Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
17 result(s) for "Minzioni, Paolo"
Sort by:
High-efficiency grating-couplers: demonstration of a new design strategy
We present a simple and practical strategy that allows to design high-efficiency grating couplers. The technique is based on the simultaneous apodization of two structural parameters: the grating period and the fill-factor, along with the optimization of the grating coupler etching depth. Considering a 260 nm Si-thick Silicon-on-insulator platform, we numerically demonstrated a coupling efficiency of −0.8 dB (83%), well matching the experimental value of −0.9 dB (81%). Thanks to the optimized design, these results represent the best performance ever reported in the literature for SOI structures without the use of any back-reflector.
Multi-frequency passive and active microrheology with optical tweezers
Optical tweezers have attracted significant attention for microrheological applications, due to the possibility of investigating viscoelastic properties in vivo which are strongly related to the health status and development of biological specimens. In order to use optical tweezers as a microrheological tool, an exact force calibration in the complex system under investigation is required. One of the most promising techniques for optical tweezers calibration in a viscoelastic medium is the so-called active–passive calibration, which allows determining both the trap stiffness and microrheological properties of the medium with the least a-priori knowledge in comparison to the other methods. In this manuscript, we develop an optimization of the active–passive calibration technique performed with a sample stage driving, whose implementation is more straightforward with respect to standard laser driving where two different laser beams are required. We performed microrheological measurements over a broad frequency range in a few seconds implementing an accurate multi-frequency driving of the sample stage. The optical tweezers-based microrheometer was first validated by measuring water, and then exemplarily applied to more viscous medium and subsequently to a viscoelastic solution of methylcellulose in water. The described method paves the way to microrheological precision metrology in biological samples with high temporal- and spatial-resolution allowing for investigation of even short time-scale phenomena.
Integrated Optofluidic Chip for Oscillatory Microrheology
We propose and demonstrate an on-chip optofluidic device allowing active oscillatory microrheological measurements with sub- μ L sample volume, low cost and high flexibility. Thanks to the use of this optofluidic microrheometer it is possible to measure the viscoelastic properties of complex fluids in the frequency range 0.01–10 Hz at different temperatures. The system is based on the optical forces exerted on a microbead by two counterpropagating infrared laser beams. The core elements of the optical part, integrated waveguides and an optical modulator, are fabricated by fs-laser writing on a glass substrate. The system performance is validated by measuring viscoelastic solutions of aqueous worm-like micelles composed by Cetylpyridinium Chloride (CPyCl) and Sodium Salicylate (NaSal).
Association of Indocyanine Green with Chitosan Oleate Coated PLGA Nanoparticles for Photodynamic Therapy
Indocyanine green (ICG) is a safe dye widely used in the biomedical field. Its photodynamic effect (PDT), originating from laser irradiation at 803 nm, opens interesting perspectives in theranostic applications. To overcome its low water stability, ICG can be shielded with nanoparticles (NPs). In this work, previously developed NPs based on poly lactic-co-glycolic acid (PLGA) coated with chitosan oleate (CS-OA) and loaded with resveratrol as a hydrophobic model drug have been proposed as an ICG carrier. These systems have been selected for their observed immunostimulatory properties. The possible loading of the dye by adsorption onto NP surface by electrostatic interaction was studied here in comparison with the encapsulation into the PLGA core. The ICG-chitosan (CS) interaction has been characterized by spectrophotometry, spectroscopy and in-cell in vitro assays. Fluorescence quenching was observed due to the ionic interaction between ICG and CS and was studied considering the dye:polymer stoichiometry and the effect of the NP dilution in cell culture medium (DMEM). The NP systems have been compared in vitro, assessing their behaviour in Caco-2 cell lines. A reduction in cell viability was observed after irradiation of ICG associated with NPs, evident also for the samples loaded by adsorption. These findings open the opportunity to exploit the association of PDT’s effect on ICG with the properties of CS-OA coated NPs, whose immunostimulatory effect can be associated with PDT mechanism in cancer therapy.
Numerical and Experimental Study of Optoelectronic Trapping on Iron-Doped Lithium Niobate Substrate
Optoelectronic tweezers (OET) are a promising technique for the realization of reconfigurable systems suitable to trap and manipulate microparticles. In particular, dielectrophoretic (DEP) forces produced by OET represent a valid alternative to micro-fabricated metal electrodes, as strong and spatially reconfigurable electrical fields can be induced in a photoconductive layer by means of light-driven phenomena. In this paper we report, and compare with the experimental data, the results obtained by analyzing the spatial configurations of the DEP-forces produced by a 532 nm laser beam, with Gaussian intensity distribution, impinging on a Fe-doped Lithium Niobate substrate. Furthermore, we also present a promising preliminary result for water-droplets trapping, which could open the way to the application of this technique to biological samples manipulation.
Emergency medicine residents in the war zone: organizing humanitarian expeditions to train healthcare personnel during the conflict in Ukraine
Dear Editor,When faced with a crisis, particularly when it involves humanitarian aid, emergency medicine (EM) practitioners push themselves to question, “How can we help?” and “To the best of our knowledge and skills, what can we truly do?”. The mindset of EM personnel is presumably one of \"How can I help in these situations?\" and, more crucially, \"How can I help the most effectively?\". To answer these questions, we present our experience in Ukraine. [...]
Low-Loss Micro-Resonator Filters Fabricated in Silicon by CMOS-Compatible Lithographic Techniques: Design and Characterization
Optical resonators are fundamental building-blocks for the development of Si-photonics-integrated circuits, as tunable on-chip optical filters. In addition to the specific spectral shape, which may vary according to a particular application, extremely low losses from these devices are a crucial requirement. In the current state-of-the-art devices, most low-loss filters have only been demonstrated by exploiting ad hoc lithographic and etching techniques, which are not compatible with the standard CMOS (complementary metal-oxide semiconductor) process-flow available at Si-photonic foundries. In this paper, we describe the design and optimization of optical micro-resonators, based on Si-waveguides with a height lower than the standard ones (i.e., less than 220 nm), prepared on SOI (silicon on insulator) platform, which allow the realization of high-performance optical filters with an insertion loss lower than 1 dB, using only previously validated lithographic etch-depths.
Integrated Optofluidic Chip for Low-Volume Fluid Viscosity Measurement
In the present work, an integrated optofluidic chip for fluid viscosity measurements in the range from 1 mPa·s to 100 mPa·s is proposed. The device allows the use of small sample volumes (<1 µL) and the measurement of viscosity as a function of temperature. Thanks to the precise control of the force exerted on dielectric spheres by optical beams, the viscosity of fluids is assessed by comparing the experimentally observed movement of dielectric beads produced by the optical forces with that expected by numerical calculations. The chip and the developed technique are validated by analyzing several fluids, such as Milli-Q water, ethanol and water–glycerol mixtures. The results show a good agreement between the experimental values and those reported in the literature. The extremely reduced volume of the sample required and the high flexibility of this technique make it a good candidate for measuring a wide range of viscosity values as well as for the analysis of nonlinear viscosity in complex fluids.
Acoustofluidic separation: impact of microfluidic system design and of sample properties
We describe the results of a numerical study about the separation of fluid-suspended microsamples (as microbeads and cells) by acoustophoresis. A microfluidic channel with rectangular cross section is considered, and we investigate the impact on particle separation of many different parameters, dividing them in two groups: sample’s intrinsic factors (own properties of the sample) and extrinsic factors (related to the microfluidic system design and operation). Differently from what is usually done, we include in our study the impact of the initial sample position, which always has a certain variability in real experiments, and we introduce several new parameters allowing to assess system performance and to optimize the microchip separation efficiency. The obtained results show the importance of two design parameters that are generally overlooked: the channel width and the offset between the channel border and the input of the target samples in the microchannel. Additionally, the analysis method we describe and the new parameters we introduce to study the system can be beneficially used in almost any study of acoustophoretic-based separation system.
Femtosecond laser fabrication of optofluidic devices for single cell manipulation
In this work we fabricate and validate two optofludic devices for the manipulation and analysis of single cells. The chips are fabricated by femtosecond laser micromachining exploiting the 3D capabilities of the technique and the inherent perfect alignment between microfluidic channels and optical networks. Both devices have been validated by probing the mechanical properties of different cancer cell lines, which are expected to show different elasticity because of their different metastatic potential.