Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
138
result(s) for
"M. Murra"
Sort by:
Design, construction and commissioning of a high-flow radon removal system for XENONnT
2022
A high-flow radon removal system based on cryogenic distillation was developed and constructed to reduce radon-induced backgrounds in liquid xenon detectors for rare event searches such as XENONnT. A continuous purification of the XENONnT liquid xenon inventory of 8.4 tonnes at process flows up to 71 kg/h (200 slpm) is required to achieve a radon reduction by a factor larger than two for radon sources inside the detector. To reach such high flows, the distillation column’s design features liquid xenon inlet and outlets along with novel custom-made bath-type heat exchangers with high liquefaction capabilities. The distillation process was designed using a modification of the McCabe–Thiele approach without a bottom product extraction. The thermodynamic concept is based on a Clausius–Rankine cooling cycle with phase-changing medium, in this case the xenon itself. To drastically reduce the external cooling power requirements, an energy efficient heat pump concept was developed applying a custom-made four cylinder magnetically-coupled piston pump as compressor. The distillation system was operated at thermodynamically stable conditions at a process flow of (91±2)kg/h ((258±6) slpm), 30% over design. With this flow, a activity concentration <1μBq/kg is expected inside the XENONnT detector given the measured radon source distribution.
Journal Article
Energy resolution and linearity of XENON1T in the MeV energy range
2020
Xenon dual-phase time projection chambers designed to search for weakly interacting massive particles have so far shown a relative energy resolution which degrades with energy above
∼
200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of
136
Xe
at its
Q
value,
Q
β
β
≃
2.46
MeV
. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at
1
σ
/
μ
is as low as (
0.80
±
0.02
) % in its one-ton fiducial mass, and for single-site interactions at
Q
β
β
. We also present a new signal correction method to rectify the saturation effects of the signal readout system, resulting in more accurate position reconstruction and indirectly improving the energy resolution. The very good result achieved in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.
Journal Article
Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of$$^{136}$$ Xe
2020
The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of$$^{136}$$136 Xe. Out of its 50 t total natural xenon inventory, 40 t will be the active target of a time projection chamber which thus contains about 3.6 t of$$^{136}$$136 Xe. Here, we show that its projected half-life sensitivity is$$2.4\\times {10}^{27}\\,{\\hbox {year}}$$2.4 × 10 27 year , using a fiducial volume of 5 t of natural xenon and 10 year of operation with a background rate of less than 0.2 events/(t $$\\cdot $$· year) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in$$^{136}$$136 Xe.
Journal Article
Material radioassay and selection for the XENON1T dark matter experiment
by
Garbini, M.
,
Aprile, E.
,
Sartorelli, G.
in
Astronomy
,
Astrophysics and Cosmology
,
Computer simulation
2017
The XENON1T dark matter experiment aims to detect weakly interacting massive particles (WIMPs) through low-energy interactions with xenon atoms. To detect such a rare event necessitates the use of radiopure materials to minimize the number of background events within the expected WIMP signal region. In this paper we report the results of an extensive material radioassay campaign for the XENON1T experiment. Using gamma-ray spectroscopy and mass spectrometry techniques, systematic measurements of trace radioactive impurities in over one hundred samples within a wide range of materials were performed. The measured activities allowed for stringent selection and placement of materials during the detector construction phase and provided the input for XENON1T detection sensitivity estimates through Monte Carlo simulations.
Journal Article
Removing krypton from xenon by cryogenic distillation to the ppq level
by
Garbini, M.
,
Aprile, E.
,
Sartorelli, G.
in
Astronomy
,
Astrophysics and Cosmology
,
Background radiation
2017
The XENON1T experiment aims for the direct detection of dark matter in a detector filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the
β
-emitter
85
Kr which is present in the xenon. For XENON1T a concentration of natural krypton in xenon
nat
Kr
/
Xe
<
200
ppq
(parts per quadrillion,
1
ppq
=
10
-
15
mol
/
mol
) is required. In this work, the design, construction and test of a novel cryogenic distillation column using the common McCabe–Thiele approach is described. The system demonstrated a krypton reduction factor of
6.4
·
10
5
with thermodynamic stability at process speeds above 3 kg/h. The resulting concentration of
nat
Kr
/
Xe
<
26
ppq
is the lowest ever achieved, almost one order of magnitude below the requirements for XENON1T and even sufficient for future dark matter experiments using liquid xenon, such as XENONnT and DARWIN.
Journal Article
Magnetically-coupled piston pump for high-purity gas applications
2018
Experiments based on noble elements such as gaseous or liquid argon or xenon utilize the ionization and scintillation properties of the target materials to detect radiation-induced recoils. A requirement for high light and charge yields is to reduce electronegative impurities well below the ppb (parts per billion, 1 ppb \\[=1\\times 10^{-9}\\] mol/mol) level. To achieve this, the target material is continuously circulated in the gas phase through a purifier and returned to the detector. Additionally, the low backgrounds necessary dictate low-Rn-emanation rates from all components that contact the gas. Since commercial pumps often introduce electronegative impurities from lubricants on internal components or through small air leaks, and are not designed to meet the radiopurity requirements, custom-built pumps are an advantageous alternative. A new pump has been developed in Muenster in cooperation with the nEXO group at Stanford University and the nEXO/XENON group at Rensselaer Polytechnic Institute based on a magnetically-coupled piston in a hermetically sealed low-Rn-emanating vessel. This pump delivers high performance for noble gases, reaching more than 210 standard liters per minute (slpm) with argon and more than 170 slpm with xenon while maintaining a compression of up to 1.9 bar, demonstrating its capability for noble gas detectors and other applications requiring high standards of gas purity.
Journal Article
Erratum to: Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of$$^{136}$$ Xe
2023
We correct an overestimation of the production rate of$$^{137}$$137 Xe in the DARWIN detector operated at LNGS. This formerly dominant intrinsic background source is now at a level similar to the irreducible background from solar$$^8$$8 B neutrinos, thus unproblematic at the LNGS depth. The projected half-life sensitivity for the neutrinoless double beta decay ($$0\\nu \\beta \\beta $$0 ν β β ) of$$^{136}$$136 Xe improves by$$22\\%$$22 % compared to the previously reported number and is now$$T^{0\\nu }_{1/2}= {3.0\\times 10^{27}} \\hbox { yr}$$T 1 / 2 0 ν = 3.0 × 10 27 yr (90% C.L.) after 10 years of DARWIN operation.
Journal Article
Intrinsic backgrounds from Rn and Kr in the XENON100 experiment
2018
In this paper, we describe the XENON100 data analyses used to assess the target-intrinsic background sources radon ([InlineMediaObject not available: see fulltext.]), thoron ([InlineMediaObject not available: see fulltext.]) and krypton ([InlineMediaObject not available: see fulltext.]). We detail the event selections of high-energy alpha particles and decay-specific delayed coincidences. We derive distributions of the individual radionuclides inside the detector and quantify their abundances during the main three science runs of the experiment over a period of ∼4years, from January 2010 to January 2014. We compare our results to external measurements of radon emanation and krypton concentrations where we find good agreement. We report an observed reduction in concentrations of radon daughters that we attribute to the plating-out of charged ions on the negatively biased cathode.
Journal Article
A cryogenic distillation column for the XENON1T experiment
2014
The XENON collaboration aims for the direct detection of cold dark matter in form of weakly interacting massive particles (WIMPs). A dual phase time projection chamber filled with liquid xenon is used to detect the WIMP-nucleon interaction. For the next generation experiment XENON1T with an active target mass of 1 ton of xenon, a new distillation column to remove krypton out of xenon to a concentration of < 5 × 10−13 (0.5 ppt) natural krypton in xenon is designed and tested at the Institut für Kernphysik, Universitat Munster. The experimental setup together with two diagnostic tools is presented, as well as one stability test of a 11 hour distillation run at the designed flowrate of 3 kg per hour.
Journal Article
The XENONnT dark matter experiment
by
Zavattini, G.
,
Glade-Beucke, R.
,
Kobayashi, M.
in
Astronomy
,
Astrophysics and Cosmology
,
Comparative analysis
2024
The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in cryostat). The experiment is expected to extend the sensitivity to WIMP dark matter by more than an order of magnitude compared to XENON1T, thanks to the larger active mass and the significantly reduced background, improved by novel systems such as a radon removal plant and a neutron veto. This article describes the XENONnT experiment and its sub-systems in detail and reports on the detector performance during the first science run.
Journal Article