Colorimetric RT-LAMP SARS-CoV-2 diagnostic sensitivity relies on color interpretation and viral load
by
Marchini, Fabricio Klerynton
,
Nakaya, Helder I.
,
Aoki, Mateus Nóbrega
in
631/337
,
692/4017
,
Color
2021
The use of RT-LAMP (reverse transcriptase—loop mediated isothermal amplification) has been considered as a promising point-of-care method to diagnose COVID-19. In this manuscript we show that the RT-LAMP reaction has a sensitivity of only 200 RNA virus copies, with a color change from pink to yellow occurring in 100% of the 62 clinical samples tested positive by RT-qPCR. We also demonstrated that this reaction is 100% specific for SARS-CoV-2 after testing 57 clinical samples infected with dozens of different respiratory viruses and 74 individuals without any viral infection. Although the majority of manuscripts recently published using this technique describe only the presence of two-color states (pink = negative and yellow = positive), we verified by naked-eye and absorbance measurements that there is an evident third color cluster (orange), in general related to positive samples with low viral loads, but which cannot be defined as positive or negative by the naked eye. Orange colors should be repeated or tested by RT-qPCR to avoid a false diagnostic. RT-LAMP is therefore very reliable for samples with a RT-qPCR Ct < 30 being as sensitive and specific as a RT-qPCR test. All reactions were performed in 30 min at 65 °C. The use of reaction time longer than 30 min is also not recommended since nonspecific amplifications may cause false positives.
Journal Article
Serological diagnosis of fasciolosis (Fasciola hepatica) in humans, cattle, and sheep: a meta-analysis
by
Belo, Vínicius Silva
,
Rosa, Jaqueline de Oliveira
,
Drescher, Guilherme
in
Animals
,
Antibodies
,
Antigens
2023
Fasciola hepatica can cause problems in both animals and humans. Fasciolosis can be diagnosed through the indirect ELISA immunodiagnostic test. Serological diagnosis of Fasciola is based on recombinant antigens secreted by this worm. We used PubMed and Google Scholar databases to review the published literature on ‘antigens with immunogenic potential’ used in serological tests to identify antibodies against F. hepatica in humans, cattle, and sheep. Studies that investigated diagnostic tests with common reference standards were included in the sensitivity and/or specificity bivariate meta-analysis. In the quality and susceptibility to bias analysis of the 33 included studies, 26 fulfilled at least six (75%) of the eight QUADAS criteria and were considered good-quality papers. We found that most of the studies used native excretory-secretory antigens and recombinant cathepsin in ELISA tests for serological diagnosis of fascioliasis in humans, cattle, and sheep. The meta-analysis revealed that all antigens demonstrated good accuracy. The best results in terms of sensitivity [0.931–2.5% confidence interval (CI) and 0.985–97.5% CI] and specificity (0.959–2.5% CI and 0.997–97.5% CI) were found in human Fh ES. Fh rCL-1, Fh ES, and Fh rSAP-2 antigens gave the best results for the serum diagnosis of human and animal fasciolosis.
Journal Article
Modulation of Klebsiella pneumoniae Outer Membrane Vesicle Protein Cargo under Antibiotic Treatment
by
Alves, Lysangela Ronalte
,
Faoro, Helisson
,
Ferrarini, Mariana Galvão
in
Amikacin
,
antibiotic resistance
,
Antibiotics
2023
Klebsiella pneumoniae is a nosocomial pathogen and an important propagator of multidrug-resistant (MDR) and extensively drug-resistant (XDR) strains. Like other Gram-negative bacteria, they secrete outer membrane vesicles (OMVs) that distribute virulence and resistance factors. Here, we subjected a K. pneumoniae-XDR to subinhibitory concentrations of meropenem, amikacin, polymyxin B, and a combination of these agents to evaluate changes in the protein cargo of OMVs through liquid chromatography–tandem mass spectrometry (LC-MS/MS). Genome sequencing of the clinical isolate K. pneumoniae strain HCD1 (KpHCD1) revealed the presence of 41 resistance genes and 159 virulence factors. We identified 64 proteins in KpHCD1-OMVs modulated with different antibiotic treatments involved in processing genetic information, environmental information, cell envelope formation, energy metabolism, and drug resistance. The OMV proteome expression profile suggests that OMVs may be associated with pathogenicity, survival, stress response, and resistance dissemination.
Journal Article
A dataset for developing proteomic tools for pathogen detection via differential cell lysis of whole blood samples
by
Marchini, Fabricio Klerynton
,
Machado, Kelly Cavalcanti
,
Bandini, Thiago Bousquet
in
631/326
,
631/45/475
,
631/45/612
2024
This data descriptor presents a curated dataset for pathogen detection and identification (
Staphylococcus aureus
,
Pseudomonas aeruginosa
, and
Candida albicans
) directly from whole-blood samples. The dataset was created using differential cell lysis combined with rapid extraction, digestion, and mass spectrometry-based proteomics. Our method offers a rapid diagnostic alternative to traditional culture, enabling timely disease management, such as sepsis. Highlighting our dataset’s uniqueness, it features a three-tier structure: Spectral Libraries of Pathogens for identifying peptide peaks for putative biomarkers; Spiked pathogen in blood MS data for biomarker panel optimization through varied concentration samples; and Parallel Reaction Monitoring (PRM) data from sepsis patients for validating our biomarker panel, achieving 83.3% sensitivity within seven hours without microbial enrichment culture. This dataset serves as a comprehensive reference for bioinformatic tool development and biomarker panel proposals, advancing microbial detection, antimicrobial resistance, and epidemiological studies.
Journal Article
Validation of the NAT Chagas IVD Kit for the Detection and Quantification of Trypanosoma cruzi in Blood Samples of Patients with Chagas Disease
by
Jacomasso, Thiago
,
Moreira, Otacilio C.
,
dos Santos, Carolina Messias
in
Biomarkers
,
Blood
,
Chagas disease
2023
In the absence of validated biomarkers to control the cure of Chagas disease, PCR-based diagnosis is being used as the main tool for an early indication of therapeutic failure. However, since it is considered a technique of complex reproducibility, mainly due to difficulties in establishing accurate controls to guarantee the quality of the reaction, the use of PCR for Chagas disease diagnosis is restricted to specialized centers. In an effort to disseminate the molecular diagnosis of Chagas disease and its applications, new diagnostic kits based on qPCR have been made available in the market in recent years. Here, we show the results of the validation of the NAT Chagas kit (Nucleic Acid Test for Chagas Disease) for the detection and quantification of T. cruzi in blood samples of patients suspected of Chagas disease infection. The kit, composed of a TaqMan duplex reaction targeting the T. cruzi satellite nuclear DNA and an exogenous internal amplification control, presented a reportable range from 104 to 0.5 parasite equivalents/mL and a limit of detection (LOD) of 0.16 parasite equivalents/mL of blood. In addition, the NAT Chagas kit detected T. cruzi belonging to all six discrete typing units (DTUs—TcI to TcVI), similarly to the in-house real-time PCR performed with commercial reagents, which has been selected as the best performance assay in the international consensus for the validation of qPCR for Chagas disease. In the clinical validation presented here, the kit showed 100% sensitivity and 100% specificity when compared to the consensus in-house real-time PCR assay. Thus, the NAT Chagas kit, which is produced entirely in Brazil under the international standards of good manufacturing practices (GMP), appears as an excellent alternative to enable the molecular diagnosis of Chagas disease in public and private diagnostic centers, as well as to facilitate the monitoring of patients under etiological treatment participating in clinical trials.
Journal Article
Re-emergence of Gamma-like-II and emergence of Gamma-S:E661D SARS-CoV-2 lineages in the south of Brazil after the 2021 outbreak
by
Faoro, Helisson
,
Becker, Guilherme
,
Dallagiovanna, Bruno
in
Biomedical and Life Sciences
,
Biomedicine
,
Brazil
2021
Background
We report a genomic surveillance of SARS-CoV-2 lineages circulating in Paraná, southern Brazil, from March 2020 to April 2021. Our analysis, based on 333 genomes, revealed that the first variants detected in the state of Paraná in March 2020 were the B.1.1.33 and B.1.1.28 variants. The variants B.1.1.28 and B.1.1.33 were predominant throughout 2020 until the introduction of the variant P.2 in August 2020 and a variant of concern (VOC), Gamma (P.1), in January 2021. The VOC Gamma, a ramification of the B.1.1.28 lineage first detected in Manaus (northern Brazil), has grown rapidly since December 2020 and was thought to be responsible for the deadly second wave of COVID-19 throughout Brazil.
Methods
The 333 genomic sequences of SARS-CoV-2 from March 2020 to April 2021 were generated as part of the genomic surveillance carried out by Fiocruz in Brazil Genomahcov Fiocruz. SARS-CoV-2 sequencing was performed using representative samples from all geographic areas of Paraná. Phylogenetic analyses were performed using the 333 genomes also included other SARS-CoV-2 genomes from the state of Paraná and other states in Brazil that were deposited in the GISAID. In addition, the time-scaled phylogenetic tree was constructed with up to 3 random sequences of the Gamma variant from each state in Brazil in each month of 2021. In this analysis we also added the sequences identified as the B.1.1.28 lineage of the Amazonas state and and the Gamma-like-II (P.1-like-II) lineage identified in different regions of Brazil.
Results
Phylogenetic analyses of the SARS-CoV-2 genomes that were previously classified as the VOC Gamma lineage by WHO/PANGO showed that some genomes from February to April 2021 branched in a monophyletic clade and that these samples grouped together with genomes recently described with the lineage Gamma-like-II. Additionally, a new mutation (E661D) in the spike (S) protein has been identified in nearly 10% of the genomes classified as the VOC Gamma from Paraná in March and April 2021.Finally, we analyzed the correlation between the lineage and the Gamma variant frequency, age group (patients younger or older than 60 years old) and the clinical data of 86 cases from the state of Paraná.
Conclusions
Our results provided a reliable picture of the evolution of the SARS-CoV-2 pandemic in the state of Paraná characterized by the dominance of the Gamma strain, as well as a high frequencies of the Gamma-like-II lineage and the S:E661D mutation. Epidemiological and genomic surveillance efforts should be continued to unveil the biological relevance of the novel mutations detected in the VOC Gamma in Paraná.
Journal Article
Comprehensive Study of the IBMP ELISA IgA/IgM/IgG COVID-19 Kit for SARS-CoV-2 Antibody Detection
by
Vasconcelos, Larissa de Carvalho Medrado
,
Crestani, Sandra
,
Meireles, André Costa
in
Antibodies
,
Antigens
,
COVID-19
2024
COVID-19 laboratory diagnosis primarily relies on molecular tests, highly sensitive during early infection stages with high viral loads. As the disease progresses, sensitivity decreases, requiring antibody detection. Since the beginning of the pandemic, serological tests have been developed and made available in Brazil, but their diagnostic performance varies. This study evaluated the IBMP ELISA IgA/IgM/IgG COVID-19 kit performance in detecting SARS-CoV-2 antibodies. A total of 90 samples, including 64 from COVID-19 patients and 26 pre-pandemic donors, were assessed based on time post symptom onset (0–7, 8–14, and 15–21 days). The kit showed 61% sensitivity, 100% specificity, and 72% accuracy overall. Sensitivity varied with time, being 25%, 57%, and 96% for 0–7, 8–14, and 15–21 days, respectively. Similar variations were noted in other commercial tests. The Gold ELISA COVID-19 (IgG/IgM) had sensitivities of 31%, 71%, and 100%, while the Anti-SARS-CoV-2 NCP ELISA (IgG) and Anti-SARS-CoV-2 NCP ELISA (IgM) showed varying sensitivities. The IBMP ELISA kit displayed high diagnostic capability, especially as the disease progressed, complementing COVID-19 diagnosis. Reproducibility assessment revealed minimal systematic and analytical errors. In conclusion, the IBMP ELISA IgA/IgM/IgG COVID-19 kit is a robust tool for detecting anti-SARS-CoV-2 antibodies, increasing in efficacy over the disease course, and minimizing false negatives in RT-PCR COVID-19 diagnosis.
Journal Article
Peripheral ischemic reserve in sepsis and septic shock as a new bedside prognostic enrichment tool: A Brazilian cohort study
by
de Miranda, Ana Carolina
,
Assreuy, Jamil
,
De Stefani, Fernanda do Carmo
in
Biology and Life Sciences
,
Brazil
,
C-reactive protein
2023
Microvascular dysfunctions are associated with poor prognosis in sepsis. However, the potential role of clinical assessment of peripheral ischemic microvascular reserve (PIMR), a parameter that characterizes the variation of peripheral perfusion index (PPI) after brief ischemia of the upper arm, as a tool to detect sepsis-induced microvascular dysfunction and for prognostic enrichment has not been established. To address this gap, this study investigated the association of high PIMR with mortality over time in patients with sepsis and its subgroups (with and without shock) and peripheral perfusion (capillary-refill time). This observational cohort study enrolled consecutive septic patients in four Intensive-care units. After fluid resuscitation, PIMR was evaluated using the oximetry-derived PPI and post-occlusive reactive hyperemia for two consecutive days in septic patients. Two hundred and twenty-six patients were included—117 (52%) in the low PIMR group and 109 (48%) in the high PIMR group. The study revealed differences in mortality between groups on the first day, which was higher in the high PIMR group (RR 1.25; 95% CI 1.00–1.55; p = 0.04) and maintained its prognostic significance after multivariate adjustment. Subsequently, this analysis was made for sepsis subgroups and showed significant differences in mortality only for the septic-shock subgroup, with was higher in the high PIMR group (RR 2.14; 95% CI 1.49–3.08; p = 0.01). The temporal ΔPPI peak values (%) analyses did not demonstrate maintenance of the predictive value over the first 48 h in either group (p > 0.05). A moderate positive correlation (r = 0.41) between ΔPPI peak (%) and capillary-refill time (s) was found within the first 24 hours of diagnosis (p < 0.001). In conclusion, detecting a high PIMR within 24 h appears to be a prognostic marker for mortality in sepsis. Furthermore, its potential as a prognostic enrichment tool seems to occur mainly in septic shock.
Journal Article
A low-cost PCR instrument for molecular disease diagnostics based on customized printed circuit board heaters
by
Marchini, Fabricio Klerynton
,
de Oliveira Viviane Klassen
,
Aoki, Mateus Nóbrega
in
Algorithms
,
Aluminum
,
Circuit boards
2021
This article describes the fabrication of a low-cost Polymerase Chain Reaction (PCR) instrument to detect diseases. In order to reduce the instrument price and simplify construction we developed an alternative fabrication process, transforming conventional printed circuit boards (PCB) in heating elements, avoiding the use of aluminum heating/cooling blocks and Peltier devices. To cool down the reaction a simple computer fan was used. The vial holder was fabricated using two double side PCB boards assembled in a sandwich-like configuration. The bottom PCB has a resistance of 0.9 Ω used to heat the reaction mix, while the top layer has a resistance of 1.1 Ω to heat the vial body, preventing vapor condensation. The top board was maintained at ~ 110 ± 1 °C during all cycles. The final device was able to heat and cool down the reaction at rates of ~ 2.0 °C/s, a rate comparable to commercial thermocyclers. An SMD NTC thermistor was used as temperature sensors, and a PID (proportional–integral–derivative) control algorithm was implemented to acquire and precisely control the temperature. We also discuss how the instrument is calibrated. The device was tested successfully for the amplification of T. pallidum (Syphilis) bacterial DNA and Zika virus RNA samples, showing similar performance to a commercial PCR instrument.
Journal Article
Modulation of IKlebsiella pneumoniae/I Outer Membrane Vesicle Protein Cargo under Antibiotic Treatment
by
Alves, Lysangela Ronalte
,
Faoro, Helisson
,
Ferrarini, Mariana Galvão
in
Bacterial pneumonia
,
Drug resistance in microorganisms
,
Genomes
2023
Klebsiella pneumoniae is a nosocomial pathogen and an important propagator of multidrug-resistant (MDR) and extensively drug-resistant (XDR) strains. Like other Gram-negative bacteria, they secrete outer membrane vesicles (OMVs) that distribute virulence and resistance factors. Here, we subjected a K. pneumoniae-XDR to subinhibitory concentrations of meropenem, amikacin, polymyxin B, and a combination of these agents to evaluate changes in the protein cargo of OMVs through liquid chromatography-tandem mass spectrometry (LC-MS/MS). Genome sequencing of the clinical isolate K. pneumoniae strain HCD1 (KpHCD1) revealed the presence of 41 resistance genes and 159 virulence factors. We identified 64 proteins in KpHCD1-OMVs modulated with different antibiotic treatments involved in processing genetic information, environmental information, cell envelope formation, energy metabolism, and drug resistance. The OMV proteome expression profile suggests that OMVs may be associated with pathogenicity, survival, stress response, and resistance dissemination.
Journal Article