Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
357
result(s) for
"Moon, Kun"
Sort by:
Anatomic changes in asymptomatic pachychoroid spectrum diseases after cataract surgery
2024
Pachychoroid spectrum disease (PSD) involves various chorioretinal pathologies associated with increased choroidal blood flow. Theoretically, PSD could worsen after cataract surgery since the choroidal thickness tends to increase after surgery. Therefore, we evaluated the prevalence of asymptomatic PSD in patients who underwent cataract surgery and compared the clinical characteristics according to the presence of PSD. The subretinal fluid (SRF) development risk was evaluated using the Cox proportional hazard model. Of 924 eyes, 184 (19.9%) showed asymptomatic PSD. Patients with asymptomatic PSD were older, predominantly male, hyperopic, and showed thicker choroid (
P
< 0.001, 0.001, < 0.001, and < 0.001). Seven (3.8%) of 184 eyes with asymptomatic PSD developed SRF. The Cox proportional hazard model showed that the flat, irregular pigment epithelial detect (FI-PED; HR 37.337, 95% CI 3.880–359.9300,
P
= 0.002) was the sole indicator for the SRF development after adjustment of age, sex, and axial length. The SRF-developed PSD group experienced a profound and prolonged increase in the choroidal thickness (
P
= 0.001, 0.002, and 0.002 at 1, 3, and 12 months). Meticulous preoperative evaluation for FI-PED and postoperative monitoring for choroidal thickness would predict SRF development after cataract surgery in eyes with asymptomatic PSD.
Journal Article
Vertical implantable collamer lens as a novel method to increase rotational stability
2024
We investigated the vertical implantation of a toric implantable collamer lens (ICL) and compared the rotational stability with that of horizontal implantation.
This matched comparative study retrospectively reviewed and analyzed data from patients who underwent ICL implantation from 2003-2022 by 1:1 matching vertical and horizontal (V and H toric groups, respectively) implantation patients according to preoperative astigmatism, spherical equivalent, sulcus-to-sulcus, anterior chamber depth, and ICL size. Visual acuity, manifest refraction, vaulting, and rotation were measured 3 months postoperatively.
We included 646 eyes (323 each in the V and H toric groups). No statistically significant difference was observed between groups in postoperative visual acuity, refractive error, and astigmatism. Vaulting was lower in the V toric group. (P < 0.001). The mean lens rotation in the V toric group was less than that in the H toric group (1.11 ± 2.84° versus 3.02 ± 10.34°, P = 0.001). The proportion of eyes in the V and H toric groups showing ≥10° of rotation was 2.5% (8 eyes) and 6.5% (21 eyes), respectively (P = 0.014). Despite repositioning from rotation, three (0.9%) and eight (2.5%) eyes required removal owing to lens re-rotation in the V and H toric groups, respectively.
Toric ICL vertical implantation showed good rotational stability, and appropriate visual acuity correction results with relatively low vaulting. This procedure therefore presents an effective novel method that could replace horizontal toric ICL implantation.
Journal Article
Clinical outcomes of new multifocal intraocular lenses with hydroxyethyl methacrylate and comparative results of contrast sensitivity, objective scatter, and subjective photic phenomena
2022
Background
We investigate the performance of new hydrophobic diffractive multifocal intraocular lenses (IOL) with hydroxyethyl methacrylate (HEMA) and compare their optical quality, contrast sensitivity, and subjective photic phenomena.
Methods
Medical records of patients who underwent routine simple cataract surgery and insertion of an existing multifocal IOL (TFNT, TF group) or a new multifocal IOL (CNWT, CN group) were retrospectively reviewed. Clinical data was collected 2 months postoperatively and included optical quality analysis system (OQAS) indices, contrast sensitivity, and subjective degrees of photic phenomena.
Results
One hundred thirty-five eyes of 135 patients were included (CN group, 71; TF group, 64). There was no significant difference between the two groups in the visual acuity and defocus curve. The indices of OQAS did not show a significant difference between groups. Contrast sensitivity was significantly better in the CN group at all degrees, including the area under the log contrast sensitivity function (
p
= 0.01). The subjective photic phenomena survey showed better results for the CN group, with the proportion of patients reporting no photic phenomena as 9.9% and 3.1% in the CN and TF groups, respectively. The proportion of patients who reported severe photic phenomena was 11.3% in the CN group and 25.0% in the TF group. Although the follow-up period was only 2 months, glistening, surface scattering, and posterior capsule opacity were not observed in any patient.
Conclusions
The new multifocal IOL with HEMA is safe, and provides stable visual acuity as well as superior contrast sensitivity and lower subjective photic phenomena, over the prior IOL.
Journal Article
Diabetic Retinopathy and Endothelial Dysfunction in Patients with Type 2 Diabetes Mellitus
by
Yoo, Ki-Dong
,
Moon, Kun-Woong
,
Kim, Ji-Hoon
in
Antihypertensives
,
Blood pressure
,
Body mass index
2013
We investigated the relationship between endothelial dysfunction and diabetic retinopathy (DR) in patients with type 2 diabetes.
We used a cross-sectional design to examine 167 patients with type 2 diabetes mellitus. All patients underwent biochemical and ophthalmological examination. We assessed endothelial dysfunction by a flow-mediated vasodilation method of the brachial artery. Changes in vasodilation (flow-mediated vasodilatation, %FMD) were expressed as percent change over baseline values.
The mean±standard deviation of patient age was 54.1±8.6 years. The %FMD was significantly lower in patients with DR than without DR. The prevalence of retinopathy decreased across increasing tertiles of %FMD. After adjusting for patients' age, sex, diabetes duration, use of insulin, use of antihypertensive, antiplatelet, and lipid lowering medications, systolic blood pressure, fasting plasma glucose, 2-hour plasma glucose, glycated hemoglobin, and urinary albumin excretion, participants with a reduced %FMD were more likely to have DR (odds ratio, 11.819; 95% confidence interval, 2.201 to 63.461; P=0.004, comparing the lowest and highest tertiles of %FMD).
Endothelial dysfunction was associated with DR, which was most apparent when the endothelial dysfunction was severe. Our study provides insights into the possible mechanism of the influence of endothelial dysfunction on the development of DR.
Journal Article
Long-term Clinical Outcomes After Trifocal Intraocular Lens Implantation: A Retrospective Observational Study
2023
Purpose:
To evaluate the long-term stability of the AcrySof IQ PanOptix TFNT00 intraocular lens (IOL) (Alcon Laboratories, Inc).
Methods:
This was a retrospective review of 1,065 eyes (745 patients) who underwent implantation of a PanOptix IOL. A total of 296 eyes (mean age: 58.62 ± 5.63 years and preoperative refractive error: −0.68 ± 3.01 diopters [D]) met inclusion criteria for this study. The objective refraction, uncorrected distance and near visual acuity (UDVA and UNVA), and corrected distance visual acuity (CDVA) were evaluated at postoperative months 1, 2, 6, 12, 24, and 36.
Results:
The refractive error was −0.20 ± 0.36 D at 1 month, −0.20 ± 0.35 D at 2 months (P = .503), −0.10 ± 0.37 D at 6 months (P < .001), −0.02 ± 0.38 D at 12 months (P < .001), 0.00 ± 0.38 D at 24 months (P < .001), and 0.03 ± 0.39 D at 36 months (P < .001). Multivariate analysis showed long-term, independent associations for young age (beta = −0.122; P = .029) and changes in mean keratometry (beta = −0.413; P < .001). A greater refractive change was associated with a greater change in UNVA (r = 0.134; P = .026) but not with UDVA (r = −0.029; P = .631) or CDVA (r = −0.010; P = .875).
Conclusions:
Implantation of the PanOptix IOL yields stable clinical outcomes for visual acuity and refractive error for the first 3 years. A slight hyperopic shift, causing decreased near visual acuity, is anticipated for younger patients.
[J Refract Surg. 2023;39(4):236–241.]
Journal Article
Vertical implantable collamer lens as a novel method to increase rotational stability
2024
PurposeWe investigated the vertical implantation of a toric implantable collamer lens (ICL) and compared the rotational stability with that of horizontal implantation.MethodsThis matched comparative study retrospectively reviewed and analyzed data from patients who underwent ICL implantation from 2003-2022 by 1:1 matching vertical and horizontal (V and H toric groups, respectively) implantation patients according to preoperative astigmatism, spherical equivalent, sulcus-to-sulcus, anterior chamber depth, and ICL size. Visual acuity, manifest refraction, vaulting, and rotation were measured 3 months postoperatively.ResultsWe included 646 eyes (323 each in the V and H toric groups). No statistically significant difference was observed between groups in postoperative visual acuity, refractive error, and astigmatism. Vaulting was lower in the V toric group. (P < 0.001). The mean lens rotation in the V toric group was less than that in the H toric group (1.11 ± 2.84° versus 3.02 ± 10.34°, P = 0.001). The proportion of eyes in the V and H toric groups showing ≥10° of rotation was 2.5% (8 eyes) and 6.5% (21 eyes), respectively (P = 0.014). Despite repositioning from rotation, three (0.9%) and eight (2.5%) eyes required removal owing to lens re-rotation in the V and H toric groups, respectively.ConclusionToric ICL vertical implantation showed good rotational stability, and appropriate visual acuity correction results with relatively low vaulting. This procedure therefore presents an effective novel method that could replace horizontal toric ICL implantation.
Journal Article
Diabetic Retinopathy and Endothelial Dysfunction in Patients with Type 2 Diabetes Mellitus
2013
Background
We investigated the relationship between endothelial dysfunction and diabetic retinopathy (DR) in patients with type 2 diabetes.
Methods
We used a cross-sectional design to examine 167 patients with type 2 diabetes mellitus. All patients underwent biochemical and ophthalmological examination. We assessed endothelial dysfunction by a flow-mediated vasodilation method of the brachial artery. Changes in vasodilation (flow-mediated vasodilatation, %FMD) were expressed as percent change over baseline values.
Results
The mean±standard deviation of patient age was 54.1±8.6 years. The %FMD was significantly lower in patients with DR than without DR. The prevalence of retinopathy decreased across increasing tertiles of %FMD. After adjusting for patients' age, sex, diabetes duration, use of insulin, use of antihypertensive, antiplatelet, and lipid lowering medications, systolic blood pressure, fasting plasma glucose, 2-hour plasma glucose, glycated hemoglobin, and urinary albumin excretion, participants with a reduced %FMD were more likely to have DR (odds ratio, 11.819; 95% confidence interval, 2.201 to 63.461; P=0.004, comparing the lowest and highest tertiles of %FMD).
Conclusion
Endothelial dysfunction was associated with DR, which was most apparent when the endothelial dysfunction was severe. Our study provides insights into the possible mechanism of the influence of endothelial dysfunction on the development of DR. Background
We investigated the relationship between endothelial dysfunction and diabetic retinopathy (DR) in patients with type 2 diabetes.
Methods
We used a cross-sectional design to examine 167 patients with type 2 diabetes mellitus. All patients underwent biochemical and ophthalmological examination. We assessed endothelial dysfunction by a flow-mediated vasodilation method of the brachial artery. Changes in vasodilation (flow-mediated vasodilatation, %FMD) were expressed as percent change over baseline values.
Results
The mean±standard deviation of patient age was 54.1±8.6 years. The %FMD was significantly lower in patients with DR than without DR. The prevalence of retinopathy decreased across increasing tertiles of %FMD. After adjusting for patients' age, sex, diabetes duration, use of insulin, use of antihypertensive, antiplatelet, and lipid lowering medications, systolic blood pressure, fasting plasma glucose, 2-hour plasma glucose, glycated hemoglobin, and urinary albumin excretion, participants with a reduced %FMD were more likely to have DR (odds ratio, 11.819; 95% confidence interval, 2.201 to 63.461; P=0.004, comparing the lowest and highest tertiles of %FMD).
Conclusion
Endothelial dysfunction was associated with DR, which was most apparent when the endothelial dysfunction was severe. Our study provides insights into the possible mechanism of the influence of endothelial dysfunction on the development of DR. KCI Citation Count: 0
Journal Article
Complications ; Diabetic Retinopathy and Endothelial Dysfunction in Patients with Type 2 Diabetes Mellitus
by
Yong Moon Park
,
Jae Seung Yun
,
Seung Hyun Ko
in
Diabetes mellitus
,
Diabetic retinopathy
,
Endothelial dysfunction
2013
Background: We investigated the relationship between endothelial dysfunction and diabetic retinopathy (DR) in patients with type 2 diabetes. Methods: We used a cross-sectional design to examine 167 patients with type 2 diabetes mellitus. All patients underwent biochemical and ophthalmological examination. We assessed endothelial dysfunction by a flow-mediated vasodilation method of the brachial artery. Changes in vasodilation (flow-mediated vasodilatation, %FMD) were expressed as percent change over baseline values. Results: The mean±standard deviation of patient age was 54.1±8.6 years. The %FMD was significantly lower in patients with DR than without DR. The prevalence of retinopathy decreased across increasing tertiles of %FMD. After adjusting for patients` age, sex, diabetes duration, use of insulin, use of antihypertensive, antiplatelet, and lipid lowering medications, systolic blood pressure, fasting plasma glucose, 2-hour plasma glucose, glycated hemoglobin, and urinary albumin excretion, participants with a reduced %FMD were more likely to have DR (odds ratio, 11.819; 95% confidence interval, 2.201 to 63.461; P=0.004, comparing the lowest and highest tertiles of %FMD). Conclusion: Endothelial dysfunction was associated with DR, which was most apparent when the endothelial dysfunction was severe. Our study provides insights into the possible mechanism of the influence of endothelial dysfunction on the development of DR.
Journal Article
An environment for understanding of legacy real-time software
1995
This dissertation describes an environment for understanding of large and complex legacy real-time software. Software understanding research combines analysis of legacy software and graphics-based man-machine interaction. The environment processes legacy software automatically first to create a repository, next to facilitate its understanding, and finally to create reusable components to facilitate modernizing software for the same or new application. The environment consists of the following components. (1) Legacy code representation: The legacy software is represented by a graphical language, called the Elementary Statement Language for Ada (ESL-Ada). The ESL-Ada statements and relations between the statements are represented as nodes and edges respectively. It is used as a basis for the understanding. (2) Concurrency representation: Concurrency in the legacy software, expressed in Operating System calls, are represented by Ada. The translation is accomplished by replacing the call with equivalent Ada code based on a message-based kernel oriented architecture. (3) Architecture discovery: The ESL-Ada, is partitioned into modules, called Software Units (SWUs). The SWUs are organized hierarchically based on parent-child relations. (4) State machine: The body of SWUs are represented by state machines, called Ada Real-time State Machine (ARSM). ARSM consists of states and transitions. ARSM preserves all real-time features of Ada. Each ARSM of a process (task) is a concurrently executable entity. ARSMs are hierarchically organized. (5) Simulation: The bodies of SWUs, represented by ARSMs, are simulated with test input. The outputs are obtained from the simulation. The output can be used to verify the correct execution behavior of SWUs. The graphical user interface to these components is supported by a meta graphic system, called DECDesign. This environment is the first comprehensive environment for analysis and understanding of large-scale legacy real-time software.
Dissertation