvement using domain adaptation algorithm
A training dataset that is limited to a specific endoscope model can overfit artificial intelligence (AI) to its unique image characteristics. The performance of the AI may degrade in images of different endoscope model. The domain adaptation algorithm, i.e., the cycle-consistent adversarial network (cycleGAN), can transform the image characteristics into AI-friendly styles. We attempted to confirm the performance degradation of AIs in images of various endoscope models and aimed to improve them using cycleGAN transformation. Two AI models were developed from data of esophagogastroduodenoscopies collected retrospectively over 5 years: one for identifying the endoscope models, Olympus CV-260SL, CV-290 (Olympus, Tokyo, Japan), and PENTAX EPK-i (PENTAX Medical, Tokyo, Japan), and the other for recognizing the esophagogastric junction (EGJ). The AIs were trained using 45,683 standardized images from 1,498 cases and validated on 624 separate cases. Between the two endoscope manufacturers, there was a difference in image characteristics that could be distinguished without error by AI. The accuracy of the AI in recognizing gastroesophageal junction was >0.979 in the same endoscope-examined validation dataset as the training dataset. However, they deteriorated in datasets from different endoscopes. Cycle-consistent adversarial network can successfully convert image characteristics to ameliorate the AI performance. The improvements were statistically significant and greater in datasets from different endoscope manufacturers [original → AI-trained style, increased area under the receiver operating characteristic (ROC) curve, P -value: CV-260SL → CV-290, 0.0056, P = 0.0106; CV-260SL → EPK-i, 0.0182, P = 0.0158; CV-290 → CV-260SL, 0.0134, P < 0.0001; CV-290 → EPK-i, 0.0299, P = 0.0001; EPK-i → CV-260SL, 0.0215, P = 0.0024; and EPK-i → CV-290, 0.0616, P < 0.0001]. In conclusion, cycleGAN can transform the diverse image characteristics of endoscope models into an AI-trained style to improve the detection performance of AI.
Histological Diagnostic Yield and Clinical Significance of the First Biopsy in Device-Assisted Enteroscopy in Patients with Small Bowel Diseases: A KASID Multicenter Study
Device-assisted enteroscopy (DAE) enables the direct visualization of small bowel lesions with histological diagnosis; however, few studies have described the diagnostic performance of enteroscopic biopsy. We investigated the diagnostic performance of enteroscopic biopsy. We used a nationwide multicenter enteroscopy database to identify patients who underwent DAE with biopsy for small bowel diseases. The patients were classified into the tumor and non-tumor groups according to the final diagnosis. They were also divided into diagnostic and non-diagnostic groups based on the enteroscopic biopsy results. The clinical significance of the first biopsy and histological diagnostic yield of DAE were analyzed. Among the 112 procedures investigated, 32 (28.9%) were diagnosed with tumors, and 80 (71.7%) were diagnosed with non-tumor diseases. The overall histological diagnostic yield of DAE was 43.7%. The histological diagnostic yield was significantly higher in the tumor than in the non-tumor group (81.2% vs. 28.8%, p < 0.001). The mean number of biopsies was significantly higher in the diagnostic than in the non-diagnostic group (5.6 ± 3.3 vs. 3.7 ± 2.1, p = 0.001). In the diagnostic group, 87.7% of the cases were histologically confirmed at the first biopsy. Therefore, the first biopsy should be performed carefully.
Capsule Endoscopy for Portal Hypertensive Enteropathy
Portal hypertensive enteropathy (PHE) is a mucosal abnormality of the small bowel that is observed in patients with portal hypertension (PH) and can lead to gastrointestinal bleeding and anemia. The pathogenesis is still not completely understood. The introduction of new endoscopic methods, including capsule endoscopy (CE) or balloon-assisted enteroscopy, has increased the detection of these abnormalities. CE can also serve as a road map for deciding subsequent interventions and evaluating the treatment effect. The prevalence of PHE is reportedly 40–70% in patients with PH. Endoscopic findings can be roughly divided into vascular and nonvascular lesions such as inflammatory-like lesions. Traditionally, PHE-associated factors include large esophageal varices, portal hypertensive gastropathy or colopathy, Child-Turcotte-Pugh class B or C, a history of variceal treatment, and acute gastrointestinal bleeding. More recently, on using scoring systems, a high computed tomography or transient elastography score was reportedly PHE-related factors. However, the prevalence of PHE and its related associated factors remain controversial. The management of PHE has not yet been standardized. It should be individualized according to each patient’s situation, the availability of therapy, and each institutional expertise.
Clinical Outcomes between P1 and P0 Lesions for Obscure Gastrointestinal Bleeding with Negative Computed Tomography and Capsule Endoscopy
Background: A simple classification for the relevance of lesions (P0, P1, and P2; no bleeding potential, less likely to bleed, and more likely to bleed, respectively) based on capsule endoscopy (CE) findings has been used. This study aimed at investigating rebleeding rates and predictive factors of P0 and P1 lesions after obtaining negative findings in both, CE and computed tomography (CT), for patients with obscure gastrointestinal bleeding (OGIB). Methods: Among 193 patients resulted in negative CE findings defined as P0 or P1 lesions, 84 patients with negative results on CT images were enrolled in this study. The rebleeding rates and predictive factors were assessed in the P0 and P1 groups. Results: Overall rebleeding rate in patients with negative CT and CE was 17.9%; 18.4% in the P0 group; 17.4% in the P1 group within a median follow-up duration of 18.5 months. In the P0 and P1 groups, the cumulative rebleeding rates were 9.2%, 25.4%, and 25.4%, and 6.9%, 11.8%, and 18.6% at 12, 24, and 60 months, respectively (p = 0.97). There were no independent rebleeding associated factors in the P0 group, whereas Charlson comorbidity index (CCI) (hazard ratio (HR) = 2.019, 95% confidence interval (CI): 1.158–3.519, p = 0.013), and initial low hemoglobin (Hb) level (<8 g/dL) (HR = 15.085, 95% CI: 1.182–192.514, p = 0.037) were independent predictive factors responsible for rebleeding in the P1 group. Conclusions: Despite having negative findings on CT and CE, patients with OGIB have a significant potential rebleeding risk. Although there was no significant difference in rebleeding rates between the P0 and P1 groups on CE, the P1 group, with CCI or low initial Hb level, should be cautiously observed after the first bleeding episode.
Pancreatic Resection Guided by Preoperative Intraductal Ultrasonography for Intraductal Papillary Mucinous Neoplasm
Successful treatment requires reliable preoperative assessment of the highly variable extension of intraductal papillary mucinous neoplasms (IPMNs). We aimed to determine the role of intraductal ultrasonography (IDUS) in predicting the extension of IPMN, and in selecting the method of pancreatic resection and the long-term outcome after surgery. Randomized prospective study. Forty consecutive patients who underwent IPMN resection were included in the study. Patients were randomly assigned to an IDUS group or control group, in which IDUS was not performed. Preoperative assessment by IDUS had an 85% (17 of 20) diagnostic accuracy for tumor extension of IPMN compared with 50% (10 of 20) in cases assessed by other imaging methods without IDUS (P=0.018). In 9 of 15 patients with invasive carcinoma, the tumor was located in the pancreatic head, and 11 had a main duct-type tumor. Recurrent disease was identified in 5 of 15 (33%) patients with invasive IPMN at a mean follow-up of 50 months; of them, 1 underwent preoperative IDUS and 4 were assessed by other imaging methods. None of the 25 patients with noninvasive IPMN had recurrent disease at follow-up. The overall cumulative 3-year survival rate was 79%. Preoperative IDUS was useful in determining the type of surgery and the extent of resection, especially in main-duct IPMN.
Portal Hypertensive Enteropathy Diagnosed by Capsule Endoscopy in Cirrhotic Patients: A Nationwide Multicenter Study
Background and Aim Due to the limited data on portal hypertensive enteropathy (PHE), the prevalence of and clinical factors related to PHE remain unclear. This study determined the prevalence of PHE using capsule endoscopy (CE) and PHE-related clinical factors. Methods This was a retrospective multicenter study using the Capsule Endoscopy Nationwide Database Registry. From 2,879 cases that underwent CE, 45 cirrhosis patients with portal hypertension (PH) were enrolled and divided into PHE ( n  = 18) and non-PHE ( n  = 27) groups. From computed tomography (CT) images, six secondary changes due to PH were scored to give a total CT score of 0–6. The main outcome variable was the prevalence of PHE and PHE-related clinical factors. Results The prevalence of PHE was 40 %. Comparing the PHE and non-PHE groups, the most common findings were angiodysplasias in 55.7 % (vs. 7.4 %, p  = 0.001) and varices in 38.9 % (vs. 0 %, p  = 0.001). Active bleeding was observed in 16.6 and 3.7 %, respectively, but this difference was not significant. In the univariate analysis, Child–Turcotte–Pugh class C ( p  = 0.002) and a high CT score (≥3 vs. <3, p  = 0.004) were significantly associated with PHE. However, only a high CT score was significant in the multivariate analysis (odds ratio 11.19; 95 % confidence interval, 1.59-infinity; p  = 0.040). Conclusions The prevalence of PHE was 40 %, and it might be more prevalent in cirrhosis patients with PH who have a high CT score. CE is a useful diagnostic tool for evaluating PHE in cirrhosis patients with PH.