Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
112
result(s) for
"Pantic, E."
Sort by:
DarkSide-20k: A 20 tonne two-phase LAr TPC for direct dark matter detection at LNGS
2018
.
Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LAr TPC) with an active (fiducial) mass of 23 t (20 t). This paper describes a preliminary design for the experiment, in which the DarkSide-20k LAr TPC is deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). This preliminary design provides a baseline for the experiment to achieve its physics goals, while further development work will lead to the final optimization of the detector parameters and an eventual technical design. Operation of DarkSide-50 demonstrated a major reduction in the dominant
39
Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of
>
3
×
10
9
is achievable. This, along with the use of the veto system and utilizing silicon photomultipliers in the LAr TPC, are the keys to unlocking the path to large LAr TPC detector masses, while maintaining an experiment in which less than
<
0
.
1
events (other than
ν
-induced nuclear recoils) is expected to occur within the WIMP search region during the planned exposure. DarkSide-20k will have ultra-low backgrounds than can be measured
in situ
, giving sensitivity to WIMP-nucleon cross sections of
1
.
2
×
10
-
47
cm
2
(
1
.
1
×
10
-
46
cm
2
) for WIMPs of 1 TeV/c
2
(10 TeV/c
2
) mass, to be achieved during a 5 yr run producing an exposure of 100 t yr free from any instrumental background.
Journal Article
Search for low mass dark matter in DarkSide-50: the bayesian network approach
2023
We present a novel approach for the search of dark matter in the DarkSide-50 experiment, relying on Bayesian Networks. This method incorporates the detector response model into the likelihood function, explicitly maintaining the connection with the quantity of interest. No assumptions about the linearity of the problem or the shape of the probability distribution functions are required, and there is no need to morph signal and background spectra as a function of nuisance parameters. By expressing the problem in terms of Bayesian Networks, we have developed an inference algorithm based on a Markov Chain Monte Carlo to calculate the posterior probability. A clever description of the detector response model in terms of parametric matrices allows us to study the impact of systematic variations of any parameter on the final results. Our approach not only provides the desired information on the parameter of interest, but also potential constraints on the response model. Our results are consistent with recent published analyses and further refine the parameters of the detector response model.
Journal Article
Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment
2015
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.
Journal Article
Separating 39Ar from 40Ar by cryogenic distillation with Aria for dark-matter searches
2021
Aria is a plant hosting a 350m cryogenic isotopic distillation column, the tallest ever built, which is being installed in a mine shaft at Carbosulcis S.p.A., Nuraxi-Figus (SU), Italy. Aria is one of the pillars of the argon dark-matter search experimental program, lead by the Global Argon Dark Matter Collaboration. It was designed to reduce the isotopic abundance of 39Ar in argon extracted from underground sources, called Underground Argon (UAr), which is used for dark-matter searches. Indeed, 39Ar is a β-emitter of cosmogenic origin, whose activity poses background and pile-up concerns in the detectors. In this paper, we discuss the requirements, design, construction, tests, and projected performance of the plant for the isotopic cryogenic distillation of argon. We also present the successful results of the isotopic cryogenic distillation of nitrogen with a prototype plant.
Journal Article
Production, quality assurance and quality control of the SiPM Tiles for the DarkSide-20k Time Projection Chamber
2025
The DarkSide-20k dark matter direct detection experiment will employ a
21
m
2
silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called
Tiles
, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout.
16
Tiles are further grouped into
Photo-Detector Units
(PDUs). This paper details the production of the Tiles and the Quality Assurance and Quality Control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision die attaching, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.
Journal Article
SOX: Short distance neutrino Oscillations with BoreXino
by
Pallavicini, M.
,
Sotnikov, A.
,
Wojcik, M.
in
Antineutrinos
,
Astrophysics
,
Background radiation
2013
A
bstract
The very low radioactive background of the Borexino detector, its large size, and the well proved capability to detect both low energy electron neutrinos and antineutrinos make an ideal case for the study of short distance neutrino oscillations with artificial sources at Gran Sasso.
This paper describes the possible layouts of
51
Cr (
ν
e
) and
144
Ce-
144
Pr
source experiments in Borexino and shows the expected sensitivity to eV mass sterile neutrinos for three possible different phases of the experiment. Expected results on neutrino magnetic moment, electroweak mixing angle, and couplings to axial and vector currents are shown too.
Journal Article
Constraints on directionality effect of nuclear recoils in a liquid argon time projection chamber
2024
The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils produced in a target material from the WIMP elastic scattering. The experimental identification of the direction of the WIMP-induced nuclear recoils is a crucial asset in this field, as it enables unmistakable modulation signatures for dark matter. The Recoil Directionality (ReD) experiment was designed to probe for such directional sensitivity in argon dual-phase time projection chambers (TPC), that are widely considered for current and future direct dark matter searches. The TPC of ReD was irradiated with neutrons at the INFN Laboratori Nazionali del Sud. Data were taken with nuclear recoils of known directions and kinetic energy of 72 keV, which is within the range of interest for WIMP-induced signals in argon. The direction-dependent liquid argon charge recombination model by Cataudella et al. was adopted and a likelihood statistical analysis was performed, which gave no indications of significant dependence of the detector response to the recoil direction. The aspect ratio
R
of the initial ionization cloud is
R
<
1.072
with 90 % confidence level.
Journal Article
EURECA — the European future of cryogenic dark matter searches
2006
EURECA (European Underground Rare Event Calorimeter Array) is a new project, searching for dark matter, with largely the present groups of the CRESST and EDELWEISS experiments and already a few new groups. The aim is to explore scalar cross sections in the 10−9 - 10−10 pico-barn region with a target mass of up to one tonne. A major advantage of EURECA is our planned use of more that just one target material (multi target experiment for WIMP identification). In preparation for this large-scale experiment, R&D for EURECA is provided through the current phases of CRESST and EDELWEISS.
Journal Article
The CRESST dark matter search
2008
CRESST is a WIMP dark matter search using scintillating CaWO4 cryogenic detectors with active background suppression. First results obtained in the commissioning run are presented.
Journal Article
The DarkSide Experiment: Present Status and Future
2017
DarkSide is a multi-stage program devoted to direct searches of Dark Matter particles with detectors based on double phase liquid Argon Time Projection Chamber. The DarkSide-50 setup is running underground at the Laboratori Nazionali del Gran Sasso. First it was operated with Atmospheric Argon and during that run (1422 ± 67) kg×d of truly background-free exposure has been accumulated. Obtained data made it possible to set a 90% C.L. upper limit on the WIMP-nucleon cross section of 6.1 × 10−44 cm2 (for a WIMP mass of 100 GeV/c2). Presently the detector is filled with Underground Argon, which is depleted in 39Ar by a factor of (1.4 ± 0.2)×103 with respect to Atmospheric Argon. Acquired so far (2616 ± 43) kg×d (71 live days) in combination with the data from the Atmospheric Argon run give us the 90% C.L. upper limit on the WIMP-nucleon spin-independent cross section of 2.0×10−44 cm2 for a WIMP mass of 100 GeV/c2. Up to date this is the best limit obtained with an argon target.
Journal Article