Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
67 result(s) for "Ramberger, S."
Sort by:
Demonstration of cooling by the Muon Ionization Cooling Experiment
The use of accelerated beams of electrons, protons or ions has furthered the development of nearly every scientific discipline. However, high-energy muon beams of equivalent quality have not yet been delivered. Muon beams can be created through the decay of pions produced by the interaction of a proton beam with a target. Such ‘tertiary’ beams have much lower brightness than those created by accelerating electrons, protons or ions. High-brightness muon beams comparable to those produced by state-of-the-art electron, proton and ion accelerators could facilitate the study of lepton–antilepton collisions at extremely high energies and provide well characterized neutrino beams 1 – 6 . Such muon beams could be realized using ionization cooling, which has been proposed to increase muon-beam brightness 7 , 8 . Here we report the realization of ionization cooling, which was confirmed by the observation of an increased number of low-amplitude muons after passage of the muon beam through an absorber, as well as an increase in the corresponding phase-space density. The simulated performance of the ionization cooling system is consistent with the measured data, validating designs of the ionization cooling channel in which the cooling process is repeated to produce a substantial cooling effect 9 – 11 . The results presented here are an important step towards achieving the muon-beam quality required to search for phenomena at energy scales beyond the reach of the Large Hadron Collider at a facility of equivalent or reduced footprint 6 . Ionization cooling, a technique that delivers high-brightness muon beams for the study of phenomena at energy scales beyond those of the Large Hadron Collider, is demonstrated by the Muon Ionization Cooling Experiment.
Transverse emittance reduction in muon beams by ionization cooling
Accelerated muon beams have been considered for the next-generation studies of high-energy lepton–antilepton collisions and neutrino oscillations. However, high-brightness muon beams have not yet been produced. The main challenge for muon acceleration and storage stems from the large phase-space volume occupied by the beam, derived from the production mechanism of muons through the decay of pions. The phase-space volume of the muon beam can be decreased through ionization cooling. Here we show that ionization cooling leads to a reduction in the transverse emittance of muon beams that traverse lithium hydride or liquid hydrogen absorbers in the Muon Ionization Cooling Experiment. Our results represent a substantial advance towards the realization of muon-based facilities that could operate at the energy and intensity frontiers. Current muon beams have a phase-space volume that is too large for applications in muon colliders. Now, the reduction in the beam’s transverse emittance when passed through different absorbers in ionization cooling experiments is quantified.
Characterisation of the muon beams for the Muon Ionisation Cooling Experiment
A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/ c , have emittances of approximately 1.2–2.3  π  mm-rad horizontally and 0.6–1.0  π  mm-rad vertically, a horizontal dispersion of 90–190 mm and momentum spreads of about 25 MeV/ c . There is reasonable agreement between the measured parameters of the beams and the results of simulations. The beams are found to meet the requirements of MICE.
Characterisation of the muon beams for the Muon Ionisation Cooling Experiment
A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.2-2.3 π mm-rad horizontally and 0.6-1.0 π mm-rad vertically, a horizontal dispersion of 90-190 mm and momentum spreads of about 25 MeV/c. There is reasonable agreement between the measured parameters of the beams and the results of simulations. The beams are found to meet the requirements of MICE.
Lattice design and expected performance of the Muon Ionization Cooling Experiment demonstration of ionization cooling
Muon beams of low emittance provide the basis for the intense, well-characterized neutrino beams necessary to elucidate the physics of flavor at a neutrino factory and to provide lepton-antilepton collisions at energies of up to several TeV at a muon collider. The international Muon Ionization Cooling Experiment (MICE) aims to demonstrate ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. In an ionization-cooling channel, the muon beam passes through a material in which it loses energy. The energy lost is then replaced using rf cavities. The combined effect of energy loss and reacceleration is to reduce the transverse emittance of the beam (transverse cooling). A major revision of the scope of the project was carried out over the summer of 2014. The revised experiment can deliver a demonstration of ionization cooling. The design of the cooling demonstration experiment will be described together with its predicted cooling performance.
Lattice design and expected performance of the Muon Ionization Cooling Experiment demonstration of ionization cooling
Muon beams of low emittance provide the basis for the intense, well-characterized neutrino beams necessary to elucidate the physics of flavor at a neutrino factory and to provide lepton-antilepton collisions at energies of up to several TeV at a muon collider. The international Muon Ionization Cooling Experiment (MICE) aims to demonstrate ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. In an ionization-cooling channel, the muon beam passes through a material in which it loses energy. The energy lost is then replaced using rf cavities. The combined effect of energy loss and reacceleration is to reduce the transverse emittance of the beam (transverse cooling). A major revision of the scope of the project was carried out over the summer of 2014. The revised experiment can deliver a demonstration of ionization cooling. The design of the cooling demonstration experiment will be described together with its predicted cooling performance.
Changes in low‐acuity patient volume in an emergency department after launching a walk‐in clinic
AbstractObjectiveUnscheduled low‐acuity care options are on the rise and are often expected to reduce emergency department (ED) visits. We opened an ED‐staffed walk‐in clinic (WIC) as an alternative care location for low‐acuity patients at a time when ED visits exceeded facility capacity and the impending flu season was anticipated to increase visits further, and we assessed whether low‐acuity ED patient visits decreased after opening the WIC. MethodsIn this retrospective cohort study, we compared patient and clinical visit characteristics of the ED and WIC patients and conducted interrupted time‐series analyses to quantify the impact of the WIC on low‐acuity ED patient visit volume and the trend. ResultsThere were 27,211 low‐acuity ED visits (22.7% of total ED visits), and 7,058 patients seen in the WIC from February 26, 2018, to November 17, 2019. Low‐acuity patient visits in the ED reduced significantly immediately after the WIC opened ( P = 0.01). In the subsequent months, however, patient volume trended back to pre‐WIC volumes such that there was no significant impact at 6, 9, or 12 months ( P = 0.07). Had WIC patients been seen in the main ED, low‐acuity volume would have been 27% of the total volume rather than the 22.7% that was observed. ConclusionThe WIC did not result in a sustained reduction in low‐acuity patients in the main ED. However, it enabled emergency staff to see low‐acuity patients in a lower resource setting during times when ED capacity was limited.