Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
29 result(s) for "Pignoli, Emanuele"
Sort by:
Ultraviolet C lamps for disinfection of surfaces potentially contaminated with SARS-CoV-2 in critical hospital settings: examples of their use and some practical advice
Background UltraViolet-C (UV-C) lamps may be used to supplement current hospital cleaning and disinfection of surfaces contaminated by SARS-CoV-2. Our aim is to provide some practical indications for the correct use of UV-C lamps. Methods We studied three UV-C lamps, measuring their spatial irradiance and emission over time. We quantify the error that is committed by calculating the irradiation time based exclusively on the technical data of the lamps or by making direct irradiance measurements. Finally, we tested specific dosimeters for UV-C. Results Our results show that the spatial emission of UV-C lamps is strongly dependent on the power of the lamps and on the design of their reflectors. Only by optimizing the positioning and calculating the exposure time correctly, is it possible to dispense the dose necessary to obtain SARS-CoV-2 inactivation. In the absence of suitable equipment for measuring irradiance, the calculated irradiation time can be underestimated. We therefore consider it precautionary to increase the calculated times by at least 20%. Conclusion To use UV-C lamps effectively, it is necessary to follow a few simple precepts when choosing, positioning and verifying the lamps. In the absence of instruments dedicated to direct verification of irradiance, photochromic UV-C dosimeters may represent a useful tool for easily verifying that a proper UV-C dose has been delivered.
Microscopic and Macroscopic Characterization of Hydrogels Based on Poly(vinyl-alcohol)–Glutaraldehyde Mixtures for Fricke Gel Dosimetry
In recent decades, hydrogels have emerged as innovative soft materials with widespread applications in the medical and biomedical fields, including drug delivery, tissue engineering, and gel dosimetry. In this work, a comprehensive study of the macroscopic and microscopic properties of hydrogel matrices based on Poly(vinyl-alcohol) (PVA) chemically crosslinked with Glutaraldehyde (GTA) was reported. Five different kinds of PVAs differing in molecular weight and degree of hydrolysis were considered. The local microscopic organization of the hydrogels was studied through the use of the 1H nuclear magnetic resonance relaxometry technique. Various macroscopic properties (gel fraction, water loss, contact angle, swelling degree, viscosity, and Young’s Modulus) were investigated with the aim of finding a correlation between them and the features of the hydrogel matrix. Additionally, an optical characterization was performed on all the hydrogels loaded with Fricke solution to assess their dosimetric behavior. The results obtained indicate that the degree of PVA hydrolysis is a crucial parameter influencing the structure of the hydrogel matrix. This factor should be considered for ensuring stability over time, a vital property in the context of potential biomedical applications where hydrogels act as radiological tissue-equivalent materials.
How Xylenol Orange and Ferrous Ammonium Sulphate Influence the Dosimetric Properties of PVA–GTA Fricke Gel Dosimeters: A Spectrophotometric Study
The development of Fricke gel (FG) dosimeters based on poly(vinyl alcohol) (PVA) as the gelling agent and glutaraldehyde (GTA) as the cross-linker has enabled significant improvements in the dose response and the stability over time of spatial radiation dose distributions. However, a standard procedure for preparing FG in terms of reagent concentrations is still missing in the literature. This study aims to investigate, by means of spectrophotometric analyses, how the sensitivity to the radiation dose and the range of linearity of the dose–response curve of PVA-GTA-FG dosimeters loaded with xylenol orange sodium salt (XO) are influenced by ferrous ammonium sulphate (FAS) and XO concentrations. Moreover, the effect of different concentrations of such compounds on self-oxidation phenomena in the dosimeters was evaluated. PVA-GTA-FG dosimeters were prepared using XO concentrations in the range 0.04–0.80 mM and FAS in the range 0.05–5.00 mM. The optical absorbance properties and the dose response of FG were investigated in the interval 0.0–42.0 Gy. The results demonstrate that the amount of FAS and XO determines both the sensitivity to the absorbed dose and the interval of linearity of the dose–response curve. The study suggests that the best performances of FG dosimeters for spectrophotometric analyses can be obtained using 1.00–0.40 mM and 0.200–0.166 mM concentrations of FAS and XO, respectively.
Baseline MRI-Radiomics Can Predict Overall Survival in Non-Endemic EBV-Related Nasopharyngeal Carcinoma Patients
Advanced stage nasopharyngeal cancer (NPC) shows highly variable treatment outcomes, suggesting the need for independent prognostic factors. This study aims at developing a magnetic resonance imaging (MRI)-based radiomic signature as a prognostic marker for different clinical endpoints in NPC patients from non-endemic areas. A total 136 patients with advanced NPC and available MRI imaging (T1-weighted and T2-weighted) were selected. For each patient, 2144 radiomic features were extracted from the main tumor and largest lymph node. A multivariate Cox regression model was trained on a subset of features to obtain a radiomic signature for overall survival (OS), which was also applied for the prognosis of other clinical endpoints. Validation was performed using 10-fold cross-validation. The added prognostic value of the radiomic features to clinical features and volume was also evaluated. The radiomics-based signature had good prognostic power for OS and loco-regional recurrence-free survival (LRFS), with C-index of 0.68 and 0.72, respectively. In all the cases, the addition of radiomics to clinical features improved the prognostic performance. Radiomic features can provide independent prognostic information in NPC patients from non-endemic areas.
Hadron Therapy, Magnetic Nanoparticles and Hyperthermia: A Promising Combined Tool for Pancreatic Cancer Treatment
A combination of carbon ions/photons irradiation and hyperthermia as a novel therapeutic approach for the in-vitro treatment of pancreatic cancer BxPC3 cells is presented. The radiation doses used are 0–2 Gy for carbon ions and 0–7 Gy for 6 MV photons. Hyperthermia is realized via a standard heating bath, assisted by magnetic fluid hyperthermia (MFH) that utilizes magnetic nanoparticles (MNPs) exposed to an alternating magnetic field of amplitude 19.5 mTesla and frequency 109.8 kHz. Starting from 37 °C, the temperature is gradually increased and the sample is kept at 42 °C for 30 min. For MFH, MNPs with a mean diameter of 19 nm and specific absorption rate of 110 ± 30 W/gFe3o4 coated with a biocompatible ligand to ensure stability in physiological media are used. Irradiation diminishes the clonogenic survival at an extent that depends on the radiation type, and its decrease is amplified both by the MNPs cellular uptake and the hyperthermia protocol. Significant increases in DNA double-strand breaks at 6 h are observed in samples exposed to MNP uptake, treated with 0.75 Gy carbon-ion irradiation and hyperthermia. The proposed experimental protocol, based on the combination of hadron irradiation and hyperthermia, represents a first step towards an innovative clinical option for pancreatic cancer.
Early detection of colorectal adenocarcinoma: a clinical decision support tool based on plasma porphyrin accumulation and risk factors
Background An increase in naturally-occurring porphyrins has been described in the blood of subjects bearing different kinds of tumors, including colorectal, and this is probably related to a systemic alteration of heme metabolism induced by tumor cells. The aim of our study was to develop an artificial neural network (ANN) classifier for early detection of colorectal adenocarcinoma based on plasma porphyrin accumulation and risk factors. Methods We measured the endogenous fluorescence of blood plasma in 100 colorectal adenocarcinoma patients and 112 controls using a conventional spectrofluorometer. Height, weight, personal and family medical history, use of alcohol, red meat, vegetables and tobacco were all recorded. An ANN model was built up from demographic data and from the integral of the fluorescence emission peak in the range 610–650 nm. We used the Receiver Operating Characteristic ( ROC ) curve to assess performance in distinguishing colorectal adenocarcinoma patients and controls. A liquid chromatography-high resolution mass spectrometry (LC-HRMS) analytical method was employed to identify the agents responsible for native fluorescence. Results The fluorescence analysis indicated that the integral of the fluorescence emission peak in the range 610–650 nm was significantly higher in colorectal adenocarcinoma patients than controls ( p  < 0.0001) and was weakly correlated with the TNM staging (Spearman’s rho = 0.224, p  = 0.011). LC-HRMS measurements showed that the agents responsible for the fluorescence emission were mainly protoporphyrin-IX (PpIX) and coproporphyrin-I (CpI). The overall accuracy of our ANN model was 88% (87% sensitivity and 90% specificity) with an area under the ROC curve of 0.83. Conclusions These results confirm that tumor cells accumulate a diagnostic level of endogenous porphyrin compounds and suggest that plasma porphyrin concentrations, indirectly measured through fluorescence analysis, may be useful, together with risk factors, as a clinical decision support tool for the early detection of colorectal adenocarcinoma. Our future efforts will be aimed at examining how plasma porphyrin accumulation correlates with survival and response to therapy.
Retrospective study of late radiation-induced damages after focal radiotherapy for childhood brain tumors
To study a robust and reproducible procedure to investigate a relation between focal brain radiotherapy (RT) low doses, neurocognitive impairment and late White Matter and Gray Matter alterations, as shown by Diffusion Tensor Imaging (DTI), in children. Forty-five patients (23 males and 22 females, median age at RT 6.2 years, median age at evaluations 11.1 years) who had received focal RT for brain tumors were recruited for DTI exams and neurocognitive tests. Patients' brains were parceled in 116 regions of interest (ROIs) using an available segmented atlas. After the development of an ad hoc, home-made, multimodal and highly deformable registration framework, we collected mean RT doses and DTI metrics values for each ROI. The pattern of association between cognitive scores or domains and dose or DTI values was assessed in each ROI through both considering and excluding ROIs with mean doses higher than 75% of the prescription. Subsequently, a preliminary threshold value of dose discriminating patients with and without neurocognitive impairment was selected for the most relevant associations. The workflow allowed us to identify 10 ROIs where RT dose and DTI metrics were significantly associated with cognitive tests results (p<0.05). In 5/10 ROIs, RT dose and cognitive tests were associated with p<0.01 and preliminary RT threshold dose values, implying a possible cognitive or neuropsychological damage, were calculated. The analysis of domains showed that the most involved one was the \"school-related activities\". This analysis, despite being conducted on a retrospective cohort of children, shows that the identification of critical brain structures and respective radiation dose thresholds is achievable by combining, with appropriate methodological tools, the large amount of data arising from different sources. This supported the design of a prospective study to gain stronger evidence.
Hypofractionated whole-breast radiotherapy in large breast size patients: is it really a resolved issue?
The purpose of this study was to evaluate the impact of breast size on acute and late side effects in breast cancer (BC) patients treated with hypofractionated radiotherapy (Hypo-RT). In this study we analyzed patients over 50 years with a diagnosis of early BC, candidate for Hypo-RT after conservative surgery. Acute and late skin toxicities were evaluated in accordance with the RTOG scale. Multivariable logistic analysis was performed using dosimetric/anatomical factors resulted associated with toxicity outcome in univariable analysis. Among patients treated between 2009 and 2015, 425 had at least 5 years of follow-up. At RT end, acute skin toxicity ≥ G2 and edema ≥ G2 occurred in 88 (20.7%) and 4 (0.9%) patients, respectively. The multivariable analysis showed association of skin toxicity with boost administration (p < 0.01), treated skin area (TSA) receiving more than 20 Gy (p = 0.027) and breast volume receiving 105% of the prescription dose (V105%) (p = 0.016), but not breast size. At 5 years after RT, fibrosis ≥ G1 occurred in 89 (20.9%) patients and edema ≥ G1 in 36 (8.5%) patients. Fibrosis resulted associated with breast volume ≥ 1000 cm3 (p = 0.04) and hypertension (p = 0.04). As for edema, multivariable logistic analysis showed a correlation with hypertension and logarithm of age, but not with boost administration. Breast volume had an unclear impact (p = 0.055). A recurrent association was found between acute and late toxicities and breast V105%, which is correlated with breast size. This may suggest that a more homogenous RT technique may be preferred for patients with larger breast size.
A multi-metric registration strategy for the alignment of longitudinal brain images in pediatric oncology
Survival of pediatric patients with brain tumor has increased over the past 20 years, and increasing evidence of iatrogenic toxicities has been reported. In follow-ups, images are acquired at different time points where substantial changes of brain morphology occur, due to childhood physiological development and treatment effects. To address the image registration complexity, we propose two multi-metric approaches (Mplus, Mdot), combining mutual information (MI) and normalized gradient field filter (NGF). The registration performance of the proposed metrics was assessed on a simulated dataset (Brainweb) and compared with those obtained by MI and NGF separately, using mean magnitude and mean angular errors. The most promising metric (Mplus) was then selected and tested on a retrospective dataset comprising 45 pediatric patients who underwent focal radiotherapy for brain cancer. The quality of the realignment was scored by a radiation oncologist using a perceived misalignment metric (PM). All patients but one were assessed as PM ≤ 2 (good alignment), but the remaining one, severely affected by hydrocephalus and pneumocephalus at the first MRI acquisition, scored PM = 5 (unacceptable). These preliminary findings suggest that Mplus might improve the registration accuracy in complex applications such as pediatric oncology, when data are acquired throughout the years of follow-up, and is worth investigating.
Real world feasibility of combining pembrolizumab with radiotherapy in early triple negative breast cancer
Introduction Real-world data on the feasibility and potential interaction of concurrent immunotherapy with radiation therapy (RT) remains limited. Herein, we investigated the safety profile of adjuvant pembrolizumab with concomitant RT given with curative intent in operable triple negative breast cancer (TNBC) patients. Materials and methods We conducted the INT 54/24 study to prospectively collect data from patients with operable TNBC treated with neoadjuvant chemotherapy plus pembrolizumab followed by surgery and adjuvant pembrolizumab with concomitant RT. A total dose of 40.05 Gy delivered in 15 fractions was prescribed to the breast or chest wall, with regional nodes and tumor bed boost administered as clinically indicated. The study endpoint was to assess both acute toxicity (as per Radiation Therapy Oncology Group scale) and the rate of discontinuation of RT and/or pembrolizumab. Results Among the 10 female patients with TNBC enrolled between January and October 2024, the median age was 58 years (range, 27–68 years). Seven patients (70%) presented with stage II disease, with all cases classified as grade 3. A median of 8 (range 4–9) cycles of neoadjuvant pembrolizumab were prescribed. Before RT, patients received a median of 3 (range 2–4) cycles of adjuvant pembrolizumab. Severe acute toxicity occurred in 2 cases. Specifically, G4 myositis led to permanent discontinuation of adjuvant pembrolizumab in one case, whereas G3 electrolyte imbalance caused definitive RT interruption and temporary discontinuation of adjuvant pembrolizumab in the second case. Only 2 patients experienced G2 skin erythema, with no treatment discontinuation. Conclusions Our findings show that concurrent RT and pembrolizumab is feasible with manageable toxicities, providing valuable support for clinicians in real-world practice beyond the selective context of clinical trials.