Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
362 result(s) for "Lee, Jason K. W."
Sort by:
Digitally-embroidered liquid metal electronic textiles for wearable wireless systems
Electronic textiles capable of sensing, powering, and communication can be used to non-intrusively monitor human health during daily life. However, achieving these functionalities with clothing is challenging because of limitations in the electronic performance, flexibility and robustness of the underlying materials, which must endure repeated mechanical, thermal and chemical stresses during daily use. Here, we demonstrate electronic textile systems with functionalities in near-field powering and communication created by digital embroidery of liquid metal fibers. Owing to the unique electrical and mechanical properties of the liquid metal fibers, these electronic textiles can conform to body surfaces and establish robust wireless connectivity with nearby wearable or implantable devices, even during strenuous exercise. By transferring optimized electromagnetic patterns onto clothing in this way, we demonstrate a washable electronic shirt that can be wirelessly powered by a smartphone and continuously monitor axillary temperature without interfering with daily activities. Electronic textiles should maintain performance against repeated mechanical, thermal and chemical stresses during daily activities. Here, authors demonstrate digital embroidery of robust liquid metal-based fibres with wireless functionalities.
Wireless battery-free body sensor networks using near-field-enabled clothing
Networks of sensors placed on the skin can provide continuous measurement of human physiological signals for applications in clinical diagnostics, athletics and human-machine interfaces. Wireless and battery-free sensors are particularly desirable for reliable long-term monitoring, but current approaches for achieving this mode of operation rely on near-field technologies that require close proximity (at most a few centimetres) between each sensor and a wireless readout device. Here, we report near-field-enabled clothing capable of establishing wireless power and data connectivity between multiple distant points around the body to create a network of battery-free sensors interconnected by proximity to functional textile patterns. Using computer-controlled embroidery of conductive threads, we integrate clothing with near-field-responsive patterns that are completely fabric-based and free of fragile silicon components. We demonstrate the utility of the networked system for real-time, multi-node measurement of spinal posture as well as continuous sensing of temperature and gait during exercise. Though wireless near-field communication (NFC) technologies that connect wearable sensors for health monitoring have been reported, the short range of NFC readers limits sensor functionality. Here, the authors report a wireless and battery-free body sensor network with near-field-enabled clothing.
Delineating the impacts of air temperature and humidity for endurance exercise
New Findings What is the central question of this study? What are the independent effects of air temperature and humidity on performance, physiological and perceptual responses during endurance exercise? What is the main finding and its importance? When examined independently, elevated air temperature increased heat strain and impaired aerobic exercise performance, but to a lesser extent than has been reported previously. These findings highlight the importance of absolute humidity relative to temperature when exercising or working under severe heat stress. Many studies have reported that ambient heat stress increases physiological and perceptual strain and impairs endurance exercise, but effects of air temperature per se remain almost unexamined. Most studies have used matched relative humidity, thereby exponentially increasing absolute humidity (water content in air) concurrently with temperature. Absolute (not relative) humidity governs evaporative rate and is more important at higher work rates and air temperatures. Therefore, we examined the independent effects of air temperature and humidity on performance, thermal, cardiovascular and perceptual measures during endurance exercise. Utilizing a crossover design, 14 trained participants (7 females) completed 45 min fixed‐intensity cycling (70% V̇O2peak ${\\dot V_{{{\\rm{O}}_{\\rm{2}}}{\\rm{peak}}}$ ) followed by a 20‐km time trial in each of four environments: three air temperatures at matched absolute humidity (Cool, 18°C; Moderate, 27°C; and Hot, 36°C; at 1.96 kPa, air velocity ∼4.5 m/s), and one at elevated humidity (Hot Humid, 36°C at 3.92 kPa). Warmer air caused warmer skin (0.5°C/°C; P < 0.001), higher heart rate (1 bpm/°C; P < 0.001), sweat rate (0.04 l/h/°C; P < 0.001) and thermal perceptions during fixed‐intensity exercise, but minimally affected core temperature (<0.01°C/°C; P = 0.053). Time‐trial performance was comparable between Cool and Moderate (95% CI: –1.4, 5.9%; P = 0.263), but 3.6–6% slower in Hot (95% CI: ±2.4%; P ≤ 0.006). Elevated humidity increased core temperature (P < 0.001), perceived temperature and discomfort but not skin temperature or heart rate, and reduced mean blood pressure (P = 0.046) during fixed‐intensity exercise. Elevated humidity impaired time‐trial performance by 3.4% (95% CI: ±2.2%; P = 0.006). In conclusion, these findings quantify the importance of absolute humidity alongside air temperature when exercising under severe heat stress.
Neck cooling and cognitive performance following exercise-induced hyperthermia
Purpose To assess the efficacy of neck cooling on cognitive performance following exertional hyperthermia. Methods Twelve healthy men completed two experimental trials [control (CON) and neck cooling collar (NCC)] in a counter-balanced design. They ran on a treadmill at 70 % V O 2peak under warm and humid conditions (dry bulb temperature: 30.2 ± 0.3 °C, relative humidity: 71 ± 2 %) for 75 min or until volitional exhaustion. Gastrointestinal, neck and skin temperatures, heart rate and subjective ratings were assessed. Serum brain-derived neurotrophic factor (BDNF) levels were measured before and after each run. Cognitive performance comprising symbol digit matching, search and memory, digit span, choice reaction time and psychomotor vigilance test (PVT) were assessed before and after exercise. Results Mean gastrointestinal temperature was similar after exercise between trials (CON: 39.5 ± 0.4 °C vs. NCC: 39.6 ± 0.3 °C; p  = 0.15). Mean neck temperature was lowered in NCC compared to CON after the run (36.4 ± 1.6 °C vs. NCC: 26.0 ± 0.3 °C; p  < 0.001). Exercise-induced hyperthermia improved mean reaction time in the symbol digit matching test (−134 ± 154 ms; p  < 0.05) and the PVT (−18 ± 30 ms; p  < 0.05). Maximum span was increased in the digit span test (1 ± 2; p  < 0.05). Application of NCC reduced the number of search errors made in level 3 of the search and memory test ( p  < 0.05). Mean serum BDNF levels were increased following exercise-induced hyperthermia in both trials ( p  < 0.05). Conclusion Exercise-induced hyperthermia improves working memory and alertness. Neck cooling may only enhance performance in tasks of higher complexity.
Solar radiation and the validity of infrared tympanic temperature during exercise in the heat
We investigated the validity of infrared tympanic temperature (IR-Tty) during exercise in the heat with variations in solar radiation. Eight healthy males completed stationary cycling trials at 70% peak oxygen uptake until exhaustion in an environmental chamber maintained at 30°C with 50% relative humidity. Three solar radiation conditions, 0, 250 and 500 W/m2, were tested using a ceiling-mounted solar simulator (metal-halide lamps) over a 3 × 2 m irradiated area. IR-Tty and rectal temperature (Tre) were similar before and during exercise in each trial (P > 0.05). Spearman’s rank correlation coefficient (rs) demonstrated very strong (250 W/m2, rs = 0.87) and strong (0 W/m2, rs = 0.73; 500 W/m2, rs = 0.78) correlations between IR-Tty and Tre in all trials (P < 0.001). A Bland-Altman plot showed that mean differences (SD; 95% limits of agreement; root mean square error) between IR-Tty and Tre were − 0.11°C (0.46; − 1.00 to 0.78°C; 0.43 ± 0.16°C) in 0 W/m2, − 0.13°C (0.32; − 0.77 to 0.50°C; 0.32 ± 0.10°C) in 250 W/m2 and − 0.03°C (0.60; − 1.21 to 1.14°C; 0.46 ± 0.27°C) in 500 W/m2. A positive correlation was found in 500 W/m2 (rs = 0.51; P < 0.001) but not in 250 W/m2 (rs = 0.04; P = 0.762) and 0 W/m2 (rs = 0.04; P = 0.732), indicating a greater elevation in IR-Tty than Tre in 500 W/m2. Percentage of target attainment within ± 0.3°C between IR-Tty and Tre was higher in 250 W/m2 (100 ± 0%) than 0 (93 ± 7%) and 500 (90 ± 10%; P < 0.05) W/m2. IR-Tty is acceptable for core temperature monitoring during exercise in the heat when solar radiation is ≤ 500 W/m2, and its accuracy increases when solar radiation is 250 W/m2 under our study conditions.
Endocrine effects of heat exposure and relevance to climate change
Climate change is increasing both seasonal temperatures and the frequency and severity of heat extremes. As the endocrine system facilitates physiological adaptations to temperature changes, diseases with an endocrinological basis have the potential to affect thermoregulation and increase the risk of heat injury. The effect of climate change and associated high temperature exposure on endocrine axis development and function, and on the prevalence and severity of diseases associated with hormone deficiency or excess, is unclear. This Perspective summarizes current knowledge relating to the hormonal effects of heat exposure in species ranging from rodents to humans. We also describe the potential effect of high temperature exposures on patients with endocrine diseases. Finally, we highlight the need for more basic science, clinical and epidemiological research into the effects of heat on endocrine function and health; this research could enable the development of interventions for people most at risk, in the context of rising environmental temperatures. Climate change is causing human populations to be exposed to increasingly higher ambient temperatures and more frequent and extreme heatwaves than previously observed. This Perspective considers the available evidence on the endocrine effects of heat exposure, and maps out a path for future research into this field.
Project Coolbit: can your watch predict heat stress and thermal comfort sensation?
Global climate is changing as a result of anthropogenic warming, leading to higher daily excursions of temperature in cities. Such elevated temperatures have great implications on human thermal comfort and heat stress, which should be closely monitored. Current methods for heat exposure assessments (surveys, microclimate measurements, and laboratory experiments), however, present several limitations: measurements are scattered in time and space and data gathered on outdoor thermal stress and comfort often does not include physiological and behavioral parameters. To address these shortcomings, Project Coolbit aims to introduce a human-centric approach to thermal comfort assessments. In this study, we propose and evaluate the use of wrist-mounted wearable devices to monitor environmental and physiological responses that span a wide range of spatial and temporal distributions. We introduce an integrated wearable weather station that records (a) microclimate parameters (such as air temperature and humidity), (b) physiological parameters (heart rate, skin temperature and humidity), and (c) subjective feedback. The feasibility of this methodology to assess thermal comfort and heat stress is then evaluated using two sets of experiments: controlled-environment physiological data collection, and outdoor environmental data collection. We find that using the data obtained through the wrist-mounted wearables, core temperature can be predicted non-invasively with 95 percent of target attainment within ±0.27 °C. Additionally, a direct connection between the air temperature at the wrist ( T a , w ) and the perceived activity level (PAV) of individuals was drawn. We observe that with increased T a , w , the desire for physical activity is significantly reduced, reaching ‘Transition only’ PAV level at 36 °C. These assessments reveal that the wearable methodology provides a comprehensive and accurate representation of human heat exposure, which can be extended in real-time to cover a large spatial distribution in a given city and quantify the impact of heat exposure on human life.
Thermoregulation, pacing and fluid balance during mass participation distance running in a warm and humid environment
Deep body temperature ( T c ), pacing strategy and fluid balance were investigated during a 21-km road race in a warm and humid environment. Thirty-one males (age 25.3 ± 3.2 years; maximal oxygen uptake 59.1 ± 4.2 ml kg −1  min −1 ) volunteered for this study. Continuous T c responses were obtained in 25 runners. Research stations at approximately 3-km intervals permitted accurate assessment of split times and fluid intake. Environmental conditions averaged 26.4°C dry bulb temperature and 81% relative humidity. Peak T c was 39.8 ± 0.5 (38.5–40.7) °C with 24 runners achieving T c  > 39.0°C, 17 runners ≥39.5°C, and 10 runners ≥40.0°C. In 12 runners attaining peak T c  ≥ 39.8°C, running speed did not differ significantly when T c was below or above this threshold (208 ± 15 cf. 205 ± 24 m min −1 ; P  = 0.532). Running velocity was the main significant predictor variable of ∆ T c at 21 km ( R 2  = 0.42, P  < 0.001) and was the main discriminating variable between hyperthermic ( T c  ≥ 39.8°C) and normothermic runners ( T c  < 39.8°C) up to 11.8 km. A reverse J-shaped pacing profile characterised by a marked reduction in running speed after 6.9 km and evidence of an end-spurt in 16 runners was observed. Variables relating to fluid balance were not associated with any T c parameters or pacing. We conclude that hyperthermia, defined by a deep body temperature greater than 39.5°C, is common in trained individuals undertaking outdoor distance running in environmental heat, without evidence of fatigue or heat illness.
Personal assessment of urban heat exposure: a systematic review
To fully address the multi-faceted challenges of urban heat, it is paramount that humans are placed at the center of the agenda. This is manifested in a recent shift in urban heat studies that aim to achieve a ‘human-centric’ approach, i.e. focusing on personalized characteristics of comfort, well-being, performance, and health, as opposed to the one-size-fits-all solutions and guidelines. The proposed article is focused on systematically reviewing personalized urban heat studies and detailing the objectives posed, methodologies utilized, and limitations yet to be addressed. We further summarize current knowledge and challenges in addressing the impact of personal heat exposure on human life by discussing the literature linked with urban heat studies at the human, building, and city scales. Lastly, this systematic review reveals the need for future evaluations focused on accuracy and standardization of human-centric data collection and analytics, and more importantly, addressing critical geographic and socio-economic knowledge gaps identified in the field.
The use of sun-shade on safe heat exposure limit on a sunny summer day: a modelling study in Japan
Abstract Sustainable methods are required to reduce the risks of thermal strain and heat-related illness without exacerbating greenhouse gas emissions. We investigated the effects of sun-shade use on safe heat exposure limit on a sunny summer day using historical climate data in Japan. We simulated a heat-acclimatised person standing at rest (metabolic heat production, 70 W·m−2) and during light work (100 W·m−2) on an asphalt pavement in the sun and sun-shade. Japan has three Köppen climate regions: tropical, temperate and cold. We analysed one city in the tropical region (24°N), three cities in the temperate region (31°N, 35°N and 39°N) and one city in the cold region (40°N). Hourly data were collected from 7 AM to 6 PM, June to September, from 2010 to 2019. The day with the longest daylight hours and the greatest solar radiation intensity was used for analysis. With sun-shade (a white polyester tarpaulin/awning), ambient temperature, global solar radiation and ground surface temperature were assumed to be 0.5°C, 45% and 6°C lower than in the sun, respectively. Sun-shade use eliminated the days with at least 1 hour exceeding safe heat exposure limit at rest in all cities. The same was observed for light work in the temperate and cold cities, although the tropical city had 2 days exceeding safe heat exposure limit during the decade. Sun-shade use on a sunny summer day can be an effective and sustainable method to reduce heat exposure hazard at rest and during light work in tropical, temperate and cold climate regions.