Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
39
result(s) for
"Meairs, S"
Sort by:
Mannheim Carotid Intima-Media Thickness and Plaque Consensus (2004–2006–2011)
2012
Intima-media thickness (IMT) provides a surrogate end point of cardiovascular outcomes in clinical trials evaluating the efficacy of cardiovascular risk factor modification. Carotid artery plaque further adds to the cardiovascular risk assessment. It is defined as a focal structure that encroaches into the arterial lumen of at least 0.5 mm or 50% of the surrounding IMT value or demonstrates a thickness >1.5 mm as measured from the media-adventitia interface to the intima-lumen interface. The scientific basis for use of IMT in clinical trials and practice includes ultrasound physics, technical and disease-related principles as well as best practice on the performance, interpretation and documentation of study results. Comparison of IMT results obtained from epidemiological and interventional studies around the world relies on harmonization on approaches to carotid image acquisition and analysis. This updated consensus document delineates further criteria to distinguish early atherosclerotic plaque formation from thickening of IMT. Standardized methods will foster homogenous data collection and analysis, improve the power of randomized clinical trials incorporating IMT and plaque measurements and facilitate the merging of large databases for meta-analyses. IMT results are applied to individual patients as an integrated assessment of cardiovascular risk factors. However, this document recommends against serial monitoring in individual patients.
Journal Article
Mannheim carotid intima-media thickness and plaque consensus (2004-2006-2011). An update on behalf of the advisory board of the 3rd, 4th and 5th watching the risk symposia, at the 13th, 15th and 20th European Stroke Conferences, Mannheim, Germany, 2004, Brussels, Belgium, 2006, and Hamburg, Germany, 2011
by
Sitzer, M
,
Touboul, P-J
,
Schminke, U
in
Cardiovascular Diseases - diagnostic imaging
,
Cardiovascular Diseases - etiology
,
Cardiovascular Diseases - pathology
2012
Intima-media thickness (IMT) provides a surrogate end point of cardiovascular outcomes in clinical trials evaluating the efficacy of cardiovascular risk factor modification. Carotid artery plaque further adds to the cardiovascular risk assessment. It is defined as a focal structure that encroaches into the arterial lumen of at least 0.5 mm or 50% of the surrounding IMT value or demonstrates a thickness >1.5 mm as measured from the media-adventitia interface to the intima-lumen interface. The scientific basis for use of IMT in clinical trials and practice includes ultrasound physics, technical and disease-related principles as well as best practice on the performance, interpretation and documentation of study results. Comparison of IMT results obtained from epidemiological and interventional studies around the world relies on harmonization on approaches to carotid image acquisition and analysis. This updated consensus document delineates further criteria to distinguish early atherosclerotic plaque formation from thickening of IMT. Standardized methods will foster homogenous data collection and analysis, improve the power of randomized clinical trials incorporating IMT and plaque measurements and facilitate the merging of large databases for meta-analyses. IMT results are applied to individual patients as an integrated assessment of cardiovascular risk factors. However, this document recommends against serial monitoring in individual patients.
Journal Article
Mannheim carotid intima-media thickness consensus (2004-2006). An update on behalf of the Advisory Board of the 3rd and 4th Watching the Risk Symposium, 13th and 15th European Stroke Conferences, Mannheim, Germany, 2004, and Brussels, Belgium, 2006
2007
Intima-media thickness (IMT) is increasingly used as a surrogate end point of vascular outcomes in clinical trials aimed at determining the success of interventions that lower risk factors for atherosclerosis and associated diseases (stroke, myocardial infarction and peripheral artery diseases). The necessity to promote further criteria to distinguish early atherosclerotic plaque formation from thickening of IMT and to standardize IMT measurements is expressed through this updated consensus. Plaque is defined as a focal structure that encroaches into the arterial lumen of at least 0.5 mm or 50% of the surrounding IMT value or demonstrates a thickness >1.5 mm as measured from the media-adventitia interface to the intima-lumen interface. Standard use of IMT measurements is based on physics, technical and disease-related principles as well as agreements on how to perform, interpret and document study results. Harmonization of carotid image acquisition and analysis is needed for the comparison of the IMT results obtained from epidemiological and interventional studies around the world. The consensus concludes that there is no need to 'treat IMT values' nor to monitor IMT values in individual patients apart from exceptions named, which emphasize that inside randomized clinical trials should be performed. Although IMT has been suggested to represent an important risk marker, according to the current evidence it does not fulfill the characteristics of an accepted risk factor. Standardized methods recommended in this consensus statement will foster homogenous data collection and analysis. This will help to improve the power of randomized clinical trials incorporating IMT measurements and to facilitate the merging of large databases for meta-analyses.
Journal Article
Mannheim Intima-Media Thickness Consensus
by
Vicaut, E.
,
Rundek, T.
,
Fatar, M.
in
Arteriosclerosis - diagnostic imaging
,
Carotid Arteries - diagnostic imaging
,
Humans
2004
Intima-media thickness (IMT) is increasingly used in clinical trials as a surrogate end point for determining the success of interventions that lower risk factors for atherosclerosis. The necessity for unified criteria to distinguish early atherosclerotic plaque formation from thickening of IMT and to standardize IMT measurements is addressed in this consensus statement. Plaque is defined as a focal structure that encroaches into the arterial lumen of at least 0.5 mm or 50% of the surrounding IMT value or demonstrates a thickness of ≧1.5 mm as measured from the media-adventitia interface to the intima-lumen interface. Standard use of IMT measurements is recommended in all epidemiological and interventional trials dealing with vascular diseases to improve characterization of the population investigated. The consensus concludes that there is no need to ‘treat IMT values’ nor to monitor IMT values in individual patients apart from few exceptions. Although IMT has been suggested to represent an important risk marker, it does not fulfill the characteristics of an accepted risk factor. Standardized methods recommended in this consensus statement will foster homogenous data collection and analysis. This will help to improve the power of studies incorporating IMT measurements and to facilitate the merging of large databases for meta-analyses.
Journal Article
Priorities for European Stroke Research - Scope and Context
by
Wahlgren, N
,
Meairs, S
2007
Journal Article
Mannheim Carotid Intima-Media Thickness Consensus (2004–2006)
2007
Intima-media thickness (IMT) is increasingly used as a surrogate end point of vascular outcomes in clinical trials aimed at determining the success of interventions that lower risk factors for atherosclerosis and associated diseases (stroke, myocardial infarction and peripheral artery diseases). The necessity to promote further criteria to distinguish early atherosclerotic plaque formation from thickening of IMT and to standardize IMT measurements is expressed through this updated consensus. Plaque is defined as a focal structure that encroaches into the arterial lumen of at least 0.5 mm or 50% of the surrounding IMT value or demonstrates a thickness >1.5 mm as measured from the media-adventitia interface to the intima-lumen interface. Standard use of IMT measurements is based on physics, technical and disease-related principles as well as agreements on how to perform, interpret and document study results. Harmonization of carotid image acquisition and analysis is needed for the comparison of the IMT results obtained from epidemiological and interventional studies around the world. The consensus concludes that there is no need to ‘treat IMT values’ nor to monitor IMT values in individual patients apart from exceptions named, which emphasize that inside randomized clinical trials should be performed. Although IMT has been suggested to represent an important risk marker, according to the current evidence it does not fulfill the characteristics of an accepted risk factor. Standardized methods recommended in this consensus statement will foster homogenous data collection and analysis. This will help to improve the power of randomized clinical trials incorporating IMT measurements and to facilitate the merging of large databases for meta-analyses.
Journal Article
Pulse-inversion contrast harmonic imaging: ultrasonographic assessment of cerebral perfusion
by
Meairs, Stephen
,
Neff, Wolfgang
,
Eschenfelder, Christopher
in
Adult
,
Biological and medical sciences
,
Brain
2000
Pulse-inversion contrast harmonic imaging is a new ultrasonographic technique that can assess brain perfusion. In an adult with moyamoya disease and multiple recurrent strokes, this method detected subtle hemispheric differences in temporallobe perfusion, presumably due to neovascularisation, which were not shown by xenon-computed tomography or magnetic resonance perfusion imaging.
Journal Article
Mannheim Carotid Intima-Media Thickness and Plaque Consensus (2004–2006–2011): An Update on Behalf of the Advisory Board of the 3rd and 4th Watching the Risk Symposium 13th and 15th European Stroke Conferences, Mannheim, Germany, 2004, and Brussels, Belgium, 2006
2012
Intima-media thickness (IMT) provides a surrogate end point of cardiovascular outcomes in clinical trials evaluating the efficacy of cardiovascular risk factor modification. Carotid artery plaque further adds to the cardiovascular risk assessment. It is defined as a focal structure that encroaches into the arterial lumen of at least 0.5 mm or 50% of the surrounding IMT value or demonstrates a thickness >1.5 mm as measured from the media-adventitia interface to the intima-lumen interface. The scientific basis for use of IMT in clinical trials and practice includes ultrasound physics, technical and disease-related principles as well as best practice on the performance, interpretation and documentation of study results. Comparison of IMT results obtained from epidemiological and interventional studies around the world relies on harmonization on approaches to carotid image acquisition and analysis. This updated consensus document delineates further criteria to distinguish early atherosclerotic plaque formation from thickening of IMT. Standardized methods will foster homogenous data collection and analysis, improve the power of randomized clinical trials incorporating IMT and plaque measurements and facilitate the merging of large databases for meta-analyses. IMT results are applied to individual patients as an integrated assessment of cardiovascular risk factors. However, this document recommends against serial monitoring in individual patients.
Journal Article