Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
39 result(s) for "Navarro-Ramirez, Rodrigo"
Sort by:
Defining the MIS-TLIF: A Systematic Review of Techniques and Technologies Used by Surgeons Worldwide
Study Design: Systematic review. Objective: To date there is no consensus among surgeons as to what defines an MIS-TLIF (transforaminal lumbar interbody fusion using minimally invasive spine surgery) compared to an open or mini-open TLIF. This systematic review aimed to examine the MIS-TLIF techniques reported in the recent body of literature to help provide a definition of what constitutes the MIS-TLIF, based on the consensus of the majority of surgeons. Methods: We created a database of articles published about MIS-TLIF between 2010 and 2018. We evaluated the technical components of the MIS-TLIF including instruments and incisions used as well the order in which key steps are performed. Results: We could identify several patterns for MIS-TLIF performance that seemed agreed upon by the majority of MIS surgeons: use of paramedian incisions; use of a tubular retractor to perform a total facetectomy, decompression, and interbody cage implantation; and percutaneous insertion of the pedicle-screw rod constructs with intraoperative imaging. Conclusion: Based on this review of the literature, the key features used by surgeons performing MIS TLIF include the use of nonexpandable or expandable tubular retractors, a paramedian or lateral incision, and the use of a microscope or endoscope for visualization. Approaches using expandable nontubular retractors, those that require extensive subperiosteal dissection from the midline laterally, or specular-based retractors with wide pedicle to pedicle exposure are far less likely to be promoted as an MIS-based approach. A definition is necessary to improve the communication among spine surgeons in research as well as patient education.
Indirect Decompression Failure After Lateral Lumbar Interbody Fusion—Reported Failures and Predictive Factors: Systematic Review
Background: In patients with symptomatic lumbar stenosis undergoing lateral transpsoas approach for lumbar interbody fusion (LLIF) surgery, it is not always clear when indirect decompression is sufficient in order to achieve symptom resolution. Indirect decompression failure (IDF), defined as “postoperative persistent symptoms of nerve compression with or without a second direct decompression surgery to reach adequate symptom resolution,” is not widely reported. This information, however, is critical to better understand the indications, the potential, and the limitations of indirect decompression. Objective: The purpose of this study was to systematically review the current literature on IDF after LLIF. Methods: A literature search was performed on PubMed. We included randomized controlled trials and prospective, retrospective, case-control studies, and case reports. Information on sample size, demographics, procedure, number and location of involved levels, follow-up time, and complications were extracted. Results: After applying the exclusion criteria, we included 9 of the 268 screened articles that reported failure. A total of 632 patients were screened in these articles and detailed information was provided. Average follow-up time was 21 months. Overall reported incidence of IDF was 9%. Conclusion: Failures of decompression via LLIF are inconsistently reported and the incidence is approximately 9%. IDF failure in LLIF may be underreported or misinterpreted as a complication. We propose to include the term “IDF” as described in this article to differentiate them from complications for future studies. A better understanding of why IDF occurs will allow surgeons to better plan surgical intervention and will avoid revision surgery.
Mesenchymal Stem Cell-Seeded High-Density Collagen Gel for Annular Repair: 6-Week Results From In Vivo Sheep Models
Our group has previously demonstrated in vivo annulus fibrosus repair in animal models using an acellular, riboflavin crosslinked, high-density collagen (HDC) gel. To assess if seeding allogenic mesenchymal stem cells (MSCs) into this gel yields improved histological and radiographic benefits in an in vivo sheep model of annular injury. Fifteen lumbar intervertebral discs (IVDs) were randomized into 4 groups: intact, injury only, injury + acellular gel treatment, or injury + MSC-seeded gel treatment. Sheep were sacrificed at 6 wk. Disc height index (DHI), Pfirrmann grade, nucleus pulposus area, and T2 relaxation time (T2-RT) were calculated for each IVD and standardized to healthy controls from the same sheep. Quantitative histological assessment was also performed using the Han scoring system. All treated IVDs retained gel plugs on gross assessment and there were no adverse perioperative complications. The MSC-seeded gel treatment group demonstrated statistically significant improvement over other experimental groups in DHI (P = .002), Pfirrmann grade (P < .001), and T2-RT (P = .015). There was a trend for greater Han scores in the MSC-seeded gel-treated discs compared with injury only and acellular gel-treated IVDs (P = .246). MSC-seeded HDC gel can be delivered into injured IVDs and maintained safely in live sheep to 6 wk. Compared with no treatment and acellular HDC gel, our data show that MSC-seeded HDC gel improves outcomes in DHI, Pfirrmann grade, and T2-RT. Histological analysis shows improved annulus fibrosus and nucleus pulposus reconstitution and organization over other experimental groups as well.
Minimally Invasive Transforaminal Lumbar Interbody Fusion: Meta-analysis of the Fusion Rates. What is the Optimal Graft Material?
Abstract BACKGROUND Minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) is an increasingly popular procedure with several potential advantages over traditional open TLIF. OBJECTIVE The current study aimed to compare fusion rates of different graft materials used in MIS-TLIF, via meta-analysis of the published literature. METHODS A Medline search was performed and a database was created including patient's type of graft, clinical outcome, fusion rate, fusion assessment modality, and duration of follow-up. Meta-analysis of the fusion rate was performed using StatsDirect software (StatsDirect Ltd, Cheshire, United Kingdom). RESULTS A total of 1533 patients from 40 series were included. Fusion rates were high, ranging from 91.8% to 99%. The imaging modalities used to assess fusion were computed tomography scans (30%) and X-rays (70%). Comparison of all recombinant human bone morphogenetic protein (rhBMP) series with all non-rhBMP series showed fusion rates of 96.6% and 92.5%, respectively. The lowest fusion rate was seen with isolated use of autologous local bone (91.8%). The highest fusion rate was observed with combination of autologous local bone with bone extender and rhBMP (99.1%). The highest fusion rate without the use of BMP was seen with autologous local bone + bone extender (93.1%). The reported complication rate ranged from 0% to 35.71%. Clinical improvement was observed in all studies. CONCLUSION Fusion rates are generally high with MIS-TLIF regardless of the graft material used. Given the potential complications of iliac bone harvesting and rhBMP, use of other bone graft options for MIS-TLIF is reasonable. The highest fusion rate without the use of rhBMP was seen with autologous local bone plus bone extender (93.1%).
Resorbable plating system stabilizes tissue‐engineered intervertebral discs implanted ex vivo in canine cervical spines
Total disc replacement using tissue‐engineered intervertebral discs (TE‐IVDs) may offer a biological alternative to treat radiculopathy caused by disc degeneration. A composite TE‐IVD was previously developed and evaluated in rat tail and beagle cervical spine models in vivo. Although cell viability and tissue integration into host tissue were promising, significant implant displacement occurred at multiple spinal levels. The goal of the present study was to assess the effects of a resorbable plating system on the stiffness of motion segments and stability of tissue‐engineered implants subjected to axial compression. Canine motion segments from levels C2/C3 to C5/C6 were assessed as intact (CTRL), after discectomy (Dx), with an implanted TE‐IVD only (PLATE−), and with a TE‐IVD combined with an attached resorbable plate (PLATE+). Segments under PLATE+ conditions fully restored separation between endplates and showed significantly higher compressive stiffness than segments under PLATE− conditions. Plated segments partially restored more than 25% of the CTRL motion segment stiffness. Plate attachment also prevented implant extrusion from the disc space at 50% compressive strain, and this effect was more significant in segments from levels C3/C4 when compared to segments from level C5/C6. These results suggest that stabilization of motion segments via resorbable plating assists TE‐IVD retention in the disc space while allowing the opportunity for implants to fully integrate into the host tissue and achieve optimal restoration of spine biomechanics. In this study, we assessed the effects of a resorbable plating system combined with an implanted tissue‐engineered intervertebral disc on initial endplate separation and compressive stiffness of motion segments from canine cervical spines. We also compared the stability of tissue‐engineered implants in C3/C4 and C5/C6 segments with and without an attached resorbable plate (PLATE+ vs. PLATE‐) using digital image correlation. Our data suggests that stabilization with resorbable plating prevents implant extrusion, partially restores compressive stiffness, and helps avert endplate collapse.
Total disc replacement using tissue-engineered intervertebral discs in the canine cervical spine
The most common reason that adults in the United States see their physician is lower back or neck pain secondary to degenerative disc disease. To date, approaches to treat degenerative disc disease are confined to purely mechanical devices designed to either eliminate or enable flexibility of the diseased motion segment. Tissue engineered intervertebral discs (TE-IVDs) have been proposed as an alternative approach and have shown promise in replacing native IVD in the rodent tail spine. Here we demonstrate the efficacy of our TE-IVDs in the canine cervical spine. TE-IVD components were constructed using adult canine annulus fibrosis and nucleus pulposus cells seeded into collagen and alginate hydrogels, respectively. Seeded gels were formed into a single disc unit using molds designed from the geometry of the canine spine. Skeletally mature beagles underwent discectomy with whole IVD resection at levels between C3/4 and C6/7, and were then divided into two groups that received only discectomy or discectomy followed by implantation of TE-IVD. Stably implanted TE-IVDs demonstrated significant retention of disc height and physiological hydration compared to discectomy control. Both 4-week and 16-week histological assessments demonstrated chondrocytic cells surrounded by proteoglycan-rich matrices in the NP and by fibrocartilaginous matrices in the AF portions of implanted TE-IVDs. Integration into host tissue was confirmed over 16 weeks without any signs of immune reaction. Despite the significant biomechanical demands of the beagle cervical spine, our stably implanted TE-IVDs maintained their position, structure and hydration as well as disc height over 16 weeks in vivo.
Total 3D Airo® Navigation for Minimally Invasive Transforaminal Lumbar Interbody Fusion
Introduction. A new generation of iCT scanner, Airo®, has been introduced. The purpose of this study is to describe how Airo facilitates minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF). Method. We used the latest generation of portable iCT in all cases without the assistance of K-wires. We recorded the operation time, number of scans, and pedicle screw accuracy. Results. From January 2015 to December 2015, 33 consecutive patients consisting of 17 men and 16 women underwent single-level or two-level MIS-TLIF operations in our institution. The ages ranged from 23 years to 86 years (mean, 66.6 years). We treated all the cases in MIS fashion. In four cases, a tubular laminectomy at L1/2 was performed at the same time. The average operation time was 192.8 minutes and average time of placement per screw was 2.6 minutes. No additional fluoroscopy was used. Our screw accuracy rate was 98.6%. No complications were encountered. Conclusions. Airo iCT MIS-TLIF can be used for initial planning of the skin incision, precise screw, and cage placement, without the need for fluoroscopy. “Total navigation” (complete intraoperative 3D navigation without fluoroscopy) can be achieved by combining Airo navigation with navigated guide tubes for screw placement.
Senolytic Combination Treatment Is More Potent Than Single Drugs in Reducing Inflammatory and Senescence Burden in Cells from Painful Degenerating IVDs
Background: Low back pain is a global health problem directly related to intervertebral disc (IVD) degeneration. Senolytic drugs (RG-7112 and o-Vanillin) target and remove senescent cells from IVDs in vitro, improving tissue homeostasis. One drawback of using a single senolytic agent is the failure to target multiple senescent antiapoptotic pathways. This study aimed to determine if combining the two senolytic drugs, o-Vanillin and RG-7112, could more efficiently remove senescent cells and reduce the release of inflammatory factors and pain mediators in cells from degenerating human IVDs than either drug alone. Methods: Preliminary data evaluating multiple concentrations of o-Vanillin and RG-7112 led to the selection of four treatment groups. Monolayer and pellet cultures of cells from painful degenerate IVDs were exposed to TLR-2/6 agonist. They were then treated with the senolytics o-Vanillin and RG7112 alone or combined. p16ink4a, Ki-67, caspase-3, inflammatory mediators, and neuronal sprouting were assessed. Results: Compared to the single treatments, the combination of o-Vanillin and RG-7112 significantly reduced the amount of senescent IVD cells, proinflammatory cytokines, and neurotrophic factors. Moreover, both single and combination treatments significantly reduced neuronal sprouting in rat adrenal pheochromocytoma (PC-12 cells). Conclusions: Combining o-Vanillin and RG-7112 greatly enhanced the effect of either senolytic alone. Together, these results support the potential of senolytics as a promising treatment for IVD-related low back pain.
Lateral Lumbar Interbody Fusion (LLIF): An Update
Degenerative lumbar spine disease (DLSD) is a heterogenous group of conditions that can significantly affect patients’ quality of life. Lateral lumbar interbody fusion (LLIF) is one of the treatment modalities for DLSD that has been increasing in popularity over the past decade. The treatment of DLSD should be individualized based on patients’ symptoms and characteristics to maximize outcomes. Methods: Literature review, invited review. Results: In this article, we will (1) review the use of the LLIF technique in the treatment of degenerative lumbar spine disease, (2) review the current concepts of LLIF, and (3) explore the evidence to date that will allow the reader to maximize the benefits of this technique. Conclusions: LLIF is an alternative for the treatment of degenerative pathologies of the lumbar spine via indirect decompression.
Use of a High-Fidelity Training Simulator for Minimally Invasive Lumbar Decompression Increases Working Knowledge and Technical Skills Among Orthopedic and Neurosurgical Trainees
Study Design Prospective comparative study. Objective To quantify the educational benefit to surgical trainees of using a high-fidelity simulator to perform minimally invasive (MIS) unilateral laminotomy for bilateral decompression (ULBD) for lumbar stenosis. Methods Twelve orthopedic and neurologic surgery residents performed three MIS ULBD procedures over 2 weeks on a simulator guided by established AO Spine metrics. Video recording of each surgery was rated by three blinded, independent experts using a global rating scale. The learning curve was evaluated with attention to technical skills, skipped steps, occurrence of errors, and timing. A knowledge gap analysis evaluating participants’ current vs desired ability was performed after each trial. Results From trial 1 to 3, there was a decrease in average procedural time by 31.7 minutes. The cumulative number of skipped steps and surgical errors decreased from 25 to 6 and 24 to 6, respectively. Overall surgical proficiency improved as indicated by video rating of efficiency and smoothness of surgical maneuvers, most notably with knowledge and handling of instruments. The greatest changes were noted in junior rather than senior residents. Average knowledge gap analysis significantly decreased by 30% from the first to last trial (P = .001), signifying trainees performed closer to their desired technical goal. Conclusion Procedural metrics for minimally invasive ULBD in combination with a realistic surgical simulator can be used to improve the skills and confidence of trainees. Surgical simulation may offer an important educational complement to traditional methods of skill acquisition and should be explored further with other MIS techniques.