Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
60 result(s) for "Konsei Shino"
Sort by:
Anatomic ACL reconstruction: rectangular tunnel/bone–patellar tendon–bone or triple-bundle/semitendinosus tendon grafting
Anatomic ACL reconstruction is the reasonable approach to restore stability without loss of motion after ACL tear. To mimic the normal ACL like a ribbon, our preferred procedures is the anatomic rectangular tunnel (ART) technique with a bone-patellar tendon-bone (BTB) graft or the anatomic triple bundle (ATB) procedure with a hamstring (HS) tendon graft. It is important to create tunnel apertures inside the attachment areas to lessen the tunnel widening. To identify the crescent-shaped ACL femoral attachment area, the upper cartilage margin, the posterior cartilage margin and the resident’s ridge are used as landmarks. To delineate the C-shaped tibial insertion, medial intercondylar ridge, Parson’s knob and anterior horn of the lateral meniscus are helpful. In ART-BTB procedure which is suitable for male patients engaged in contact sports, the parallelepiped tunnels with rectangular apertures are made within the femoral and tibial attachment areas. In ATBHS technique which is mainly applied to female athletes engaged in non-contact sports including skiing or basketball, 2 femoral and 3 tibial round tunnels are created inside the attachment areas. These techniques make it possible for the grafts to run as the native ACL without impingement to the notch or PCL. After femoral fixation with an interference screw or cortical fixation devices including Endobutton, the graft is pretensioned in situ by repetitive manual pulls at 15–20° of flexion, monitoring the graft tension with tensioners on a tensioning boot installed on the calf. Tibial fixation with pullout sutures is achieved using Double Spike Plate and a screw at the pre-determined amount of tension of 10–20N. While better outcomes with less failure rate are being obtained compared to those in the past, higher graft tear rate remains a problem. Improved preventive training may be required to avoid secondary ACL injuries.
Different effects of the lateral meniscus complete radial tear on the load distribution and transmission functions depending on the tear site
Purpose To compare the effect of the lateral meniscus (LM) complete radial tear at different tear sites on the load distribution and transmission functions. Methods A compressive load of 300 N was applied to the intact porcine knees ( n  = 30) at 15°, 30°, 60°, 90°, and 120° of flexion. The LM complete radial tears were created at the middle portion (group M), the posterior portion (group P), or the posterior root (group R) ( n  = 10, each group), and the same loading procedure was followed. Finally, the recorded three-dimensional paths were reproduced on the LM-removed knees. The peak contact pressure (contact area) in the lateral compartment and the calculated in situ force of the LM under the principle of superposition were compared among the four groups (intact, group M, group P, and group R). Results At all the flexion angles, the peak contact pressure (contact area) was significantly higher (lower) after creating the LM complete radial tear as compared to that in the intact state ( p  < 0.01). At 120° of flexion, group R represented the highest peak contact pressure (lowest contact area), followed by group P and group M ( p  < 0.05). The results of the in situ force carried by the LM were similar to those of the tibiofemoral contact mechanics. Conclusion The detrimental effect of the LM complete radial tear on the load distribution and transmission functions was greatest in the posterior root tear, followed by the posterior portion tear and the middle portion tear in the deep-flexed position. Complete radial tars of the meniscus, especially at the posterior root, should be repaired to restore the biomechanical function.
A longitudinal tear in the medial meniscal body decreased the in situ meniscus force under an axial load
Purpose To clarify the effect of longitudinal tears of the medial meniscus on the in situ meniscus force and the tibiofemoral relationship under axial load. Methods Twenty-one intact porcine knees were mounted on a 6-degrees of freedom robotic system, and the force and three-dimensional path of the knee joints were recorded during three cycles under a 250-N axial load at 30°, 60°, 90° and 120° of knee flexion. They were divided into three groups of seven knees with longitudinal tears in the middle to the posterior segment of the medial meniscus based on the tear site: rim, outer one-third and inner one-third of the meniscal body. After creating tears, the same tests were performed. Finally, all paths were reproduced after total medial meniscectomy, and the in situ force of the medial meniscus was calculated based on the principle of superposition. Results With a longitudinal tear, the in situ force of the medial meniscus was significantly decreased at 60°, 90° and 120° of knee flexion, regardless of the tear site. The decrement was greater with a tear in the meniscal body than a tear in the rim. A longitudinal tear in the meniscal body caused a significantly greater tibial varus rotation than a tear in the rim at all flexion angles. Conclusion Longitudinal tears significantly decreased the in situ force of the medial meniscus. Tears in the meniscal body caused a larger decrease of the in situ meniscus force and greater varus tibial rotation than tears in the rim.
Chronological changes in cross-sectional area of the bone-patellar tendon-bone autograft after anatomic rectangular tunnel ACL reconstruction
Purpose The purpose of this study was to evaluate the change in cross-sectional area (CSA) of bone-patellar tendon-bone (BTB) autografts up to 5 years after the anatomic rectangular tunnel (ART) anterior cruciate ligament reconstruction (ACLR). The changing pattern in CSA might be a potential indicator of the graft remodeling process. Methods Ninety-six (62 males, 34 females, mean age 27.0 years) patients were enrolled in this study with a total of 220 MRI scans after ART BTB ACLR to evaluate the CSA of the ACL autografts. The patients with first time unilateral ACLR that consented to undergo MRI evaluations at postoperative periods were included in this study. Intraoperatively, the CSA of the graft was measured directly using a custom-made area micrometer at the midpoint of the graft. Postoperatively, using an oblique axial slice MRI that was perpendicular to the long axis of the graft, the CSA of the graft was measured with digital radiology viewing program “SYNAPSE” at the midpoint of the graft. The postoperative MRI scans were classified into seven groups according to the period from ACLR to MRI evaluation: Group 0–2 months (m.), Group 3–6 m., Group 7–12 m., Group 1–2 years (y.), Group 2–3 y., Group 3–4 y., and Group 4 y.-. The percent increase of the CSA was calculated by dividing the postoperative CSA by the intraoperative CSA. Results The postoperative CSA was significantly larger than the intraoperative CSA in each group, with the exception of Group 0–2 m. The mean percent increase of the CSA in Group 0–2 m., 3–6 m., 7–12 m., 1–2 y., 2–3 y., 3–4 y., 4 y.- was 101.8 ± 18.2, 188.9 ± 27.4, 190.9 ± 43.7, 183.3 ± 28.9, 175.2 ± 27.9, 163.9 ± 19.8, 164.5 ± 25.4% respectively. The percent increase in Group 3–6 m., 7–12 m., 1–2 y., 2–3 y., 3–4 y., and 4 y.- was significantly greater than that in Group 0–2 m . Conclusions The CSA of the BTB autografts after the ART BTB ACLR increases rapidly by 3–6 months after ACLR, reached a maximum value of 190% at around 1 year, decreases gradually after that, and reaches a plateau at around 3 years. The current study might help clinicians to estimate an individual BTB autograft's remodeling stages when considering returning patients to sports. Level of evidence IV
The resident’s ridge as an arthroscopic landmark for anatomical femoral tunnel drilling in ACL reconstruction
The purposes of this study were to establish the technique to arthroscopically identify the resident’s ridge without bony notchplasty even in patients with chronic ACL insufficiency and to elucidate if the ridge could be used as a landmark for anatomical femoral tunnel for ACL graft. There were 50 consecutive patients undergoing arthroscopic ACL reconstruction. With the thigh kept horizontal using a leg holder, a meticulous effort was made to find out a linear ridge running proximo-distal in a posterior one-third of the lateral notch wall, after removal of superficial soft tissue with radiofrequency energy. If the ridge was found, a socket with a rectangular aperture of 5 × 10 mm was created just behind the ridge. At 3–4-weeks post surgery, three-dimensional computed tomography (3-D CT) was performed to geographically identify the location of the ridge using the socket as a reference. Arthroscopically, a linear ridge running from superior-anterior to inferior-posterior on the lateral notch wall was consistently observed 7–10 mm anterior to the posterior articular cartilage margin of the lateral femoral condyle in all of the patients. The 3-D CT pictures proved the arthroscopically identified ridge to be the resident’s ridge. The resident’s ridge is arthroscopically identifiable after non-mechanical removal of the soft tissues without bony notchplasty. The ridge is a useful landmark for anatomical femoral tunnel drilling in arthroscopic ACL reconstruction.
Effect of radial meniscal tear on in situ forces of meniscus and tibiofemoral relationship
Purpose To clarify the effect of the radial tear of the lateral meniscus on the in situ meniscus force and the tibiofemoral relationship under axial loads and valgus torques. Methods Ten intact porcine knees were settled to a 6-degree of freedom robotic system, while the force and 3-dimensional path of the knees were recorded via Universal Force Sensor (UFS) during 3 cycles of 250-N axial load and 5-Nm valgus torque at 15°, 30°, 45°, and 60° of knee flexion. The same examination was performed on the following 3 meniscal states sequentially; 33, 66, and 100% width of radial tears at the middle segment of the lateral meniscus, while recording the force and path of the knees via UFS. Finally, all paths were reproduced after total lateral meniscectomy and the in situ force of the lateral meniscus were calculated with the principle of superposition. Results The radial tear of 100% width significantly decreased the in situ force of the lateral meniscus and caused tibial medial shift and valgus rotation at 30°–60° of knee flexion in both testing protocols. Under a 250-N axial load at 60° of knee flexion, the in situ force decreased to 36 ± 29 N with 100% width of radial tear, which was 122 ± 38 N in the intact state. Additionally, the tibia shifted medially by 2.1 ± 0.9 mm and valgusrotated by 2.5 ± 1.9° with the complete radial tear. However, the radial tear of 33 or 66% width had little effect on either the in situ force or the tibial position. Conclusion A radial tear of 100% width involving the rim significantly decreased the in situ force of the lateral meniscus and caused medial shift and valgus rotation of the tibia, whereas a radial tear of up to 66% width produced only little change. The clinical relevance is that loss of meniscal functions due to complete radial tear can lead to abnormal stress concentration in a focal area of cartilage and can increase the risk of osteoarthritis in the future.
Morphological changes in femoral tunnels after anatomic anterior cruciate ligament reconstruction
Purpose Few studies investigated the enlargement inside the tunnel as well as the morphological change at the aperture after anterior cruciate ligament (ACL) reconstruction, whereas the tunnel enlargement has been well documented. The purposes were to evaluate the change in the cross-sectional area along the femoral tunnel and to morphologically clarify the enlargement at the femoral tunnel aperture after anatomic triple-bundle (ATB) ACL reconstruction. Methods The study included 15 patients with unilateral ACL rupture. ATB ACL reconstruction was performed using semitendinosus tendon autografts. Three-dimensional computer models of the femur and bone tunnels were reconstructed from computed tomography images obtained 3 weeks and 1 year postoperatively. The cross-sectional area at the aperture as well as inside the tunnel was compared between the two periods. Likewise, the location of tunnel walls and center in the tunnel footprint were evaluated. Results The cross-sectional area enlarged by 22.7 % for anteromedial/intermediate graft ( P  = 0.002) and 28.6 % for posterolateral graft ( P  = 0.002) at the aperture, while decreased by 36.2 % at 10 mm from the aperture for anteromedial/intermediate graft ( P  = 0.004). Both the anterior and posterior walls shifted anteriorly, while the distal wall shifted distally in both tunnels. Consequently, the center in the footprint significantly shifted anteriorly (4.9–6.6 %) and distally (2.2–2.6 %) in both tunnels. Conclusions The femoral tunnel enlargement occurred at the aperture after ATB ACL reconstruction, but did not occur in the middle of the femoral tunnel. The morphology at the aperture changed with time after surgery as the tunnel walls translated anteriorly and distally. Level of evidence Case series, Level IV.
Contact area between femoral tunnel and interference screw in anatomic rectangular tunnel ACL reconstruction: a comparison of outside-in and trans-portal inside-out techniques
Purpose The purpose of this study was to compare the femoral tunnel length, the femoral graft bending angle at the femoral tunnel aperture, and the contact area between the femoral tunnel wall and an interference screw used for fixation in anatomic rectangular tunnel anterior cruciate ligament (ACL) reconstruction (ART ACLR). Methods The study included 149 patients with primary ACL injury who underwent ART ACLR. Preoperatively, flexion angle of the index knee was checked under general anaesthesia. Those of less than 130° of passive flexion were assigned to the outside-in (OI) technique (78 patients), while the others to the trans-portal inside-out (TP) technique (71 patients). The patients underwent computed tomography with multiplanar reconstruction at 3–5 weeks post-operatively. Femoral tunnel length, graft bending angle, and contact ratio between the IFS and femoral tunnel were assessed. P  < 0.05 was considered statistically significant. Results The femoral tunnel length in the OI technique was significantly longer than that in the TP technique ( P  < 0.001). The femoral graft bending angle in the OI technique was significantly more acute than that in the TP technique ( P  < 0.001). The contact ratio in the OI technique was significantly larger than that in the TP technique at every point in the femoral tunnel ( P  < 0.001). Conclusions The OI technique resulted in a more acute femoral graft bending angle, longer mean femoral tunnel length, and larger contact ratio than the TP technique after ART ACLR. Level of evidence Retrospective comparative study, Level III.
Osteochondral Repair Using a Scaffold-Free Tissue-Engineered Construct Derived from Synovial Mesenchymal Stem Cells and a Hydroxyapatite-Based Artificial Bone
For an ideal osteochondral repair, it is important to facilitate zonal restoration of the subchondral bone and the cartilage, layer by layer. Specifically, restoration of the osteochondral junction and secure integration with adjacent cartilage could be considered key factors. The purpose of the present study was to investigate the feasibility of a combined material comprising a scaffold-free tissue-engineered construct (TEC) derived from synovial mesenchymal stem cells (MSCs) and a hydroxyapatite (HA) artificial bone using a rabbit osteochondral defect model. Osteochondral defects were created on the femoral groove of skeletally mature rabbits. The TEC and HA artificial bone were hybridized to develop a combined implant just before use, which was then implanted into defects (N=23). In the control group, HA alone was implanted (N=18). Histological evaluation and micro-indentation testing was performed for the evaluation of repair tissue. Normal knees were used as an additional control group for biomechanical testing (N=5). At hybridization, the TEC rapidly attached onto the surface of HA artificial bone block, which was implantable to osteochondral defects. Osteochondral defects treated with the combined implants exhibited more rapid subchondral bone repair coupled with the development of cartilaginous tissue with good tissue integration to the adjacent host cartilage when assessed at 6 months post implantation. Conversely, the control group exhibited delayed subchondral bone repair. In addition, the repair cartilaginous tissue in this group had poor integration to adjacent cartilage and contained clustered chondrocytes, suggesting an early osteoarthritis (OA)-like degenerative change at 6 months post implantation. Biomechanically, the osteochondral repair tissue treated with the combined implants at 6 months restored tissue stiffness, similar to normal osteochondral tissue. The combined implants significantly accelerated and improved osteochondral repair. Specifically, earlier restoration of subchondral bone, as well as good tissue integration of repair cartilage to adjacent host tissue could be clinically relevant in terms of the acceleration of postoperative rehabilitation and longer-term durability of repaired articular surface in patients with osteochondral lesions, including those with OA. In addition, the combined implant could be considered a promising MSC-based bio-implant with regard to safety and cost-effectiveness, considering that the TEC is a scaffold-free implant and HA artificial bone has been widely used in clinical practice.
A Biomechanical Comparison of 2 Over-the-Top Anterior Cruciate Ligament Reconstruction Techniques: A Cadaveric Study Using a Robotic Simulator
Background: For skeletally immature patients, over-the-top (OTT) anterior cruciate ligament (ACL) reconstruction (ACLR) is preferred. However, increased anterior laxity at deep knee flexion angles remains concerning. We modified the procedure to proximally shift the graft fixation site on the femur to prevent graft loosening at higher knee flexion angles and named it the supra-OTT procedure. Purpose: To compare anterior laxity and in situ forces of the ACL graft between conventional OTT and supra-OTT ACLR in a cadaveric model. Study Design: Controlled laboratory study. Methods: A total of 11 fresh-frozen cadaveric knee specimens underwent 4 robotic testing conditions: ACL intact, ACL resected, conventional OTT, and supra-OTT. For each condition, a 100-N load was applied at 0°, 15°, 30°, 60°, and 90° of knee flexion to simulate the Lachman test or anterior drawer test. In addition, a combined load of 5-N·m internal tibial torque and 10-N·m valgus torque was applied at 15° and 30° of knee flexion as a simulated pivot-shift test. Anterior tibial translation and in situ graft forces were recorded. The only difference between conventional OTT and supra-OTT ACLR was the graft fixation site on the femur. For conventional OTT ACLR, graft fixation was performed just on the proximal and lateral ends of the posterior condyle. For supra-OTT ACLR, the fixation point was around the proximal insertion of the lateral head of the gastrocnemius and the lateral edge of the posterior cortex, approximately 2 cm proximal to the conventional OTT position. Results: On the simulated anterior drawer test at 60° and 90° of knee flexion, anterior tibial translation after supra-OTT ACLR was significantly smaller than after conventional OTT ACLR (P < .01). However, no significant differences were noted at other flexion angles or on the simulated pivot-shift test between the conventional OTT and supra-OTT procedures. Some overconstraint and higher graft forces were noted with both techniques, but the supra-OTT technique caused even more overconstraint at higher flexion angles. Conclusion: Supra-OTT ACLR showed better biomechanical performance to control anterior laxity than conventional OTT ACLR at higher knee flexion angles. Clinical Relevance: The supra-OTT procedure may improve anterior stability at deep knee flexion angles.