Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
4
result(s) for
"Li, Xiaoguang (Sunny)"
Sort by:
Simultaneous extraction and determination of monoamine neurotransmitters in human urine for clinical routine testing based on a dual functional solid phase extraction assisted by phenylboronic acid coupled with liquid chromatography-tandem mass spectrometry
2017
The major monoamine neurotransmitters, serotonin (5-HT) and catecholamines (i.e., norepinephrine (NE), epinephrine (E), and dopamine (DA)), are critical to the nervous system function, and imbalances of the neurotransmitters have been connected to a variety of diseases, making their measurement useful in a clinical setting. A simple, rapid, robust, sensitive, and specific LC-MS/MS method has been developed and validated for the simultaneous quantitation of urinary serotonin and catecholamines with low cost, which is ideal for routine clinical applications. A simple extraction from complex urine was accomplished using tailored solid phase extraction incorporating phenylboronic acid complexation on a 96-well HLB microplate for the sample extraction and resulted in significantly improved throughput, selectivity, and extraction recovery. Compared to 1–10 mL of urine typically used, this method required only 10 μL. A rapid chromatographic elution with a total cycle time of 6 min per sample compared to reported run times of 19–75 min was achieved on a PFP column. The sensitivity of l and 2 ng mL
−1
for the detection of low abundant E and NE combined with the high coverage of 1024 ng mL
−1
for DA enabled the multi-analyte detection of these biogenic amines in a single run. Good linearity (2.0–512, 1.0–512, 4.0–1024, and 4.0–1024 ng mL
−1
for NE, E, DA, and 5-HT, respectively), accuracy (87.6–104.0%), precision (≤8.0%), extraction recovery (69.6–103.7%), and matrix effect (87.1–113.1% for catecholamines and 63.6–71.4% for 5-HT) were obtained. No autosampler carryover was observed. The analytes were stable for 5 days at 20 °C, 14 days at 4 °C, and 30 days at −20 °C and five freeze–thaw cycles. The easy sample preparation, rapid LC, and multi-analyte MS detection allow two 96-well plates of samples to be extracted within 2 h and analyzed on an LC-MS/MS system within 24 h. The applicability and reliability of the assay were demonstrated by assessment of the reference interval for authentic urine specimens from 90 healthy individuals.
Graphical abstract
A simple, rapid, robust, sensitive and specific LC-MS/MS method combined with a dual functional solid phase extraction has been developed and validated for the simultaneous extraction and quantitation of monoamine neurotransmitters in human urine with low cost
Journal Article
Development and validation of a specific and sensitive LC-MS/MS method for quantification of urinary catecholamines and application in biological variation studies
2014
Catecholamines are a class of biogenic amines that play an important role as neurotransmitters and hormones. We developed and validated a rapid, specific and sensitive LC-MS/MS method for quantitative determination of catecholamines in human urine. Linearity, specificity, sensitivity, precision, accuracy, matrix effect, carryover, analyte stability, method comparison and reference range were evaluated. The catecholamine measurements were not affected by 35 structurally-related drugs and metabolites. The outstanding specificity was achieved by use of a specific diphenylborate-based solid phase extraction and subsequent selective LC-MS/MS analysis. Excellent sensitivity, accuracy and precision (average intra-assay variations <2.9 % and inter-assay variations <4.6 %) were obtained. The method was successfully applied in the study of day-to-day biological within- and between-subject variations of 25 healthy people under free-living conditions over three consecutive days. We observed that catecholamine excretions for second morning sampling had least day-to-day within-subject variation and excellent reproducibility. This work is one of the rare studies on these topics and represents the first utilization of advanced LC-MS/MS technology. Additionally, we found significant correlations between spot and conventional 24 h collections of human urine (n = 22, r > 0.853,
p
< 0.0001). These findings suggest that determining the catecholamine concentrations in the second morning urine sample presents accurate, convenient and reliable measurement of catecholamine excretions. In addition, consistent and significant diurnal variations for norepinephrine and epinephrine excretions were observed during the three-day period, while dopamine did not exhibit a diurnal rhythm. The LC-MS/MS method presented here is rapid, sensitive and specific, which could be an advantage in clinical laboratories.
Graphical Abstract
Diurnal variation of urinary catecholamines for 25 healthy people in three consecutive days
Journal Article
Tailored 96-well μElution solid-phase extraction combined with UFLC-MS/MS: a significantly improved approach for determination of free 3-nitrotyrosine in human urine
by
Li, Shu
,
Kellermann, Gottfried
,
Li, Xiaoguang (Sunny)
in
ammonium acetate
,
Analytical Chemistry
,
Biochemistry
2015
We developed and validated a simple and fast UFLC-MS/MS method for the accurate determination of 3-nitrotyrosine (3-NT) in human urine as a noninvasive biomarker for oxidative stress. The method, involving tailored 96-well μElution solid-phase extraction (SPE) combined with UFLC-MS/MS, allows 3-NT to be determined in biological samples without the need for hydrolysis, derivatization, evaporation, and two-dimensional LC for the first time. Using ammonium acetate (pH 9, 25 mM) as an elution buffer was found to improve SPE selectivity. Fast chromatographic elution of 3-NT with a total run time of 7 min was achieved on a PFPP column (150 mm × 2.1 mm, 3 μm). This fine-tuned integrated method delivered significantly improved throughput, specificity, and sensitivity while reducing the matrix effect, solvent usage, and waste disposal. Using this simple and rapid method, two plates of urine samples (n = 192) can be processed within 24 h. The lower limit of quantification for 3-NT is 10 pg/mL, which represents a notable sensitivity enhancement over reported methods. Less than 6.0 % variations for intraday and interday assay precisions and 97.7–106.3 % for accuracies in terms of recovery were obtained. The applicability and reliability of the method were demonstrated by determining the reference range in human urine for 82 healthy people. Considering the noninvasive and inexpensive nature of urine sampling, this novel method could be used to re-evaluate the role of 3-NT as an oxidative stress biomarker in pre-clinical and clinical studies.
Journal Article
Tailored 96-well muElution solid-phase extraction combined with UFLC-MS/MS: a significantly improved approach for determination of free 3-nitrotyrosine in human urine
by
Li, Shu
,
Kellermann, Gottfried
,
Li, Xiaoguang (Sunny)
in
Ammonium
,
Biological samples
,
Biomarkers
2015
We developed and validated a simple and fast UFLC-MS/MS method for the accurate determination of 3-nitrotyrosine (3-NT) in human urine as a noninvasive biomarker for oxidative stress. The method, involving tailored 96-well [mu]Elution solid-phase extraction (SPE) combined with UFLC-MS/MS, allows 3-NT to be determined in biological samples without the need for hydrolysis, derivatization, evaporation, and two-dimensional LC for the first time. Using ammonium acetate (pH 9, 25 mM) as an elution buffer was found to improve SPE selectivity. Fast chromatographic elution of 3-NT with a total run time of 7 min was achieved on a PFPP column (150 mm × 2.1 mm, 3 [mu]m). This fine-tuned integrated method delivered significantly improved throughput, specificity, and sensitivity while reducing the matrix effect, solvent usage, and waste disposal. Using this simple and rapid method, two plates of urine samples (n = 192) can be processed within 24 h. The lower limit of quantification for 3-NT is 10 pg/mL, which represents a notable sensitivity enhancement over reported methods. Less than 6.0 % variations for intraday and interday assay precisions and 97.7-106.3 % for accuracies in terms of recovery were obtained. The applicability and reliability of the method were demonstrated by determining the reference range in human urine for 82 healthy people. Considering the noninvasive and inexpensive nature of urine sampling, this novel method could be used to re-evaluate the role of 3-NT as an oxidative stress biomarker in pre-clinical and clinical studies.
Journal Article