Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
48 result(s) for "Momma, Daisuke"
Sort by:
Implications of navigation system use for glenoid component placement in reverse shoulder arthroplasty
Recently, three-dimensional (3D) planning, patient-specific instruments, and navigation system have been developed to improve the accuracy of baseplate placement in reverse shoulder arthroplasty (RSA). The purpose of this study was to evaluate baseplate placement using the navigation system. Sixty-four shoulders in 63 patients who underwent RSA for rotator cuff tear arthropathy or irreparable rotator cuff tears were enrolled. Conventional RSA was performed in 31 shoulders and navigated RSA using pre-operative planning software was performed in 33 shoulders. The use of augmented baseplates, the version and inclination of the baseplate, and screw length were compared between conventional RSA and navigated RSA. Augmented baseplates were used more frequently in navigated RSA than in conventional RSA (20 vs 9 shoulders, p = 0.014). Baseplate alignment was 1.0° (SD 5.1) of retroversion and 2.4° (SD 6.8) of superior inclination in conventional RSA and 0.2° (SD 1.9) of anteversion and 0.3° (SD 1.7) of superior inclination in navigated RSA. Compared with conventional RSA, precision of baseplate version and inclination were higher in navigated RSA (both p < 0.001). Superior, inferior, and posteroinferior screws were significantly longer in navigated RSA than in conventional RSA (p = 0.021, 0.001 and < 0.001, respectively). Precision of superior and inferior screw lengths was significantly higher in navigated RSA than in conventional RSA (both p = 0.001). Our results suggest that adoption of pre-operative planning software increased augmented baseplate use to minimize the glenoid reaming. The navigation system allows placement of the baseplate accurately, according to the pre-operative plan. Furthermore, the navigation system enables monitoring of screw length and direction in real time.
Articular cartilage corefucosylation regulates tissue resilience in osteoarthritis
This study aimed to investigate the glycan structural changes that occur before histological degeneration in osteoarthritis (OA) and to determine the mechanism by which these glycan conformational changes affect cartilage degeneration. An OA model was established in rabbits using mannosidase injection, which reduced high-mannose type N-glycans and led to cartilage degeneration. Further analysis of glycome in human OA cartilage identified specific corefucosylated N-glycan expression patterns. Inhibition of N-glycan corefucosylation in mice resulted in unrecoverable cartilage degeneration, while cartilage-specific blocking of corefucosylation led to accelerated development of aging-associated and instability-induced OA models. We conclude that α1,6 fucosyltransferase is required postnatally to prevent preosteoarthritic deterioration of articular cartilage. These findings provide a novel definition of early OA and identify glyco-phenotypes of OA cartilage, which may distinguish individuals at higher risk of progression.
Stress distribution pattern in the distal radioulnar joint before and after ulnar shortening osteotomy in patients with ulnar impaction syndrome
Ulnar shortening osteotomy (USO) for ulnar impaction syndrome potentially leads to degenerative changes of the distal radioulnar joint (DRUJ). This study was performed to evaluate the effect of the sigmoid notch morphology on the stress distribution pattern of the DRUJ using computed tomography (CT) osteoabsorptiometry (CT-OAM). We reviewed the pre- and postoperative transverse CT images of 15 wrists that had undergone USO. The examined wrists were classified into two groups based on the sigmoid notch morphology: the linear-type notch (type L) and the curved-type notch (type C). We calculated and statistically compared the percentage of the high-density area (%HDA) in each divided region of the sigmoid notch. In type L, %HDA was significantly larger in the distal-dorsal region of the sigmoid notch before USO. Postoperatively, in type L, no specific regions showed a significantly different %HDA. In type C, %HDA was significantly larger in the distal-volar region of the sigmoid notch before USO. Postoperatively, %HDA of type C was significantly larger in the proximal-volar region. Our results suggest that in patients with ulnar impaction syndrome, morphological evaluation of the sigmoid notch can serve as a predictor of osteoarthritis in the DRUJ with or without USO.
Four-dimensional computed tomography evaluation of shoulder joint motion in collegiate baseball pitchers
The purpose of this study is to evaluate the glenohumeral contact area, center of glenohumeral contact area, and center of humeral head during simulated pitching motion in collegiate baseball pitchers using four-dimensional computed tomography (4D CT). We obtained 4D CT data from the dominant and non-dominant shoulders of eight collegiate baseball pitchers during the cocking motion. CT image data of each joint were reconstructed using a 3D reconstruction software package. The glenohumeral contact area, center of glenohumeral contact area, center of humeral head, and oblateness of humeral head were calculated from 3D bone models using customized software. The center of glenohumeral contact area translated from anterior to posterior during maximum external rotation to maximum internal rotation (0.58 ± 0.63 mm on the dominant side and 0.99 ± 0.82 mm on the non-dominant side). The center of humeral head translated from posterior to anterior during maximum external rotation to maximum internal rotation (0.76 ± 0.75 mm on the dominant side and 1.21 ± 0.78 mm on the non-dominant side). The increase in anterior translation of the center of glenohumeral contact area was associated with the increase in posterior translation of the center of humeral head. Also, the increase in translation of the center of humeral head and glenohumeral contact area were associated with the increase in oblateness of the humeral head. 4D CT analyses demonstrated that the center of humeral head translated in the opposite direction to that of the center of glenohumeral contact area during external rotation to internal rotation in abduction in the dominant and non-dominant shoulders. The oblateness of the humeral head may cause this diametric translation. 4D CT scanning and the software for bone surface modeling of the glenohumeral joint enabled quantitative assessment of glenohumeral micromotion and be used for kinematic evaluation of throwing athletes.
Changes in elbow joint contact area in symptomatic valgus instability of the elbow in baseball players
The aim of this study was to evaluate the joint contact area of the dominant side and that of the non-dominant side without valgus instability in symptomatic pitchers. Ten symptomatic elbow medial ulnar collateral ligament (UCL) deficient baseball pitchers participated in this study. Computed tomography (CT) data from the dominant and non-dominant elbows were obtained with and without elbow valgus stress. The CT imaging data of each elbow joint were reconstructed using a 3D reconstruction software package, and the radiocapitellar and ulnohumeral joint contact areas were calculated. The center of the contact area and the translation from the position without stress to the position with valgus stress were also calculated. With elbow valgus stress, the contact area changed, and the center of the radiocapitellar joint contact area translated significantly more laterally in the dominant elbow than in the non-dominant elbow (p = 0.0361). In addition, the center of the ulnohumeral joint contact area translated significantly more posteriorly in the dominant elbow than in the non-dominant elbow (p = 0.0413). These changes in contact areas could be the reason for cartilage injury at the posterior trochlea in pitchers with UCL deficiency.
Effect of the Sauvé–Kapandji method on the wrist contact surface for distal radial ulnar joint disorders
Background The Sauvé–Kapandji (S-K) method is a surgical procedure performed for chronic deformities of the distal radial ulnar joint (DRUJ). Changes to the joint contact surface from pre- to postoperatively under physiological in vivo conditions have not yet been determined for this useful treatment. The aim of the present study was therefore to compare the articular contact area of the wrist joint between before and after the S-K method for DRUJ disorders. Methods The SK method was performed for 15 patients with DRUJ osteoarthritis and ulnar impaction syndrome. We calculated the Mayo Wrist Score as the patient’s clinical findings and created 3-dimensional bone models of cases in which the S-K method was performed and calculated the contact area and shift in the center of the contact area using customized software. Results The Mean modified Mayo Wrist Score improved significantly from 60.3 preoperatively to 80.3 postoperatively ( P  < 0.01). Scaphoid contact area to the radius increased significantly from 112.6 ± 37.0 mm 2 preoperatively to 127.5 ± 27.8 mm 2 postoperatively ( P  = 0.03). Lunate contact area to radius-ulna was 121.3 ± 43.3 mm 2 preoperatively and 112.5 ± 37.6 mm 2 postoperatively, but this decrease was not significant ( P  = 0.38). Contact area ratio of scaphoid to lunate increased significantly from 1.01 ± 0.4 preoperatively to 1.20 ± 0.3 postoperatively ( P  = 0.02). Postoperative translations of the center of the scaphoid and lunate contact areas were decomposed into ulnar and proximal directions. Ulnar and proximal translation distances of the scaphoid contact area were 0.8 ± 1.7 mm and 0.4 ± 0.6 mm, respectively, and those of the lunate contact area were 1.1 ± 1.7 mm and 0.4 ± 1.1 mm, respectively. This study revealed changes in wrist contact area and center of the contact area before and after the S-K method. Conclusion These results may accurately indicate changes in wrist joint contact area from pre- to postoperatively using the S-K method for patients with DRUJ disorder. Evaluation of changes in contact area due to bone surface modeling of the wrist joint using 3DCT images may be useful in considering surgical methods.
Changes in wrist joint contact area following radial shortening osteotomy for Kienböck’s disease
We hypothesized that the contact area of the articular surface of the wrist joint could be evaluated using a custom-designed analytical program. The aim of the study was to compare the articular contact area of the wrist joint before and after radial shortening osteotomy for Kienböck’s disease. Nine wrists of 9 patients underwent radial shortening osteotomy for Kienböck’s disease. Computed tomography (CT) images of the wrist joint were reconstructed using a 3D reconstruction software package. Radioscaphoid and radiolunate joint contact areas and translation of the joint contact area from preoperative to postoperative were calculated using customized software. The mean Modified Mayo Wrist Score was significantly improved from 50.6 preoperatively to 83.3 at final follow-up (p < .001). Preoperatively, the pain was reported as severe in five wrists and moderate in four wrists, while at final follow-up, five patients were free from pain and four patients had mild pain with vigorous activity. The preoperative radioscaphoid joint contact area was 133.4 ± 49.5 mm 2 and the postoperative radioscaphoid joint contact area was 156.4 ± 73.1 mm 2 . The preoperative radiolunate joint contact area was 194.8 ± 92.1 mm 2 and the postoperative radiolunate joint contact area was 148.3 ± 97.9 mm 2 . The radial translation distance was 0.4 ± 1.2 mm, the dorsal translation distance was 0.6 ± 1.2 mm, and the proximal translation distance was 0.2 ± 0.4 mm. CT-based analysis revealed that the center of the contact area translated radially following radial shortening.
Progressive subchondral bone cyst formation following autologous chondrocyte implantation with all-suture anchors: a Case Report with histological evaluation
Background Subchondral bone cysts (SBCs) can significantly impact the outcomes of cartilage repair procedures such as autologous chondrocyte implantation (ACI). However, the etiology and progression of SBCs following ACI remain poorly understood. This case report highlights a progressively enlarging SBC following ACI using all-suture anchors, treated with autologous osteochondral transplantation (AOT). Case presentation A 58-year-old female with progressive right knee pain, varus alignment, and Kellgren-Lawrence grade 3 osteoarthritis underwent atelocollagen-associated ACI combined with medial opening wedge high tibial osteotomy. Longitudinal radiological assessment revealed bone hole enlargement corresponding to all-suture anchor sites, with one hole continuing to expand up to 15 months postoperatively, reaching a size of 11 × 13 × 13 mm. This expanding SBC exhibited a connection to the joint cavity via a tiny fissure, scant osteosclerotic rim on CT, and fluid intensity on MRI. Histological analysis of tissue obtained during subsequent AOT revealed several findings. The SBC was located at the anterior portion of the medial femoral condyle, just beneath the all-suture anchor. Osteochondral necrosis was observed surrounding the anchor site, with no evidence of foreign body reaction. The cyst was filled with a mucoid substance and featured an aggregation of foamy macrophages. A sclerotic wall indicative of a strain response was observed. Notably, the presence of osteoclasts along the adjacent bone surface indicated ongoing bone resorption. The patient underwent AOT, which resulted in confirmed bone union. Postoperative follow-up demonstrated successful integration of the osteochondral graft and improved knee function scores over three years. Conclusion This case report documents SBC formation following knee surgery with all-suture anchors and provides histological evaluation of such a cyst. The observed histological findings may contribute to our understanding of SBC pathophysiology in the context of cartilage repair procedures. This case underscores the importance of secure suturing techniques in high-stress areas and suggests the potential benefit of extended post-operative monitoring of SBC progression beyond one year. These observations may inform future strategies for the early detection of SBC formation and its progression, as well as timely intervention to prevent further joint damage in similar cases, though further research is needed to establish broader clinical implications.
CCL21/CCR7 axis regulating juvenile cartilage repair can enhance cartilage healing in adults
Juvenile tissue healing is capable of extensive scarless healing that is distinct from the scar-forming process of the adult healing response. Although many growth factors can be found in the juvenile healing process, the molecular mechanisms of juvenile tissue healing are poorly understood. Here we show that juvenile mice deficient in the chemokine receptor CCR7 exhibit diminished large-scale healing potential, whereas CCR7-depleted adult mice undergo normal scar-forming healing similar to wild type mice. In addition, the CCR7 ligand CCL21 was transiently expressed around damaged cartilage in juvenile mice, whereas it is rarely expressed in adults. Notably, exogenous CCL21 administration to adults decreased scar-forming healing and enhanced hyaline-cartilage repair in rabbit osteochondral defects. Our data indicate that the CCL21/CCR7 axis may play a role in the molecular control mechanism of juvenile cartilage repair, raising the possibility that agents modulating the production of CCL21 in vivo can improve the quality of cartilage repair in adults. Such a strategy may prevent post-traumatic arthritis by mimicking the self-repair in juvenile individuals.
Optimal administration frequency and dose of teriparatide for acceleration of biomechanical healing of long-bone fracture in a mouse model
Despite preclinical studies demonstrating the effectiveness of teriparatide for skeletal repair in small animals, inconclusive data from clinical trials have raised questions regarding the optimal teriparatide dosing regimen for bone repair. To address this, we assessed the effect of teriparatide frequency and dose on long-bone healing using a mouse femur osteotomy/fracture model. Eight-week-old male ICR mice were subjected to open femur osteotomies, then randomized into following five groups (n = 8 per group): vehicle; low dose/high frequency: 3 μg/kg/dose, 3 times/day; low dose/low frequency: 9 μg/kg/dose, 1 time/day; high dose/high frequency: 9 μg/kg/dose, 3 times/day; high dose/low frequency: 27 μg/kg/dose, 1 time/day. Skeletal repair was assessed by microcomputed tomography, mechanical testing, and histology 4 weeks after surgery. High-dose and/or high-frequency teriparatide treatment increased callus bone volume but failed to have a significant impact on the biomechanical recovery of fractured femurs, possibly because of impaired cortical shell formation in fracture calluses. Meanwhile, low-dose/low-frequency teriparatide therapy enhanced callus bone formation without interfering with cortical shell formation despite a lesser increase in callus bone volume, leading to significant two and fourfold increases in ultimate load and stiffness, respectively. Our findings demonstrate that administering teriparatide at higher doses and/or higher frequencies raises fracture callus volume but does not always accelerate the biomechanical recovery of fractured bone, which points to the importance of finding the optimal teriparatide dosing regimen for accelerating skeletal repair.