Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
77 result(s) for "Odou, Pascal"
Sort by:
Factors relevant to medication non-adherence in kidney transplant: a systematic review
Background Medication non-adherence is a major issue after transplant that can lead to misdiagnosis, rejection, poor health affecting quality of life, graft loss or death. Several estimations of adherence and related factors have previously been described but conclusions leave doubt as to the most accurate assessment method. Aim of the review To identify the factors most relevant to medication non-adherence in kidney transplant in current clinical practice. Method This systematic review is registered in the PROSPERO data base and follows the Prisma checklist. Articles in English in three databases from January 2009 to December 2014 were analysed. A synthesis was made to target adherence assessment methods, their prevalence and significance. Results Thirty-seven studies were analysed rates of non-adherence fluctuating from 1.6 to 96%. Assessment methods varied from one study to another, although self-reports were mainly used. It appears that youth (≤50 years old), male, low social support, unemployment, low education, ≥3 months post graft, living donor, ≥6 comorbidities, ≥5 drugs/d, ≥2 intakes/d, negative beliefs, negative behavior, depression and anxiety were the factors significantly related to non-adherence. Conclusion As there are no established guidelines, consideration should be given to more than one approach to identify medication non-adherence although self-reports should remain the cornerstone of adherence assessment.
Efficiency of four solutions in removing 23 conventional antineoplastic drugs from contaminated surfaces
Residual contamination by intravenous conventional antineoplastic drugs (ICAD) is still a daily issue in hospital facilities. This study aimed to compare the efficiency (EffQ) of 4 different solutions to remove 23 widely used ICADs from surfaces. A solution containing 23 ICADs (4 alkylating agents, 8 antimetabolites, 2 topo-I inhibitors, 6 topo-II inhibitors and 3 spindle poisons) was spread over 100 cm2 stainless steel. After drying, decontamination was carried out using 10×10 cm wipes moistened with 300 μL of one of the following solutions: 70% isopropanol (S1); ethanol-hydrogen peroxide 91.6-50.0 mg/g (S2); 10-2 M sodium dodecyl sulphate/isopropanol 80/20 (S3) or 0.5% sodium hypochlorite (S4). Six tests were performed for each decontamination solution. Two modalities were tested: a single wipe motion from top to bottom or vigorous wiping (n = 6 for each modality). Residual contamination was measured with a validated liquid chromatography with tandem mass spectrometry detection method. Solution efficiency (in %) was computed as follows: EffQ = 1-(quantity after decontamination/quantity before decontamination), as median (min-max) for the 23 ICADs. The overall decontamination efficiency (EffQ) of the 4 solutions was compared by a Kruskall-Wallis test. Decontamination modalities were compared for each solution and per ICAD with a Mann-Whitney test (p<0.05). EffQ were significantly different from one solution to the next for single wipe motion decontamination: 79.9% (69.3-100), 86.5% (13.0-100), 85.4% (56.5-100) and 100% (52.9-100) for S1, S2, S3 and S4 (p<0.0001), respectively. Differences were also significant for vigorous decontamination: EffQ of 84.3% (66.0-100), 92.3% (68.7-100), 99.6% (84.8-100) and 100% (82.9-100) for S1, S2, S3 and S4, respectively (p<0.0001). Generally, vigorous decontamination increased EffQ for all tested solutions and more significantly for the surfactant. Decontamination efficiency depended on the solution used but also on the application modality. An SDS admixture seems to be a good alternative to sodium hypochlorite, notably after vigorous chemical decontamination with no hazard either to materials or workers.
Strategies to prevent drug incompatibility during simultaneous multi-drug infusion in intensive care units: a literature review
PurposeDrug protocols in intensive care units may require the concomitant administration of many drugs as patients’ venous accesses are often limited. A major challenge for clinicians is to limit the risk of simultaneously infusing incompatible drugs. Incompatibilities can lead to the formation of particles and inactivation of drugs, whose consequences on the body have already been indicated. Our objective was to assess current strategies to counter the risk of incompatible infusions and control the resulting clinical consequences.MethodsThis review was independently conducted by three investigators in respect of the PRISMA statement. Three online databases were consulted. Full-text articles, notes, or letters written in English or French, published or in press between the 1990s and the end of February 2020, with clinical study design, were eligible. Parameters of interest were mainly number and size of particles, and a number of observed/avoided incompatibilities.ResultsAll in all, 382 articles were screened, 17 meeting all the acceptance criteria. The strategies outlined and assessed were filtration, the use of multi-lumen devices, the purging of infusion lines, incompatibility tables and databases, and the use of standard operating procedures.ConclusionAlthough many strategies have been developed in recent years to address drug incompatibility risks, clinical data is still lacking. All studies with in vitro design were excluded although some current innovative strategies, like niosomes, should be considered and studied by means of clinical data in the future.
Effectiveness of a Closed-System Transfer Device in Reducing Surface Contamination in a New Antineoplastic Drug-Compounding Unit: A Prospective, Controlled, Parallel Study
The objective of this randomized, prospective and controlled study was to investigate the ability of a closed-system transfer device (CSTD; BD-Phaseal) to reduce the occupational exposure of two isolators to 10 cytotoxic drugs and compare to standard compounding devices. The 6-month study started with the opening of a new compounding unit. Two isolators were set up with 2 workstations each, one to compound with standard devices (needles and spikes) and the other using the Phaseal system. Drugs were alternatively compounded in each isolator. Sampling involved wiping three surfaces (gloves, window, worktop), before and after a cleaning process. Exposure to ten antineoplastic drugs (cyclophosphamide, ifosfamide, dacarbazine, 5-FU, methotrexate, gemcitabine, cytarabine, irinotecan, doxorubicine and ganciclovir) was assessed on wipes by LC-MS/MS analysis. Contamination rates were compared using a Chi2 test and drug amounts by a Mann-Whitney test. Significance was defined for p<0.05. Overall contamination was lower in the \"Phaseal\" isolator than in the \"Standard\" isolator (12.24% vs. 26.39%; p < 0.0001) although it differed according to drug. Indeed, the contamination rates of gemcitabine were 49.3 and 43.4% (NS) for the Standard and Phaseal isolators, respectively, whereas for ganciclovir, they were 54.2 and 2.8% (p<0.0001). Gemcitabine amounts were 220.6 and 283.6 ng for the Standard and Phaseal isolators (NS), and ganciclovir amounts were 179.9 and 2.4 ng (p<0.0001). This study confirms that using a CSTD may significantly decrease the chemical contamination of barrier isolators compared to standard devices for some drugs, although it does not eliminate contamination totally.
Cost-Effectiveness Analysis of Five Competing Strategies for the Management of Multiple Recurrent Community-Onset Clostridium difficile Infection in France
Clostridium difficile infection (CDI) is characterized by high rates of recurrence, resulting in substantial health care costs. The aim of this study was to analyze the cost-effectiveness of treatments for the management of second recurrence of community-onset CDI in France. We developed a decision-analytic simulation model to compare 5 treatments for the management of second recurrence of community-onset CDI: pulsed-tapered vancomycin, fidaxomicin, fecal microbiota transplantation (FMT) via colonoscopy, FMT via duodenal infusion, and FMT via enema. The model outcome was the incremental cost-effectiveness ratio (ICER), expressed as cost per quality-adjusted life year (QALY) among the 5 treatments. ICERs were interpreted using a willingness-to-pay threshold of €32,000/QALY. Uncertainty was evaluated through deterministic and probabilistic sensitivity analyses. Three strategies were on the efficiency frontier: pulsed-tapered vancomycin, FMT via enema, and FMT via colonoscopy, in order of increasing effectiveness. FMT via duodenal infusion and fidaxomicin were dominated (i.e. less effective and costlier) by FMT via colonoscopy and FMT via enema. FMT via enema compared with pulsed-tapered vancomycin had an ICER of €18,092/QALY. The ICER for FMT via colonoscopy versus FMT via enema was €73,653/QALY. Probabilistic sensitivity analysis with 10,000 Monte Carlo simulations showed that FMT via enema was the most cost-effective strategy in 58% of simulations and FMT via colonoscopy was favored in 19% at a willingness-to-pay threshold of €32,000/QALY. FMT via enema is the most cost-effective initial strategy for the management of second recurrence of community-onset CDI at a willingness-to-pay threshold of €32,000/QALY.
In vitro assessment of the influence of intravenous extension set materials on insulin aspart drug delivery
Insulin is a frequently prescribed drug in hospitals and is usually administered by syringe pumps with an extension line which can be made of various materials. Two insulin solutions were studied: an insulin analogue, Novorapid® which contains insulin aspart and two phenolic preservatives (e.g. phenol and metacresol) and Umuline rapide® with human insulin and metacresol as preservative. Some studies have indicated interactions between insulin, polyvinyl chloride (PVC) and polyethylene (PE). The aim of this work was to study such interactions between Novorapid® or Umuline rapide® and infusion extension line materials (PVC, PE and coextruded (PE/PVC)). Insulin solution at 1 IU/mL was infused at 2 mL/h over 24 hours with 16 different extension lines (8 in PVC, 3 in PE and 5 in PE/PVC). Ultra-Fast Liquid Chromatography with diode array detection (UFLC-DAD) was performed to quantify insulin (human and aspart) and preservatives (metacresol and phenol). Limited human insulin sorption was observed thirty minutes after the onset of infusion: 24.3 ± 12.9%, 3.1 ± 1.6% and 18.6 ± 10.0% for PVC, PE and PE/PVC respectively. With insulin aspart, sorption of about 5% was observed at the onset of infusion for all materials. However, there were interactions between phenol and especially metacresol with PVC, but no interactions with PE and PE/PVC. This study shows that insulin interacts with PVC, PE and PE/PVC at the onset of infusion. It also demonstrates that insulin preservatives interact with PVC, which may result in problems of insulin conservation and conformation. Some more studies are required to understand the clinical impact of the latter during infusion.
Environmentally responsible use of hospital infusion systems: a systematic review of the literature
BackgroundThe healthcare sector produces significant amounts of waste and harmful substances and consumes large amounts of energy; hence, it is also involved in the move towards sustainability. Plastics are everywhere in hospitals (especially in medical devices used for infusion) and contribute significantly to greenhouse gas emissions. The objective was to review the scientific literature on ways of making in-hospital infusion practices more environmentally friendly.MethodsThe literature data were reviewed systematically and independently by two investigators and reported in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Any differences of opinion were resolved by a third investigator. Four online databases (PubMed, Embase, ScienceDirect and Web of Science) were searched for articles published in English or French between 1 January 2004 and 31 December 2024. Only publications that address sustainable development and infusion medical devices were included. The following data were extracted: country, hospital department(s), and the study’s objectives, methods, main results and conclusions. The robustness of the selected studies was assessed using the Mixed Methods Appraisal Tool.ResultsIn all, 1938 publications were screened, and eight were included. Four publications concerned overconsumption and/or waste analysis, one compared single-use devices with reusable devices, and three were concerned with intravenous drug administration and wastage. The topics addressed in life cycle assessments were procurement, supply, storage, overconsumption of medical devices, the wastage of intravenous drugs and waste management.ConclusionThe results highlighted some areas for improvement at various points in the medical device life cycle—from manufacturing to recycling. Collaboration between hospital stakeholders is essential for the promotion of environmentally friendly infusion practices.
Drug Incompatibilities and Complex Assemblies: Let Us Remain Vigilant!
Background/Objectives: Multi-lumen devices that limit physicochemical incompatibilities (PCIs) are frequently used in neonatal intensive care units where premature infants receive numerous infusions. The aim of the study was to investigate a PCI that occurred despite the use of a device of this type (EDELVAISS® Multiline NEO, Doran International, Toussieu, France). Case Summary: A 7-week-old preterm infant received ganciclovir at therapeutic dosage for cytomegalovirus (CMV) infection. After the fifth administration of ganciclovir, a PCI occurred, leading to a white precipitate. The peripheral inserted central catheter (PICC) (PREMICATH®2Fr, Vygon, Ecouen, France) had to be replaced. Laboratory reproduction of the administrations during 72 h, nuclear magnetic resonance (NMR) analysis and particle counting were carried out to analyse the occurrence of events leading to PCIs. The precipitate was linked to a PCI of parenteral nutrition associated with a dilution error of ganciclovir (omission of a 10-fold dilution step, resulting in ganciclovir being administered at 30 mg/L instead of 3 mg/L). Due to the presence of lipids in the parenteral nutrition, visual detection of the white precipitate was difficult. Conclusions: Multi-lumen infusion devices limit but do not prevent the occurrence of PCIs, particularly in the event of a preparation error. Despite the use of this type of device, great vigilance is still required, particularly with regard to prescription analysis and reconstitution procedures.
Effectiveness of in-Line Filters to Completely Remove Particulate Contamination During a Pediatric Multidrug Infusion Protocol
The large number of drugs administered simultaneously to neonates and children in hospital results in the formation of particles that are potentially infused. We have investigated the ability of IV in-line filters to eliminate particulate matter from multidrug infusion lines and so prevent contamination. The impact on particle occurrence of the internal volume of the IV line below the in-line filter was then evaluated. The multidrug therapy given to children was reproduced with and without in-line filtration. Three combinations with a filter were tested to vary the internal volume (V) between the filter and the catheter egress. The catheter was then connected to a dynamic particle count to evaluate the particulate matter potentially administered to children during infusion. The introduction of in-line filters led to a significant reduction in overall particulate matter, from 416,974 [208,479–880,229] to 7,551 [1,985–11,287] particles (p < 0.001). Larger particles of ≥10 and 25 µm were also significantly reduced. Adding an extension set to the egress of the in-line filter (V = 1.7 mL) caused a significant increase in particulate contamination for both. This study showed that in-line filtration is an effective tool in preventing particle administration to patients. Their position in the infusion in-line is therefore important because of its impact on internal volume and drug particle formation.
Evaluation of the Impact of Infusion Set Design on the Particulate Load Induced by Vancomycin–Piperacillin/Tazobactam Incompatibility
Introduction: Drug incompatibilities are among the most common medication errors in intensive care units. A precipitate can form and block the catheter or cause an adverse event in the patient. Intensive care units have implemented various strategies for limiting the occurrence of these incompatibilities, which have already been studied in vitro under standardized conditions. The objective of the present in vitro study was to continue these assessments by determining the impact of the infusion line geometry and the drugs’ position in the infusion set-up on the prevention of vancomycin–piperacillin/tazobactam incompatibility. Methods: Infusion lines with a different common volume, a multilumen medical infusion device, a dilute vancomycin solution, and separate infusions of incompatible drugs were evaluated separately. The infusion line outlet was connected to a dynamic particle counter. Results: Reducing the common volume, using multilumen medical devices, or spacing out the two incompatible drugs on the infusion line did not prevent the occurrence of a significant particulate load. Only dilution of the vancomycin solution was associated with a significantly lower particulate load and the absence of drug incompatibility. Conclusions: Our results show that under specific conditions, it is possible to reduce particulate contamination considerably.