Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
18 result(s) for "Majewski, Petra"
Sort by:
Full‐field X‐ray fluorescence imaging using a Fresnel zone plate as a coded aperture: optimized reconstruction algorithm and first trial of hyperspectral XANES mapping
This study represents the first feasibility demonstration of hyperspectral X‐ray absorption near‐edge structure (XANES) mapping performed using a full‐field fluorescence imaging approach. This method may be useful in many research fields for determining the spatial distributions of the different oxidation states of an element present at low concentration in X‐ray beam‐sensitive samples. It was demonstrated that this approach could be easily performed using a full‐field imaging method where a Fresnel zone plate (FZP) was employed as a coded aperture, which represented a practical, fast and dose‐efficient alternative to the raster‐scanning technique, when these two approaches were tested at a beamline not dedicated to X‐ray imaging. The basic form of the reconstruction algorithm, which was derived from inline holography, was optimized. This enabled the spatial resolution and overall quality of the reconstructed image to be improved. The ∼62 µm spatial resolution experimentally achieved may be further optimized to about 5 µm using a smaller FZP and larger detector than those used in this investigation. The XANES spectra corresponding to the main chemical species present in the sample, obtained from the tested hyperspectral spectroscopy approach, did not exactly match those expected, as they depended on several empirical processing steps. While these results can be further improved by optimizing the linearity of the detector output via pile‐up corrections, further work is needed to establish robustness against variations in masking, background treatment, and intensity‐correction choices, especially for studying diluted specimens whose corresponding pixel intensities are similar to those of the background. The full‐field X‐ray fluorescence imaging method, where a Fresnel zone plate is employed as a coded aperture, was tested for the first time at a beamline, and its corresponding reconstruction code was optimized. It was also employed to perform, also for the first time using full‐field and fluorescence modes, hyperspectral XANES mapping.
Characterization of a pnCCD-based Camera for Applications at the 100 m X-Ray Test Facility
The 100 m long X-ray test facility (100XF for clarity) in Institute of High Energy Physics of CAS has been playing an increasingly important role in the X-ray astronomy field in China. 100XF has been contributing to the missions under development, such as the Einstein Probe mission. The facility has also been providing support to R&D of focusing X-ray optics in China that will enable future X-ray telescopes to be realized, such as the enhanced X-ray Timing and Polarization (eXTP) mission. A pnCCD-based camera has been employed at 100XF to rapidly measure the performance of the X-ray optics. In this work, we study the performance of the camera and its spectral and imaging applications at 100XF. The camera system can provide a high frame readout rate, with a low readout noise <3 e − . It is sensitive to X-ray photons in the 3–10 keV energy band with a high quantum efficiency exceeding 90%. Actually, the low threshold of detection energy range can reach down to 0.2 keV. The energy resolution can reach 145.2 eV for single events and 154.8 eV for all valid events (including single events and split events) at 6.4 keV. The camera also exhibits excellent imaging capability in both the full frame mode and the windowing mode, with a readout rate of up to 1000 Hz. Finally, a prototype of a focusing X-ray mirror shell of eXTP was smoothly measured with this camera. The obtained on-axis point-spread function and half-power diameter are consistent with expectations. It is proven that the camera can improve the capability of 100XF in characterizing the X-ray optics. This camera will be very useful for performing on-ground calibrations for future X-ray telescope missions.
The BepiColombo Mercury Imaging X-Ray Spectrometer: Science Goals, Instrument Performance and Operations
The Mercury Imaging X-ray Spectrometer is a highly novel instrument that is designed to map Mercury’s elemental composition from orbit at two angular resolutions. By observing the fluorescence X-rays generated when solar-coronal X-rays and charged particles interact with the surface regolith, MIXS will be able to measure the atomic composition of the upper ∼10-20 μm of Mercury’s surface on the day-side. Through precipitating particles on the night-side, MIXS will also determine the dynamic interaction of the planet’s surface with the surrounding space environment. MIXS is composed of two complementary elements: MIXS-C is a collimated instrument which will achieve global coverage at a similar spatial resolution to that achieved (in the northern hemisphere only – i.e. ∼ 50 – 100 km) by MESSENGER; MIXS-T is the first ever X-ray telescope to be sent to another planet and will, during periods of high solar activity (or intense precipitation of charged particles), reveal the X-ray flux from Mercury at better than 10 km resolution. The design, performance, scientific goals and operations plans of the instrument are discussed, including the initial results from commissioning in space.
Characterization of a pnCCD-based Camera for Applications at the 100 m X-Ray Test Facility
The 100 m long X-ray test facility (100XF for clarity) in Institute of High Energy Physics of CAS has been playing an increasingly important role in the X-ray astronomy field in China. 100XF has been contributing to the missions under development, such as the Einstein Probe mission. The facility has also been providing support to R&D of focusing X-ray optics in China that will enable future X-ray telescopes to be realized, such as the enhanced X-ray Timing and Polarization (eXTP) mission. A pnCCD-based camera has been employed at 100XF to rapidly measure the performance of the X-ray optics. In this work, we study the performance of the camera and its spectral and imaging applications at 100XF. The camera system can provide a high frame readout rate, with a low readout noise <3 e⁻. It is sensitive to X-ray photons in the 3–10 keV energy band with a high quantum efficiency exceeding 90%. Actually, the low threshold of detection energy range can reach down to 0.2 keV. The energy resolution can reach 145.2 eV for single events and 154.8 eV for all valid events (including single events and split events) at 6.4 keV. The camera also exhibits excellent imaging capability in both the full frame mode and the windowing mode, with a readout rate of up to 1000 Hz. Finally, a prototype of a focusing X-ray mirror shell of eXTP was smoothly measured with this camera. The obtained on-axis point-spread function and half-power diameter are consistent with expectations. It is proven that the camera can improve the capability of 100XF in characterizing the X-ray optics. This camera will be very useful for performing on-ground calibrations for future X-ray telescope missions.
The Optical Emission from Gamma-ray Quasars
We present photometric observations of six radio-loud quasars that were detected by the COMPTEL gamma-ray telescope. The data encompasses seven wavebands in the optical and near-infrared. After correction for Galactic extinction, we find a wide range in optical slopes. Two sources are as blue as optically-selected quasars, and are likely to be dominated by the accretion disc emission, while three others show colours consistent with a red synchrotron component. We discuss the properties of the COMPTEL sample of quasars, as well as the implications our observations have for multi-wavelength modelling of gamma-ray quasars.
Carbon Based Resistive Memory
We propose carbon as new resistive memory material for non-volatile memories and compare three allotropes of carbon, namely carbon nanotubes, graphene-like conductive carbon and insulating carbon for their possible application as resistance-change material in high density non-volatile memories. Repetitive high-speed switching and the potential for multi-level programming have been successfully demonstrated.