Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
16
result(s) for
"Mohr, Konstantin"
Sort by:
On the performance of wavelength meters: Part 2—frequency-comb based characterization for more accurate absolute wavelength determinations
2020
Wavelength meters are widely used for frequency determinations and stabilization purposes since they cover a large wavelength range, provide a high read-out rate and have specified accuracies of up to
10
-
8
. More accurate optical frequency measurements can be achieved with frequency combs but only at the price of considerably higher costs and complexity. In the context of precise and accurate frequency determinations for high-resolution laser spectroscopy, the performance of five different wavelength meters was quantified with respect to a frequency comb. The relative precision as well as the absolute accuracy has been investigated in detail, allowing us to give a sophisticated uncertainty margin for the individual instruments. We encountered a prominent substructure on the deviation between both device types with an amplitude of a few MHz that is repeating on the GHz scale. This finally limits the precision of laser scans which are monitored and controlled with wavelength meters. While quantifying its uncertainty margins, we found a high temporal stability in the characteristics of the wavelength meters which enables the preparation of wavelength-dependent adjustment curves for wide- and short-ranged scans. With this method, the absolute accuracy of wavelength meters can be raised up to the MHz level independently from the wavelength of the reference laser used for calibrating the device. Since this technique can be universally applied, it can lead to benefits in all fields of wavelength meter applications.
Journal Article
Collinear Laser Spectroscopy of Helium-like 11B3
by
Horst, Max
,
König, Kristian
,
Andelkovic, Zoran
in
Boron
,
collinear laser spectroscopy
,
Electron beams
2023
Collinear laser spectroscopy in the 1s2s3S1→1s2p3P0,2 transitions of helium-like 11B3+ was performed using the HITRAP beamline at the GSI Helmholtz Centre. The ions were produced in an electron beam ion source, extracted, and accelerated to a beam energy of 4 keV/q. Results agree with previous measurements within uncertainty. Thus, it was demonstrated that the metastable state in He-like ions is sufficiently populated to carry out collinear laser spectroscopy. The measurement is a pilot experiment for a series of measurements that will be performed at a dedicated collinear laser spectroscopy setup at TU Darmstadt with light helium-like ions.
Journal Article
Storage-ring laser spectroscopy of accelerator-produced hydrogen-like 208Bi82
by
Müller, Patrick
,
Imgram, Phillip
,
Ratajczyk, Tim
in
639/766/36/1121
,
639/766/36/1122
,
639/766/387/1126
2025
Quantum electrodynamics has been tested to accuracies below the parts-per-trillion level in light-mass systems. However, tests in heavy-mass systems with a large nuclear charge have not yet reached similar accuracy. Here we report the hyperfine-structure splitting in the 1
s
ground state of radioactive hydrogen-like
208
Bi
82+
. We produced the isotope in a nuclear reaction and injected the beam into a storage ring to perform laser spectroscopy on samples of 10
5
ions of Bi
82+
that have only a single remaining electron, which experiences extreme magnetic-field strengths. Our result for the hyperfine splitting is in excellent agreement with the most accurate prediction based on a combination of quantum electrodynamics calculations with an empirical treatment of the hyperfine-structure anomaly ratio extracted from laser spectroscopy on neutral atoms of
209
Bi and
208
Bi. This achievement paves the way for the most stringent test of quantum electrodynamics in strong magnetic fields and demonstrates the feasibility of laser spectroscopy on other exotic ions with low production yields.
Hyperfine splitting was measured using the laser spectroscopy of accelerator-produced hydrogen-like bismuth ions. This demonstrates the feasibility of such measurements with other exotic ions with low production yields in a storage ring.
Journal Article
X-ray dark-field imaging of the human lung—A feasibility study on a deceased body
2018
Disorders of the lungs such as chronic obstructive pulmonary disease (COPD) are a major cause of chronic morbidity and mortality and the third leading cause of death in the world. The absence of sensitive diagnostic tests for early disease stages of COPD results in under-diagnosis of this treatable disease in an estimated 60-85% of the patients. In recent years a grating-based approach to X-ray dark-field contrast imaging has shown to be very sensitive for the detection and quantification of pulmonary emphysema in small animal models. However, translation of this technique to imaging systems suitable for humans remains challenging and has not yet been reported. In this manuscript, we present the first X-ray dark-field images of in-situ human lungs in a deceased body, demonstrating the feasibility of X-ray dark-field chest radiography on a human scale. Results were correlated with findings of computed tomography imaging and autopsy. The performance of the experimental radiography setup allows acquisition of multi-contrast chest X-ray images within clinical boundary conditions, including radiation dose. Upcoming clinical studies will have to demonstrate that this technology has the potential to improve early diagnosis of COPD and pulmonary diseases in general.
Journal Article
In-vivo X-ray Dark-Field Chest Radiography of a Pig
by
Gromann, Lukas B.
,
Herzen, Julia
,
De Marco, Fabio
in
639/624/1107/510
,
639/766/930/2735
,
692/308/2778
2017
X-ray chest radiography is an inexpensive and broadly available tool for initial assessment of the lung in clinical routine, but typically lacks diagnostic sensitivity for detection of pulmonary diseases in their early stages. Recent X-ray dark-field (XDF) imaging studies on mice have shown significant improvements in imaging-based lung diagnostics. Especially in the case of early diagnosis of chronic obstructive pulmonary disease (COPD), XDF imaging clearly outperforms conventional radiography. However, a translation of this technique towards the investigation of larger mammals and finally humans has not yet been achieved. In this letter, we present the first
in
-
vivo
XDF full-field chest radiographs (32 × 35 cm
2
) of a living pig, acquired with clinically compatible parameters (40 s scan time, approx. 80 µSv dose). For imaging, we developed a novel high-energy XDF system that overcomes the limitations of currently established setups. Our XDF radiographs yield sufficiently high image quality to enable radiographic evaluation of the lungs. We consider this a milestone in the bench-to-bedside translation of XDF imaging and expect XDF imaging to become an invaluable tool in clinical practice, both as a general chest X-ray modality and as a dedicated tool for high-risk patients affected by smoking, industrial work and indoor cooking.
Journal Article
Surface structure analysis using visual high-resolution in situ process monitoring in laser powder bed fusion
by
Poka, Konstantin
,
Schmidt, Jonathan
,
Mohr, Gunther
in
Artificial intelligence
,
Chemistry and Materials Science
,
Cubes
2025
Parameter studies are a common step in selecting process parameters for laser powder bed fusion of metals (PBF-LB/M). Density cubes are commonly used for this purpose. Density cubes manufactured with varied process parameters can exhibit distinguishable surface structures visible to the human eye. The layer-wise process enables such surface structures to be detected during manufacturing. However, industrial visual in situ monitoring systems for PBF-LB/M currently have limited resolution and are incapable of reliably capturing small differences in the surface structures. In this work, a 65 MPixel high-resolution monochrome camera was integrated into an industrial PBF-LB/M machine together with a high-intensity LED (light-emitting diode) bar. Post-exposure images were taken to analyse differences in light reflection of fused areas. It is revealed that the grey-level co-occurrence matrix can be used to quantify the visual surface structure of nickel-based superalloy Inconel®939 density cubes per layer. The properties of the grey-level co-occurrence matrix correlate to the energy input and the resulting porosity of density cubes. Low-energy samples containing lack of fusion flaws show an increased contrast in the grey-level co-occurrence matrix compared to specimens with optimal energy input. The potential of high-resolution images for quality assurance via in situ process monitoring in PBF-LB/M is further discussed.
Journal Article
Process Induced Preheating in Laser Powder Bed Fusion Monitored by Thermography and Its Influence on the Microstructure of 316L Stainless Steel Parts
by
Sommer, Konstantin
,
Recknagel, Sebastian
,
Altenburg, Simon J.
in
Accumulation
,
additive manufacturing
,
Chemical analysis
2021
Undetected and undesired microstructural variations in components produced by laser powder bed fusion are a major challenge, especially for safety-critical components. In this study, an in-depth analysis of the microstructural features of 316L specimens produced by laser powder bed fusion at different levels of volumetric energy density and different levels of inter layer time is reported. The study has been conducted on specimens with an application relevant build height (>100 mm). Furthermore, the evolution of the intrinsic preheating temperature during the build-up of specimens was monitored using a thermographic in-situ monitoring set-up. By applying recently determined emissivity values of 316L powder layers, real temperatures could be quantified. Heat accumulation led to preheating temperatures of up to about 600 °C. Significant differences in the preheating temperatures were discussed with respect to the individual process parameter combinations, including the build height. A strong effect of the inter layer time on the heat accumulation was observed. A shorter inter layer time resulted in an increase of the preheating temperature by more than a factor of 2 in the upper part of the specimens compared to longer inter layer times. This, in turn, resulted in heterogeneity of the microstructure and differences in material properties within individual specimens. The resulting differences in the microstructure were analyzed using electron back scatter diffraction and scanning electron microscopy. Results from chemical analysis as well as electron back scatter diffraction measurements indicated stable conditions in terms of chemical alloy composition and austenite phase content for the used set of parameter combinations. However, an increase of the average grain size by more than a factor of 2.5 could be revealed within individual specimens. Additionally, differences in feature size of the solidification cellular substructure were examined and a trend of increasing cell sizes was observed. This trend was attributed to differences in solidification rate and thermal gradients induced by differences in scanning velocity and preheating temperature. A change of the thermal history due to intrinsic preheating could be identified as the main cause of this heterogeneity. It was induced by critical combinations of the energy input and differences in heat transfer conditions by variations of the inter layer time. The microstructural variations were directly correlated to differences in hardness.
Journal Article
Separation of the Formation Mechanisms of Residual Stresses in LPBF 316L
by
Sommer, Konstantin
,
Bruno, Giovanni
,
Altenburg, Simon J.
in
additive manufacturing
,
AISI 316L
,
Laser Powder Bed Fusion
2020
Rapid cooling rates and steep temperature gradients are characteristic of additively manufactured parts and important factors for the residual stress formation. This study examined the influence of heat accumulation on the distribution of residual stress in two prisms produced by Laser Powder Bed Fusion (LPBF) of austenitic stainless steel 316L. The layers of the prisms were exposed using two different border fill scan strategies: one scanned from the centre to the perimeter and the other from the perimeter to the centre. The goal was to reveal the effect of different heat inputs on samples featuring the same solidification shrinkage. Residual stress was characterised in one plane perpendicular to the building direction at the mid height using Neutron and Lab X-ray diffraction. Thermography data obtained during the build process were analysed in order to correlate the cooling rates and apparent surface temperatures with the residual stress results. Optical microscopy and micro computed tomography were used to correlate defect populations with the residual stress distribution. The two scanning strategies led to residual stress distributions that were typical for additively manufactured components: compressive stresses in the bulk and tensile stresses at the surface. However, due to the different heat accumulation, the maximum residual stress levels differed. We concluded that solidification shrinkage plays a major role in determining the shape of the residual stress distribution, while the temperature gradient mechanism appears to determine the magnitude of peak residual stresses.
Journal Article
Inter-individual variance and cardiac cycle dependency of aortic root dimensions and shape as assessed by ECG-gated multi-slice computed tomography in patients with severe aortic stenosis prior to transcatheter aortic valve implantation: is it crucial for correct sizing?
by
Walther, Thomas
,
Grothoff, Matthias
,
Rastan, Ardawan
in
Aged
,
Aged, 80 and over
,
Aortic Valve - diagnostic imaging
2013
To evaluate the inter-individual variance and the variability of the aortic root dimensions during the cardiac cycle by computed tomography (CT) in patients with severe aortic stenosis prior to transcatheter aortic valve implantation (TAVI). Fifty-six patients (m/w = 16/40, 81 ± 6.8 years), scheduled for a transapical aortic valve implantation with available preprocedural ECG-gated CT were retrospectively included. The evaluation included sizing of the aortic annulus and the aortic sinus, measurements of the coronary topography, aortic valve planimetry and scoring of calcification. The new defined aortic annulus sphericity ratio revealed a mostly elliptical shape with increasing diastolic deformation. The calculated effective diameter (ED), determined from the annulus’ lumen area, turned out to be the parameter least affected from cardiac cycle changes while systolic and diastolic annulus dimensions and shape (diameter and area) differed significantly (
p
< 0.001). In about 70 % of the patients with relevant paravalvular leaks the finally implanted prosthesis was too small according to the CT based calculated ED. The ostial height of the coronaries showed a high variability with a critical minimum range <5 mm. The degree of the aortic calcification did not have an influence on the aortic annulus deformation during the cardiac cycle, but on the occurrence of paravalvular leaks. The aortic root anatomy demonstrated a high inter-individual variability and cardiac cycle dependency. These results must be strongly considered during the patient evaluation prior to TAVI to avoid complications. The systolic effective diameter, as measured by ECG-gated CT, represents an appropriate parameter for sizing the aortic annulus.
Journal Article
Depiction of pneumothoraces in a large animal model using x-ray dark-field radiography
by
Gromann, Lukas B.
,
Ertl-Wagner, Birgit
,
Herzen, Julia
in
639/766/25
,
692/308/2778
,
Animal models
2018
The aim of this study was to assess the diagnostic value of x-ray dark-field radiography to detect pneumothoraces in a pig model. Eight pigs were imaged with an experimental grating-based large-animal dark-field scanner before and after induction of a unilateral pneumothorax. Image contrast-to-noise ratios between lung tissue and the air-filled pleural cavity were quantified for transmission and dark-field radiograms. The projected area in the object plane of the inflated lung was measured in dark-field images to quantify the collapse of lung parenchyma due to a pneumothorax. Means and standard deviations for lung sizes and signal intensities from dark-field and transmission images were tested for statistical significance using Student’s two-tailed
t
-test for paired samples. The contrast-to-noise ratio between the air-filled pleural space of lateral pneumothoraces and lung tissue was significantly higher in the dark-field (3.65 ± 0.9) than in the transmission images (1.13 ± 1.1;
p =
0.002). In case of dorsally located pneumothoraces, a significant decrease (−20.5%;
p
> 0.0001) in the projected area of inflated lung parenchyma was found after a pneumothorax was induced. Therefore, the detection of pneumothoraces in x-ray dark-field radiography was facilitated compared to transmission imaging in a large animal model.
Journal Article