Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
32 result(s) for "Ratnayaka, Kanishka"
Sort by:
Interventional cardiovascular magnetic resonance: state-of-the-art
Transcatheter cardiovascular interventions increasingly rely on advanced imaging. X-ray fluoroscopy provides excellent visualization of catheters and devices, but poor visualization of anatomy. In contrast, magnetic resonance imaging (MRI) provides excellent visualization of anatomy and can generate real-time imaging with frame rates similar to X-ray fluoroscopy. Realization of MRI as a primary imaging modality for cardiovascular interventions has been slow, largely because existing guidewires, catheters and other devices create imaging artifacts and can heat dangerously. Nonetheless, numerous clinical centers have started interventional cardiovascular magnetic resonance (iCMR) programs for invasive hemodynamic studies or electrophysiology procedures to leverage the clear advantages of MRI tissue characterization, to quantify cardiac chamber function and flow, and to avoid ionizing radiation exposure. Clinical implementation of more complex cardiovascular interventions has been challenging because catheters and other tools require re-engineering for safety and conspicuity in the iCMR environment. However, recent innovations in scanner and interventional device technology, in particular availability of high performance low-field MRI scanners could be the inflection point, enabling a new generation of iCMR procedures. In this review we review these technical considerations, summarize contemporary clinical iCMR experience, and consider potential future applications.
Specialized Delivery Room Planning for Fetuses With Critical Congenital Heart Disease
Improvements in fetal echocardiography have increased recognition of fetuses with congenital heart disease (CHD) that require specialized delivery room (DR) care. In this study, care protocols for these low-volume and high-risk deliveries were created. Elements included (1) diagnosis-specific DR care plans and algorithms, (2) a multidisciplinary team with expertise, (3) simulation, (4) checklists, and (5) debriefing. The purpose of this study was to assess the accuracy of fetal echocardiography to predict the need for specialized DR care and determine the effectiveness of the care protocols for the treatment of patients with critical CHD. Fetal and postnatal medical records and echocardiograms of fetuses with CHD assigned to an advanced level of care were reviewed. Safety and outcome variables were analyzed to determine care plan and algorithm efficacy. Thirty-four fetuses were identified: 12 delivered at Children's National Medical Center and 22 at the adult hospital. Diagnoses included hypoplastic left heart syndrome, aortic stenosis, d-transposition of the great arteries, tetralogy of Fallot with absent pulmonary valve, complex pulmonary atresia, arrhythmias, ectopia cordis, and conjoined twins. Delivery at Children's National Medical Center was associated with a shorter time to specialty care or intervention. Measures of physiologic stability and survival were similar. Need for specialized care was predicted in 84% of deliveries. For hypoplastic left heart syndrome, intervention was predicted in 10 of 11 deliveries and for d-transposition of the great arteries in 10 of 12 deliveries. Care algorithms addressed most DR events. Of the unanticipated events, none were unrecoverable. DR survival was 100%, and survival to discharge was 83%. In conclusion, fetal echocardiography predicted the need for specialized DR care in fetuses with critical CHD. Algorithm-driven protocols enable planning such that maternal and infant risk is minimized and outcomes are good.
CMR fluoroscopy right heart catheterization for cardiac output and pulmonary vascular resistance: results in 102 patients
Quantification of cardiac output and pulmonary vascular resistance (PVR) are critical components of invasive hemodynamic assessment, and can be measured concurrently with pressures using phase contrast CMR flow during real-time CMR guided cardiac catheterization. One hundred two consecutive patients underwent CMR fluoroscopy guided right heart catheterization (RHC) with simultaneous measurement of pressure, cardiac output and pulmonary vascular resistance using CMR flow and the Fick principle for comparison. Procedural success, catheterization time and adverse events were prospectively collected. RHC was successfully completed in 97/102 (95.1%) patients without complication. Catheterization time was 20 ± 11 min. In patients with and without pulmonary hypertension, baseline mean pulmonary artery pressure was 39 ± 12 mmHg vs. 18 ± 4 mmHg (p < 0.001), right ventricular (RV) end diastolic volume was 104 ± 64 vs. 74 ± 24 (p = 0.02), and RV end-systolic volume was 49 ± 30 vs. 31 ± 13 (p = 0.004) respectively. 103 paired cardiac output and 99 paired PVR calculations across multiple conditions were analyzed. At baseline, the bias between cardiac output by CMR and Fick was 5.9% with limits of agreement −38.3% and 50.2% with r = 0.81 (p < 0.001). The bias between PVR by CMR and Fick was −0.02 WU.m2 with limits of agreement −2.6 and 2.5 WU.m2 with r = 0.98 (p < 0.001). Correlation coefficients were lower and limits of agreement wider during physiological provocation with inhaled 100% oxygen and 40 ppm nitric oxide. CMR fluoroscopy guided cardiac catheterization is safe, with acceptable procedure times and high procedural success rate. Cardiac output and PVR measurements using CMR flow correlated well with the Fick at baseline and are likely more accurate during physiological provocation with supplemental high-concentration inhaled oxygen. Clinicaltrials.gov NCT01287026, registered January 25, 2011.
Radiation-free CMR diagnostic heart catheterization in children
Children with heart disease may require repeated X-Ray cardiac catheterization procedures, are more radiosensitive, and more likely to survive to experience oncologic risks of medical radiation. Cardiovascular magnetic resonance (CMR) is radiation-free and offers information about structure, function, and perfusion but not hemodynamics. We intend to perform complete radiation-free diagnostic right heart catheterization entirely using CMR fluoroscopy guidance in an unselected cohort of pediatric patients; we report the feasibility and safety. We performed 50 CMR fluoroscopy guided comprehensive transfemoral right heart catheterizations in 39 pediatric (12.7 ± 4.7 years) subjects referred for clinically indicated cardiac catheterization. CMR guided catheterizations were assessed by completion (success/failure), procedure time, and safety events (catheterization, anesthesia). Pre and post CMR body temperature was recorded. Concurrent invasive hemodynamic and diagnostic CMR data were collected. During a twenty-two month period (3/2015 – 12/2016), enrolled subjects had the following clinical indications: post-heart transplant 33%, shunt 28%, pulmonary hypertension 18%, cardiomyopathy 15%, valvular heart disease 3%, and other 3%. Radiation-free CMR guided right heart catheterization attempts were all successful using passive catheters. In two subjects with septal defects, right and left heart catheterization were performed. There were no complications. One subject had six such procedures. Most subjects (51%) had undergone multiple (5.5 ± 5) previous X-Ray cardiac catheterizations. Retained thoracic surgical or transcatheter implants (36%) did not preclude successful CMR fluoroscopy heart catheterization. During the procedure, two subjects were receiving vasopressor infusions at baseline because of poor cardiac function, and in ten procedures, multiple hemodynamic conditions were tested. Comprehensive CMR fluoroscopy guided right heart catheterization was feasible and safe in this small cohort of pediatric subjects. This includes subjects with previous metallic implants, those requiring continuous vasopressor medication infusions, and those requiring pharmacologic provocation. Children requiring multiple, serial X-Ray cardiac catheterizations may benefit most from radiation sparing. This is a step toward wholly CMR guided diagnostic (right and left heart) cardiac catheterization and future CMR guided cardiac intervention. ClinicalTrials.gov NCT02739087 registered February 17, 2016
Starting and Operating a Public Cardiac Catheterization Laboratory in a Low Resource Setting: The Eight-Year Story of the Uganda Heart Institute Catheter Laboratory
Low- and-middle-income-countries (LMICs) currently bear 80% of the world's cardiovascular disease (CVD) mortality burden. The same countries are underequipped to handle the disease burden due to critical shortage of resources. Functional cardiac catheterization laboratories (cath labs) are central in the diagnosis and management of CVDs. Yet, most LMICs, including Uganda, fall remarkably below the minimum recommended standards of cath lab:population ratio due to a host of factors including the start-up and recurring costs. To review the performance, challenges and solutions employed, lessons learned, and projections for the future for a single cath lab that has been serving the Ugandan population of 40 million people in the past eight years. A retrospective review of the Uganda Heart Institute cath lab clinical database from 15 February 2012 to 31 December 2019 was performed. In the initial two years, this cath lab was dependent on skills transfer camps by visiting expert teams, but currently, Ugandan resident specialists independently operate this lab. 3,542 adult and pediatric procedures were conducted in 8 years, including coronary angiograms and percutaneous coronary interventions, device implantations, valvuloplasties, and cardiac defect closures, among others. There was a consistent expansion of the spectrum of procedures conducted in this cath lab each year. The initial lack of technical expertise and sourcing for equipment, as well as the continual need for sundries present(ed) major roadblocks. Government support and leveraging existing multi-level collaborations has provided a platform for several solutions. Sustainability of cath lab services remains a significant challenge especially in relation to the high cost of sundries and other consumables amidst a limited budget. A practical example of how centers in LMIC can set up and sustain a public cardiac catheterization laboratory is presented. Government support, research, and training collaborations, if present, become invaluable leverage opportunities.
MRI-Guided Cardiac Catheterization in Congenital Heart Disease: How to Get Started
Purpose of ReviewCardiac magnetic resonance imaging provides radiation-free, 3-dimensional soft tissue visualization with adjunct hemodynamic data, making it a promising candidate for image-guided transcatheter interventions. This review focuses on the benefits and background of real-time magnetic resonance imaging (MRI)-guided cardiac catheterization, guidance on starting a clinical program, and recent research developments.Recent FindingsInterventional cardiac magnetic resonance (iCMR) has an established track record with the first entirely MRI-guided cardiac catheterization for congenital heart disease reported nearly 20 years ago. Since then, many centers have embarked upon clinical iCMR programs primarily performing diagnostic MRI-guided cardiac catheterization. There have also been limited reports of successful real-time MRI-guided transcatheter interventions. Growing experience in performing cardiac catheterization in the magnetic resonance environment has facilitated practical workflows appropriate for efficiency-focused cardiac catheterization laboratories. Most exciting developments in imaging technology, MRI-compatible equipment and MRI-guided novel transcatheter interventions have been limited to preclinical research. Many of these research developments are ready for clinical translation.SummaryWith increasing iCMR clinical experience and translation of preclinical research innovations, the time to make the leap to radiation-free procedures is now.
MRI Catheterization: Ready for Broad Adoption
In recent years, interventional cardiac magnetic resonance imaging (iCMR) has evolved from attractive theory to clinical routine at several centers. Real-time cardiac magnetic resonance imaging (CMR fluoroscopy) adds value by combining soft-tissue visualization, concurrent hemodynamic measurement, and freedom from radiation. Clinical iCMR applications are expanding because of advances in catheter devices and imaging. In the near future, iCMR promises novel procedures otherwise unsafe under standalone X-Ray guidance.
Institutional Trend in Device Selection for Transcatheter PDA Closure in Premature Infants
We report our experience with transcatheter patent ductus arteriosus (PDA) closure in premature infants and compare patients grouped by the device used for closure: the Microvascular Plug, “MVP” (Medtronic, Minneapolis, MN); Micro Plug Set, “Micro Plug” (KA Medical, Minneapolis, MN); and Amplatzer Piccolo Occluder, “Piccolo” (Abbot, Santa Clara, CA). We also report trends in device selection over time. Studies examining outcomes according to device selection for PDA closure in premature infants are lacking. We performed a retrospective review of all percutaneous PDA closures in premature infants at a single center (June 2018–May 2021). Patients were grouped by initial device selected for PDA closure (intention to treat). Institutional Review Board approval was obtained. 58 premature infants [MVP ( n  = 25), Micro Plug ( n  = 25), and Piccolo ( n  = 8)] underwent successful transcatheter PDA closure (mean gestational age 27 weeks 2 days; mean weight at procedure 1.4 kg; mean age at procedure 28 days). Pre-procedural demographics, procedural data, and follow-up data were similar between groups. There were no significant procedural adverse events. Three devices (2 MVP, 0 Micro Plug, 1 Piccolo p  = 0.27) embolized after the procedure. One other device was removed for concern for aortic obstruction. Device selection evolved with a clear trend toward the Micro Plug device over time. Demographic, procedural, and follow-up data were similar between the MVP, Micro Plug, and Piccolo groups. The Micro Plug did not require exchange for suboptimal fitting or embolize and became our preferred device in most cases.
A review: Percutaneous pulmonary artery stenosis therapy: state-of-the-art and look to the future
Stenosis, or narrowing, of the branches of the pulmonary artery is a type of CHD that, if left untreated, may lead to significant complications. Ideally, interventions to treat stenosis occur before significant complications or long-term sequelae take place, often within the first 2 years of life. Treatment depends on specifics of the condition, the presence of other malformations, and age of the child. Research and recent innovation to address these shortcomings have provided physicians with safer and more effective methods of treatment. This has further continued to push the ceiling of pulmonary arterial stenosis treatment available for patients. Despite continuous advancement in angioplasty – such as conventional and cutting balloon – and stenting, each treatment method is not without its unique limitations. New technological developments such as bioresorbable stents can accommodate patient growth and pulmonary artery stenosis treatment. As more than a decade has passed since the review by Bergersen and Lock, this article aims to provide a contemporary summary and investigation into the effectiveness of various therapeutic tools currently available, such as bare metal stents and potential innovations including bioresorbable stents.
Whole shaft visibility and mechanical performance for active MR catheters using copper-nitinol braided polymer tubes
Catheter visualization and tracking remains a challenge in interventional MR. Active guidewires can be made conspicuous in “profile” along their whole shaft exploiting metallic core wire and hypotube components that are intrinsic to their mechanical performance. Polymer-based catheters, on the other hand, offer no conductive medium to carry radio frequency waves. We developed a new “active” catheter design for interventional MR with mechanical performance resembling braided X-ray devices. Our 75 cm long hybrid catheter shaft incorporates a wire lattice in a polymer matrix, and contains three distal loop coils in a flexible and torquable 7Fr device. We explored the impact of braid material designs on radiofrequency and mechanical performance. The incorporation of copper wire into in a superelastic nitinol braided loopless antenna allowed good visualization of the whole shaft (70 cm) in vitro and in vivo in swine during real-time MR with 1.5 T scanner. Additional distal tip coils enhanced tip visibility. Increasing the copper:nitinol ratio in braiding configurations improved flexibility at the expense of torquability. We found a 16-wire braid of 1:1 copper:nitinol to have the optimum balance of mechanical (trackability, flexibility, torquability) and antenna (signal attenuation) properties. With this configuration, the temperature increase remained less than 2°C during real-time MR within 10 cm horizontal from the isocenter. The design was conspicuous in vitro and in vivo. We have engineered a new loopless antenna configuration that imparts interventional MR catheters with satisfactory mechanical and imaging characteristics. This compact loopless antenna design can be generalized to visualize the whole shaft of any general-purpose polymer catheter to perform safe interventional procedures.