Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
5 result(s) for "Mbatsane, Enough"
Sort by:
Prospective acceptability of a multipurpose technology (MPT) implant in preclinical development to prevent HIV and unplanned pregnancy: Qualitative insights from women end users and health care providers in South Africa and Zimbabwe
Given the high rates of both HIV and unintended pregnancies in sub-Saharan Africa, the SCHIELD program aims to develop a multipurpose technology implant for HIV and pregnancy prevention. An end-user evaluation was undertaken with young women and health care providers to assess preferences for modifiable implant attributes to improve future adoption and rollout. Focus group discussions were conducted with potential women end users, and health care providers experienced in implant insertion or removal participated in in-depth interviews. All participants were recruited from Harare, Zimbabwe, or Soshanguve, South Africa. The purposively stratified sampled women were either implant experienced or implant naïve and were categorized into three groups: nulliparous, postpartum, or engaged in transactional sex. Topics covered included duration (six months to three years), biodegradability, removability, and independent rod retrievability (per indication). Data were analyzed using Dedoose software and summarized into emerging themes. Participants identified three key areas that could facilitate rollout, uptake, and adherence of an implant for HIV and pregnancy prevention. First, discreetness was the most salient topic and was associated with implant characteristics such as anatomical location, flexibility, and biodegradability. Second, the ability to independently retrieve the HIV or pregnancy prevention component was preferred, as life circumstances may change and was favored by all participants, except for young women in Soshanguve. Third, there is a need for proper counseling, sensitization, provider training, and health campaigns to facilitate rollout of a 2-in-1 implant. A 2-in-1 implant was seen as highly desirable by most young women and health care providers. Participants discussed potential concerns and barriers to uptake of a biodegradable implant with dual HIV prevention and contraceptive properties, identifying key implant attributes that product developers can modify while still in preclinical stages.
Sexual behaviour among women using intramuscular depot medroxyprogesterone acetate, a copper intrauterine device, or a levonorgestrel implant for contraception: Data from the ECHO randomized trial
Contraceptive use has complex effects on sexual behaviour and mood, including those related to reduced concerns about unintended pregnancy, direct hormonal effects and effects on endogenous sex hormones. We set out to obtain robust evidence on the relative effects of three contraceptive methods on sex behaviours, which is important for guiding contraceptive choice and future contraceptive developments. This is a secondary analysis of data from the Evidence for Contraceptive Options and HIV Outcomes (ECHO) randomized trial in which 7,829 HIV-uninfected women from 12 sites in Eswatini, Kenya, South Africa and Zambia seeking contraception were randomly assigned to intramuscular depot-medroxyprogesterone acetate (DMPA-IM), the copper intrauterine device (Cu-IUD) or the levonorgestrel (LNG) implant. Data collected for 12 to 18 months using 3-monthly behavioural questionnaires that relied on recall from the preceding 3 months, were used to estimate relative risk of post-baseline sex behaviours, as well as sexual desire and menstrual bleeding between randomized groups using modified Poisson regression. We observed small but generally consistent effects wherein DMPA-IM users reported lower prevalence of specified high risk sexual behaviours than implant users than Cu-IUD users (the '>' and '<' symbols indicate statistically significant differences): multiple sex partners 3.6% < 4.8% < 6.2% respectively; new sex partner 3.0% < 4.0% <5.3%; coital acts 16.45, 16.65, 17.12 (DMPA-IM < Cu-IUD); unprotected sex 65% < 68%, 70%; unprotected sex past 7 days 33% <36%, 37%; sex during vaginal bleeding 7.1%, 7.1% < 8.9%; no sex acts 4.1%, 3.8%, 3.4% (DMPA-IM > Cu-IUD); partner has sex with others 10% < 11%, 11%. The one exception was having any sex partner 96.5%, 96.9% < 97.4% (DMPA-IM < Cu-IUD). Decrease in sexual desire was reported by 1.6% > 1.1% >0.5%; amenorrhoea by 49% > 41% >12% and regular menstrual pattern by 26% <35% < 87% respectively. These findings suggest that women assigned to DMPA-IM may have a modest decrease in libido and sexual activity relative to the implant, and the implant relative to the Cu-IUD. We found more menstrual disturbance with DMPA-IM than with the implant (and as expected, both more than the Cu-IUD). These findings are important for informing the contraceptive choices of women and policymakers and highlight the need for robust comparison of the effects of other contraceptive methods as well.
Prospective acceptability of a multipurpose technology
Given the high rates of both HIV and unintended pregnancies in sub-Saharan Africa, the SCHIELD program aims to develop a multipurpose technology implant for HIV and pregnancy prevention. An end-user evaluation was undertaken with young women and health care providers to assess preferences for modifiable implant attributes to improve future adoption and rollout. Focus group discussions were conducted with potential women end users, and health care providers experienced in implant insertion or removal participated in in-depth interviews. All participants were recruited from Harare, Zimbabwe, or Soshanguve, South Africa. The purposively stratified sampled women were either implant experienced or implant naïve and were categorized into three groups: nulliparous, postpartum, or engaged in transactional sex. Topics covered included duration (six months to three years), biodegradability, removability, and independent rod retrievability (per indication). Data were analyzed using Dedoose software and summarized into emerging themes. A 2-in-1 implant was seen as highly desirable by most young women and health care providers. Participants discussed potential concerns and barriers to uptake of a biodegradable implant with dual HIV prevention and contraceptive properties, identifying key implant attributes that product developers can modify while still in preclinical stages.
\We are not the same\: African women's view of multipurpose prevention products in the TRIO clinical study
Unintended pregnancy and HIV infection present dual risks for young women in sub-Saharan Africa. New multipurpose prevention technologies (MPTs) are in development to simultaneously prevent unintended pregnancy and HIV, but there is a need for end-user research to ensure these products suit women's needs. The Tablet, Rings and Injectables as Options (TRIO) for women study took place in Kisumu, Kenya, and Soshanguve, South Africa, with the goal of eliciting young women's feedback on three potential MPTs. Women in TRIO used three placebo products that represented potential MPTs: daily oral tablets, monthly vaginal rings, and monthly dual injections in a randomized crossover design followed by a period in which they chose a product to use. Eighty-eight TRIO participants completed in-depth interviews and focus group discussions to understand their experiences using each product. Qualitative analyses were conducted after stratifying by product preference at the end of the crossover period. The majority (65%) of participants preferred injections, with the remainder evenly split between tablets and rings. Discussions of preference for one product were closely linked with expressed dislike of another product's attributes. Participants recognized heterogeneity in preferences and choices across users and stressed the need for multiple MPT options that confer a low burden on women's daily lives. Rather than choosing a product to use based on the product's perceived advantages, women's choices were based on the unfavorable attributes of other TRIO products. Moreover, the importance that women placed on a given disadvantage varied. Disadvantages that women deemed as most important emerged as a greater driver of product preference than selecting products based on their advantages and favorable characteristics.