Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
63
result(s) for
"Kadone, Hideki"
Sort by:
A Waist-Mounted Interface for Mobile Viewpoint-Height Transformation Affecting Spatial Perception
2026
Visual information shapes spatial perception and body representation in human augmentation. However, the perceptual consequences of viewpoint-height changes produced by sensor–display geometry are not well understood. To address this gap, we developed an interface that maps a waist-mounted stereo fisheye camera to an eye-level viewpoint on a head-mounted display in real time. Geometric and timing calibration kept latency low enough to preserve a sense of agency and enable stable untethered walking. In a within-subject study comparing head- and waist-level viewpoints, participants approached adjustable gaps, rated passability confidence (1–7), and attempted passage when confident. We also recorded walking speed and assessed post-task body representation using a questionnaire. High gaps were judged passable and low gaps were not, irrespective of viewpoint. At the middle gap, confidence decreased with a head-level viewpoint and increased with a waist-level viewpoint, and walking speed decreased when a waist-level viewpoint was combined with a chest-height gap, consistent with added caution near the decision boundary. Body image reports most often indicated a lowered head position relative to the torso, consistent with visually driven rescaling rather than morphological change. These findings show that a waist-mounted interface for mobile viewpoint-height transformation can reliably shift spatial perception.
Journal Article
Passive Exoskeleton with Gait-Based Knee Joint Support for Individuals with Cerebral Palsy
by
Shimizu, Yukiyo
,
Suzuki, Kenji
,
Kennard, Maxwell
in
assistive devices
,
Biomechanical Phenomena
,
Care and treatment
2022
Cerebral palsy is a neurological disorder with a variety of symptoms that can affect muscle coordination and movement. Crouch gait is one such symptom that is defined as excessive knee flexion accompanied by a crouched posture. This paper introduces a passive exoskeleton to support the knee joint during stance of individuals with cerebral palsy that are affected by crouch gait. The exoskeleton utilizes a hydraulic disc brake mechanism that is actuated only by the body weight and gait of the wearer to provide a braking torque at the knee joint. This passive, gait-based control method aims to offer a compact, lightweight, and simple alternative to existing exoskeletons. Preliminary experiments were conducted to verify the mechanics, safety, and braking capabilities of the device with healthy participants. A pilot study with an individual with cerebral palsy was then conducted. The individual with cerebral palsy showed a reduction in hip joint angle when using the device (18.8∘ and 21.7∘ for left and right sides, respectively). The muscle co-activation index was also reduced from 0.48 to 0.24 on the right side and from 0.17 to 0.017 on the left side. However, changes such as activation timing and device training need to be improved to better support the user.
Journal Article
A Novel Bilateral Data Fusion Approach for EMG-Driven Deep Learning in Post-Stroke Paretic Gesture Recognition
by
Anastasiev, Alexey
,
Zaboronok, Alexander
,
Nishiyama, Hiroyuki
in
Aged
,
Analysis
,
Artificial intelligence
2025
We introduce a hybrid deep learning model for recognizing hand gestures from electromyography (EMG) signals in subacute stroke patients: the one-dimensional convolutional long short-term memory neural network (CNN-LSTM). The proposed network was trained, tested, and cross-validated on seven hand gesture movements, collected via EMG from 25 patients exhibiting clinical features of paresis. EMG data from these patients were collected twice post-stroke, at least one week apart, and divided into datasets A and B to assess performance over time while balancing subject-specific content and minimizing training bias. Dataset A had a median post-stroke time of 16.0 ± 8.6 days, while dataset B had a median of 19.2 ± 13.7 days. In classification tests based on the number of gesture classes (ranging from two to seven), the hybrid model achieved accuracies ranging from 85.66% to 82.27% in dataset A and from 88.36% to 81.69% in dataset B. To address the limitations of deep learning with small datasets, we developed a novel bilateral data fusion approach that incorporates EMG signals from the non-paretic limb during training. This approach significantly enhanced model performance across both datasets, as evidenced by improvements in sensitivity, specificity, accuracy, and F1-score metrics. The most substantial gains were observed in the three-gesture subset, where classification accuracy increased from 73.01% to 78.42% in dataset A, and from 77.95% to 85.69% in dataset B. In conclusion, although these results may be slightly lower than those of traditional supervised learning algorithms, the combination of bilateral data fusion and the absence of feature engineering offers a novel perspective for neurorehabilitation, where every data segment is critically significant.
Journal Article
Wearable Gait Measurement System with an Instrumented Cane for Exoskeleton Control
by
Hassan, Modar
,
Suzuki, Kenji
,
Sankai, Yoshiyuki
in
Biosensing Techniques - methods
,
cane
,
Control systems
2014
In this research we introduce a wearable sensory system for motion intention estimation and control of exoskeleton robot. The system comprises wearable inertial motion sensors and shoe-embedded force sensors. The system utilizes an instrumented cane as a part of the interface between the user and the robot. The cane reflects the motion of upper limbs, and is used in terms of human inter-limb synergies. The developed control system provides assisted motion in coherence with the motion of other unassisted limbs. The system utilizes the instrumented cane together with body worn sensors, and provides assistance for start, stop and continuous walking. We verified the function of the proposed method and the developed wearable system through gait trials on treadmill and on ground. The achievement contributes to finding an intuitive and feasible interface between human and robot through wearable gait sensors for practical use of assistive technology. It also contributes to the technology for cognitively assisted locomotion, which helps the locomotion of physically challenged people.
Journal Article
Automated EMG-Based Classification of Upper Extremity Motor Impairment Levels in Subacute Stroke
by
Anastasiev, Alexey
,
Zaboronok, Alexander
,
Nishiyama, Hiroyuki
in
Activities of daily living
,
Adult
,
Aged
2025
Rehabilitation of upper extremity (UE) impairments after stroke requires regular evaluation, with standard methods typically being time–consuming and relying heavily on manual assessment by therapists. In our study, we propose automating these assessments using electromyography (EMG) as a core indicator of muscle activity, correlating passive and active EMG signals with clinical motor impairment scores. UE motor function in 25 patients was evaluated using the Fugl–Meyer Assessment for UE (FMA–UE), the Modified Ashworth Scale (MAS), and the Brunnstrom Recovery Stages (BRS). EMG data were processed via feature extraction and linear discriminant analysis (LDA), with 10-fold cross–validation for binary classification based on clinical score thresholds. The LDA classifier accurately distinguished impairment categories, achieving area under the receiver operating characteristic curve (AUC–ROC) scores of 0.897 ± 0.272 for FMA–UE > 33, 0.981 ± 0.103 for FMA–UE > 44, 0.890 ± 0.262 for MAS > 0, 0.968 ± 0.130 for BRS > 3, and 0.987 ± 0.085 for BRS > 4. Notably, resting–state EMG alone yielded comparable classification performance. These findings demonstrate that EMG–driven assessments can reliably classify motor impairment levels, offering a pathway to objective clinical scoring that can streamline rehabilitation workflows, reduce therapists’ manual burden, and prioritize patient recovery over assessment procedures.
Journal Article
Supervised Myoelectrical Hand Gesture Recognition in Post-Acute Stroke Patients with Upper Limb Paresis on Affected and Non-Affected Sides
by
Anastasiev, Alexey
,
Zaboronok, Alexander
,
Marushima, Aiki
in
Activities of Daily Living
,
Aged
,
Algorithms
2022
In clinical practice, acute post-stroke paresis of the extremities fundamentally complicates timely rehabilitation of motor functions; however, recently, residual and distorted musculoskeletal signals have been used to initiate feedback-driven solutions for establishing motor rehabilitation. Here, we investigate the possibilities of basic hand gesture recognition in acute stroke patients with hand paresis using a novel, acute stroke, four-component multidomain feature set (ASF-4) with feature vector weight additions (ASF-14NP, ASF-24P) and supervised learning algorithms trained only by surface electromyography (sEMG). A total of 19 (65.9 ± 12.4 years old; 12 men, seven women) acute stroke survivors (12.4 ± 6.3 days since onset) with hand paresis (Brunnstrom stage 4 ± 1/4 ± 1, SIAS 3 ± 1/3 ± 2, FMA-UE 40 ± 20) performed 10 repetitive hand movements reflecting basic activities of daily living (ADLs): rest, fist, pinch, wrist flexion, wrist extension, finger spread, and thumb up. Signals were recorded using an eight-channel, portable sEMG device with electrode placement on the forearms and thenar areas of both limbs (four sensors on each extremity). Using data preprocessing, semi-automatic segmentation, and a set of extracted feature vectors, support vector machine (SVM), linear discriminant analysis (LDA), and k-nearest neighbors (k-NN) classifiers for statistical comparison and validity (paired t-tests, p-value < 0.05), we were able to discriminate myoelectrical patterns for each gesture on both paretic and non-paretic sides. Despite any post-stroke conditions, the evaluated total accuracy rate by the 10-fold cross-validation using SVM among four-, five-, six-, and seven-gesture models were 96.62%, 94.20%, 94.45%, and 95.57% for non-paretic and 90.37%, 88.48%, 88.60%, and 89.75% for paretic limbs, respectively. LDA had competitive results using PCA whereas k-NN was a less efficient classifier in gesture prediction. Thus, we demonstrate partial efficacy of the combination of sEMG and supervised learning for upper-limb rehabilitation procedures for early acute stroke motor recovery and various treatment applications.
Journal Article
The fatty degeneration of the lumbar erector spinae muscles affects dynamic spinal compensation ability during gait in adult spinal deformity
2021
This study aimed to investigate whether fat infiltration in lumbar paravertebral muscles assessed by magnetic resonance imaging (MRI) could be related to dynamic sagittal spino-pelvic balance during gait in adult spinal deformity (ASD). This is a retrospective analysis of 28 patients with ASD. The fat infiltration rate of lumbar erector spinae muscles, multifidus muscles and psoas major muscles was measured by T2 weighted axial MRI at L1-2 and L4-5. Dynamic sagittal spinal and pelvic angles during gait were evaluated using 3D motion analysis. The correlation between fat infiltration rate of those muscles with variations in dynamic kinematic variables while walking and static radiological parameters was analyzed. Spinal kyphosis and pelvic anteversion significantly increased during gait. Fat infiltration rate of erector spinae muscles at L1-2 was positively correlated with thoracic kyphosis (
r
= 0.392,
p
= 0.039) and pelvic tilt (
r
= 0.415,
p
= 0.028). Increase of spinal kyphosis during walking was positively correlated with fat infiltration rate of erector spinae muscles both at L1-2 (
r
= 0.394,
p
= 0.038) and L4-5 (
r
= 0.428,
p
= 0.023). Qualitative evaluation of lumbar erector spinae muscles assessed by fat infiltration rate has the potential to reflect dynamic spino-pelvic balance during gait.
Journal Article
Sock-Type Wearable Sensor for Estimating Lower Leg Muscle Activity Using Distal EMG Signals
2019
Lower leg muscle activity contributes to body control; thus, monitoring lower leg muscle activity is beneficial to understand the body condition and prevent accidents such as falls. Amplitude features such as the mean absolute values of electromyography (EMG) are used widely for monitoring muscle activity. Garment-type EMG measurement systems use electrodes and they enable us to monitor muscle activity in daily life without any specific knowledge and the installation for electrode placement. However, garment-type measurement systems require a high compression area around the electrodes to prevent electrode displacement. This makes it difficult for users to wear such measurement systems. A less restraining wearable system, wherein the electrodes are placed around the ankle, is realized for target muscles widely distributed around the shank. The signals obtained from around the ankle are propagated biosignals from several muscles, and are referred to as distal EMG signals. Our objective is to develop a sock-type wearable sensor for estimating lower leg muscle activity using distal EMG signals. We propose a signal processing method based on multiple bandpass filters from the perspectives of noise separation and feature augmentation. We conducted an experiment for designing the hardware configuration, and three other experiments for evaluating the estimation accuracy and dependability of muscle activity analysis. Compared to the baseline based on a 20-500 Hz bandpass filter, the results indicated that the proposed system estimates muscle activity with higher accuracy. Experimental results suggest that lower leg muscle activity can be estimated using distal EMG signals.
Journal Article
Lateral Symmetry of Synergies in Lower Limb Muscles of Acute Post-stroke Patients After Robotic Intervention
2018
Gait disturbance is commonly associated with stroke, which is a serious neurological disease. With current technology, various exoskeletons have been developed to provide therapy, leading to many studies evaluating the use of such exoskeletons as an intervention tool. Although these studies report improvements in patients who had undergone robotic intervention, they are usually reported with clinical assessment, which are unable to characterize how muscle activations change in patients after robotic intervention. We believe that muscle activations can provide an objective view on gait performance of patients. To quantify improvement of lateral symmetry before and after robotic intervention, muscle synergy analysis with Non-Negative Matrix Factorization was used to evaluate patients' EMG data. Eight stroke patients in their acute phase were evaluated before and after a course of robotic intervention with the Hybrid Assistive Limb (HAL), lasting over 3 weeks. We found a significant increase in similarity between lateral synergies of patients after robotic intervention. This is associated with significant improvements in gait measures like walking speed, step cadence, stance duration percentage of gait cycle. Clinical assessments [Functional Independence Measure-Locomotion (FIM-Locomotion), FIM-Motor (General), and Fugl-Meyer Assessment-Lower Extremity (FMA-LE)] showed significant improvements as well. Our study shows that muscle synergy analysis can be a good tool to quantify the change in neuromuscular coordination of lateral symmetry during walking in stroke patients.
Journal Article
Thoracic kyphosis and pelvic anteversion in patients with adult spinal deformity increase while walking: analyses of dynamic alignment change using a three-dimensional gait motion analysis system
2020
PurposeTo determine dynamic changes of spinopelvic alignment while walking using a three-dimensional (3D) gait motion analysis in adult spinal deformity (ASD) patients.MethodsThis study included 20 ASD patients. The 3D gait motion analysis (Vicon) was performed during continuous walking to their limit. Dynamic parameters were obtained using reflective markers on the spinous processes, which were segmented into thoracic (T-), lumbar (L-), and whole spine (S-), sagittal spinal distance (SVA) and coronal one (CVA), sagittal spinal angle to the vertical axis (SA) and coronal one (CA), sagittal pelvic angle to the horizontal axis (P-SA) and coronal (P-CA), and thoracic limited spinal angle to the pelvic angle (T-P SA) and lumbar one (L-P SA). The dynamic variables at the final lap were compared with those at the first lap of an oval walkway.ResultsSpinal kyphotic deformity deteriorated significantly. As for pelvic angle, the mean P-SA parameters (first lap/final lap) were 3.2°/5.2°. Anteversion of pelvic sagittal angle increased significantly after continuous walking to their limit. In particular, regarding limited spinal angle to the pelvic angle, the mean T-P SA parameters were 30.5°/36.2° and L-P SA parameters were 6.4°/6.8°. Thoracic kyphotic angle increased significantly, but lumbar kyphotic angle did not change.ConclusionDecrease of thoracic kyphosis and pelvic retroversion has been recognized as a compensation for ASD on standing radiograph. Our 3D gait motion analysis to determine spinal balance found thoracic kyphosis and pelvic anteversion increased significantly in patients with ASD after continuous walking to the limit of their endurance until they were fatigued, indicating a failure of compensation for ASD.Graphic abstractThese slides can be retrieved under Electronic Supplementary Material.
Journal Article