Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
10
result(s) for
"Penttilä, S.I."
Sort by:
New search for mirror neutron regeneration
2019
The possibility of relatively fast neutron oscillations into a mirror neutron state is not excluded experimentally when a mirror magnetic field is considered. Direct searches for the disappearance of neutrons into mirror neutrons in a controlled magnetic field have previously been performed using ultracold neutrons, with some anomalous results reported. We describe a technique using cold neutrons to perform a disappearance and regeneration search, which would allow us to unambiguously identify a possible oscillation signal. An experiment using the existing General Purpose-Small Angle Neutron Scattering instrument at the High Flux Isotope Reactor at Oak Ridge National Laboratory will have the sensitivity to fully explore the parameter space of prior ultracold neutron searches and confirm or refute previous claims of observation. This instrument can also conclusively test the validity of recently suggested oscillation-based explanations for the neutron lifetime anomaly.
Journal Article
Status of the UCN τ experiment
2019
The neutron is the simplest nuclear system that can be used to probe the structure of the weak interaction and search for physics beyond the standard model. Measurements of neutron lifetime and β-decay correlation coefficients with precisions of 0.02% and 0.1%, respectively, would allow for stringent constraints on new physics. The UCNτ experiment uses an asymmetric magneto-gravitational UCN trap with in situ counting of surviving neutrons to measure the neutron lifetime, τ n = 877.7s (0.7s) stat (+0.4/−0.2s) sys . We discuss the recent result from UCNτ, the status of ongoing data collection and analysis, and the path toward a 0.25 s measurement of the neutron lifetime with UCNτ.
Journal Article
On the measurement of the neutron lifetime using ultracold neutrons in a vacuum quadrupole trap
2005
We present a conceptual design for an experiment to measure the neutron lifetime (~886 s) with an accuracy of 10(-4). The lifetime will be measured by observing the decay rate of a sample of ultracold neutrons (UCN) confined in vacuum in a magnetic trap. The UCN collaboration at Los Alamos National Laboratory has developed a prototype UCN source that is expected to produce a bottled UCN density of more than 100/cm(3) [1]. The availability of such an intense source makes it possible to approach the measurement of the neutron lifetime in a new way. We argue below that it is possible to measure the neutron lifetime to 10(-4) in a vacuum magnetic trap. The measurement involves no new technology beyond the expected UCN density. If even higher densities are available, the experiment can be made better and/or less expensive. We present the design and methodology for the measurement. The slow loss of neutrons that have stable orbits, but are not energetically trapped would produce a systematic uncertainty in the measurement. We discuss a new approach, chaotic cleaning, to the elimination of quasi-neutrons from the trap by breaking the rotational symmetry of the quadrupole trap. The neutron orbits take on a chaotic character and mode mixing causes the neutrons on the quasi-bound orbits to leave the trap.
Journal Article
Precision neutron polarimetry for neutron beta decay
2005
The abBA collaboration is developing a new type of field-expansion spectrometer for a measurement of the three correlation coefficients a, A, and B and the shape parameter b. The measurement of A and B requires precision neutron polarimetry. We will polarize a pulsed cold neutron beam from the SNS using a (3)He neutron spin filter. The well-known polarizing cross section for n-(3)He has a 1/v dependence, where v is the neutron velocity, which is used to determine the absolute beam polarization through a time-of-flight (TOF) measurement. We show that by measuring the TOF dependence of A and B, the coefficients and the neutron polarization can be determined with a small loss of the statistical precision and with negligible systematic error. We conclude that it is possible to determine the neutron polarization averaged over a long run in the neutron beta decay experiment with a statistical error less than 10(-4). We discuss various sources of systematic uncertainty in the measurement of A and B and conclude that the fractional systematic errors are less than 2 × 10(-4).
Journal Article
Measurement of neutron decay parameters - The abBA experiment
by
Hersmann, F.W.
,
Jones, G.L.
,
Bowman, J.D.
in
Beta decay
,
CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS
,
Decay
2005
We are developing an experiment to measure the correlations a, A, and B, and the Fierz interference term b in neutron decay, with a precision of approximately 10(-4). The experiment uses an electromagnetic spectrometer in combination with two large-area segmented silicon detectors to detect the proton and electron from the decay in coincidence, with 4π acceptance for both particles. For the neutron-polarization-dependent observables A and B, precision neutron polarimetry is achieved through the combination of a pulsed neutron beam, under construction at the SNS, and a polarized (3)He neutron polarizer. Measuring a and A in the same apparatus provides a redundant determination of λ = gA/gV . Uncertainty in λ dominates the uncertainty of CKM unitarity tests.
Journal Article
Detector development for the abBA experiment
by
Penttila, S.I.
,
Seo, P.N.
,
Wilburn, W.S.
in
Beta decay
,
CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS
,
Correlation analysis
2005
We have developed a new type of field-expansion spectrometer to measure the neutron beta decay correlations (a, b, B, and A). A precision measurement of these correlations places stringent requirements on charged particle detectors. The design employs large area segmented silicon detectors to detect both protons and electrons in coincidence. Other requirements include good energy resolution (< 5 keV), a thin dead layer to allow observation of 30-keV protons, fast timing resolution (~1 ns) to reconstruct electron-backscattering events, and nearly unity efficiency. We report results of testing commercially available surface-barrier silicon detectors for energy resolution and timing performance, and measurement of the dead-layer thickness of ion-implanted silicon detectors with a 3.2 MeV alpha source.
Journal Article
New pulsed cold neutron beam line for fundamental nuclear physics at LANSCE
by
Gericke, M.
,
Bowman, J.D.
,
Peralta, G.
in
Gamma rays
,
hydrogen moderator
,
INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
2005
The NPDGamma collaboration has completed the construction of a pulsed cold neutron beam line on flight path12 at the Los Alamos Neutron Science Center (LANSCE). We describe the new beam line and characteristics of the beam. We report results of the moderator brightness and the guide performance measurements. FP12 has the highest pulsed cold neutron intensity for nuclear physics in the world.
Journal Article
Measurement of parity violation in np capture: the NPDGamma experiment
2005
The NPDGamma experiment will measure the parity-violating directional gamma ray asymmetry A γ in the reaction [Formula: see text]. Ultimately, this will constitute the first measurement in the neutron-proton system that is sensitive enough to challenge modern theories of nuclear parity violation, providing a theoretically clean determination of the weak pion-nucleon coupling. A new beam-line at the Los Alamos Neutron Science Center (LANSCE) delivers pulsed cold neutrons to the apparatus, where they are polarized by transmission through a large volume polarized (3)He spin filter and captured in a liquid para-hydrogen target. The 2.2 MeV gamma rays from the capture reaction are detected in an array of CsI(Tl) scintillators read out by vacuum photodiodes operated in current mode. We will complete commissioning of the apparatus and carry out a first measurement at LANSCE in 2004-05, which would provide a statistics-limited result for A γ accurate to a standard uncertainty of ±5 × 10(-8) level or better, improving on existing measurements in the neutron-proton system by a factor of 4. Plans to move the experiment to a reactor facility, where the greater flux would enable us to make a measurement with a standard uncertainty of ±1 × 10(-8), are actively being pursued for the longer term.
Journal Article