Clinical implementation of HyperArc
2022
The aim of this study was to present our experience on clinical implementation of HyperArc including dosimetric comparison between VMAT and HyperArc plans and dosimetric verification of HyperArc. In this study, eleven previously treated cases of brain metastasis were selected from our brain stereotactic radiotherapy program. The cases were retrospectively planned using HyperArc technique and the plan quality was evaluated. In addition, dosimetric effects of HyperArc plan with different energies and using jaw tracking technique were evaluated. Furthermore, dosimetric verification of HyperArc plans was performed using ion chamber and radiochromic film. Our results of dosimetric comparison shows that HyperArc technique improved both conformity index and gradient index compared to VMAT plans. We also found that using 6MV flattening filter free (6MV-FFF) beam improves gradient index in HyperArc plans compared to using 6MV flattening filter beam. Furthermore, our results show that jaw tracking technique reduces the size of low dose volume while maintaining similar target coverage, conformity index, and gradient index. In our dosimetric verification study, results of ion chamber and film measurement indicate no significant difference between VMAT and HyperArc plans. In conclusion, HyperArc simplifies planning of stereotactic treatment for brain and improves the dosimetry in treatment plans. Additionally, HyperArc provides for a safe and efficient treatment delivery system for stereotactic treatments to brain.
Journal Article
Modeling and dosimetric performance evaluation of the RayStation treatment planning system
2014
The physics modeling, dose calculation accuracy and plan quality assessment of the RayStation (v3.5) treatment planning system (TPS) is presented in this study, with appropriate comparisons to the more established Pinnacle (v9.2) TPS. Modeling and validation for the Elekta MLCi and Agility beam models resulted in a good match to treatment machine‐measured data based on tolerances of 3% for in‐field and out‐of‐field regions, 10% for buildup and penumbral regions, and a gamma 2%/2 mm dose/distance acceptance criteria. TPS commissioning using a wide range of appropriately selected dosimetry equipment, and following published guidelines, established the MLC modeling and dose calculation accuracy to be within standard tolerances for all tests performed. In both homogeneous and heterogeneous mediums, central axis calculations agreed with measurements within 2% for open fields and 3% for wedged fields, and within 4% off‐axis. Treatment plan comparisons for identical clinical goals were made to Pinnacle for the following complex clinical cases: hypofractionated non‐small cell lung carcinoma, head and neck, stereotactic spine, as well as for several standard clinical cases comprising of prostate, brain, and breast plans. DVHs, target, and critical organ doses, as well as measured point doses and gamma indices, applying both local and global (Van Dyk) normalization at 2%/2 mm and 3%/3 mm (10% lower threshold) acceptance criteria for these composite plans were assessed. In addition 3DVH was used to compare the perturbed dose distributions to the TPS 3D dose distributions. For all 32 cases, the patients QA checks showed > 95% of pixels passing 3% global/3 mm gamma.
PACS numbers: 87.55kd, 87.55km, 87.55de, 87.55dk
Journal Article
Total body irradiation in Australia and New Zealand: results of a practice survey
2020
Total body irradiation (TBI) is an important treatment modality for the preparation of patients for bone marrow transplants. It is technically challenging and the actual delivery may vary from clinic to clinic. Knowledge of the pattern of practice may be helpful for clinics to determine future practice. We carried out an email survey from April to September 2019 sending 48 TBI related questions to all radiotherapy clinics in Australia and New Zealand via the Australasian College of Physical Scientists in Medicine email distribution list. Centres not performing TBI were not expected to complete the survey and centres that had participated in a previous survey, or that were known to perform the treatment, were followed up if no response was received. Of a total of approximately 70 centres, 14 clinics responded to the survey. The vast majority of clinics use conventional lateral and/or anterior–posterior beams at extended SSD for TBI treatment delivery. However, treatment planning, ancillary equipment (used for immobilisation/modulation), beam energy and prescribed lung doses vary considerably—with some clinics delivering the prescription dose to the lungs and some aiming to deliver a lung dose which is lower than the prescription dose. Only one clinic reported using an advanced delivery technique with modulated arcs at extended SSD. Centres either said they had no access to outcome data or did not answer this question. Compared with an earlier survey from 2005, 3 clinics have lowered their linac dose rate and 7 are the same or similar. The TBI practice in Australia and New Zealand remains varied, with considerable differences in treatment planning, beam energy, accepted lung doses and delivered dose rates.
Journal Article
Evaluation of linear array MOSFET detectors for in vivo dosimetry to measure rectal dose in HDR brachytherapy
by
Haughey, Aisling
,
Coalter, George
,
Mugabe, Koki
in
Biological and Medical Physics
,
Biomedical and Life Sciences
,
Biomedical Engineering and Bioengineering
2011
The study aimed to assess the suitability of linear array metal oxide semiconductor field effect transistor detectors (MOSFETs) as in vivo dosimeters to measure rectal dose in high dose rate brachytherapy treatments. The MOSFET arrays were calibrated with an Ir192 source and phantom measurements were performed to check agreement with the treatment planning system. The angular dependence, linearity and constancy of the detectors were evaluated. For in vivo measurements two sites were investigated, transperineal needle implants for prostate cancer and Fletcher suites for cervical cancer. The MOSFETs were inserted into the patients’ rectum in theatre inside a modified flatus tube. The patients were then CT scanned for treatment planning. Measured rectal doses during treatment were compared with point dose measurements predicted by the TPS. The MOSFETs were found to require individual calibration factors. The calibration was found to drift by approximately 1% ±0.8 per 500 mV accumulated and varies with distance from source due to energy dependence. In vivo results for prostate patients found only 33% of measured doses agreed with the TPS within ±10%. For cervix cases 42% of measured doses agreed with the TPS within ±10%, however of those not agreeing variations of up to 70% were observed. One of the most limiting factors in this study was found to be the inability to prevent the MOSFET moving internally between the time of CT and treatment. Due to the many uncertainties associated with MOSFETs including calibration drift, angular dependence and the inability to know their exact position at the time of treatment, we consider them to be unsuitable for in vivo dosimetry in rectum for HDR brachytherapy.
Journal Article