Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
26
result(s) for
"Radchenko, Roman"
Sort by:
Gas Turbine Intake Air Hybrid Cooling Systems and a New Approach to Their Rational Designing
by
Yang, Zongming
,
Mikielewicz, Dariusz
,
Radchenko, Mykola
in
Cooling
,
Energy efficiency
,
excessive refrigeration energy
2022
Gas turbine intake air cooling (TIAC) by exhaust gas heat recovery chillers is a general trend to improve turbine fuel efficiency at increased ambient temperatures. The high efficiency absorption lithium–bromide chillers of a simple cycle are the most widely used, but they are unable to cool inlet air lower than 15 °C. A two-stage hybrid absorption–ejector chillers were developed with absorption chiller as a high temperature stage and ejector chiller as a low temperature stage to subcool air from 15 °C to 10 °C and lower. A novel trend in TIAC by two-stage air cooling in hybrid chillers has been substantiated to provide about 50% higher annual fuel saving in temperate climate as compared with absorption cooling. A new approach to reduce practically twice design cooling capacity of absorption chiller due to its rational distribution with accumulating excessive refrigeration energy at decreased thermal loads to cover the picked demands and advanced design methodology based on it was proposed. The method behind this is issued from comparing a behavior of the characteristic curves of refrigeration energy required for TIAC with its available values according to various design cooling capacities to cover daily fluctuation of thermal loads at reduced by 15 to 20% design cooling capacity and practically maximum annual fuel reduction.
Journal Article
Advanced Method of Variable Refrigerant Flow (VRF) Systems Designing to Forecast On-Site Operation—Part 1: General Approaches and Criteria
by
Radchenko, Mykola
,
Radchenko, Roman
,
Trushliakov, Eugeniy
in
Air conditioning
,
air conditioning system
,
Analysis
2023
All the energetic management and controlling strategies in ambient air conditioning systems (ACS) are aimed to match design load to current needs. This might be achieved by determining a rational value of design thermal load without overestimation that can minimize its deviation from the actual values. The application of variable refrigerant flow (VRF) systems with speed-regulated compressors (SRC) is considered as the most advanced trend in building air conditioning due to the ability of SRCs to cover changeable heat loads without lowering their efficiency. The level of load regulation by SRC is evaluated as the ratio of the load range, regulated by SCR, to the overall design load range. With this, the range of actual changeable loads is usually supposed to be covered by SRC entirely while keeping the rest, unregulated, and load range unchangeable. However, to confirm this, the rest load range behind the regulated one should be investigated to estimate the efficiency of SRC operation. Therefore, the approach to dividing the overall thermal load range of ambient air conditioning into the ranges of changeable and unchangeable loads to compare with those covered by SRC is used. From this approach, the method of rational designing and shearing a design refrigeration capacity in response to current loading, based on the principle of two-stage ambient air conditioning, has been widened on the VRF systems to estimate the efficiency of SCR application. This was realized by imposing the load ranges regulated by SRC onto the ranges of changeable and unchangeable loads within the overall range of actual loading. The proposed innovative criteria and indicators for rational shearing the load ranges to match current duties and load level evaluation can reveal the reserves for improving the efficiency of SRC compressor operation and the ACS of VRF type as a whole.
Journal Article
Advanced Method of Variable Refrigerant Flow (VRF) System Design to Forecast on Site Operation—Part 3: Optimal Solutions to Minimize Sizes
by
Radchenko, Mykola
,
Radchenko, Roman
,
Trushliakov, Eugeniy
in
Air conditioning
,
air conditioning system
,
Composition
2023
Outdoor air conditioning systems (ACS) are used as autonomic systems as well as in combined outdoor and indoor ACS of the variable refrigerant flow (VRF) type, with variable speed compressors (VSC) as their advanced version. Methods for determining the optimal value of refrigeration capacity and providing the maximum rate of the summarized annual refrigeration energy generation increment, according to its needs at minimum compressor sizes and rational values, are applied to reveal the reserves for reducing the designed (installed) refrigeration capacity, thus enabling us to practically achieve maximum annual refrigeration energy generation as the primary criterion at the second stage of the general design methodology previously developed by the authors. The principle of sharing the total thermal load on the ACS between the ranges of changeable loads for outdoor air precooling, and a relatively stable load range for further processing air are used as its basis. According to this principle, the changeable thermal load range is chosen as the object for energy saving by recuperating the excessive refrigeration generated at lowered loading in order to compensate for the increased loads, thereby matching actual duties at a reduced designed refrigeration capacity. The method allows us to determine the corresponding level of regulated loads (LRL) of SRC and the load range of compressor operation to minimize sizes.
Journal Article
Energy Saving in Trigeneration Plant for Food Industries
by
Mikielewicz, Dariusz
,
Radchenko, Mykola
,
Radchenko, Roman
in
Cooling
,
Economic analysis
,
Energy efficiency
2022
The trigeneration plants for combined cooling, heating, and electricity supply, or integrated energy systems (IES), are mostly based on gas reciprocating engines. The fuel efficiency of gas reciprocating engines depends essentially on air intake temperatures. The transformation of the heat removed from the combustion engines into refrigeration is generally conducted by absorption lithium-bromide chillers (ACh). The peculiarity of refrigeration generation in food technologies is the use of chilled water of about 12 °C instead of 7 °C as the most typical for ACh. This leads to a considerable cooling potential not realized by ACh that could be used for cooling the engine intake air. A refrigerant ejector chiller (ECh) is the simplest in design, cheap, and can be applied as the low-temperature stage of a two-stage absorption-ejector chiller (AECh) to provide engine intake air cooling and increase engine fuel efficiency as result. The monitoring data on gas engine fuel consumption and power were analyzed in order to evaluate the effect of gas engine cyclic air cooling.
Journal Article
Advanced Method of Variable Refrigerant Flow (VRF) Systems Designing to Forecast Onsite Operation—Part 2: Phenomenological Simulation to Recoup Refrigeration Energy
by
Radchenko, Mykola
,
Radchenko, Roman
,
Trushliakov, Eugeniy
in
Air conditioning
,
air conditioning system
,
Composition
2023
This paper focuses on the application of speed-regulated compressors (SRCs) to cover changeable heat loads with high efficiency in conventional air conditioning systems (ACS) as well as in the more advanced variable refrigerant flow (VRF)-type outdoor and indoor ACS. In reality, an SRC is an oversized compressor, although it can operate efficiently at part loads. The higher the level of regulated loads (LRL) of the SRC, the more the compressor is oversized. It is preferable to reduce the size of the SRC by covering the peak loads and recouping the excessive refrigeration energy reserved at decreased actual loads within the range of regulated loads. Therefore, the range of changeable loads is chosen as the object to be narrowed by using the reserved refrigeration capacity. Thus, the general fundamental approach of dividing the overall heat load range of the ACS into the ranges with changeable and unchangeable loads, as previously developed by the authors, is applied for the range of primary changeable loads. Due to this innovative step, the principle of two-stage outdoor air conditioning according to changeable and unchangeable loads, also proposed by the authors, has been extended over the range of primary changeable loads to reduce the level of refrigeration capacity regulation and SRC size. To realize this, part of the changeable load range is offset by the reserved refrigeration capacity, leading to a reduction in the changeable load range and the SRC size by approximately 20% for temperate climatic conditions.
Journal Article
Cooling Cyclic Air of Marine Engine with Water-Fuel Emulsion Combustion by Exhaust Heat Recovery Chiller
by
Radchenko, Mykola
,
Radchenko, Roman
,
Kornienko, Victoria
in
Corrosion
,
Diesel engines
,
Energy efficiency
2022
The fuel efficiency of marine diesel engine as any combustion engine falls with raising the temperature of air at the suction of its turbocharger. Therefore, cooling the engine turbocharger intake air by recovering exhaust gas heat to refrigeration capacity is a very perspective trend in enhancing the fuel efficiency of marine diesel engines. The application of water-fuel emulsion (WFE) combustion enables the reduction of a low-temperature corrosion, and, as a result, provides deeper exhaust gas heat utilization in the exhaust gas boiler (EGB) to the much lower temperature of 90–110 °C during WFE instead of 150–170 °C when combusting conventional fuel oil. This leads to the increment of the heat extracted from exhaust gas that is converted to refrigeration capacity by exhaust heat recovery chiller for cooling engine turbocharger sucked air accordingly. We experimentally investigated the corrosion processes on the condensation surfaces of EGB during WFE combustion to approve their intensity suppression and the possibility of deeper exhaust gas heat utilization. The fuel efficiency of cooling intake air at the suction of engine turbocharger with WFE combustion by exhaust heat recovery chiller was estimated along the voyage line Mariupol–Amsterdam–Mariupol. The values of available refrigeration capacity of exhaust heat recovery chiller, engine turbocharger sacked air temperature drop, and corresponding reduction in specific fuel consumption of the main low-speed diesel engine at varying actual climatic conditions on the voyage line were evaluated.
Journal Article
Capture of Pollutants from Exhaust Gases by Low-Temperature Heating Surfaces
2022
One of the most effective methods towards improving the environmental safety of combustion engines is the application of specially prepared water-fuel emulsions (WFE). The application of WFE makes it possible to reduce primary sulfur fuel consumption and reveals the possibility of capturing the pollutants from exhaust gases by applying condensing low-temperature heating surfaces (LTHS). In order to realize such a double effect, it is necessary to investigate the pollution processes on condensing LTHS of exhaust gas boilers (EGB), especially the process of low-temperature condensing a sulfuric acid vapor from exhaust gases to investigate the influence of condensing LTHS on the intensity of pollutants captured from the exhaust gases. The aim of this research is to assess the influence of the intensity of pollutants captured from exhaust gases by condensing LTHS in dependence of water content in WFE combustion. Investigations were carried out at a special experimental setup. The processing of the results of the experimental studies was carried out using the computer universal statistical graphic system Statgraphics. Results have shown that in the presence of a condensing heating surface, the degree of capture (purification) of pollutants from the exhaust gas flow is up to 0.5–0.6.
Journal Article
Enhancing the Fuel Efficiency of Cogeneration Plants by Fuel Oil Afterburning in Exhaust Gas before Boilers
by
Radchenko, Mykola
,
Radchenko, Roman
,
Kornienko, Victoria
in
Boilers
,
diesel engine
,
Efficiency
2023
Cogeneration or combined heat and power (CHP) has found wide application in various industries because it very effectively meets the growing demand for electricity, steam, hot water, and also has a number of operational, environmental, economic advantages over traditional electrical and thermal systems. Experimental and theoretical investigations of the afterburning of fuel oil in the combustion engine exhaust gas at the boiler inlet were carried out in order to enhance the efficiency of cogeneration power plants; this was achieved by increasing the boiler steam capacity, resulting in reduced production of waste heat and exhaust emissions. The afterburning of fuel oil in the exhaust gas of diesel engines is possible due to a high the excess air ratio (three to four). Based on the experimental data of the low-temperature corrosion of the gas boiler condensing heat exchange surfaces, the admissible values of corrosion rate and the lowest exhaust gas temperature which provide deep exhaust gas heat utilization and high efficiency of the exhaust gas boiler were obtained. The use of WFE and afterburning fuel oil provides an increase in efficiency and power of the CPPs based on diesel engines of up to 5% due to a decrease in the exhaust gas temperature at the outlet of the EGB from 150 °C to 90 °C and waste heat, accordingly. The application of efficient environmentally friendly exhaust gas boilers with low-temperature condensing surfaces can be considered a new and prosperous trend in diesel engine exhaust gas heat utilization through the afterburning of fuel oil and in CPPs as a whole.
Journal Article
Analysis of Efficiency of Thermopressor Application for Internal Combustion Engine
2022
Contact cooling using thermopressor technologies is a promising direction for the development of energy-efficient technologies. This technology is based on the implementation of the thermo-gas-dynamic compression effect in special contact heat exchangers that consists of increasing the pressure while decreasing the temperature during the evaporation of a finely dispersed liquid injected into a gas flow moving at a speed close to sound. Upon application of the thermopressor for charge air cooling of the engine, the following result was obtained: an increase in the air pressure after the turbocharger by 340 to 480 kPa. The thermopressor can be used as a boost stage after the turbocharger, resulting in the reduction of a basic turbocharger compression work and the increase of engine power output accordingly. Reducing the work allows for the same air flow rate on the internal combustion engine to reduce the compressor power by 10 to 12%. This increases the temperature of the exhaust gases at the inlet of the exhaust boiler by 10 to 15 °C and boiler steam capacity, resulting in an increase in the power output of the utilization turbine generator with a corresponding reduction in the fuel consumption of the diesel generator of the ship power plant by 2 to 3%.
Journal Article
Enhancing the Efficiency of Integrated Energy Systems by the Redistribution of Heat Based on Monitoring Data
2022
Integrated energy systems (IES) for combined power, heat and refrigeration supply achieved a wide application due to high flexibility in matching current loading. So as electricity is easily convertible into any other form of energy, gas engines are widely applied as driving engines characterized by high electrical and overall efficiency of about 45% and 90%, respectively. However, the highest thermal efficiency is achieved at full matching heat generated by the engine and heat transformed. This is often impossible in actual practice, especially if the heat is transformed into refrigeration by the most efficient and widespread absorption lithium-bromide chillers (ACh) and the heat not consumed by the ACh is removed from the atmosphere through an emergency radiator. The unused heat might be transformed by an ejector chiller (ECh) as the simplest and cheapest. So as the thermodynamic efficiency of any combustion engine is influenced essentially by the sucked air temperature, the excessive refrigeration produced by the ECh, is used for IES cooling to generate additional electricity and increase the electrical and overall efficiency of the engine. Such a redistribution of heat enables the enhancement of the efficiency of IES with an absorption-ejector chiller (AECh). The modified criteria for the comparative estimation of thermodynamic efficiency of innovative IESs with AEChs without overgenerated heat lost against a typical IES with an ACh and heat lost are proposed. In contrast to well-known electrical and heat efficiency, it considers the magnitude of heat loss and enables us to compare the heat efficiency of any version of transforming heat to refrigeration with an ideal basic version of IES based on a highly efficient ACh, transforming all the heat removed from the engine without heat loss. Some alternative scheme decisions for heat recovery systems have been developed based on monitoring data. They might be easily implemented into a typical IES with ACh.
Journal Article