Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
604
result(s) for
"Kim, Min Gon"
Sort by:
Highly Sensitive Chemiluminescence-Based Lateral Flow Immunoassay for Cardiac Troponin I Detection in Human Serum
2020
Lateral flow assays (LFAs) have become the most common biosensing platforms for point-of-care testing due to their compliance with the ASSURED (affordable, sensitive, specific, user-friendly, rapid/robust, equipment-free, and deliverable to end-users) guidelines stipulated by the World Health Organization. However, the limited analytical sensitivity and low quantitative capability of conventional LFAs, which use gold nanoparticles (AuNPs) for colorimetric labeling, have prevented high-performance testing. Here, we report the development of a highly sensitive chemiluminescence (CL)-based LFA involving AuNPs conjugated with aldehyde-activated peroxidase and antibody molecules—i.e., AuNP-(ald)HRP-Ab—as a new conjugation scheme for high-performance testing in LFAs. When paired with the CL-based signal readout modality, the AuNP-(ald)HRP-Ab conjugate resulted in 110-fold enhanced sensitivity over the colorimetric response of a typical AuNP-Ab conjugate. To evaluate the performance of the CL-based LFA, we tested it with human cardiac troponin I (cTnI; a standard cardiac biomarker used to diagnose myocardial infarction) in standard and clinical serum samples. Testing the standard samples revealed a detection limit of 5.6 pg·mL−1 and acceptably reliable precision (with a coefficient of variation of 2.3%–8.4%), according to clinical guidelines. Moreover, testing the clinical samples revealed a high correlation (r = 0.97) with standard biochemical analyzers, demonstrating the potential clinical utility of the CL-based LFA for high-performance cTnI testing.
Journal Article
Advanced trap lateral flow immunoassay sensor for the detection of cortisol in human bodily fluids
2021
Paper-based biosensors based on lateral flow immunoassay (LFI) are promising candidates for POC diagnosis because of their ease of use and rapid target detection. However, the low sensitivity of LFI limits its application, and signal amplification has been used in numerous studies to increase its sensitivity. We developed an advanced trap LFI (
α
-trapLFI), a simple-to-use sensor, with an additional step for signal amplification. Here, signal amplification is automatically implemented following delayed release of enhancement solution induced by water-soluble polyvinyl alcohol tape. As the polyvinyl alcohol tape is exposed to water, its polymer structure is perturbed (within 5 min), allowing ions to pass through. This new sensor was designed to have a short time delay between the flow of solutions used for the immunoassay and signal amplification. The
α
-trapLFI was subsequently used to detect cortisol with high sensitivity (9.1 pg∙mL
−1
) over a broad detection range (0.01–1000 ng∙mL
−1
) in bodily fluids. Furthermore, an excellent correlation was obtained by analyzing 20 human real saliva samples using this sensor and a conventional ELISA (
R
2
= 0.90). The new sensor will be helpful in detecting various small molecules for simple, rapid, and portable POC diagnosis of stress disorders.
Journal Article
Multiple serum biomarkers for predicting suicidal behaviours in depressive patients receiving pharmacotherapy
2023
Predictive values of multiple serum biomarkers for suicidal behaviours (SBs) have rarely been tested. This study sought to evaluate and develop a panel of multiple serum biomarkers for predicting SBs in outpatients receiving a 12-month pharmacotherapy programme for depressive disorders.
At baseline, 14 serum biomarkers and socio-demographic/clinical characteristics including previous suicidal attempt and present suicidal severity were evaluated in 1094 patients with depressive disorders without a bipolar diagnosis. Of these, 884 were followed for increased suicidal severity and fatal/non-fatal suicide attempt outcomes over a 12-month treatment period. Individual and combined effects of serum biomarkers on these two prospective SBs were estimated using logistic regression analysis after adjustment for relevant covariates.
Increased suicidal severity and fatal/non-fatal suicide attempt during the 12-month pharmacotherapy were present in 155 (17.5%) and 38 (4.3%) participants, respectively. Combined cortisol, total cholesterol, and folate serum biomarkers predicted fatal/non-fatal suicide attempt, and these with interleukin-1 beta and homocysteine additionally predicted increased suicidal severity, with clear gradients robust to adjustment (p values < 0.001).
Application of multiple serum biomarkers could considerably improve the predictability of SBs during the outpatient treatment of depressive disorders, potentially highlighting the need for more frequent monitoring and risk appraisal.
Journal Article
Lateral flow immunoassay using plasmonic scattering
2025
The lateral flow immunoassay (LFIA) is one of the most successful sensing platforms for real-world point-of-care (POC) testing. However, achieving PCR-level sensitivity without compromising the inherent advantages of LFIA, such as rapid and robust operation, affordability, and naked-eye detection, has remained a primary challenge. In this study, a plasmonic scattering-utilising LFIA was proposed, created by transparentising a nitrocellulose membrane and placing a light-absorbing backing card under the membrane. This LFIA minimised the background signal from its matrix, leading to substantially enhanced sensitivity and enabling naked-eye detection of the plasmonic scattering signal from gold nanoparticles without optics. Our plasmonic scattering-utilising LFIA showed an approximately 2600–4400 times higher detection limit compared with that of commercial LFIAs in influenza A assays. In addition, it exhibited 90% sensitivity in clinical validation, approaching PCR-level sensitivity, while commercial LFIAs showed 23–30% sensitivity. The plasmonic scattering-utilising LFIA plays a ground-breaking role in POC diagnostics and significantly boosts follow-up research.
Lateral flow immunoassays (LFIA) are commonly used for point-of-care testing, but have limited sensitivity. Here, the authors present a LFIA based on plasmonic scattering and a light-absorbing background, resulting in significantly enhanced sensitivity.
Journal Article
Paper-Based Airborne Bacteria Collection and DNA Extraction Kit
2021
The critical risk from airborne infectious diseases, bio-weapons, and harmful bacteria is currently the highest it has ever been in human history. The requirement for monitoring airborne pathogens has gradually increased to defend against bioterrorism or prevent pandemics, especially via simple and low-cost platforms which can be applied in resource-limited settings. Here, we developed a paper-based airborne bacteria collection and DNA extraction kit suitable for simple application with minimal instruments. Airborne sample collection and DNA extraction for PCR analysis were integrated in the paper kit. We created an easy-to-use paper-based air monitoring system using 3D printing technology combined with an air pump. The operation time of the entire process, comprising air sampling, bacterial cell lysis, purification and concentration of DNA, and elution of the DNA analyte, was within 20 min. All the investigations and optimum settings were tested in a custom-designed closed cabinet system. In the fabricated cabinet system, the paper kit operated effectively at a temperature of 25–35 °C and 30–70% relative humidity for air containing 10–106 CFU Staphylococcus aureus. This paper kit could be applied for simple, rapid, and cost-effective airborne pathogen monitoring.
Journal Article
Label-Free Direct Detection of Saxitoxin Based on a Localized Surface Plasmon Resonance Aptasensor
2019
Seafood is an emerging health food, and interest in improving the quality of seafood is increasing. Saxitoxin (STX) is a neurotoxin produced by marine dinoflagellates that is accumulated in seafood. It can block the neuronal transmission between nerves and muscle cell membranes, resulting in the disturbance of neuromuscular transmission and subsequent voluntary muscle paralysis. Here, we developed a new aptamer for the detection of STX using graphene oxide–systematic evolution of ligands by exponential enrichment (GO-SELEX). Furthermore, we confirmed sensitivity and selectivity of the developed aptamer specific to STX using a localized surface plasmon resonance (LSPR) sensor. The sensing chip was fabricated by fixing the new STX aptamer immobilized on the gold nanorod (GNR) substrate. The STX LSPR aptasensor showed a broad, linear detection range from 5 to 10,000 μg/L, with a limit of detection (LOD) of 2.46 μg/L (3σ). Moreover, it was suitable for the detection of STX (10, 100, and 2000 μg/L) in spiked mussel samples and showed a good recovery rate (96.13–116.05%). The results demonstrated that the new STX aptamer-modified GNR chip was sufficiently sensitive and selective to detect STX and can be applied to real samples as well. This LSPR aptasensor is a simple, label-free, cost-effective sensing system with a wide detectable range.
Journal Article
Rapid and Simple Detection of Ochratoxin A using Fluorescence Resonance Energy Transfer on Lateral Flow Immunoassay (FRET-LFI)
2019
The detection of mycotoxins is crucial because of their toxicity in plants, animals, and humans. It is very important to determine whether food products are contaminated with mycotoxins such as ochratoxin A (OTA), as mycotoxins can survive heat treatments and hydrolysis. In this study, we designed a fluorescence resonance energy transfer (FRET)-based system that exploits antibody-antigen binding to detect mycotoxins more rapidly and easily than other currently available methods. In addition, we were able to effectively counteract the matrix effect in the sample by using a nitrocellulose membrane that enabled fluorescence measurement in coffee samples. The developed FRET on lateral flow immunoassay (FRET-LFI) system was used to detect OTA at a limit of detection (LOD) of 0.64 ng∙mL−1, and the test can be completed in only 30 min. Moreover, OTA in coffee samples was successfully detected at a LOD of 0.88 ng∙mL−1, overcoming the matrix effect, owing to the chromatographic properties of the capillary force of the membrane. We believe that the developed system can be used as a powerful tool for the sensitive diagnosis of harmful substances such as mycotoxins and pesticides for environmental and food quality control monitoring.
Journal Article
One-Step Detection of Vancomycin in Whole Blood Using the Lateral Flow Immunoassay
by
Jung, Yugyung
,
Lee, Young-Eun
,
Yang, Sung
in
Anti-Bacterial Agents - pharmacology
,
Antibiotics
,
Antibodies
2024
Vancomycin (VAN) is an effective antibiotic against Gram-positive bacteria and the first-line therapy to prevent and treat methicillin-resistant Staphylococcus aureus (MRSA) and severe infections. However, low concentrations of VAN can result in resistant strains. High doses of VAN can cause nephrotoxicity and ototoxicity; thus, VAN is a representative drug for which drug monitoring is recommended. Several methods have been proposed to detect VAN. Among them, lateral flow immunoassays (LFIAs) have advantages, such as simple and user-friendly operation, low sample volume requirement, and cost effectiveness. In this study, we developed an LFIA capable of rapid on-site detection such that the VAN concentration in plasma could be monitored within 20 min by a one-step detection process using whole blood without plasma separation. VAN can be detected in whole blood over a wide range of concentrations (20−10,000 ng/mL), and the LFIA reported here has a detection limit of 18 ng/mL. The applicability of the developed LFIA compared to the results of measuring VAN with a commercial enzyme-linked immunosorbent assay kit showed a satisfactory correlation (Spearman’s rho, ρ = 0.891). Therefore, the developed LFIA enables rapid and wide-range VAN detection in whole blood and can aid in drug monitoring to evaluate patients’ responses to treatment.
Journal Article
Aptamer-based selective KB cell killing by the photothermal effect of gold nanorods
2019
Development of both specific receptors against target cancer cells and therapeutic tools using receptor-functionalized nanoplatforms are important in cancer treatment. To address these challenges, we developed KB cell–specific aptamers using systematic evolution of ligands by exponential enrichment (SELEX). Additionally, we combined the targeting properties of aptamers and photothermal characteristics of GNRs. As a result, we generated efficient aptamer-gold nanorods (Apt-GNRs) targeting KB cancer cells and exhibiting photothermal therapeutic effects. When the samples were irradiated with a light-emitting diode at 845 nm, the targeted KB cells showed ~ 80% cell death compared with the unirradiated and aptamer-free control. Based on the low toxicity, biocompatibility, and selectivity of Apt-GNRs, the proposed nanoplatform has significant potential as a cancer therapy in vivo.
Journal Article
Wafer-Scale LSPR Substrate: Oblique Deposition of Gold on a Patterned Sapphire Substrate
2022
Label-free detection of biomolecules using localized surface plasmon resonance (LSPR) substrates is a highly attractive method for point-of-care (POC) testing. One of the remaining challenges to developing LSPR-based POC devices is to fabricate the LSPR substrates with large-scale, reproducible, and high-throughput. Herein, a fabrication strategy for wafer-scale LSPR substrates is demonstrated using reproducible, high-throughput techniques, such as nanoimprint lithography, wet-etching, and thin film deposition. A transparent sapphire wafer, on which SiO2-nanodot hard masks were formed via nanoimprint lithography, was anisotropically etched by a mixed solution of H2SO4 and H3PO4, resulting in a patterned sapphire substrate (PSS). An LSPR substrate was finally fabricated by oblique deposition of Au onto the PSS, which was then applied to label-free detection of the binding events of biomolecules. To the best of our knowledge, this paper is the first report on the application of the PSS used as an LSPR template by obliquely depositing a metal.
Journal Article