Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
2 result(s) for "Padma, Srivani"
Sort by:
Fiber Bragg Grating based bite force measurement
The present study reports an in vivo, novel methodology for the dynamic measurement of the bite force generated by individual tooth using a Fiber Bragg Grating Bite Force Recorder (FBGBFR). Bite force is considered as one of the major indicators of the functional state of the masticatory system, which is dependent on the craniomandibular structure comprising functional components such as muscles of mastication, joints and teeth. The proposed FBGBFR is an intra-oral device, developed for the transduction of the bite force exerted at the occlusal surface, into strain variations on a base plate, which in turn is sensed by the FBG sensor bonded over it. The FBGBFR is calibrated against a Micro Universal Testing Machine (UTM) for 0–900N range and the resolution of the developed FBGBFR is found to be 0.54N. 36 volunteers (20 males and 16 females) performed the bite force measurement test at molar, premolar and incisor tooth on either side of the dental arch and the obtained results show clinically relevant bite forces varying from 176N to 635N. The bite forces obtained from the current study for a substantial sample size, show that the bite forces increases along the dental arch from the incisors towards the molars and are found to be higher in male than in female. The FBG sensor element utilized in FBGBFR is electrically passive, which makes it a safe in vivo intra-oral device. Hence the FBGBFR is viable to be employed in clinical studies on biomechanics of oral function.
Fabrication of GaN/InGaN MQW blue light emitting diode
GaN/InGaN Multiple Quantum Well LED structures were indigenously grown by MOCVD system on c-plane (0001) sapphire substrate. Blue LEDs at chip level were fabricated with various chip sizes. I-V characteristics were measured for the fabricated chips.