Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
25 result(s) for "Li, Fankang"
Sort by:
Data Correction of Intensity Modulated Small Angle Scattering
To investigate long length scale structures using neutron scattering, real space techniques have shown certain advantages over the conventional methods working in reciprocal space. As one of the real space measurement techniques, spin echo modulated small angle neutron scattering (SEMSANS) has attracted attention, due to its relaxed constraints on sample environment and the possibility to combine SEMSANS and a conventional small angle neutron scattering instrument. In this report, we present the first implementation of SEMSANS at a pulsed neutron source and discuss important corrections to the data due to the sample absorption. These corrections allow measurements made with different neutron wavelengths and SEMSANS configurations to be overlaid and give confidence that the measurements provide an accurate representation of the density correlations in the sample.
Poplar: A polarized neutron development beamline for polarization analysis and Larmor labeling techniques
A thermal neutron development beamline equipped with a Si monochromator has been commissioned at the HB-2D beam port of the High Flux Isotope Reactor at Oak Ridge National Laboratory. This instrument is dedicated to the development of neutron scattering methods and instrumentation, serving as a complement to the cold neutron development beamline CG-4B at the cold guide hall. Two incident wavelengths are available, 2.43 and 1.72 Å, with a flux of 1.75 and 1.28  ×105  n/(cm2 s), respectively. The instrument can be operated either in high-resolution or high-intensity mode through the horizontal bending of the monochromator. As the bending increases, the incident flux on the sample increases as a result of the additional lattice strain induced in the silicon wafers. With its mission centered on advancing neutron scattering instrumentation, the beamline has been named POPLAR, an acronym for polarized neutron development beamline for polarization analysis and Larmor labeling techniques.
High resolution neutron Larmor diffraction using superconducting magnetic Wollaston prisms
The neutron Larmor diffraction technique has been implemented using superconducting magnetic Wollaston prisms in both single-arm and double-arm configurations. Successful measurements of the coefficient of thermal expansion of a single-crystal copper sample demonstrates that the method works as expected. The experiment involves a new method of tuning by varying the magnetic field configurations in the device and the tuning results agree well with previous measurements. The difference between single-arm and double-arm configurations has been investigated experimentally. We conclude that this measurement benchmarks the applications of magnetic Wollaston prisms in Larmor diffraction and shows in principle that the setup can be used for inelastic phonon line-width measurements. The achievable resolution for Larmor diffraction is comparable to that using Neutron Resonance Spin Echo (NRSE) coils. The use of superconducting materials in the prisms allows high neutron polarization and transmission efficiency to be achieved.
Modern Trends in Neutron Scattering Instrument Technologies
This article reviews some current trends that can be observed in the development of neutron scattering instrument technologies. While the number of neutron scattering facilities worldwide and the number of beam days they offer are largely stable, their scientific impact is increasing through improving instrumental capabilities, new and more versatile instruments, and more efficient data collection protocols. Neutron beams are becoming smaller but more intense, and instruments are being designed to utilize more ‘useful’ neutrons in unit time. This article picks and discusses a few recent developments in the areas of integrated source and instrument design, use of computational tools, new detectors, and experiment automation.
A portable primary radar for general aviation
A detailed situation awareness of the local environment is essential for safe flight in General Aviation. When operating under Visual Flight Rules, eyesight is crucial for maintaining situation awareness and objects may be overlooked. Technical solutions such as Flarm have been sought, but they only work on a basis of co-operation: obstacles without the proper equipment are invisible. Recent developments in the field of radar technology, partly empowered by the demand for sensors for autonomous cars, have improved the size and power consumption of available hardware. Today, the hardware exists to build a portable primary radar system for situation awareness. In this paper the results are presented of efforts to build the first portable primary radar for general, which has to be lightweight, cheap and have a low power consumption. The focus in this paper is on the software design of such a radar system. The physical principles of radar sensing are described, as well as the scientific steps needed to provide situation awareness. The hardware and software for the radar are both built and tested, and the results of these tests are presented. A flight experiment is performed with a small aircraft flying past a stationary radar on a small hill. It is found that the radar is capable of detecting the aircraft up to a distance of at least 3 kilometers. 3D localization is performed and the location determined by the radar was on average 46 meters away from the aircraft position as measured by satellite navigation, relative to a total distance of about 1000 meters from the radar. A low-pass filter can be applied on the raw results in order to improve the location estimation further. Future research will focus on bringing the portable radar in motion while operating.
Conceptual Polarization Setup at CENTAUR, the SANS/WANS Instrument at the Second Target Station of SNS
CENTAUR is a multifunctional general purpose small-angle and wide-angle neutron scattering instrument with diffraction and spectroscopic capability in the future Second Target Station at the Spallation Neutron Source of the Oak Ridge National Laboratory. To fill a gap in neutron polarization capability, the instrument will be designed to provide polarization analysis. Here we present the conceptual polarization setup at CENTAUR, as well as the Spin Echo Modulated Small-Angle Neutron Scattering setup which will further expand the length scale covered by the instrument.
Thermal conductivity of cryoprotective agents loaded with nanoparticles, with application to recovery of preserved tissues and organs from cryogenic storage
The objective of this study is to provide thermal conductivity data for CPA-based nanofluids for the benefit of the analyses of cryopreservation by vitrification. Thermal conductivity measurements were conducted using a hot-wire technique on an experimentation platform of the cryomacroscope, to correlate measurements with observed physical effects such as crystallization and fracturing. Tested materials in this study include the CPA cocktails M22, VS55, DP6, and DP6+sucrose. Nanofluids in this study include the above CPA cocktails as base solutions, when mixed with either iron-oxide nanoparticles (IONP) or silica-coated iron-oxide nanoparticles (sIONP). Results of this study demonstrated the addition of sIONP to any of the CPA cocktails tested did not significantly affect its thermal conductivity, its tendency to vitrify or, conversely, its tendency to form rewarming phase crystallization (RPC). Fractures were observed with cryomacroscopy at the onset of rewarming for DP6+sIONP under carefully controlled rewarming conditions without RF activation, despite the inherent opacity of the sIONP solutions. It is likely that using RF heating in order to accelerate rewarming while unifying the temperature distribution would prevent fracture and RPC. However, sIONP were not activated in this study, as the RF heating mechanism would interfere with thermal conductivity measurements. The addition of IONP to DP6 appears to hinder the tendency of the CPA to vitrify, which is a detrimental effect. But it is unlikely that uncoated nanoparticle solutions will be used in practical applications.
Data Correction of Intensity Modulated Small Angle Scattering
Abstract To investigate long length scale structures using neutron scattering, real space techniques have shown certain advantages over the conventional methods working in reciprocal space. As one of the real space measurement techniques, spin echo modulated small angle neutron scattering (SEMSANS) has attracted attention, due to its relaxed constraints on sample environment and the possibility to combine SEMSANS and a conventional small angle neutron scattering instrument. In this report, we present the first implementation of SEMSANS at a pulsed neutron source and discuss important corrections to the data due to the sample absorption. These corrections allow measurements made with different neutron wavelengths and SEMSANS configurations to be overlaid and give confidence that the measurements provide an accurate representation of the density correlations in the sample.
Analytical volume model for optimized spatial radar bat detection in onshore wind parks
To develop mitigation measures for the protection of bats in close proximity to onshore wind turbines, new detection techniques covering large-scale environments and techniques, which are able to track individuals are required. Radar based observations, successfully applied in ornithological studies, offer a promising potential, but come with challenges regarding the comparability of measurements and noise interference (ground clutter) from objects within detection range. This paper presents improvements of a commercially available inexpensive pulse radar for 3D spatial detection of bat-sized objects in onshore wind parks. A new analytical spatial detection volume model is presented incorporating calibrated radar data and landscape parameters such as clutter. Computer simulation programs to process the analytical spatial detection volume model were developed. For model calibration, the minimum signal power of the radar was experimentally determined with the radar cross section (RCS) of an artificial bat (similar to Nyctalus noctula), resulting in a maximum detection range of 800 m and a corresponding RCS of 12.7 cm². Additionally, the spatial volume for radar detection was optimized with a clutter shielding fence (CSF). Adjusting the volume model by incorporating a theoretical model of the CSF, an extension of the detection volume by a factor of 2.5 was achieved, while the total volume of a 105° horizontal angular radar image section yields 0.0105 km³. Extrapolation and comparison with state-of-the-art acoustic bat detection result in a 270 times larger volume, confirming the large-scale detection capabilities of the pulse radar.
Larmor labeling of neutron spin using superconducting Wollaston prisms
Neutron spin Larmor labeling using magnetic Wollaston prisms (WP) provides a way to overcome some of the limitations arising from the nature of neutron beams: low flux and divergence. Using superconducting films and tapes, a series of strong, well-defined shaped magnetic fields can be produced due to both the zero-resistance and Meissner effect in superconductors. Using finite element simulations, the criterion to build a superconducting magnetic Wollaston prism with high encoding efficiency and low Larmor phase aberrations are presented. To achieve a high magnetic field and simplify the maintenance, we optimize the design using careful thermal analysis. The measured neutron spin flipping efficiency is measured to be independent of both the neutron wavelength and energizing current, which is a significant improvement over other devices with similar functions. A highly linear variation of the Larmor phase is measured across the device, which ensures a highly uniform encoding of scattering angles into the neutron spin Larmor phase. Using two WPs, the correlation function for a colloidal silica sample was measured by spin echo modulated small angle neutron scattering (SEMSANS) and agrees well with other techniques. Using Monte Carlo code (McStas), we further investigated the SEMSANS setup and showed the requirements to improve its performance. We have proposed a new technique to implement neutron spin echo on a triple axis neutron spectrometer to achieve high resolution measurements of the lifetime of dispersive phonon excitations. The spin echo is tuned by appropriate choice of magnetic fields instead of physically tilting the coils used in traditional methods. This new approach allows a higher energy resolution and a larger effective tilting angle and hence larger group velocity to be measured.