Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
26 result(s) for "Knierim, Jan"
Sort by:
Routine Echocardiographic Assessment in LVAD Patients—A Structured Approach to Acquisition and Interpretation
Durable left ventricular assist devices (LVADs) are an established and highly effective therapy for patients with advanced heart failure. Ongoing technological improvements and structured follow-up programs have significantly enhanced device durability, reduced complications, and improved long-term survival. Consequently, a growing number of patients with LVAD support require long-term outpatient care and increasingly present to both specialized and non-specialized hospitals, including for admissions unrelated to heart failure. In this context, echocardiography plays a central role. It is essential not only for routine follow-up at dedicated LVAD clinics but also for the assessment of cardiac status during inpatient admissions for extracardiac conditions. However, echocardiographic evaluation in LVAD patients is technically demanding and requires a solid understanding of LVAD physiology, device–heart interactions, and the specific hemodynamic conditions of continuous-flow support. Without this knowledge, standard echocardiographic parameters may be misleading. This review provides sonographers and cardiologists with a practical, clinically oriented framework for routine transthoracic echocardiography in patients with durable LVAD support. We summarize key principles of LVAD hemodynamics, discuss interpretation of LVAD console parameters, propose a standardized imaging protocol, and outline a structured approach to common echocardiographic findings in routine ambulatory and inpatient settings.
Myocardial Work Assessment for the Prediction of Prognosis in Advanced Heart Failure
Objectives: The aim of this study was to investigate whether echocardiographic assessment of myocardial work is a predictor of outcome in advanced heart failure. Background: Global work index (GWI) and global constructive work (GCW) are calculated by means of speckle tracking, blood pressure measurement, and a normalized reference curve. Their prognostic value in advanced heart failure is unknown. Methods: Cardiopulmonary exercise testing and echocardiography with assessment of GWI and GCW was performed in patients with advanced heart failure caused by ischemic heart disease or dilated cardiomyopathy ( n = 105). They were then followed up repeatedly. The combined endpoint was all-cause death, implantation of a left ventricular assist device, or heart transplantation. Results: The median patient age was 54 years (interquartile range [IQR]: 48–59.9). The mean left ventricular ejection fraction was 27.8 ± 8.2%, the median NT-proBNP was 1,210 pg/ml (IQR: 435–3,696). The mean GWI was 603 ± 329 mmHg% and the mean GCW was 742 ± 363 mmHg%. The correlation between peak oxygen uptake and GWI as well as GCW was strongest in patients with ischemic cardiomyopathy ( r = 0.56, p = 0.001 and r = 0.53, p = 0.001, respectively). The median follow-up was 16 months (IQR: 12–18.5). Thirty one patients met the combined endpoint: Four patients died, eight underwent transplantation, and 19 underwent implantation of a left ventricular assist device. In the multivariate Cox regression analysis, only NYHA class, NT-proBNP and GWI (hazard ratio [HR] for every 50 mmHg%: 0.85; 95% CI: 0.77–0.94; p = 0.002) as well as GCW (HR for every 50 mmHg%: 0.86; 95% CI: 0.79–0.94; p = 0.001) were identified as independent predictors of the endpoint. The cut-off value for predicting the outcome was 455 mmHg% for GWI (AUC: 0.80; p < 0.0001; sensitivity 77.4%; specificity 71.6%) and 530 mmHg% for GCW (AUC: 0.80; p < 0.0001; sensitivity 74.2%; specificity 78.4%). Conclusions: GWI and GCW are powerful predictors of outcome in patients with advanced heart failure.
Left Ventricular Assist Device Implantation in Cancer-Therapy-Related Heart Failure
Objectives: Cancer-therapy-related heart failure (CTrHF) due to cardiotoxic drugs or radiation is a growing cause of end-stage heart failure. Limited knowledge is available concerning the use of continuous-flow left-ventricular-assist devices (cfLVAD) in this setting. Methods: The files of all 1334 patients who underwent cfLVAD implantation between December 2008 and December 2020 were screened for the cause of heart failure. All patients with CTrHF were included in the analysis. Results: A total of 32 patients with a median age of 58 years (IQR: 46–65) were included in the study; 15 (47%) were male. The median time from the first diagnosis of heart failure (HF) to cfLVAD implantation was 6 months (IQR 2–24), and from cancer treatment to cfLVAD implantation 40 months (IQR 5–144). Malignancies comprised non-Hodgkin lymphoma (n = 12, 37%), breast cancer (n = 9, 28%), sarcoma (n = 5, 16%), leukemia (n = 5, 16%), and others (n = 1, 3%). In 24 patients, chemotherapy included anthracyclines (others n = 2, unknown n = 6). Chest radiation was performed in 13 patients (39%). Moreover, 71% were classified as INTERMACS profile 1 or 2. The 30-day survival rate after LVAD implantation was 88%. Rethoracotomy was necessary in nine (29%), and a temporary right ventricular assist device in seven (21%) patients. The median survival was 29 months. There was no significant difference in survival or right HF between patients with CTrHF and a matched control group. Conclusions: CfLVAD implantation is feasible in high-risk patients with CTrHF with or without prior chest radiation.
Comparison of feasibility and results of frailty assessment methods prior to left ventricular assist device implantation
Aims Assessing frailty and sarcopenia is considered a valuable cornerstone of perioperative risk stratification in advanced heart failure patients. The lack of an international consensus on a diagnostic standard impedes its implementation in the clinical routine. This study aimed to compare the feasibility and prognostic impact of different assessment tools in patients undergoing continuous‐flow left ventricular assist device (cf‐LVAD) implantation. Methods and results We prospectively compared feasibility and prognostic values of six frailty/sarcopenia assessment methods in 94 patients prior to cf‐LVAD implantation: bioelectrical impedance analysis (BIA), computed tomography (CT)‐based measurement of two muscle areas/body surface area [erector spinae muscle (TMESA/BSA) and iliopsoas muscle (TPA/BSA)], physical performance tests [grip strength, 6 min walk test (6MWT)] and Rockwood Clinical Frailty Scale (RCFS). Six‐month mortality and/or prolonged ventilation time >95 h was defined as the primary endpoint. BIA and CT showed full feasibility (100%); physical performance and RCFS was limited due to patients' clinical status (feasibility: 87% grip strength, 62% 6MWT, 88% RCFS). Phase angle derived by BIA showed the best results regarding the prognostic value for 6 month mortality and/or prolonged ventilation time >95 h (odds ratio (OR) 0.66 [95% confidence interval (CI): 0.46–0.92], P = 0.019; area under the curve (AUC) 0.65). It provided incremental value to the clinical risk assessment of EuroSCORE II: C‐index of the combined model was 0.75 [95% CI; 0.651–0.848] compared with C‐index of EuroSCORE II alone, which was 0.73 (95% CI: 0.633–0.835). Six‐month survival was decreased in patients with reduced body cell mass derived by BIA or reduced muscle area in the CT scan compared with patients with normal values: body cell mass 65% (95% CI: 51.8–81.6%) vs. 83% (95% CI: 74.0–93.9%); P = 0.03, TMESA/BSA 65% (95% CI: 51.2–82.2%) vs. 82% (95% CI: 73.2–93.0%); P = 0.032 and TPA/BSA 66% (95% CI: 53.7–81.0%) vs. 85% (95% CI: 75.0–95.8%); P = 0.035. Conclusions Bioelectrical impedance analysis parameters and CT measurements were shown to be suitable to predict 6‐month mortality and/or prolonged ventilation time >95 h in patients with advanced heart failure prior to cf‐LVAD implantation. Phase angle had the best predictive capacity and sarcopenia diagnosed by reduced body cell mass in BIA or muscle area in CT was associated with a decreased 6 month survival.
Predictive Value of Two-Dimensional Speckle-Tracking Echocardiography in Patients Undergoing Surgical Ventricular Restoration
Parameters of left ventricular (LV) mechanics, obtained from speckle-tracking echocardiography (STE), were found to be of prognostic value in patients with heart failure and those who underwent cardiac surgery. This study aimed to assess the value of STE in patients scheduled to undergo surgical ventricular restoration (SVR). A total of 158 consecutive patients with baseline STE who underwent SVR due to an LV anteroapical aneurysm were included in the analysis. Preoperative longitudinal STE parameters were evaluated for their association with an outcome, defined as all-cause mortality, LV assist device implantation, or heart transplantation. The echocardiographic follow-up to assess the change in the regional function of the segments remote from the aneurysm was performed in 43 patients at a median of 10 months [interquartile range (IQR): 6-12.7 months] after SVR. During a median follow-up of 5.1 years (IQR: 1.6-8.7 years), events occurred in 68 patients (48%). Less impaired mean basal end-systolic longitudinal strain (BLS) with a cutoff value ≤ -10.1 % demonstrated a strong association with event-free survival, also in patients with an LV shape corresponding to an intermediate shape between aneurysmal and globally akinetic. Initially hypo- or akinetic basal segments with preoperative end-systolic strain ≤ -7.8% showed a greater improvement in wall motion at the short-term follow up. Patients with less impaired preoperative BLS exhibited a better event-free survival after SVR, also those with severe LV remodeling. The preserved preoperative segmental longitudinal strain was associated with a greater improvement in regional wall motion after SVR. BLS assessment may play a predictive role in patients with an LV anteroapical aneurysm who are scheduled to undergo SVR.
Diagnostic and Prognostic Value of a TDI-Derived Systolic Wall Motion Analysis as a Screening Modality for Allograft Rejection after Heart Transplantation
Background: Despite the risk for complications, allograft surveillance after orthotopic heart transplantation (OHT) is performed by cardiac catheterization and biopsies. We investigated the diagnostic and prognostic value of a TDI-derived systolic wall motion analysis of the posterobasal wall of the left ventricle (Sm) as a screening modality in OHT aftercare. Methods: We examined data of 210 eligible patients who underwent OHT between 2010 and 2020. Forty-four patients who had died within the initial hospital stay were excluded. For 166 patients, baseline and follow-up data were analyzed. The mean age at OHT was 46.2 (±11.4) years; 76.5% were male. Results: Within the observational period, 22 (13.3%) patients died. In total, 170 episodes of acute cellular or humoral rejections occurred (84 ISHLT1R; 13 ISHLT2R; 8 ISHLT3R; 65 AMR), and 29 catheterizations revealed cardiac allograft vasculopathy (5 CAV1; 4 CAV2; 20 CAV3). Individual Sm radial/longitudinal remained stable within the follow-up period (11.5 ± 2.2 cm/s; 10.9 ± 2.1 cm/s). Patients with acute rejections and CAV3 showed significant Sm radial/longitudinal reductions (AMR1: 1.6 ± 1.9 cm/s, confidence interval (CI) 0.77–0.243, p < 0.001; 1.8 ± 2.0 cm/s, CI 0.92–0.267, p < 0.001. ISHLT1R: 1.7 ± 1.8 cm/s, CI 1.32–2.08, p < 0.001; 2.0 ± 1.6 cm/s, CI 1.66–2.34, p < 0.001. CAV3: 1.3 ± 2.5 cm/s, CI 0.23–2.43, p < 0.017; 1.4 ± 2.8 cm/s, CI 0.21–2.66, p < 0.021). Lower Sm was associated with a threefold increase in all-cause mortality (hazard ratio (HR) 3.24, CI 1.2–8.76, p = 0.020; HR 2.92, CI 1.19–7.18, p = 0.019). Overall, Sm-triggered surveillance led to 0.75 invasive diagnostics per patient post-OHT year. Conclusions: Sm remained stable in the post-OHT course. Reductions indicated ISHLT1R, AMR1 and CAV3 and were associated with higher all-cause mortality. Sm-triggered surveillance may be referred to as a safe, high-yield screening modality in OHT aftercare.
Assessment of 10-Year Left-Ventricular-Remodeling by CMR in Patients Following Aortic Valve Replacement
Aims: Aortic valve replacement (AVR) may result in reverse cardiac remodeling. We aimed to assess long-term changes in the myocardium following AVR by Cardiac Magnetic Resonance Imaging (CMR). Methods: We prospectively observed the long-term left ventricular (LV) function and structure of 27 patients with AVR [ n = 19 with aortic stenosis (AS); n = 8 with aortic regurgitation (AR)] by CMR. Patients underwent CMR before, as well as 1, 5, and 10 years after AVR. We evaluated clinical parameters, LV volumes, mass, geometry, ejection fraction (EF), global myocardial longitudinal strain (MyoGLS), global myocardial circular strain (MyoGCS), hemodynamic forces (HemForces), and Late Gadolinium Enhancement (LGE). Results: The median of LVMI, EDVI, and ESVI decreased in both groups. Patients with AR had higher initial values of EDVI and ESVI and showed a more prominent initial reduction. In AS, MyoGLS improved already after 1 year and remained constant afterward, whereas, in AR no improvement of MyoGLS was found. MyoGCS remained unchanged in the AS group but deteriorated in the AR group over 10 years. Ejection fraction (EF) was higher in AS patients compared to AR 10 years post-AVR. Late gadolinium enhancement (LGE) could be found more frequently in AS patients. Conclusion: CMR was well suited to investigate myocardial changes over a 10-year follow up period in patients with aortic valve disease. Regarding the long-term functional changes following AVR, patients with AR seemed to benefit less from AVR compared to AS patients. Fibrosis was more common in AS, but this did not reflect functional evolution in these patients. Close monitoring seems indispensable to avoid irreversible structural damage of the heart and to perform AVR at an appropriate stage.
Impact of Muscle Mass as a Prognostic Factor for Failed Waiting Time Prior to Heart Transplantation
Objectives: Clinical deterioration during the waiting time impairs the prognosis of patients listed for heart transplantation. Reduced muscle mass increases the risk for mortality after cardiac surgery, but its impact on resilience against deterioration during the waiting time remains unclear. Methods: We retrospectively analyzed data from 93 patients without a VAD who were listed in Eurotransplant status “high urgent (HU)” for heart transplantation between January 2015 and October 2020. The axial muscle area of the erector spinae muscles at the level of thoracic vertebra 12 indexed to body surface area (TMESA/BSA) measured in the preoperative thoracic computed tomography scan was used to measure muscle mass. Results: Forty patients (43%) underwent emergency VAD implantation during the waiting time and four patients (4%) died during the waiting time. The risk of emergency VAD implantation/death during the waiting time decreased by 10% for every cm 2 /m 2 increase in muscle area [OR 0.901 (95% CI: 0.808–0.996); p = 0.049]. After adjusting for gender [OR 0.318 (95% CI: 0.087–1.073); p = 0.072], mean pulmonary artery pressure [OR 1.061 (95% CI: 0.999–1.131); p = 0.060], C-reactive protein [OR 1.352 (95% CI: 0.986–2.027); p = 0.096], and hemoglobin [OR 0.862 (95% CI: 0.618–1.177); p = 0.360], TMESA/BSA [OR 0.815 (95% CI: 0.698–0.936); p = 0.006] remained an independent risk factor for emergency VAD implantation/death during the HU waiting time. Conclusion: Muscle area of the erector spinae muscle appears to be a potential, easily identifiable risk factor for emergency VAD implantation or death in patients on the HU waiting list for heart transplantation. Identifying patients at risk could help optimize the outcome and the timing of VAD support.
Validity of the 6-Minute Walk Test in Patients with End-Stage Lung Diseases Wearing an Oronasal Surgical Mask in Times of the COVID-19 Pandemic
Background and Objectives: The 6-minute walk test (6MWT), as a clinical assessment tool for functional exercise capacity, is an integral component of lung allocation scores (LASs). In times of the coronavirus disease (COVID-19) pandemic, patients underwent 6MWTs wearing a surgical mask in ambulatory care. We investigated the impact of wearing a mask on 6-minute walk distances (6MWDs). Method: 6MWDs of 64 patients with end-stage lung diseases wearing an oronasal surgical mask were retrospectively compared to previously investigated 6MWDs of the same cohort, in a pre-COVID-19 pandemic era, without wearing a mask. Four patients were excluded due to a primary vascular disease, 29 patients due to clinically unstable pulmonary functions, and 1 patient due to a psychiatric disorder. Results: The median age of the patients included was 55 (46–58) years; 15 (48%) were male. Ten (32.2%) were on the Eurotransplant lung transplant waiting list with a median LAS of 34.3 (31.9–36.2). Twenty (64.5%) patients had chronic obstructive pulmonary diseases, 7 (22.6%) had interstitial lung diseases, and 4 (12.9%) had other end-stage lung diseases. The mean 6MWD without versus with wearing a mask was 306.9 (101.9) versus 305.7 (103.8) m, with a mean difference of −1.19 m (95% confidence interval −13.4 to 11.03). The observed difference is statistically equivalent to zero (p < 0.001). No significant differences in 6MWDs were observed between the clinical groups. Conclusion: Wearing an oronasal surgical mask did not affect the 6MWDs of patients with advanced lung diseases. Therefore, a masked 6MWT appears to provide a reliable examination of functional exercise capacity in this cohort.
Left ventricular diastolic function assessed by speckle tracking echocardiography in patients with left ventricular aneurysm
Speckle-tracking echocardiography (STE) parameters are an integral part of the assessment of left ventricular (LV) function. We aimed to evaluate established and novel STE parameters of LV diastolic function and their prognostic role in patients with LV anteroapical aneurysm undergoing surgical ventricular repair (SVR). We retrospectively examined the data of 137 patients with anteroapical LV aneurysm who underwent SVR. In 27 patients, the correlation of STE parameters with invasive hemodynamic parameters was evaluated. Preoperative echocardiographic parameters were assessed for their association with outcome, defined as all-cause mortality, LV assist device implantation, or heart transplantation. The late diastolic strain rate (GLSRa) showed a stronger correlation with mean pulmonary artery pressure (r =  − 0.75, p < 0.001) than all other parameters. GLSRa was also significantly correlated with mean pulmonary capillary wedge pressure and LV end-diastolic pressure. In the multivariate model, GLSRa and the ratio of early diastolic filling velocity to GLSRa demonstrated incremental prognostic value in addition to clinical and echocardiographic parameters. Patients with GLSRa < 0.59 s−1 had significantly shorter event-free survival than those with GLSRa > 0.59 s−1 (6.7 vs. 10.9 years, p < 0.001). Peak reservoir left atrial strain showed a weaker association with hemodynamic parameters and outcome compared to GLSRa. In patients with LV aneurysm, late diastolic strain rate and left atrial strain can be used for the assessment of LV diastolic function and have a predictive value for the outcome after surgical ventricular restoration.