Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
31 result(s) for "Noakes, Catherine"
Sort by:
Far-UVC (222 nm) efficiently inactivates an airborne pathogen in a room-sized chamber
Many infectious diseases, including COVID-19, are transmitted by airborne pathogens. There is a need for effective environmental control measures which, ideally, are not reliant on human behaviour. One potential solution is Krypton Chloride (KrCl) excimer lamps (often referred to as Far-UVC), which can efficiently inactivate pathogens, such as coronaviruses and influenza, in air. Research demonstrates that when KrCl lamps are filtered to remove longer-wavelength ultraviolet emissions they do not induce acute reactions in the skin or eyes, nor delayed effects such as skin cancer. While there is laboratory evidence for Far-UVC efficacy, there is limited evidence in full-sized rooms. For the first time, we show that Far-UVC deployed in a room-sized chamber effectively inactivates aerosolised Staphylococcus aureus . At a room ventilation rate of 3 air-changes-per-hour (ACH), with 5 filtered-sources the steady-state pathogen load was reduced by 98.4% providing an additional 184 equivalent air changes (eACH). This reduction was achieved using Far-UVC irradiances consistent with current American Conference of Governmental Industrial Hygienists threshold limit values for skin for a continuous 8-h exposure. Our data indicate that Far-UVC is likely to be more effective against common airborne viruses, including SARS-CoV-2, than bacteria and should thus be an effective and “hands-off” technology to reduce airborne disease transmission. The findings provide room-scale data to support the design and development of effective Far-UVC systems.
Infectious virus in exhaled breath of symptomatic seasonal influenza cases from a college community
Little is known about the amount and infectiousness of influenza virus shed into exhaled breath. This contributes to uncertainty about the importance of airborne influenza transmission. We screened 355 symptomatic volunteers with acute respiratory illness and report 142 cases with confirmed influenza infection who provided 218 paired nasopharyngeal (NP) and 30-minute breath samples (coarse >5-μm and fine ≤5-μm fractions) on days 1–3 after symptom onset. We assessed viral RNA copy number for all samples and cultured NP swabs and fine aerosols. We recovered infectious virus from 52 (39%) of the fine aerosols and 150 (89%) of the NP swabs with valid cultures. The geometric mean RNA copy numbers were 3.8 × 10⁴/30-minutes fine-, 1.2 × 10⁴/30-minutes coarse-aerosol sample, and 8.2 × 10⁸ per NP swab. Fine- and coarse-aerosol viral RNA were positively associated with body mass index and number of coughs and negatively associated with increasing days since symptom onset in adjusted models. Fine-aerosol viral RNA was also positively associated with having influenza vaccination for both the current and prior season. NP swab viral RNA was positively associated with upper respiratory symptoms and negatively associated with age but was not significantly associated with fine- or coarse-aerosol viral RNA or their predictors. Sneezing was rare, and sneezing and coughing were not necessary for infectious aerosol generation. Our observations suggest that influenza infection in the upper and lower airways are compartmentalized and independent.
Use of Multiple Low Cost Carbon Dioxide Sensors to Measure Exhaled Breath Distribution with Face Mask Type and Wearing Behaviour
The use of cloth face coverings and face masks has become widespread in light of the COVID-19 pandemic. This paper presents a method of using low cost wirelessly connected carbon dioxide (CO2) sensors to measure the effects of properly and improperly worn face masks on the concentration distribution of exhaled breath around the face. Four types of face masks are used in two indoor environment scenarios. CO2 as a proxy for exhaled breath is being measured with the Sensirion SCD30 CO2 sensor, and data are being transferred wirelessly to a base station. The exhaled CO2 is measured in four directions at various distances from the head of the subject, and interpolated to create spatial heat maps of CO2 concentration. Statistical analysis using the Friedman’s analysis of variance (ANOVA) test is carried out to determine the validity of the null hypotheses (i.e., distribution of the CO2 is same) between different experiment conditions. Results suggest CO2 concentrations vary little with the type of mask used; however, improper use of the face mask results in statistically different CO2 spatial distribution of concentration. The use of low cost sensors with a visual interpolation tool could provide an effective method of demonstrating the importance of proper mask wearing to the public.
Quality in care homes: How wearable devices and social network analysis might help
Social network analysis can support quality improvement in care homes but traditional approaches to social network analysis are not always feasible in care homes. Recalling contacts and movements in a home is difficult for residents and staff and documentary and other sources of individual contacts can be unreliable. Bluetooth enabled wearable devices are a potential means of generating reliable, trustworthy, social network data in care home communities. In this paper, we explore the empirical, theoretical and real-world potential and difficulties in using Bluetooth enabled wearables with residents and staff in care homes for quality improvement. We demonstrate, for the first time, that a relatively simple system built around the Internet of Things, Bluetooth enabled wearables for residents and staff and passive location devices (the CONTACT intervention) can capture social networks and data in homes, enabling social network analysis, measures, statistics and visualisations. Unexpected variations in social network measures and patterns are surfaced, alongside “uncomfortable” information concerning staff time spent with residents. We show how technology might also help identify those most in need of social contact in a home. The possibilities of technology-enabled social network analysis must be balanced against the implementation-related challenges associated with introducing innovations in complex social systems such as care homes. Behavioural challenges notwithstanding, we argue that armed with social network information, care home staff could better tailor, plan and evaluate the effects of quality improvement with the sub-communities that make up a care home community.
Minimal transmission in an influenza A (H3N2) human challenge-transmission model within a controlled exposure environment
Uncertainty about the importance of influenza transmission by airborne droplet nuclei generates controversy for infection control. Human challenge-transmission studies have been supported as the most promising approach to fill this knowledge gap. Healthy, seronegative volunteer 'Donors' (n = 52) were randomly selected for intranasal challenge with influenza A/Wisconsin/67/2005 (H3N2). 'Recipients' randomized to Intervention (IR, n = 40) or Control (CR, n = 35) groups were exposed to Donors for four days. IRs wore face shields and hand sanitized frequently to limit large droplet and contact transmission. One transmitted infection was confirmed by serology in a CR, yielding a secondary attack rate of 2.9% among CR, 0% in IR (p = 0.47 for group difference), and 1.3% overall, significantly less than 16% (p<0.001) expected based on a proof-of-concept study secondary attack rate and considering that there were twice as many Donors and days of exposure. The main difference between these studies was mechanical building ventilation in the follow-on study, suggesting a possible role for aerosols.
Effect of Relative Humidity on Transfer of Aerosol-Deposited Artificial and Human Saliva from Surfaces to Artificial Finger-Pads
Surface to hand transfer of viruses represents a potential mechanism for human exposure. An experimental process for evaluating the touch transfer of aerosol-deposited material is described based on controlling surface, tribological, and soft matter components of the transfer process. A range of high-touch surfaces were evaluated. Under standardized touch parameters (15 N, 1 s), relative humidity (RH) of the atmosphere around the contact transfer event significantly influenced transfer of material to the finger-pad. At RH < 40%, transfer from all surfaces was <10%. Transfer efficiency increased markedly as RH increased, reaching a maximum of approximately 50%. The quantity of material transferred at specific RHs above 40% was also dependent on roughness of the surface material and the properties of the aerosol-deposited material. Smooth surfaces, such as melamine and stainless steel, generated higher transfer efficiencies compared to those with textured roughness, such as ABS pinseal and KYDEX® plastics. Pooled human saliva was transferred at a lower rate compared to artificial saliva, indicating the role of rheological properties. The artificial saliva data were modeled by non-linear regression and the impact of environmental humidity and temperature were evaluated within a Quantitative Microbial Risk Assessment model using SARS-CoV-2 as an example. This illustrated that the trade-off between transfer efficiency and virus survival may lead to the highest risks of fomite transmissions in indoor environments with higher humidity.
The Infectiousness of Tuberculosis Patients Coinfected with HIV
The current understanding of airborne tuberculosis (TB) transmission is based on classic 1950s studies in which guinea pigs were exposed to air from a tuberculosis ward. Recently we recreated this model in Lima, Perú, and in this paper we report the use of molecular fingerprinting to investigate patient infectiousness in the current era of HIV infection and multidrug-resistant (MDR) TB. All air from a mechanically ventilated negative-pressure HIV-TB ward was exhausted over guinea pigs housed in an airborne transmission study facility on the roof. Animals had monthly tuberculin skin tests, and positive reactors were removed for autopsy and organ culture for M. tuberculosis. Temporal exposure patterns, drug susceptibility testing, and DNA fingerprinting of patient and animal TB strains defined infectious TB patients. Relative patient infectiousness was calculated using the Wells-Riley model of airborne infection. Over 505 study days there were 118 ward admissions of 97 HIV-positive pulmonary TB patients. Of 292 exposed guinea pigs, 144 had evidence of TB disease; a further 30 were tuberculin skin test positive only. There was marked variability in patient infectiousness; only 8.5% of 118 ward admissions by TB patients were shown by DNA fingerprinting to have caused 98% of the 125 characterised cases of secondary animal TB. 90% of TB transmission occurred from inadequately treated MDR TB patients. Three highly infectious MDR TB patients produced 226, 52, and 40 airborne infectious units (quanta) per hour. A small number of inadequately treated MDR TB patients coinfected with HIV were responsible for almost all TB transmission, and some patients were highly infectious. This result highlights the importance of rapid TB drug-susceptibility testing to allow prompt initiation of effective treatment, and environmental control measures to reduce ongoing TB transmission in crowded health care settings. TB infection control must be prioritized in order to prevent health care facilities from disseminating the drug-resistant TB that they are attempting to treat.
Expert elicitation on the relative importance of possible SARS-CoV-2 transmission routes and the effectiveness of mitigations
ObjectivesTo help people make decisions about the most effective mitigation measures against SARS-CoV-2 transmission in different scenarios, the likelihoods of transmission by different routes need to be quantified to some degree (however uncertain). These likelihoods need to be communicated in an appropriate way to illustrate the relative importance of different routes in different scenarios, the likely effectiveness of different mitigation measures along those routes, and the level of uncertainty in those estimates. In this study, a pragmatic expert elicitation was undertaken to supply the underlying quantitative values to produce such a communication tool.ParticipantsTwenty-seven individual experts from five countries and many scientific disciplines provided estimates.Outcome measuresEstimates of transmission parameters, assessments of the quality of the evidence, references to relevant literature, rationales for their estimates and sources of uncertainty.Results and conclusionThe participants’ responses showed that there is still considerable disagreement among experts about the relative importance of different transmission pathways and the effectiveness of different mitigation measures due to a lack of empirical evidence. Despite these disagreements, when pooled, the majority views on each parameter formed an internally consistent set of estimates (for example, that transmission was more likely indoors than outdoors, and at closer range), which formed the basis of a visualisation to help individuals and organisations understand the factors that influence transmission and the potential benefits of different mitigation measures.
Upper-Room Ultraviolet Light and Negative Air Ionization to Prevent Tuberculosis Transmission
Background: Institutional tuberculosis (TB) transmission is an important public health problem highlighted by the HIV/AIDS pandemic and the emergence of multidrug- and extensively drug-resistant TB. Effective TB infection control measures are urgently needed. We evaluated the efficacy of upper-room ultraviolet (UV) lights and negative air ionization for preventing airborne TB transmission using a guinea pig air-sampling model to measure the TB infectiousness of ward air. Methods and Findings: For 535 consecutive days, exhaust air from an HIV-TB ward in Lima, Perú, was passed through three guinea pig air-sampling enclosures each housing approximately 150 guinea pigs, using a 2-d cycle. On UV-off days, ward air passed in parallel through a control animal enclosure and a similar enclosure containing negative ionizers. On UV-on days, UV lights and mixing fans were turned on in the ward, and a third animal enclosure alone received ward air. TB infection in guinea pigs was defined by monthly tuberculin skin tests. All guinea pigs underwent autopsy to test for TB disease, defined by characteristic autopsy changes or by the culture of Mycobacterium tuberculosis from organs. 35% (106/304) of guinea pigs in the control group developed TB infection, and this was reduced to 14% (43/303) by ionizers, and to 9.5% (29/307) by UV lights (both p < 0.0001 compared with the control group). TB disease was confirmed in 8.6% (26/304) of control group animals, and this was reduced to 4.3% (13/303) by ionizers, and to 3.6% (11/307) by UV lights (both p < 0.03 compared with the control group). Time-to-event analysis demonstrated that TB infection was prevented by ionizers (log-rank 27; p < 0.0001) and by UV lights (log-rank 46; p < 0.0001). Time-to-event analysis also demonstrated that TB disease was prevented by ionizers (log-rank 3.7; p = 0.055) and by UV lights (log-rank 5.4; p = 0.02). An alternative analysis using an airborne infection model demonstrated that ionizers prevented 60% of TB infection and 51% of TB disease, and that UV lights prevented 70% of TB infection and 54% of TB disease. In all analysis strategies, UV lights tended to be more protective than ionizers. Conclusions: Upper-room UV lights and negative air ionization each prevented most airborne TB transmission detectable by guinea pig air sampling. Provided there is adequate mixing of room air, upper-room UV light is an effective, low-cost intervention for use in TB infection control in high-risk clinical settings.
CONTACT: a non-randomised feasibility study of bluetooth-enabled wearables for contact tracing in UK care homes during the COVID-19 pandemic
Background The need for effective non-pharmaceutical infection prevention measures such as contact tracing in pandemics remains in care homes, but traditional approaches to contact tracing are not feasible in care homes. The CONTACT intervention introduces Bluetooth-enabled wearable devices (BLE wearables) as a potential solution for automated contact tracing. Using structured reports and reports triggered by positive COVID-19 cases in homes, we fed contact patterns and trends back to homes to support better-informed infection prevention decisions and reduce blanket application of restrictive measures. This paper reports on the evaluation of feasibility and acceptability of the intervention prior to a planned definitive cluster randomised trial of the CONTACT BLE wearable intervention. Methods CONTACT was a non-randomised mixed-method feasibility study over 2 months in four English care homes. Recruitment was via care home research networks, with individual consent. Data collection methods included routine data from the devices, case report forms, qualitative interviews (with staff and residents), field observation of care, and an adapted version of the NoMaD survey instrument to explore implementation using Normalisation Process Theory. Quantitative data were analysed using descriptive statistical methods. Qualitative data were thematically analysed using a framework approach and Normalisation Process Theory. Intervention and study delivery were evaluated against predefined progression criteria. Results Of 156 eligible residents, 105 agreed to wear a device, with 102 (97%) starting the intervention. Of 225 eligible staff, 82% ( n  = 178) participated. Device loss and damage were significant: 11% of resident devices were lost or damaged, ~ 50% were replaced. Staff lost fewer devices, just 6%, but less than 10% were replaced. Fob wearables needed more battery changes than card-type devices (15% vs. 0%). Structured and reactive feedback was variably understood by homes but unlikely to be acted on. Researcher support for interpreting reports was valued. Homes found information useful when it confirmed rather than challenged preconceived contact patterns. Staff privacy concerns were a barrier to adoption. Study procedures added to existing work, making participation burdensome. Study participation benefits did not outweigh perceived burden and were amplified by the pandemic context. CONTACT did not meet its quantitative or qualitative progression criteria. Conclusion CONTACT found a large-scale definitive trial of BLE wearables for contact tracing and feedback-informed IPC in care homes unfeasible and unacceptable — at least in the context of shifting COVID-19 pandemic demands. Future research should co-design interventions and studies with care homes, focusing on successful intervention implementation as well as technical effectiveness. Trial registration ISRCTN registration: 11204126 registered 17/02/2021.