Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
3 result(s) for "Oladimeji, Akinola Emmanuel"
Sort by:
Novel arthrometer for quantitative clinical examination of the knee in three planes: Safety, reliability, minimum detectable changes, and side-to-side differences in healthy subjects
Physical examination of the knee joint is used to diagnose the type and severity of knee ligament injury; however, these exams are qualitative and subjective. To perform common physical examinations, we developed an arthrometer which quantitatively measures the load–displacement response in anterior-posterior (AP) translation, internal-external rotation (IER) and varus-valgus (VV) rotation. Here we describe safety, reliability, minimum detectable changes (MDCs), and absolute side-to-side differences in twenty young, healthy subjects (ten male, ten female, mean age: 28 ± 6 years). The arthrometer consists of an instrumented mechanical linkage, a force-moment sensor, and software for real-time visualization and recording of the load–displacement responses. During testing, the subject sits reclined in a chair with their knee fixed at 30° of flexion. Two examiners tested both knees of each subject twice to assess reliability via intraclass correlation coefficients (ICC). All subjects completed the test protocol with minimal pain and stated that they would volunteer to be tested again. Each knee required on average five minutes to test. All intra-test reliabilities were excellent (≥0.91). Intra-examiner reliabilities ranged from good to excellent (0.62–0.89), and inter-examiner reliabilities were good to excellent (≥0.72). MDCs for repeat measures were ≤ 4.5 mm, 4.6°, and 2.3° for AP, IER, and VV, respectively. The absolute side-to-side differences for this cohort averaged 3.8 mm in AP, 5.5° in IER, and 2.2° in VV. Our arthrometer was safe, testing was time-efficient, and MDCs in our cohort of healthy subjects support utilization of this device for clinical research.