Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
2
result(s) for
"Pedretti, Stefano, MD"
Sort by:
Refractory ventricular tachycardia caused by inflow cannula mechanical injury in a patient with left ventricular assist device: Catheter ablation and pathological findings
by
Bonacina, Edgardo, MD
,
Frigerio, Maria, MD
,
Lunati, Maurizio, MD
in
Ablation
,
Cardiac arrhythmia
,
Cardiac pathology
2017
Abstract In patients with left ventricular assist device (LVAD), a minority of post-operative ventricular tachycardias (VTs) is caused by contact between the inflow cannula and the endocardium. Currently, electrophysiologic characteristics and pathologic features of this condition are lacking. We report on a case of a successfully ablated mechanical VT. After VT recurrence, heart transplantation took place. Pathologic observations were consistent with direct tissue injury and inflammation, eventually contributing to persisting arrhythmias. Radiofrequency catheter ablation can be a safe and effective option to treat arrhythmias caused by inflow cannula interference in the short term, although a high recurrence rate is expected.
Journal Article
A case of premature ventricular contractions, ventricular tachycardia, and arrhythmic storm induced by right ventricular pacing during cardiac resynchronization therapy: Electrophysiological mechanism and catheter ablation
by
Vargiu, Sara, MD
,
Paolucci, Marco, MD
,
Pedretti, Stefano, MD
in
Ablation
,
Ablation (Surgery)
,
Arrhythmia mechanism
2015
Abstract A 77-year-old man with ischemic cardiomyopathy and a cardiac resynchronization therapy-defibrillator (CRT-D) device came to our attention due to incessant ventricular tachycardia and multiple implantable cardioverter defibrillator (ICD) shocks. An electrocardiogram showed non-sustained monomorphic ventricular tachycardias (NSVTs) constantly occurring after each biventricular stimulation. During an electrophysiological study, NSVTs reproducibly recurred only after right ventricular (RV) pacing; LV pacing did not induce any NSVTs. The activation map was consistent with a localized reentry at the interventricular septum, and a double exit; at the LV exit site, a single radiofrequency energy application immediately interrupted the occurrence of the NSVTs. Current evidence supports LV pacing to be pro-arrhythmogenic in few CRT patients. This unusual case shows that RV pacing during CRT could produce frequent ventricular arrhythmias and arrhythmic storm. Catheter ablation can be considered an effective therapeutic option, especially when CRT maintenance is highly advisable.
Journal Article