Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
20 result(s) for "Meine, Mathias"
Sort by:
Results of ENHANCED Implantable Cardioverter Defibrillator Programming to Reduce Therapies and Improve Quality of Life (from the ENHANCED-ICD Study)
Novel implantable cardioverter defibrillator (ICD) discrimination algorithms and programming strategies have significantly reduced the incidence of inappropriate shocks, but there are still gains to be made with respect to reducing appropriate but unnecessary antitachycardia pacing (ATP) and shocks. We examined whether programming a number of intervals to detect (NID) of 60/80 for ventricular tachyarrhythmia (VT)/ventricular fibrillation (VF) detection was safe and the impact of this strategy on (1) adverse events related to ICD shocks and syncopal events; (2) ATPs/shocks; and (3) patient-reported outcomes. The “ENHANCED Implantable Cardioverter Defibrillator programming to reduce therapies and improve quality of life” study (ENHANCED-ICD study) was a prospective, safety-monitoring study enrolling 60 primary and secondary prevention patients at the University Medical Center Utrecht. Patients implanted with any type of ICD with SmartShock technology and aged 18 to 80 years were eligible to participate. In all patients, a prolonged NID 60/80 was programmed. The cycle length for VT/fast VT/VF was 360/330/240 ms, respectively. Programming a NID 60/80 proved safe for ICD patients. Because of the new programming strategy, unnecessary ICD therapy was prevented in 10% of ENHANCED-ICD patients during a median follow-up period of 1.3 years. With respect to patient-reported outcomes, levels of distress were highest and perceived health status lowest at the time of implantation, which both gradually improved during follow-up. In conclusion, the ENHANCED-ICD study demonstrates that programming a NID 60/80 for VT/VF detection is safe for ICD patients and does not negatively impact their quality of life.
Acute recoordination rather than functional hemodynamic improvement determines reverse remodelling by cardiac resynchronisation therapy
Purpose: Cardiac resynchronisation therapy (CRT) improves left ventricular (LV) function acutely, with further improvements and reverse remodelling during chronic CRT. The current study investigated the relation between acute improvement of LV systolic function, acute mechanical recoordination, and long-term reverse remodelling after CRT. Methods: In 35 patients, LV speckle tracking longitudinal strain, LV volumes & ejection fraction (LVEF) were assessed by echocardiography before, acutely within three days, and 6 months after CRT. A subgroup of 25 patients underwent invasive assessment of the maximal rate of LV pressure rise (dP/dtmax,) during CRT-implantation. The acute change in dP/dtmax, LVEF, systolic discoordination (internal stretch fraction [ISF] and LV systolic rebound stretch [SRSlv]) and systolic dyssynchrony (standard deviation of peak strain times [2DS-SD18]) was studied, and their association with long-term reverse remodelling were determined. Results: CRT induced acute and ongoing recoordination (ISF from 45 ± 18 to 27 ± 11 and 23 ± 12%, p < 0.001; SRS from 2.27 ± 1.33 to 0.74 ± 0.50 and 0.71 ± 0.43%, p < 0.001) and improved LV function (dP/dtmax 668 ± 185 vs. 817 ± 198 mmHg/s, p < 0.001; stroke volume 46 ± 15 vs. 54 ± 20 and 52 ± 16 ml; LVEF 19 ± 7 vs. 23 ± 8 and 27 ± 10%, p < 0.001). Acute recoordination related to reverse remodelling (r = 0.601 and r = 0.765 for ISF & SRSlv, respectively, p < 0.001). Acute functional improvements of LV systolic function however, neither related to reverse remodelling nor to the extent of acute recoordination. Conclusion: Long-term reverse remodelling after CRT is likely determined by (acute) recoordination rather than by acute hemodynamic improvements. Discoordination may therefore be a more important CRT-substrate that can be assessed and, acutely restored.
Distinct trajectories of disease-specific health status in heart failure patients undergoing cardiac resynchronization therapy
Purpose It is well known that a significant proportion of heart failure patients (10-44 %) do not show improvement in symptoms or functioning from cardiac resynchronization therapy (CRT), yet no study has examined patient-reported health status trajectories after implantation. Methods A cohort of 139 patients with a CRT-defibrillator (70 % men; age 65.7 ± 10.1 years) completed the Kansas City Cardiomyopathy Questionnaire (KCCQ) prior to implantation (baseline) and at 2, 6, and 12-14 months post-implantation. Latent class analyses were used to identify trajectories and associates of disease-specific health status over time. Results All health status trajectories showed an initial small to large improvement from baseline to 2-month follow-up, whereafter most trajectories displayed a stable pattern between short- and long-term follow-up. Low educational level, NYHA class III/IV, smoking, no use of beta-blockers, use of psychotropic medication, anxiety, depression, and type D personality were found to be associated with poorer health status in unadjusted analyses. Interestingly, subgroups of patients (12-20 %) who experienced poor health status at baseline improved to stable good health status levels after implantation. Conclusions Levels of disease-specific health status vary considerably across subgroups of CRT-D patients. Classification into poorer disease-specific health status trajectories was particularly associated with patients' psychological profile and NYHA classification. The timely identification of CRT-D patients who present with poor disease-specific health status (i.e., KCCQ score < 50) and a distressed psychological profile (i.e., anxiety, depression, and/or type D personality) is paramount, as they may benefit from cardiac rehabilitation in combination with psychological intervention.
Comparison of strain imaging techniques in CRT candidates: CMR tagging, CMR feature tracking and speckle tracking echocardiography
Parameters using myocardial strain analysis may predict response to cardiac resynchronization therapy (CRT). As the agreement between currently available strain imaging modalities is unknown, three different modalities were compared. Twenty-seven CRT-candidates, prospectively included in the MARC study, underwent cardiac magnetic resonance (CMR) imaging and echocardiographic examination. Left ventricular (LV) circumferential strain was analysed with CMR tagging (CMR-TAG), CMR feature tracking (CMR-FT), and speckle tracking echocardiography (STE). Basic strain values and parameters of dyssynchrony and discoordination obtained with CMR-FT and STE were compared to CMR-TAG. Agreement of CMR-FT and CMR-TAG was overall fair, while agreement between STE and CMR-TAG was often poor. For both comparisons, agreement on discoordination parameters was highest, followed by dyssynchrony and basic strain parameters. For discoordination parameters, agreement on systolic stretch index was highest, with fair intra-class correlation coefficients (ICC) (CMR-FT: 0.58, STE: 0.55). ICC of septal systolic rebound stretch (SRSsept) was poor (CMR-FT: 0.41, STE: 0.30). Internal stretch factor of septal and lateral wall (ISFsep–lat) showed fair ICC values (CMR-FT: 0.53, STE: 0.46), while the ICC of the total LV (ISFLV) was fair for CMR-FT (0.55) and poor for STE (ICC: 0.32). The CURE index had a fair ICC for both comparisons (CMR-FT: 0.49, STE 0.41). Although comparison of STE to CMR-TAG was limited by methodological differences, agreement between CMR-FT and CMR-TAG was overall higher compared to STE and CMR-TAG. CMR-FT is a potential clinical alternative for CMR-TAG and STE, especially in the detection of discoordination in CRT-candidates.
Segment length in cine (SLICE) strain analysis: a practical approach to estimate potential benefit from cardiac resynchronization therapy
Background Segment length in cine (SLICE) strain analysis on standard cardiovascular magnetic resonance (CMR) cine images was recently validated against gold standard myocardial tagging. The present study aims to explore predictive value of SLICE for cardiac resynchronization therapy (CRT) response. Methods and results Fifty-seven patients with heart failure and left bundle branch block (LBBB) were prospectively enrolled in this multi-center study and underwent CMR examination before CRT implantation. Circumferential strains of the septal and lateral wall were measured by SLICE on short-axis cine images. In addition, timing and strain pattern parameters were assessed. After twelve months, CRT response was quantified by the echocardiographic change in left ventricular (LV) end-systolic volume (LVESV). In contrast to timing parameters, strain pattern parameters being systolic rebound stretch of the septum (SRS sep ), systolic stretch index (SSI sep-lat ), and internal stretch factor (ISF sep-lat ) all correlated significantly with LVESV change (R − 0.56; R − 0.53; and R − 0.58, respectively). Of all strain parameters, end-systolic septal strain (ESS sep ) showed strongest correlation with LVESV change (R − 0.63). Multivariable analysis showed ESS sep to be independently related to LVESV change together with age and QRS AREA . Conclusion The practicable SLICE strain technique may help the clinician to estimate potential benefit from CRT by analyzing standard CMR cine images without the need for commercial software. Of all strain parameters, end-systolic septal strain (ESS sep ) demonstrates the strongest correlation with reverse remodeling after CRT. This parameter may be of special interest in patients with non-strict LBBB morphology for whom CRT benefit is doubted.
Advanced image-supported lead placement in cardiac resynchronisation therapy: protocol for the multicentre, randomised controlled ADVISE trial and early economic evaluation
IntroductionAchieving optimal placement of the left ventricular (LV) lead in cardiac resynchronisation therapy (CRT) is a prerequisite in order to achieve maximum clinical benefit, and is likely to help avoid non-response. Pacing outside scar tissue and targeting late activated segments may improve outcome. The present study will be the first randomised controlled trial to compare the efficacy of real-time image-guided LV lead delivery to conventional CRT implantation. In addition, to estimate the cost-effectiveness of targeted lead implantation, an early decision analytic model was developed, and described here.Methods and analysisA multicentre, interventional, randomised, controlled trial will be conducted in a total of 130 patients with a class I or IIa indication for CRT implantation. Patients will be stratified to ischaemic heart failure aetiology and 1:1 randomised to either empirical lead placement or live image-guided lead placement. Ultimate lead location and echocardiographic assessment will be performed by core laboratories, blinded to treatment allocation and patient information. Late gadolinium enhancement cardiac magnetic resonance imaging (CMR) and CINE-CMR with feature-tracking postprocessing software will be used to semi-automatically determine myocardial scar and late mechanical activation. The subsequent treatment file with optimal LV-lead positions will be fused with the fluoroscopy, resulting in live target-visualisation during the procedure. The primary endpoint is the difference in percentage of successfully targeted LV-lead location. Secondary endpoints are relative percentage reduction in indexed LV end-systolic volume, a hierarchical clinical endpoint, and quality of life. The early analytic model was developed using a Markov-model, consisting of seven mutually exclusive health states.Ethics and disseminationThe protocol was approved by the Medical Research Ethics Committee Utrecht (NL73416.041.20). All participants are required to provide written informed consent. Results will be submitted to peer-reviewed journals.Trial registration numberNCT05053568; Trial NL8666.
Association of ECG characteristics with clinical and echocardiographic outcome to CRT in a non-LBBB patient population
PurposeEffectiveness of cardiac resynchronization therapy (CRT) in patients without left bundle branch block (non-LBBB) QRS morphology is limited. Additional selection criteria are needed to identify these patients.MethodsSeven hundred ninety consecutive patients with non-LBBB morphology, who received a CRT-device in 3 university centers in the Netherlands, were selected. Pre-implantation 12-lead ECGs were evaluated on morphology, duration, and area of the QRS complex, as well as on PR interval, left ventricular activation time (LVAT), and the presence of fragmented QRS (fQRS). Association of these ECG features with the primary endpoint: a combination of left ventricular assist device (LVAD) implantation, cardiac transplantation and all-cause mortality, and secondary endpoint—echocardiographic reduction of left ventricular end-systolic volume (LVESV)—were evaluated.ResultsThe primary endpoint occurred more often in non-LBBB patients with with PR interval ≥ 230ms, QRS area < 109μVs, and with fQRS. Multivariable regression analysis showed independent associations of QRS area (HR 2.33 [1.44, 3.77], p = 0.001) and PR interval (HR 2.03 [1.51, 2.74], p < 0.001) only. Mean LVESV reduction was significantly lower in patients with baseline RBBB, QRS duration < 150 ms, PR interval ≥ 230 ms, and in QRS area < 109 μVs. Multivariable regression analyses only showed significant associations between QRS area ≥ 109 μVs (OR 2.00 [1.09, 3.66] p = 0.025) and probability of echocardiographic response to CRT.ConclusionsIn the heterogeneous non-LBBB patient population, QRS area and PR prolongation rather than traditional QRS duration and morphology are associated to both clinical and echocardiographic outcomes of CRT.
Comparison of strain parameters in dyssynchronous heart failure between speckle tracking echocardiography vendor systems
Background Although mechanical dyssynchrony parameters derived by speckle tracking echocardiography (STE) may predict response to cardiac resynchronization therapy (CRT), comparability of parameters derived with different STE vendors is unknown. Methods In the MARC study, echocardiographic images of heart failure patients obtained before CRT implantation were prospectively analysed with vendor specific STE software (GE EchoPac and Philips QLAB) and vendor-independent software (TomTec 2DCPA). Response was defined as change in left ventricular (LV) end-systolic volume between examination before and six-months after CRT implantation. Basic longitudinal strain and mechanical dyssynchrony parameters (septal to lateral wall delay (SL-delay), septal systolic rebound stretch (SRSsept), and systolic stretch index (SSI)) were obtained from either separate septal and lateral walls, or total LV apical four chamber. Septal strain patterns were categorized in three types. The coefficient of variation and intra-class correlation coefficient (ICC) were analysed. Dyssynchrony parameters were associated with CRT response using univariate regression analysis and C-statistics. Results Two-hundred eleven patients were analysed. GE-cohort ( n  = 123): age 68 years (interquartile range (IQR): 61–73), 67% male, QRS-duration 177 ms (IQR: 160–192), LV ejection fraction: 26 ± 7%. Philips-cohort ( n  = 88): age 67 years (IQR: 59–74), 60% male, QRS-duration: 179 ms (IQR: 166–193), LV ejection fraction: 27 ± 8. LV derived peak strain was comparable in the GE- (GE: -7.3 ± 3.1%, TomTec: −6.4 ± 2.8%, ICC: 0.723) and Philips-cohort (Philips: −7.7 ± 2.7%, TomTec: −7.7 ± 3.3%, ICC: 0.749). SL-delay showed low ICC values (GE vs. TomTec: 0.078 and Philips vs. TomTec: 0.025). ICC’s of SRSsept and SSI were higher but only weak (GE vs. TomTec: SRSsept: 0.470, SSI: 0.467) (Philips vs. QLAB: SRSsept: 0.419, SSI: 0.421). Comparability of septal strain patterns was low (Cohen’s kappa, GE vs. TomTec: 0.221 and Philips vs. TomTec: 0.279). Septal strain patterns, SRSsept and SSI were associated with changes in LV end-systolic volume for all vendors. SRSsept and SSI had relative varying C-statistic values (range: 0.530–0.705) and different cut-off values between vendors. Conclusions Although global longitudinal strain analysis showed fair comparability, assessment of dyssynchrony parameters was vendor specific and not applicable outside the context of the implemented platform. While the standardization taskforce took an important step for global peak strain, further standardization of STE is still warranted.
Trajectories of Patient-Reported Health Status in Patients With an Implantable Cardioverter Defibrillator
To date, no study has assessed the course of patient-reported health status in patients with an implantable cardioverter defibrillator (ICD). Studying health status trajectories and their baseline determinants would permit the identification of patients at risk for poor health outcomes after ICD implantation. A combined cohort of 1,222 patients with an ICD (79% men; age = 61.4 [11.2] years) completed the 12-Item Short-Form Health Survey at baseline and 2 to 3 months and 12 to 14 months after implantation. Latent class analyses were used to identify trajectories and predictors of health status over time. Most health status trajectories showed a stable pattern after short-term follow-up, with differences between trajectories being mainly related to differences in absolute levels of health status. Seven trajectories were identified for physical health status. Being unemployed, symptomatic heart failure, ICD shock, psychotropic medication, negative affectivity, and type D personality were identified as independent determinants of poorer physical health status. For mental health status, 6 trajectories were identified. Younger age, low educational level, symptomatic heart failure, renal failure, no use of ACE inhibitors, psychotropic medication, negative affectivity, and type D personality were identified as independent determinants of poorer mental health status. In conclusion, the population with an ICD seems to be heterogeneous in terms of patient-reported physical and mental health status. Patients with an ICD who present with poor health status and a distressed personality profile should be timely identified and monitored as they may benefit from cardiac rehabilitation in combination with behavioral intervention.
Volumetric Response beyond Six Months of Cardiac Resynchronization Therapy and Clinical Outcome
Response to cardiac resynchronization therapy (CRT) is often assessed six months after implantation. Our objective was to assess the number of patients changing from responder to non-responder between six and 14 months, so-called late non-responders, and compare them to patients who were responder both at six and 14 months, so-called stable responders. Furthermore, we assessed predictive values of six and 14-month response concerning clinical outcome. 105 patients eligible for CRT were enrolled. Clinical, laboratory, ECG, and echocardiographic parameters and patient-reported health status (Kansas City Cardiomyopathy Questionnaire [KCCQ]) were assessed before, and six and 14 months after implantation. Response was defined as ≥15% LVESV decrease as compared to baseline. Major adverse cardiac events (MACE) were registered until 24 months after implantation. Predictive values of six and 14-month response for MACE were examined. In total, 75 (71%) patients were six-month responders of which 12 (16%) patients became late non-responder. At baseline, late non-responders more often had ischemic cardiomyopathy and atrial fibrillation, higher BNP and less dyssynchrony compared to stable responders. At six months, late non-responders showed significantly less LVESV decrease, and higher creatinine levels. Mean KCCQ scores of late non-responders were lower than those of stable responders at every time point, with the difference being significant at 14 months. The 14 months response was a better predictor of MACE than six months response. The assessment of treatment outcomes after six months of CRT could be premature and response rates beyond might better correlate to long-term clinical outcome.