Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Reading LevelReading Level
-
Content TypeContent Type
-
YearFrom:-To:
-
More FiltersMore FiltersItem TypeIs Full-Text AvailableSubjectCountry Of PublicationPublisherSourceLanguagePlace of PublicationContributorsLocation
Done
Filters
Reset
49
result(s) for
"Kitchen, Steve"
Sort by:
The Effect of Dabigatran on Select Specialty Coagulation Assays
by
Kitchen, Steve
,
Gosselin, Robert
,
Adcock, Dorothy M.
in
Activated Protein C Resistance - blood
,
Administration, Oral
,
Antithrombins - pharmacology
2013
Dabigatran etexilate is a new oral anticoagulant that functions as a direct thrombin inhibitor. An inhibitor of thrombin has the potential to interfere with essentially all clot-based coagulation assays and select chromogenic assays, whereas the drug would not be expected to interfere in antigen-based assays. The purpose of this study was to evaluate the effect of dabigatran on various specialized coagulation assays using normal plasma specimens with varying concentrations of dabigatran (the active form of dabigatran etexilate). We have demonstrated that samples containing therapeutic levels of dabigatran may lead to underestimation of intrinsic factor activities with abnormal activated partial thromboplastin time (aPTT) mixing study results and a false-positive factor VIII Bethesda titer; overestimation of protein C and protein S activity and activated protein C resistance ratio when determined using aPTT-based methods; and overestimation of results based on chromogenic anti-IIa assays but no effect on antigen assays and select chromogenic assays.
Journal Article
Quality in Laboratory Hemostasis and Thrombosis
by
Kitchen, Steve
,
Rosendaal, Frits R
,
Olson, John D
in
Analysis
,
Blood
,
Blood coagulation disorders
2009
\"Over the last decades, major progress has been made in quality assurance of hemostatic laboratory assays. This book will be an indispensable part of every hemostasis laboratory, where, given its hands-on nature, it will rarely sit to get dusty on the shelves.\" -Frits R. Rosendaal, Leiden University Medical Center The hemostasis laboratory has a vital role in the diagnosis and management of patients with familial and acquired hemorrhagic and thrombotic disorders. Its role in the monitoring traditional anticoagulant therapy as well as therapy using new anticoagulants presents new challenges to the laboratory. Quality in Laboratory Hemostasis and Thrombosis not only addresses these important issues, but also covers international guidelines for testing, the development of international standard materials, management of hemostasis testing from the laboratory to the point of care as well as molecular genetic testing. Designed as a guide for all those working in hemostasis laboratories, this book details a quality program that, when put into place, will help to improve standards in testing. All of the authors are internationally recognised for their work in hemostasis and thrombosis. Using their experience, they provide information on standards, equipment and methods that will guide the development of a quality program to support all activities in the hemostasis laboratory.
Caution in Using the Activated Partial Thromboplastin Time to Monitor Argatroban in COVID-19 and Vaccine-Induced Immune Thrombocytopenia and Thrombosis (VITT)
by
Vanveen, Joost J
,
Kitchen, Steve
,
Saccullo, Giorgia
in
Aged
,
Anticoagulants
,
Arginine - analogs & derivatives
2021
Introduction
Argatroban is licensed for patients with heparin-induced thrombocytopenia and is conventionally monitored by activated partial thromboplastin time (APTT) ratio. The target range is 1.5 to 3.0 times the patients’ baseline APTT and not exceeding 100 s, however this baseline is not always known. APTT is known to plateau at higher levels of argatroban, and is influenced by coagulopathies, lupus anticoagulant and raised FVIII levels. It has been used as a treatment for COVID-19 and Vaccine-induced Immune Thrombocytopenia and Thrombosis (VITT). Some recent publications have favored the use of anti-IIa methods to determine the plasma drug concentration of argatroban.
Methods
Plasma of 60 samples from 3 COVID-19 patients and 54 samples from 5 VITT patients were tested by APTT ratio and anti-IIa method (dilute thrombin time dTT). Actin FS APTT ratios were derived from the baseline APTT of the patient and the mean normal APTT.
Results
Mean APTT ratio derived from baseline was 1.71 (COVID-19), 1.33 (VITT) compared to APTT ratio by mean normal 1.65 (COVID-19), 1.48 (VITT). dTT mean concentration was 0.64 µg/ml (COVID-19) 0.53 µg/ml (VITT) with poor correlations to COVID-19 baseline APTT ratio r2 = 0.1526 p <0.0001, mean normal r2 = 0.2188 p < 0.0001; VITT baseline APTT ratio r2 = 0.04 p < 0.001, VITT mean normal r2 = 0.0064 p < 0.001.
Conclusions
We believe that dTT is a superior method to monitor the concentration of argatroban, we have demonstrated significant differences between APTT ratios and dTT levels, which could have clinical impact. This is especially so in COVID-19 and VITT.
Journal Article
The natural history of glycogen storage disease type Ib in England: A multisite survey
by
Lewis, Katherine
,
Halligan, Rebecca
,
Kamarus Jaman, Nazreen
in
1,5‐anhydroglucitol‐6‐phosphate
,
Adults
,
Age groups
2021
Glycogen storage disease type Ib (GSDIb) is characterized by hepatomegaly and fasting hypoglycaemia as well as neutropaenia and recurrent infections. We conducted a retrospective observational study on a cohort of patients with GSDIb across England. A total of 35 patients, with a median age of 9.1 years (range 1‐39 years), were included in the study. We examined the genotype and phenotype of all patients and reported 14 novel alleles. The phenotype of GSDIb in England involves a short fasting tolerance that extends into adulthood and a high prevalence of gastrointestinal symptoms. Growth is difficult to manage and neutropaenia and recurrent infections persist throughout life. Liver transplantation was performed in nine patients, which normalized fasting tolerance but did not correct neutropaenia. This is the first natural history study on the cohort of GSDIb patients in England.
Journal Article
Quality in Laboratory Hemostasis and Thrombosis
by
Kitchen, Steve
,
Preston, F. Eric
,
Olson, John D
in
Blood
,
Blood coagulation disorders
,
Hemostasis
2013
The hemostasis laboratory has a vital role in the diagnosis and management of patients with familial and acquired hemorrhagic and thrombotic disorders.Rapid changes in the number and complexity of tests in this discipline have presented challenges for laboratories, as they develop quality programs for the oversight of this testing.
Development of national consensus statements on food labelling interpretation and protein allocation in a low phenylalanine diet for PKU
2019
Background
In the treatment of phenylketonuria (PKU), there was disparity between UK dietitians regarding interpretation of how different foods should be allocated in a low phenylalanine diet (allowed without measurement, not allowed, or allowed as part of phenylalanine exchanges). This led to variable advice being given to patients.
Methodology
In 2015, British Inherited Metabolic Disease Group (BIMDG) dietitians (
n
= 70) were sent a multiple-choice questionnaire on the interpretation of protein from food-labels and the allocation of different foods. Based on majority responses, 16 statements were developed. Over 18-months, using Delphi methodology, these statements were systematically reviewed and refined with a facilitator recording discussion until a clear majority was attained for each statement. In Phase 2 and 3 a further 7 statements were added.
Results
The statements incorporated controversial dietary topics including: a practical ‘scale’ for guiding calculation of protein from food-labels; a general definition for exchange-free foods; and guidance for specific foods. Responses were divided into paediatric and adult groups. Initially, there was majority consensus (≥86%) by paediatric dietitians (
n
= 29) for 14 of 16 statements; a further 2 structured discussions were required for 2 statements, with a final majority consensus of 72% (
n
= 26/36) and 64% (
n
= 16/25). In adult practice, 75% of dietitians agreed with all initial statements for adult patients and 40% advocated separate maternal-PKU guidelines. In Phase 2, 5 of 6 statements were agreed by ≥76% of respondents with one statement requiring a further round of discussion resulting in 2 agreed statements with a consensus of ≥71% by dietitians in both paediatric and adult practice. In Phase 3 one statement was added to elaborate further on an initial statement, and this received 94% acceptance by respondents. Statements were endorsed by the UK National Society for PKU.
Conclusions
The BIMDG dietitians group have developed consensus dietetic statements that aim to harmonise dietary advice given to patients with PKU across the UK, but monitoring of statement adherence by health professionals and patients is required.
Journal Article
Biomarkers for the diagnosis of venous thromboembolism: D-dimer, thrombin generation, procoagulant phospholipid and soluble P-selectin
2018
BackgroundThe diagnostic algorithm for venous thromboembolism (VTE) currently involves a composite of pre-test probability, D-dimer and imaging. Other laboratory tests, however, may assist in the identification of patients with VTE.AimTo assess the accuracy of different coagulation tests (D-dimer, thrombin generation, phospholipid-dependent (PPL) clotting time, soluble P-selectin (sP-selectin)) as biomarkers of acute VTE.MethodsRandom samples arriving at the Coagulation Laboratory at Mater Dei Hospital (Msida, Malta) from the Accident and Emergency Department with a request for D-dimer measurement were collected between August 2015 and February 2016. The following tests were performed: Innovance D-dimer (Siemens Healthcare Diagnostics), HemosIL D-dimer HS (Instrumentation Laboratory), thrombin generation (using the calibrated automated thrombogram), STA Procoag PPL (Diagnostica Stago) and sP-selectin (Affymetrix; eBioscience). VTE was objectively confirmed by compression ultrasonography, CT pulmonary angiography or ventilation/perfusion lung scan.Results100 samples were collected (33 with VTE). A strong positive linear correlation was found between the two D-dimer tests (r=0.97, p<0.001). Patients with VTE showed significantly higher sP-selectin concentrations compared with patients without VTE (75.7 ng/mL vs 53.0 ng/mL, p<0.001). In the random forest plot, the two D-dimer assays showed the highest variable importance, followed by sP-selectin. A sP-selectin cut-off of 74.8 ng/mL was associated with 72.7% sensitivity and 78.2% specificity for acute VTE in our cohort.ConclusionOur results confirmed D-dimer as the main biomarker of VTE and speculated a role for sP-selectin. The impact of thrombin generation was limited and no role emerged for the PPL clotting time. These observations need to be confirmed in large management studies.
Journal Article
Multicenter performance evaluation and reference range determination of a new one‐stage factor VIII assay
2022
Introduction We conducted a multicenter evaluation of a new one‐stage factor VIII (FVIII) assay (Roche Diagnostics), intended for the quantitative assessment of FVIII activity. We evaluated the analytical performance of the FVIII assay on the cobas t 711 analyzer. Methods Experiments performed at three laboratories used 3.2% citrated residual or commercially purchased plasma samples. Five human plasma pools and two controls were used to determine assay within‐run and within‐laboratory precision, and total reproducibility; coefficients of variation (CVs) and/or standard deviations (SDs) were calculated. Lot‐to‐lot variability and method comparison (vs Coagulation FVIII Deficient Plasma/Dade Actin FS Activated PTT reagent/Standard Human Plasma Calibrator on the Sysmex CS‐5100 analyzer; Siemens Healthineers) were evaluated by Passing–Bablok and Deming regression, respectively, and Pearson's r calculated. Assay‐specific reference range was determined using 199 fresh plasma samples from healthy adults, not receiving anticoagulants. Results Across sites, SDs for repeatability were 0.016–0.046 for samples with ≤1.0 international units (IU)/dL FVIII activity; CVs were 0.9%–3.8% for samples with >1.0 IU/dl activity. Among samples with mean FVIII activity 0.344–133 IU/dl, good intermediate precision (SD 0.020 for samples with 0.344 IU/dl activity; CV 1.8%–4.7%) and good total reproducibility (CV 2.0%–13.3%) were observed. The FVIII assay showed excellent lot‐to‐lot variability (Pearson's r = .999) and good correlation with the comparator assay (Pearson's r = .993–.996). The reference range for FVIII activity was 82.2−218.0 IU/dl. Conclusion The one‐stage FVIII assay demonstrated robust analytical performance on the cobas t 711 analyzer, supporting its use in routine laboratory practice. We conducted a multicenter evaluation of a new one‐stage factor VIII (FVIII) assay (Roche Diagnostics), intended for the quantitative assessment of FVIII activity. The new one‐stage FVIII assay demonstrated robust analytical performance on the cobas t 711 analyzer, supporting its use in routine laboratory practice.
Journal Article
Natural Protein Tolerance and Metabolic Control in Patients with Hereditary Tyrosinaemia Type 1
by
Pinto, Alex
,
Santra, Saikat
,
Mckiernan, Patrick
in
Adolescent
,
adults
,
Amino Acids, Neutral - administration & dosage
2020
In a longitudinal retrospective study, we aimed to assess natural protein (NP) tolerance and metabolic control in a cohort of 20 Hereditary Tyrosinaemia type I (HTI) patients. Their median age was 12 years ([3.2–17.7 years], n = 11 female, n = 8 Caucasian, n = 8 Asian origin, n = 2 Arabic and n = 2 Indian). All were on nitisinone (NTBC) with a median dose of 0.7 g/kg/day (range 0.4–1.5 g/kg/day) and were prescribed a tyrosine (Tyr)/phenylalanine (Phe)-restricted diet supplemented with Tyr/Phe-free L-amino acids. Data were collected on clinical signs at presentation, medical history, annual dietary prescriptions, and blood Phe and Tyr levels from diagnosis until transition to the adult service (aged 16–18 years) or liver transplantation (if it preceded transition). The median age of diagnosis was 2 months (range: 0 to 24 months), with n = 1 diagnosed by newborn screening, n = 3 following phenylketonuria (PKU) screening and n = 7 by sibling screening. Five patients were transplanted (median age 6.3 years), and one died due to liver cancer. The median follow-up was 10 years (3–16 years), and daily prescribed NP intake increased from a median of 5 to 24 g/day. Lifetime median blood Tyr (370 µmol/L, range 280–420 µmol/L) and Phe (50 µmol/L, 45–70 µmol/L) were maintained within the target recommended ranges. This cohort of HTI patients were able to increase the daily NP intake with age while maintaining good metabolic control. Extra NP may improve lifelong adherence to the diet.
Journal Article