Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
2 result(s) for "Liskov, Steven"
Sort by:
How Antiarrhythmic Drugs Are Being Used in Patients With Heart Failure: Results of a Global Survey of Cardiologists
•Prescribing practices of antiarrhythmic drugs vary in cardiologists.•Antiarrhythmic drug prescribing practices deviate from guideline recommendations.•Deviation from recommendations largely surrounded sotalol and class 1C agent use.
Anatomical characteristics of the membranous septum are predictive of pacemaker requirement in patients undergoing transcatheter aortic valve replacement
PurposeWe aimed to study the characteristics of the membranous septum (MS) and its relationship with the aortic valve (AoV) and aortic annulus (AA) in patients who required PPM post-TAVR.MethodsWe performed a retrospective case–control study of 144 patients undergoing TAVR from 2016 to 2018. Thirty-four patients, requiring PPM implantation, were compared with 34 matched controls who did not require pacing. The total MS length, supra-annular MS (SA-MS) length, infra-annular MS (IA-MS) length, angle between the plane of the AA and MS (AA-MS), and degree of AoV calcifications (AVC) were obtained from preoperative CT. AoV prosthesis implantation depth was obtained from intra-operative fluoroscopy.ResultsThere were no significant differences in valve type (self-expandable: 23 cases vs 25 controls, and balloon-expandable: 11 vs 9, p = 0.79), degree of AVC (0.65 cm3 vs 0.82 cm3, p = 0.62), or implantation depth (7.76 mm vs 7.28 mm, p = 0.83). Compared to controls, there was no difference in total MS length (6.68 mm vs 6.06 mm, p = 0.97), but the IA-MS was significantly shorter (3.64 mm vs 4.56 mm, p = 0.02) and the SA-MS was significantly longer (2.73 mm vs 1.67 mm, p = 0.02) in patients requiring PPM. Patients requiring PPM also had a larger AA-MS angle (103.5° vs 96.7°, p = 0.01).ConclusionThe position of the MS with respect to the AA and MS distance below the annular plane were more closely associated with post-TAVR conduction abnormalities requiring PPM than the absolute length of the MS. Patients undergoing TAVR with such anatomy have a higher risk of requiring PPM and should be monitored for developing these complications.