Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
14 result(s) for "Morera, Pierre"
Sort by:
Outcomes Following Aortic Stenosis Treatment (Transcatheter vs Surgical Replacement) in Women vs Men (From a Nationwide Analysis)
Gender-differences in survival following transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) have been suggested. The objective of this study was to analyze outcomes following TAVR according to gender and to compare outcomes between TAVR and SAVR in women, at a nationwide level. Based on the French administrative hospital-discharge database, the study collected information for all consecutive patients treated with TAVR and SAVR between 2010 and 2019. Outcomes were analyzed according to gender and propensity score matching was used for the analysis of outcomes. In total 71,794 patients were identified in the database. After matching on baseline characteristics, we analyzed 12,336 women and 12,336 men treated with TAVR. In a second matched analysis, we compared 9,297 women treated with TAVR and 9,297 women treated with SAVR. Long term follow-up showed lower risk of all-cause death (12.7% vs 14.8%, hazard ratio (HR) 0.85, 95% CI 0.81 to 0.90) in women than men. Although the difference in cardiovascular death remained non-significant (5.8% vs 6.0%, HR 0.96, 95% CI 0.88 to 1.05), non-cardiovascular death was less frequent in women than in men following TAVR (6.9% vs 8.8% HR 0.78, 95%CI 0.72 to 0.84).When TAVR was compared with SAVR in women, long-term follow-up with TAVR showed higher rates of all-cause death (11.2% vs 6.5%, HR 1.91, 95%CI 1.78 to 2.05), cardiovascular death (5.0% vs 3.2%, HR 1.44, 95%CI 1.30 to 1.59), and non-cardiovascular death (6.2% vs 3.3%, HR 2.48, 95% CI 2.25 to 2.72). In conclusion, we observed that women undergoing TAVR have lower long-term all-cause mortality as compared with TAVR in men, driven by non-cardiovascular mortality. SAVR was associated with lower rates of long-term cardiovascular adverse events in women as compared with TAVR.
Outcome of acute respiratory distress syndrome patients treated with extracorporeal membrane oxygenation and brought to a referral center
Purpose Patients with severe acute respiratory distress syndrome (ARDS) are candidates for extracorporeal membrane oxygenation (ECMO) therapy. The evaluation of organ severity is difficult in patients considered for cannulation in a distant hospital. This study was designed to identify early factors associated with hospital mortality in ARDS patients treated with ECMO and retrieved from referring hospitals. Methods Data from 85 consecutive ARDS patients equipped with ECMO by our mobile team and consequently admitted to our ICU were prospectively collected and analyzed. Results The main ARDS etiologies were community-acquired bacterial pneumonia (35 %), influenza pneumonia (23 %) (with 12 patients having been treated during the first half of the study period), and nosocomial pneumonia (14 %). The median (interquartile range) time between contact from the referring hospital and patient cannulation was 3 (1–4) h. ECMO was venovenous in 77 (91 %) patients. No complications occurred during transport by our mobile unit. Forty-eight patients died at the hospital (56 %). Based on a multivariate logistic regression, a score including age, SOFA score, and a diagnosis of influenza pneumonia was constructed. The probability of hospital mortality following ECMO initiation was 40 % in the 0–2 score class ( n  = 58) and 93 % in the 3–4 score class ( n  = 27). Patients with an influenza pneumonia diagnosis and a SOFA score before ECMO of less than 12 had a mortality rate of 22 %. Conclusions Age, SOFA score, and a diagnosis of influenza may be used to accurately evaluate the risk of death in ARDS patients considered for retrieval under ECMO from distant hospitals.
Prosthesis–Patient Mismatch in Small Aortic Annuli: Self-Expandable vs. Balloon-Expandable Transcatheter Aortic Valve Replacement
Prosthesis–patient mismatch (PPM) is associated with worse outcomes following surgical aortic valve replacement (SAVR). PPM has been identified in a significant proportion of TAVR, particularly in patients with small aortic annuli. Our objective was to evaluate the hemodynamic performances of balloon-expandable (BE) (Sapiens 3TM) versus two different self-expandable (SE) (Evolut ProTM, Accurate NeoTM) TAVR devices in patients with small aortic annulus defined by a computed tomography aortic annulus area (AAA) between 330 and 440 mm2. We enrolled 131 consecutive patients corresponding to 76 Sapiens 3 23 mm (58.0%), 26 Evolut Pro (19.9%) and 29 Accurate Neo (22.1%). Mean age was 82.5 ± 7.06 years, 22.9% of patients were male and mean Euroscore was 4.0%. Mean AAA was 374 ± 27 mm2 for Sapiens 3, 383 ± 29 mm2 for Corevalve Evolut Pro and 389 ± 25 mm2 for Accurate Neo. BE devices were associated with significantly higher rates of PPM (39.5%) as compared to SE devices (15.4% for Corevalve Evolut Pro and 6.9% for Accurate Neo) (p < 0.0001). Paravalvular leaks ≥ 2/4 were more often observed in SE devices (15.4% for Corevalve Evolut Pro and 17.2% for Accurate Neo) than in BE devices (2.6%) (p = 0.007). In conclusion, SE TAVR devices did achieve better hemodynamic results despite higher rates of paravalvular leaks. Therefore, SE TAVI devices could be considered as first choice in small aortic anatomy.
Reintervention of Residual Aortic Dissection after Type A Aortic Repair: Results of a Prospective Follow-Up at 5 Years
Background After a type A aortic dissection repair, a patent false lumen in the descending aorta is the most common situation encountered, and is a well-known risk factor for aortic growth, reinterventions and mortality. The aim of this study was to analyze the long-term results of residual aortic dissection (RAD) at a high-volume aortic center with prospective follow-up. Methods In this prospective single-center study, all patients operated for type A aortic dissection between January 2017 and December 2022 were included. Patients without postoperative computed tomography scans or during follow-up at our center, and patients without RAD were excluded. The primary endpoint was all-cause mortality during follow-up for patients with RAD. The secondary endpoints were perioperative mortality, rate of distal aneurysmal evolution, location of distal aneurysmal evolution, rate of distal reinterventions, outcomes of distal reinterventions, and aortic-related death during follow-up. Results In total, 200 survivors of RAD comprised the study group. After a mean follow-up of 27.2 months (1–66), eight patients (4.0%) died and 107 (53.5%) had an aneurysmal progression. The rate of distal reintervention was 19.5% (39/200), for malperfusion syndrome in seven cases (3.5%) and aneurysmal evolution in 32 cases (16.0%). Most reinterventions occurred during the first 2 years (82.1%). Twenty-seven patients were treated for an aneurysmal evolution of RAD including aortic arch with hybrid repair in 21 cases and branched aortic arch endoprosthesis in six cases. In the hybrid repair group, there was no death, and the rate of morbidity was 28.6% (6/21) (one minor stroke, one pulmonary complication, one recurrent paralysis with complete recovery and three major bleeding events). In the branched endograft group, there was no death, no stroke, and no paraplegia. There was one case (16.7%) of carotid dissection. Complete aortic remodeling or complete FL thrombosis on the thoracic aorta was found in 18 cases (85.7%) and in five cases (83.3%) in the hybrid and branched endograft groups, respectively. Conclusions: Despite a critical course in most cases of RAD, with a high rate of aneurysmal evolution and reintervention, the long-term mortality rate remains low with a close follow-up and a multidisciplinary management in an expert center.
Feasibility of Non-Invasive Coronary Artery Disease Screening with Coronary CT Angiography before Transcatheter Aortic Valve Implantation
Coronary artery disease (CAD) screening is usually performed before transcatheter aortic valve implantation (TAVI) by invasive coronary angiography (ICA). Computed coronary tomography angiography (CCTA) has shown good diagnostic performance for CAD screening in patients with a low probability of CAD and is systematically performed before TAVI. CCTA could be an efficient alternative to ICA for CAD screening before TAVI. We sought to investigate the diagnostic performance of CCTA in a population of unselected patients without known CAD who were candidates for TAVI. All consecutive patients referred to our center for TAVI without known CAD were enrolled. All patients underwent CCTA and ICA, which were considered the gold standard. A statistical analysis of the diagnostic performance per patient and per artery was performed. 307 consecutive patients were enrolled. CCTA was non-analyzable in 25 patients (8.9%). In the per-patient analysis, CCTA had a sensitivity of 89.6%, a specificity of 90.2%, a positive predictive value of 65.15%, and a negative predictive value of 97.7%. Only five patients were classified as false negatives on the CCTA. Despite some limitations of the study, CCTA seems reliable for CAD screening in patients without known CAD who are candidates for TAVI. By using CCTA, ICA could be avoided in patients with a CAD-RADS score ≤ 2, which represents 74.8% of patients.
Reintervention of Residual Aortic Dissection after Type A Aortic Repair: Results of a Prospective Follow-Up at 5 Years
Background After a type A aortic dissection repair, a patent false lumen in the descending aorta is the most common situation encountered, and is a well-known risk factor for aortic growth, reinterventions and mortality. The aim of this study was to analyze the long-term results of residual aortic dissection (RAD) at a high-volume aortic center with prospective follow-up. Methods In this prospective single-center study, all patients operated for type A aortic dissection between January 2017 and December 2022 were included. Patients without postoperative computed tomography scans or during follow-up at our center, and patients without RAD were excluded. The primary endpoint was all-cause mortality during follow-up for patients with RAD. The secondary endpoints were perioperative mortality, rate of distal aneurysmal evolution, location of distal aneurysmal evolution, rate of distal reinterventions, outcomes of distal reinterventions, and aortic-related death during follow-up. Results In total, 200 survivors of RAD comprised the study group. After a mean follow-up of 27.2 months (1–66), eight patients (4.0%) died and 107 (53.5%) had an aneurysmal progression. The rate of distal reintervention was 19.5% (39/200), for malperfusion syndrome in seven cases (3.5%) and aneurysmal evolution in 32 cases (16.0%). Most reinterventions occurred during the first 2 years (82.1%). Twenty-seven patients were treated for an aneurysmal evolution of RAD including aortic arch with hybrid repair in 21 cases and branched aortic arch endoprosthesis in six cases. In the hybrid repair group, there was no death, and the rate of morbidity was 28.6% (6/21) (one minor stroke, one pulmonary complication, one recurrent paralysis with complete recovery and three major bleeding events). In the branched endograft group, there was no death, no stroke, and no paraplegia. There was one case (16.7%) of carotid dissection. Complete aortic remodeling or complete FL thrombosis on the thoracic aorta was found in 18 cases (85.7%) and in five cases (83.3%) in the hybrid and branched endograft groups, respectively. Conclusions: Despite a critical course in most cases of RAD, with a high rate of aneurysmal evolution and reintervention, the long-term mortality rate remains low with a close follow-up and a multidisciplinary management in an expert center.
Co-limitation towards lower latitudes shapes global forest diversity gradients
The latitudinal diversity gradient (LDG) is one of the most recognized global patterns of species richness exhibited across a wide range of taxa. Numerous hypotheses have been proposed in the past two centuries to explain LDG, but rigorous tests of the drivers of LDGs have been limited by a lack of high-quality global species richness data. Here we produce a high-resolution (0.025° × 0.025°) map of local tree species richness using a global forest inventory database with individual tree information and local biophysical characteristics from ~1.3 million sample plots. We then quantify drivers of local tree species richness patterns across latitudes. Generally, annual mean temperature was a dominant predictor of tree species richness, which is most consistent with the metabolic theory of biodiversity (MTB). However, MTB underestimated LDG in the tropics, where high species richness was also moderated by topographic, soil and anthropogenic factors operating at local scales. Given that local landscape variables operate synergistically with bioclimatic factors in shaping the global LDG pattern, we suggest that MTB be extended to account for co-limitation by subordinate drivers. Examining drivers of the latitudinal biodiversity gradient in a global database of local tree species richness, the authors show that co-limitation by multiple environmental and anthropogenic factors causes steeper increases in richness with latitude in tropical versus temperate and boreal zones.
Natural Guided Genome Engineering Reveals Transcriptional Regulators Controlling Quorum-Sensing Signal Degradation
Quorum-quenching (QQ) are natural or engineered processes disrupting the quorum-sensing (QS) signalling which controls virulence and persistence (e.g. biofilm) in numerous bacteria. QQ involves different enzymes including lactonases, amidases, oxidases and reductases which degrade the QS molecules such as N-acylhomoserine lactones (NAHL). Rhodococcus erythropolis known to efficiently degrade NAHL is proposed as a biocontrol agent and a reservoir of QQ-enzymes for biotechnology. In R. erythropolis, regulation of QQ-enzymes remains unclear. In this work, we performed genome engineering on R. erythropolis, which is recalcitrant to reverse genetics, in order to investigate regulation of QQ-enzymes at a molecular and structural level with the aim to improve the QQ activity. Deep-sequencing of the R. erythropolis enhanced variants allowed identification of a punctual mutation in a key-transcriptional factor QsdR (Quorum sensing degradation Regulation) which regulates the sole QQ-lactonase QsdA identified so far. Using biophysical and structural studies on QsdR, we demonstrate that QQ activity can be improved by modifying the regulation of QQ-enzymes degrading QS signal. This modification requiring the change of only one amino-acid in a transcriptional factor leads to an enhanced R. erythropolis in which the QS-signal degradation pathway is strongly activated.
FLRG, an activin-binding protein, is a new target of TGFβ transcription activation through Smad proteins
The FLRG gene encodes a secreted glycoprotein that binds to activin and is highly homologous to follistatin, an activin ligand. We cloned the promoter region of the human FLRG gene, and defined the minimal region necessary for transcription activation in a reporter-system assay. We showed that the fragment between positions −130 and +6, which consists of multiple consensus Sp1-binding sites, is required for the constitutive expression of the FLRG gene. We demonstrate here that FLRG mRNA expression is rapidly induced by TGFβ or by transfection with Smad protein expression vectors in human HepG2 cells. We investigated the transcription-regulation mechanism of FLRG expression in HepG2 cells following treatment with TGFβ. By deletion and point-mutation analysis of the FLRG promoter, we identified a Smad-binding element involved in the TGFβ-inducible expression of the FLRG gene. Moreover, transactivation of the FLRG promoter by TGFβ was compromised by dominant-negative mutants of Smad3 and Smad4 proteins. In addition, gel electrophoresis mobility-shift assays demonstrated the specific interaction of Smad3 and Smad4 proteins with the Smad-binding element consensus motif found in the FLRG promoter. Taken together, our data imply that Smad proteins participate in the regulation of expression of FLRG, a new target of TGFβ transcription activation.