Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
47 result(s) for "Margolis, Todd"
Sort by:
A mobile phone-based retinal camera for portable wide field imaging
Digital fundus imaging is used extensively in the diagnosis, monitoring and management of many retinal diseases. Access to fundus photography is often limited by patient morbidity, high equipment cost and shortage of trained personnel. Advancements in telemedicine methods and the development of portable fundus cameras have increased the accessibility of retinal imaging, but most of these approaches rely on separate computers for viewing and transmission of fundus images. We describe a novel portable handheld smartphone-based retinal camera capable of capturing high-quality, wide field fundus images. The use of the mobile phone platform creates a fully embedded system capable of acquisition, storage and analysis of fundus images that can be directly transmitted from the phone via the wireless telecommunication system for remote evaluation.
Washington University's Ophthalmic Department: National Leader in Research, Education, and Eye Care
The Department of Ophthalmology and Visual Sciences at Washington University School of Medicine has a long history as a national leader in research, education, and eye care. With 55 full time faculty members, 15 staff optometrists, five interns, 15 residents, 10 clinical fellows, postdoctoral research fellows, and graduate students the department is a busy enterprise. Steven Couch, MD, who has a longstanding interest in thyroid eye disease, discuses the data supporting the use of teprotumumab, the first and only FDA approved therapy for the treatment of this condition.As one of the investigators in the clinical trials of this drug, Dr. Couch has firsthand experience with the patients enrolled in these studies as well with how the data for these studies was analyzed.
Incomplete response to artificial tears is associated with features of neuropathic ocular pain
AimsArtificial tears are first-line therapy for patients with dry eye symptoms. It is not known, however, which patient factors associate with a positive response to therapy. The purpose of this study was to evaluate whether certain ocular and systemic findings are associated with a differential subjective response to artificial tears.MethodsCross-sectional study of 118 individuals reporting artificial tears use (hypromellose 0.4%) to treat dry eye-associated ocular pain. An evaluation was performed to assess dry eye symptoms (via the dry eye questionnaire 5 and ocular surface disease index), ocular and systemic (non-ocular) pain complaints and ocular signs (tear osmolarity, tear breakup time, corneal staining, Schirmer testing with anaesthesia, and eyelid and meibomian gland assessment). The main outcome measures were factors associated with differential subjective response to artificial tears.ResultsBy self-report, 23 patients reported no improvement, 73 partial improvement and 22 complete improvement in ocular pain with artificial tears. Patients who reported no or partial improvement in pain with artificial tears reported higher levels of hot-burning ocular pain and sensitivity to wind compared with those with complete improvement. Patients were also asked to rate the intensity of systemic pain elsewhere in the body (other than the eye). Patients who reported no or incomplete improvement with artificial tears had higher systemic pain scores compared with those with complete improvement.ConclusionsBoth ocular and systemic (non-ocular) pain complaints are associated with a differential subjective response to artificial tears.
Dry eye symptoms align more closely to non-ocular conditions than to tear film parameters
ObjectiveTo evaluate the relationship between dry eye symptoms, non-ocular conditions and tear film parameters.MethodsDesign: Cross-sectional study. Participants/setting: The study population consisted of patients who were seen in the Miami Veterans Affairs eye clinic. Patients filled out standardised questionnaires assessing dry eye symptoms (dry eye questionnaire 5 (DEQ5) and ocular surface disease index (OSDI)), non-ocular pain, depression and post-traumatic stress disorder (PTSD), and also underwent measurement of tear film parameters. Main outcome measures: Correlations between dry eye symptoms and non-ocular conditions as compared with tear film parameters.Results136 patients with a mean age of 65 (SD 11) years participated in the study. All correlations between the dry eye questionnaire scores (DEQ5 and OSDI) and (A) self-reported non-ocular pain measures (numerical rating scale and pain history), (B) depression and (C) PTSD were significant and moderate in strength (Pearson's coefficient 0.24 to 0.60, p<0.01 for all). All correlations between the dry eye questionnaires and tear film measures were weak (Pearson's coefficient −0.10 to 0.18) and most were not significant. Multivariable linear regression analyses revealed that PTSD and non-ocular pain more closely associated with dry eye symptoms than did tear film parameters. Specifically, non-ocular pain and PTSD accounted for approximately 36% of the variability in DEQ5 scores (R=0.60) and approximately 40% of variability in OSDI scores (R=0.64). Of note, none of the tear parameters remained significantly associated with dry eye symptoms in either model.ConclusionsDry eye symptoms more closely align to non-ocular pain, depression and PTSD than to tear film parameters.
Diagnostic Utility of Ocular Symptoms and Vision for Cytomegalovirus Retinitis
Cytomegalovirus (CMV) retinitis remains a leading cause of blindness in countries with a high burden of AIDS. Although dilated fundus examinations are recommended for those with CD4 counts below 100 cells/μL, in practice only those with poor vision and/or symptoms are routinely referred for screening. Therefore, the predictive value of this common practice should be assessed. This is a prospective cross-sectional study. Patients with known HIV and a CD4 count of less than 100 cells/μL attending an HIV clinic in Chiang Mai, Thailand completed a standardized questionnaire about visual symptoms and underwent visual acuity testing and dilated fundus examination. Participants without CMV retinitis were invited for repeated examinations every 3 months until their CD4 count exceeded 100 cells/μL. Patient-level statistical analyses were conducted to calculate diagnostic test characteristics, with bootstrapping to account for correlated data. Of 103 study participants, 16 had CMV retinitis diagnosed at some point during the study. Participants with CMV retinitis were more likely to complain of visual symptoms compared to those without CMV retinitis (p = 0.01), including scotoma (p = 0.0002), itchy or watery eyes (p < 0.0001), and eye pain (p = 0.003); they were also more likely to have visual acuity worse than Counting Fingers (p = 0.0003). However, the absence of eye symptoms and the absence of poor vision did not strongly affect the probability that a patient did not have disease (negative likelihood ratio 0.56 and 0.76, respectively). Ocular symptoms and poor visual acuity were poor diagnostic indicators for the presence of CMV retinitis. Systematic screening of HIV patients with CD4 counts below 100 cells/μl should be carried out to detect disease at an early stage, when blindness can still be prevented.
Dry eye symptom severity and persistence are associated with symptoms of neuropathic pain
Objective Studies of patients with non-ocular pain suggest that it is therapeutically useful to identify those with features of neuropathic pain. No data is available, however, on whether this approach has similar utility in dry eye. The purpose of this study was to determine whether severity and persistence of dry eye symptoms associate with self-reported symptoms of neuropathic ocular pain (NOP). Methods Design: Cohort study. Participants/setting: 102 men seen in the Miami Veterans Affairs eye clinic. A baseline evaluation was performed consisting of the dry eye questionnaire 5 (DEQ5) and ocular surface evaluation. Patients were contacted ≥2 years later to repeat the DEQ5 and complete questionnaires that further characterised their eye pain. Main outcome measure: The relationship between dry eye symptom severity and persistence (DEQ5) and additional measures of ocular pain (NOP). Results Of 102 patients with variable dry eye symptoms, 70 reported at least mild symptoms on both encounters (DEQ5≥6). Fifty-four of 70 (77%) reported ≥1 NOP feature, and the number of NOP features correlated moderately with dry eye symptoms at both encounters (r=0.31–0.46, p<0.01). Patients with any symptom of NOP had higher dry eye symptom scores at both encounters (p<0.05), but similar ocular surface parameters. Hypersensitivity to wind and photoallodynia were associated with having mild or greater symptoms on both encounters (OR 3.4, 95% CI 1.2 to 10.0, p=0.02; OR 15.6, 95% CI 2.0 to 123, p=0.009, respectively). Conclusions NOP features are common in patients with symptomatic dry eye and these features correlate with symptom severity and persistence.
Comparison of automated and expert human grading of diabetic retinopathy using smartphone-based retinal photography
PurposeThe aim of this study is to investigate the efficacy of a mobile platform that combines smartphone-based retinal imaging with automated grading for determining the presence of referral-warranted diabetic retinopathy (RWDR).MethodsA smartphone-based camera (RetinaScope) was used by non-ophthalmic personnel to image the retina of patients with diabetes. Images were analyzed with the Eyenuk EyeArt® system, which generated referral recommendations based on presence of diabetic retinopathy (DR) and/or markers for clinically significant macular oedema. Images were independently evaluated by two masked readers and categorized as refer/no refer. The accuracies of the graders and automated interpretation were determined by comparing results to gold standard clinical diagnoses.ResultsA total of 119 eyes from 69 patients were included. RWDR was present in 88 eyes (73.9%) and in 54 patients (78.3%). At the patient-level, automated interpretation had a sensitivity of 87.0% and specificity of 78.6%; grader 1 had a sensitivity of 96.3% and specificity of 42.9%; grader 2 had a sensitivity of 92.5% and specificity of 50.0%. At the eye-level, automated interpretation had a sensitivity of 77.8% and specificity of 71.5%; grader 1 had a sensitivity of 94.0% and specificity of 52.2%; grader 2 had a sensitivity of 89.5% and specificity of 66.9%.DiscussionRetinal photography with RetinaScope combined with automated interpretation by EyeArt achieved a lower sensitivity but higher specificity than trained expert graders. Feasibility testing was performed using non-ophthalmic personnel in a retina clinic with high disease burden. Additional studies are needed to assess efficacy of screening diabetic patients from general population.
Unusual Abundance of Atypical Strains Associated with Human Ocular Toxoplasmosis
To facilitate genotyping of Toxoplasma gondii in vitreous fluid of patients with severe or atypical ocular toxoplasmosis, polymerase chain reaction (PCR) restriction fragment length polymorphism (RFLP) assays were developed for SAG3 (p43) and SAG4 (p18), 2 single-copy surface antigen genes. Together with strategies for SAG1, SAG2 and B1 multilocus RFLP analyses were performed on PCR-amplified parasite DNA present in 12 clinical specimens. Most samples (8/12) were not infected by type II or type III mouse-avirulent strains. Only 1 type III and 3 type II strains were identified, all from immunosuppressed patients. In 6 otherwise healthy adults and in 1 immunosuppressed patient, the SAG1 allele associated with mouse virulence was amplified. Of 12 samples, 3 possessed true type I strains; 5 of 12 had new recombinant genotypes with alleles typical of type I or III strains at all loci examined. The unusual bias toward type I and/or recombinant genotypes bearing the SAG1 type I allele associated with mouse virulence in immunocompetent adults has important implications for the epidemiology and efficacious treatment of ocular toxoplasmosis
Smartphone-based fundus photography for screening of plus-disease retinopathy of prematurity
BackgroundInadequate screening of treatment-warranted retinopathy of prematurity (ROP) can lead to devastating visual outcomes. Especially in resource-poor communities, the use of an affordable, portable, and easy to use smartphone-based non-contact fundus photography device may prove useful for screening for high-risk ROP. This study evaluates the feasibility of screening for high-risk ROP using a novel smartphone-based fundus photography device, RetinaScope.MethodsRetinal images were obtained using RetinaScope on a cohort of prematurely born infants during routine examinations for ROP. Images were reviewed by two masked graders who determined the image quality, the presence or absence of plus disease, and whether there was retinopathy that met predefined criteria for referral. The agreement between image-based assessments was compared to the gold standard indirect ophthalmoscopic assessment.ResultsFifty-four eyes of 27 infants were included. A wide-field fundus photograph was obtained using RetinaScope. Image quality was acceptable or excellent in 98% and 95% of cases. There was substantial agreement between the gold standard and photographic assessment of presence or absence of plus disease (Cohen’s κ = 0.85). Intergrader agreement on the presence of any retinopathy in photographs was also high (κ = 0.92).ConclusionsRetinaScope can capture digital retinal photographs of prematurely born infants with good image quality for grading of plus disease.
Visual acuity outcomes in cytomegalovirus retinitis: early versus late diagnosis
AimsTo determine if early dilated fundus examination for cytomegalovirus (CMV) retinitis leads to better visual outcomes in areas with limited HIV care, where patients may have long-standing retinitis before they are diagnosed with HIV.MethodsTwenty-four eyes of 17 patients with CMV retinitis who were seen at an urban HIV clinic in Chiang Mai, Thailand, were included in this retrospective cohort study. Participants were divided into two groups based on the amount of time from the first documented CD4 count below 100 cells/mm3 to the first eye examination for CMV retinitis. Average visual acuity in each group was calculated at the time CMV retinitis was first detected, and then at 3, 6 and 12 months after diagnosis.ResultsThe group of patients who received an eye examination within approximately 4 months of the initial low CD4 count measurement had better baseline visual acuity (median 20/30,IQR 20/20 to 20/60) compared with patients who presented later (median 20/80, 20/60 to hand motion); p=0.03). Visual acuity did not change significantly during the 12-month study period in either the early group (p=0.69) or late group (p=0.17).ConclusionIn this study, patients who were examined sooner after a low CD4 count had better vision than patients who were examined later. Routine early screening of patients with CD4 counts under below 100 cells/mm3 may detect earlier disease and prevent vision loss.