Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
293 result(s) for "Madigan, R"
Sort by:
Were they in the loop during automated driving? Links between visual attention and crash potential
BackgroundA proposed advantage of vehicle automation is that it relieves drivers from the moment-to-moment demands of driving, to engage in other, non-driving related, tasks. However, it is important to gain an understanding of drivers’ capacity to resume manual control, should such a need arise. As automation removes vehicle control-based measures as a performance indicator, other metrics must be explored.MethodsThis driving simulator study, conducted under the European Commission (EC) funded AdaptIVe project, assessed drivers’ gaze fixations during partially-automated (SAE Level 2) driving, on approach to critical and non-critical events. Using a between-participant design, 75 drivers experienced automation with one of five out-of-the-loop (OOTL) manipulations, which used different levels of screen visibility and secondary tasks to induce varying levels of engagement with the driving task: 1) no manipulation, 2) manipulation by light fog, 3) manipulation by heavy fog, 4) manipulation by heavy fog plus a visual task, 5) no manipulation plus an n-back task.ResultsThe OOTL manipulations influenced drivers’ first point of gaze fixation after they were asked to attend to an evolving event. Differences resolved within one second and visual attention allocation adapted with repeated events, yet crash outcome was not different between OOTL manipulation groups. Drivers who crashed in the first critical event showed an erratic pattern of eye fixations towards the road centre on approach to the event, while those who did not demonstrated a more stable pattern.ConclusionsAutomated driving systems should be able to direct drivers’ attention to hazards no less than 6 seconds in advance of an adverse outcome.
Demonstration of neutrinoless double beta decay searches in gaseous xenon with NEXT
A bstract The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in 136 Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterráneo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means of the topology of the reconstructed tracks, NEXT-White has been exploited beyond its original goals in order to perform a neu- trinoless double beta decay search. The analysis considers the combination of 271.6 days of 136 Xe-enriched data and 208.9 days of 136 Xe-depleted data. A detailed background modeling and measurement has been developed, ensuring the time stability of the radiogenic and cosmogenic contributions across both data samples. Limits to the neutrinoless mode are obtained in two alternative analyses: a background-model-dependent approach and a novel direct background-subtraction technique, offering results with small dependence on the background model assumptions. With a fiducial mass of only 3.50 ± 0.01 kg of 136 Xe-enriched xenon, 90% C.L. lower limits to the neutrinoless double beta decay are found in the T 1 / 2 0 ν > 5 . 5 × 10 23 − 1 . 3 × 10 24 yr range, depending on the method. The presented techniques stand as a proof-of-concept for the searches to be implemented with larger NEXT detectors.
Rationale and design of the Clarification of Optimal Anticoagulation through Genetics trial
Current dosing practices for warfarin are empiric and result in the need for frequent dose changes as the international normalized ratio gets too high or too low. As a result, patients are put at increased risk for thromboembolism, bleeding, and premature discontinuation of anticoagulation therapy. Prior research has identified clinical and genetic factors that can alter warfarin dose requirements, but few randomized clinical trials have examined the utility of using clinical and genetic information to improve anticoagulation control or clinical outcomes among a large, diverse group of patients initiating warfarin. The COAG trial is a multicenter, double-blind, randomized trial comparing 2 approaches to guiding warfarin therapy initiation: initiation of warfarin therapy based on algorithms using clinical information plus an individual's genotype using genes known to influence warfarin response (“genotype-guided dosing”) versus only clinical information (“clinical-guided dosing”) (www.clinicaltrials.gov Identifier: NCT00839657). The COAG trial design is described. The study hypothesis is that, among 1,022 enrolled patients, genotype-guided dosing relative to clinical-guided dosing during the initial dosing period will increase the percentage of time that patients spend in the therapeutic international normalized ratio range in the first 4 weeks of therapy. The COAG will determine if genetic information provides added benefit above and beyond clinical information alone.
Fluorescence imaging of individual ions and molecules in pressurized noble gases for barium tagging in 136Xe
The imaging of individual Ba 2+ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba 2+ ion imaging inside a high-pressure xenon gas environment. Ba 2+ ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with scan area of 1 × 1 cm 2 located inside 10 bar of xenon gas. This form of microscopy represents key ingredient in the development of barium tagging for neutrinoless double beta decay searches in 136 Xe. This also provides a new tool for studying the photophysics of fluorescent molecules and chemosensors at the solid-gas interface to enable bottom-up design of catalysts and sensors. Barium tagging is a key ingredient for future detectors of neutrinoless double beta decay in low-background environments. Here, the authors demonstrate fluorescence imaging of single Ba2+ ions in high pressure Xenon gas, by comparing activity between Ba2+ chelated and unchelated samples of crown-ether chemosensors.
Demonstration of event position reconstruction based on diffusion in the NEXT-white detector
Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift distance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high- and low-energy events. Using point-like energy deposits from 83 m Kr calibration electron captures ( E ∼ 45  keV), the position of origin of low-energy events is determined to 2 cm precision with bias < 1 mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks ( E ≥ 1.5  MeV), from radiogenic electrons, yielding a precision of 3 cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q β β in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.
Fluorescence imaging of individual ions and molecules in pressurized noble gases for barium tagging in 136 Xe
The imaging of individual Ba ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba ion imaging inside a high-pressure xenon gas environment. Ba ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with scan area of 1 × 1 cm located inside 10 bar of xenon gas. This form of microscopy represents key ingredient in the development of barium tagging for neutrinoless double beta decay searches in Xe. This also provides a new tool for studying the photophysics of fluorescent molecules and chemosensors at the solid-gas interface to enable bottom-up design of catalysts and sensors.
'HOUSE BEAUTIFUL': STYLE AND CONSUMPTION IN THE HOME
In this article we explore alternative meanings and functions of homedirected consumption, in particular those aspects of consumption which have to do with presentation and appearance (fittings, furnishings and decor). Our focus is on popular taste, on those whose needs are met principally by mass marketing rather than the avant garde or the connoisseur. Recent debates have drawn attention to the possibility of pleasure and self-expression through consumption: contrasting the active shaping of cultures of consumption with the notion of consumer as mere passive recipient, manipulated by business interests. Our work suggests that neither view gives a satisfactory account of the complex meanings of consumption in the home. 'Home' carries a heavy ideological weight and these meanings permeate interpretation of consumption for the home. Questions of style, design and tastefulness evidently cause anxiety, but they are largely subsumed by familial values (a relaxed, comfortable haven) and also by the desire to maintain 'respectability' through maintaining high house-keeping standards. We argue that women are frequently caught in the crux of the tensions these conflicting goals create.
The NEXT-100 Detector
The NEXT collaboration is dedicated to the study of double beta decays of \\(^136\\)Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution (\\( 1\\%\\) FWHM at the \\(Q_\\) value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at \\(\\)4 bar and drift fields of 74 V/cm and 118 V/cm, respectively. Alpha decays from the \\(^222\\)Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.
The Language of Psychology: APA Style as Epistemology
The rhetoric of psychology is highly stylized and consistent with its epistemological premises. In APA style, language is not permitted to call attention to itself. Authors paraphrase the words of others rather than quote them, and hedging on conclusions is the rule.