Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
91 result(s) for "Picchi, P"
Sort by:
Experimental search for the “LSND anomaly” with the ICARUS detector in the CNGS neutrino beam
We report an early result from the ICARUS experiment on the search for a ν μ → ν e signal due to the LSND anomaly. The search was performed with the ICARUS T600 detector located at the Gran Sasso Laboratory, receiving CNGS neutrinos from CERN at an average energy of about 20 GeV, after a flight path of ∼730 km. The LSND anomaly would manifest as an excess of ν e events, characterized by a fast energy oscillation averaging approximately to with probability . The present analysis is based on 1091 neutrino events, which are about 50 % of the ICARUS data collected in 2010–2011. Two clear ν e events have been found, compared with the expectation of 3.7±0.6 events from conventional sources. Within the range of our observations, this result is compatible with the absence of a LSND anomaly. At 90 % and 99 % confidence levels the limits of 3.4 and 7.3 events corresponding to oscillation probabilities and are set respectively. The result strongly limits the window of open options for the LSND anomaly to a narrow region around (Δ m 2 ,sin 2 (2 θ )) new =(0.5 eV 2 ,0.005), where there is an overall agreement (90 % CL) between the present ICARUS limit, the published limits of KARMEN and the published positive signals of LSND and MiniBooNE Collaborations.
Precise 3D Track Reconstruction Algorithm for the ICARUS T600 Liquid Argon Time Projection Chamber Detector
Liquid Argon Time Projection Chamber (LAr TPC) detectors offer charged particle imaging capability with remarkable spatial resolution. Precise event reconstruction procedures are critical in order to fully exploit the potential of this technology. In this paper we present a new, general approach to 3D reconstruction for the LAr TPC with a practical application to the track reconstruction. The efficiency of the method is evaluated on a sample of simulated tracks. We present also the application of the method to the analysis of stopping particle tracks collected during the ICARUS T600 detector operation with the CNGS neutrino beam.
Precision measurement of the neutrino velocity with the ICARUS detector in the CNGS beam
A bstract During May 2012, the CERN-CNGS neutrino beam has been operated for two weeks for a total of ~1.8 × 10 17 p.o.t., with the proton beam made of bunches, few ns wide and separated by 100 ns. This beam structure allows a very accurate time of flight measurement of neutrinos from CERN to LNGS on an event-by-event basis. Both the ICARUS-T600 PMT-DAQ and the CERN-LNGS timing synchronization have been substantially improved for this campaign, taking advantage of additional independent GPS receivers, both at CERN and LNGS as well as of the deployment of the “White Rabbit” protocol both at CERN and LNGS. The ICARUS-T600 detector has collected 25 beam-associated events; the corresponding time of flight has been accurately evaluated, using all different time synchronization paths. The measured neutrino time of flight is compatible with the arrival of all events with speed equivalent to the one of light: the difference between the expected value based on the speed of light and the measured value is δt = tof c −tof ν  = 0.10 ± 0.67 stat.  ± 2.39 syst.  ns. This result is in agreement with the value previously reported by the ICARUS Collaboration, δt  = 0.3 ± 4.9 stat.  ± 9.0 syst.  ns, but with improved statistical and systematic accuracy.
Dissolution of calcium pyrophosphate crystals by polyphosphates: an in vitro and ex vivo study
OBJECTIVE To determine the dissolving ability (DA) of linear pentasodium tripolyphosphate (PSTP), cyclic trisodium metaphosphate (TSMP), polymeric sodium metaphosphate (SMP) on synthetic crystals of calcium pyrophosphate dihydrate (CPPD) and on crystalline aggregates of menisci from patients with chondrocalcinosis (CC). METHODS Synthetic CPPD crystals were mixed with phosphate buffered saline (PBS), which contained the different polyphosphates, for one hour at 37°C. The calcified menisci were obtained from the knees of four female patients with CPPD disease who underwent total arthroscopic meniscectomy for degenerative meniscal lesions. Meniscal cryosections and fragments were incubated in SMP (15 mg/ml PBS) at 37°C for one hour and 24 hours, respectively. Histological evaluation on meniscal samples after polyphosphate incubation was carried out by ordinary transmitted light microscopy and polarised light microscopy. The dissolution of CPPD crystals by polyphosphates was assessed by atomic absorption spectroscopy, which determined the amount of calcium liberated from synthetic crystals and meniscal fragments. Cytotoxicity of SMP was evaluated by tetrazolium salt assay and by an ultrastructural study on cultured chondrocytes. RESULTS SMP and PSTP showed higher DA on CPPD crystals than TSMP. Analysis of the DA values at increasing concentrations of SMP showed that a concentration of 15 mg/ml completely dissolved 2.0 mg CPPD crystals. The solution of meniscal CPPD crystals showed a significant increase of calcium concentration after three hours and 24 hours of SMP incubation (p=0.0001; Kruskal-Wallis analysis of variance) compared with fragments incubated in PBS control solution. Macroscopic and microscopic evaluation of meniscal specimens showed a notable reduction of CPPD deposits. A 50% inhibitory dose on cultured chondrocytes was reached at the maximum concentration of SMP used in this work (15 mg/ml); ultrastructural analysis did not show morphological alterations in the treated cells. CONCLUSION The results of this study indicate that linear polyphosphates are effective in dissolving both synthetic and ex vivo CPPD crystal aggregates. This suggests a potential therapeutic use for these molecules in the treatment of symptomatic CC.
Search for anomalies in the νe appearance from a νμ beam
We report an updated result from the ICARUS experiment on the search for ν μ → ν e anomalies with the CNGS beam, produced at CERN with an average energy of 20 GeV and traveling 730 km to the Gran Sasso Laboratory. The present analysis is based on a total sample of 1995 events of CNGS neutrino interactions, which corresponds to an almost doubled sample with respect to the previously published result. Four clear ν e events have been visually identified over the full sample, compared with an expectation of 6.4±0.9 events from conventional sources. The result is compatible with the absence of additional anomalous contributions. At 90 % and 99 % confidence levels, the limits to possible oscillated events are 3.7 and 8.3 respectively. The corresponding limit to oscillation probability becomes consequently 3.4×10 −3 and 7.6×10 −3 , respectively. The present result confirms, with an improved sensitivity, the early result already published by the ICARUS Collaboration.
Search for anomalies in the nu^sub e^ appearance from a nu^sub mu^ beam
We report an updated result from the ICARUS experiment on the search for ν ^sub [mu]^[arrow right]ν ^sub e^ anomalies with the CNGS beam, produced at CERN with an average energy of 20 GeV and traveling 730 km to the Gran Sasso Laboratory. The present analysis is based on a total sample of 1995 events of CNGS neutrino interactions, which corresponds to an almost doubled sample with respect to the previously published result. Four clear ν ^sub e^ events have been visually identified over the full sample, compared with an expectation of 6.4±0.9 events from conventional sources. The result is compatible with the absence of additional anomalous contributions. At 90 % and 99 % confidence levels, the limits to possible oscillated events are 3.7 and 8.3 respectively. The corresponding limit to oscillation probability becomes consequently 3.4×10^sup -3^ and 7.6×10^sup -3^, respectively. The present result confirms, with an improved sensitivity, the early result already published by the ICARUS Collaboration.
Measurement of the μ decay spectrum with the ICARUS liquid Argon TPC
Examples are given which prove the ICARUS detector quality through relevant physics measurements. We study the μ decay energy spectrum from a sample of stopping μ events acquired during the test run of the ICARUS T600 detector. This detector allows the spatial reconstruction of the events with fine granularity, hence, the precise measurement of the range and dE/dx of the μ with high sampling rate. This information is used to compute the calibration factors needed for the full calorimetric reconstruction of the events. The Michel \\(\\rho\\) parameter is then measured by comparison of the experimental and Monte Carlo simulated μ decay spectra, obtaining \\(\\rho = 0.72\\pm 0.06 \\textrm{(stat.)} \\pm 0.08 \\textrm{(syst.)}\\). The energy resolution for electrons below \\(\\sim 50\\) MeV is finally extracted from the simulated sample, obtaining \\((E^e_{\\textrm{meas}}-E^e_{\\text{MC}})/E^e_{MC} = 11\\% /\\sqrt{E\\textrm{[MeV]}} \\oplus 2\\%\\).
Measurement of through-going particle momentum by means of multiple scattering with the ICARUS T600 TPC
The ICARUS collaboration has demonstrated, following the operation of a 600 ton (T600) detector at shallow depth, that the technique based on liquid argon time projection chambers is now mature. The study of rare events, not contemplated in the standard model, can greatly benefit from the use of this kind of detectors. In particular, a deeper understanding of atmospheric neutrino properties will be obtained thanks to the unprecedented quality of the data ICARUS provides. However if we concentrate on the T600 performance, most of the νμ charged current sample will be partially contained, due to the reduced dimensions of the detector. In this article, we address the problem of how well we can determine the kinematics of events having partially contained tracks. The analysis of a large sample of atmospheric muons collected during the T600 test run demonstrates that, in case the recorded track is at least one meter long, the muon momentum can be reconstructed by an algorithm that measures the multiple Coulomb scattering along the particle’s path. Moreover, we show that momentum resolution can be improved by almost a factor two using an algorithm based on the Kalman filtering technique.