Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
5
result(s) for
"Jouad, Kamal"
Sort by:
Clickable C-Glycosyl Scaffold for the Development of a Dual Fluorescent and 18Ffluorinated Cyanine-Containing Probe and Preliminary In Vitro/Vivo Evaluation by Fluorescence Imaging
by
Boura, Cédric
,
Kuhnast, Bertrand
,
Pierson, Julien
in
c(RGDfK)
,
C-glycosyl compounds
,
Chemical Sciences
2022
Considering the individual characteristics of positron emission tomography (PET) and optical imaging (OI) in terms of sensitivity, spatial resolution, and tissue penetration, the development of dual imaging agents for bimodal PET/OI imaging is a growing field. A current major breakthrough in this field is the design of monomolecular agent displaying both a radioisotope for PET and a fluorescent dye for OI. We took advantage of the multifunctionalities allowed by a clickable C-glycosyl scaffold to gather the different elements. We describe, for the first time, the synthesis of a cyanine-based dual PET/OI imaging probe based on a versatile synthetic strategy and its direct radiofluorination via [18F]F-C bond formation. The non-radioactive dual imaging probe coupled with two c(RGDfK) peptides was evaluated in vitro and in vivo in fluorescence imaging. The binding on αvβ3 integrin (IC50 = 16 nM) demonstrated the efficiency of the dimeric structure and PEG linkers in maintaining the affinity. In vivo fluorescence imaging of U-87 MG engrafted nude mice showed a high tumor uptake (40- and 100-fold increase for orthotopic and ectopic brain tumors, respectively, compared to healthy brain). In vitro and in vivo evaluations and resection of the ectopic tumor demonstrated the potential of the conjugate in glioblastoma cancer diagnosis and image-guided surgery.
Journal Article
Rapid assessment of target-binding fractions in molecular imaging agents using size-exclusion HPLC
2026
The clinical translation of molecularly targeted therapeutics and imaging agents represents a cornerstone of precision oncology, with the global theranostics market projected to exceed $25 billion by 2030. However, the development of theragnostic agents or diagnostic companions remains constrained by analytical bottlenecks in quality control, such as target-binding fraction, which are increasingly required by regulatory agencies as product release criteria during the translation process. Current methods, including enzyme-linked immunosorbent assay (ELISA), which require specialized resources or external CROs, or bead-based assays for radiolabeled compounds, which involve complex multi-step protocols; these limitations and others hamper their practical implementation in clinical manufacturing environments. Assay delays can postpone clinical trial initiation, increase development costs, and delay patient access to these agents.
We have developed and validated a rapid, size-exclusion high-performance liquid chromatography (SE-HPLC) method for the determination of target-binding fractions of labeled biologics. The method separates the unbound biologic from the larger antigen-bound complex, allowing for rapid quantification. We validated the method using a panel of fluorescently labeled antibodies (panitumumab-IRDye800CW, nivolumab-IRDye800CW) and radiolabeled biologics ([18F]GEH200521, [18F]NOTA-ABY-030), assessing linearity, specificity, and concentration independence. The SE-HPLC method achieved excellent separation of bound and unbound species with a resolution (Rs) of 3.2. A strong linear relationship (R
= 0.999) was observed between the antigen-to-antibody ratio and the measured binding fraction. The method demonstrated high specificity, with no binding detected with non-target antigens. The total assay and analysis time was less than 35 min, a significant improvement over traditional methods.
SE-HPLC provides a rapid, specific, and cost-effective alternative to traditional binding fraction assessment methods, reducing quality control timelines from weeks/hours to minutes. The method's compatibility with both fluorescent and radiolabeled biologics and integration with existing HPLC infrastructure represents a significant advancement in development workflows.
Journal Article
Clickable C-Glycosyl Scaffold for the Development of a Dual Fluorescent and 18Ffluorinated Cyanine-Containing Probe and Preliminary In Vitro/Vivo Evaluation by Fluorescence Imaging
2022
Considering the individual characteristics of positron emission tomography (PET) and optical imaging (OI) in terms of sensitivity, spatial resolution, and tissue penetration, the development of dual imaging agents for bimodal PET/OI imaging is a growing field. A current major breakthrough in this field is the design of monomolecular agent displaying both a radioisotope for PET and a fluorescent dye for OI. We took advantage of the multifunctionalities allowed by a clickable C-glycosyl scaffold to gather the different elements. We describe, for the first time, the synthesis of a cyanine-based dual PET/OI imaging probe based on a versatile synthetic strategy and its direct radiofluorination via [18F]F-C bond formation. The non-radioactive dual imaging probe coupled with two c(RGDfK) peptides was evaluated in vitro and in vivo in fluorescence imaging. The binding on αvβ3 integrin (IC50 = 16 nM) demonstrated the efficiency of the dimeric structure and PEG linkers in maintaining the affinity. In vivo fluorescence imaging of U-87 MG engrafted nude mice showed a high tumor uptake (40- and 100-fold increase for orthotopic and ectopic brain tumors, respectively, compared to healthy brain). In vitro and in vivo evaluations and resection of the ectopic tumor demonstrated the potential of the conjugate in glioblastoma cancer diagnosis and image-guided surgery.Considering the individual characteristics of positron emission tomography (PET) and optical imaging (OI) in terms of sensitivity, spatial resolution, and tissue penetration, the development of dual imaging agents for bimodal PET/OI imaging is a growing field. A current major breakthrough in this field is the design of monomolecular agent displaying both a radioisotope for PET and a fluorescent dye for OI. We took advantage of the multifunctionalities allowed by a clickable C-glycosyl scaffold to gather the different elements. We describe, for the first time, the synthesis of a cyanine-based dual PET/OI imaging probe based on a versatile synthetic strategy and its direct radiofluorination via [18F]F-C bond formation. The non-radioactive dual imaging probe coupled with two c(RGDfK) peptides was evaluated in vitro and in vivo in fluorescence imaging. The binding on αvβ3 integrin (IC50 = 16 nM) demonstrated the efficiency of the dimeric structure and PEG linkers in maintaining the affinity. In vivo fluorescence imaging of U-87 MG engrafted nude mice showed a high tumor uptake (40- and 100-fold increase for orthotopic and ectopic brain tumors, respectively, compared to healthy brain). In vitro and in vivo evaluations and resection of the ectopic tumor demonstrated the potential of the conjugate in glioblastoma cancer diagnosis and image-guided surgery.
Journal Article
Clickable IC/I-Glycosyl Scaffold for the Development of a Dual Fluorescent and sup.18Ffluorinated Cyanine-Containing Probe and Preliminary In Vitro/Vivo Evaluation by Fluorescence Imaging
by
Boura, Cédric
,
Kuhnast, Bertrand
,
Pierson, Julien
in
Analysis
,
Chemical properties
,
Evaluation
2022
Considering the individual characteristics of positron emission tomography (PET) and optical imaging (OI) in terms of sensitivity, spatial resolution, and tissue penetration, the development of dual imaging agents for bimodal PET/OI imaging is a growing field. A current major breakthrough in this field is the design of monomolecular agent displaying both a radioisotope for PET and a fluorescent dye for OI. We took advantage of the multifunctionalities allowed by a clickable C-glycosyl scaffold to gather the different elements. We describe, for the first time, the synthesis of a cyanine-based dual PET/OI imaging probe based on a versatile synthetic strategy and its direct radiofluorination via [[sup.18] F]F-C bond formation. The non-radioactive dual imaging probe coupled with two c(RGDfK) peptides was evaluated in vitro and in vivo in fluorescence imaging. The binding on α[sub.v] β[sub.3] integrin (IC[sub.50] = 16 nM) demonstrated the efficiency of the dimeric structure and PEG linkers in maintaining the affinity. In vivo fluorescence imaging of U-87 MG engrafted nude mice showed a high tumor uptake (40- and 100-fold increase for orthotopic and ectopic brain tumors, respectively, compared to healthy brain). In vitro and in vivo evaluations and resection of the ectopic tumor demonstrated the potential of the conjugate in glioblastoma cancer diagnosis and image-guided surgery.
Journal Article
Rapid Assessment of Target-Binding Fractions in Theranostic and Imaging Agents Using Size-Exclusion HPLC
by
Rosenberg, Adam J
,
Jouad, Kamal
,
McAdoo, Ashtyn
in
Antigens
,
Biological products
,
Biopharmaceuticals
2026
The clinical translation of molecularly targeted therapeutics and imaging agents represents a cornerstone of precision oncology, with the global theranostics market projected to exceed $25 billion by 2030. However, the development of theragnostic agents or diagnostic companions remains constrained by analytical bottlenecks in quality control, such as target-binding specificity, which are increasingly required by regulatory agencies as product release criteria during the translation process. Current methods, including enzyme-linked immunosorbent assay (ELISA), which require specialized resources or external CROs, or bead-based assays for radiolabeled compounds, which involve complex multi-step protocols; these limitations and others hamper their practical implementation in clinical manufacturing environments. Assay delays can postpone clinical trial initiation, increase development costs, and delay patient access to these agents.
We have developed and validated a rapid, size-exclusion high-performance liquid chromatography (SE-HPLC) method for the determination of target-binding fractions of labeled biologics. The method separates the unbound biologic from the larger antigen-bound complex, allowing for rapid quantification. We validated the method using a panel of fluorescently labeled antibodies (panitumumab-IRDye800CW, nivolumab-IRDye800CW) and radiolabeled biologics ([18F]GEH200521, [18F]NOTA-ABY-030), assessing linearity, specificity, and concentration independence. The SE-HPLC method achieved excellent separation of bound and unbound species with a resolution (Rs) of 3.2. A strong linear relationship (R
= 0.999) was observed between the antigen-to-antibody ratio and the measured binding fraction. The method demonstrated high specificity, with no binding detected with non-target antigens. The total assay and analysis time was less than 35 minutes, a significant improvement over traditional methods.
SE-HPLC provides a rapid, specific, and cost-effective alternative to traditional binding fraction assessment methods, reducing quality control timelines from weeks/hours to minutes. The method's compatibility with both fluorescent and radiolabeled biologics and integration with existing HPLC infrastructure represents a significant advancement in development workflows.
Journal Article